• 제목/요약/키워드: Concrete Fire Resistance

검색결과 428건 처리시간 0.024초

Fire resistance of high strength concrete filled steel tubular columns under combined temperature and loading

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • 제27권2호
    • /
    • pp.243-253
    • /
    • 2018
  • In recent years, concrete-filled box or tubular columns have been commonly used in high-rise buildings. However, a number of fire test results show that there are significant differences between high strength concrete (HSC) and normal strength concrete (NSC) after being subjected to high temperatures. Therefore, this paper presents an investigation on the fire resistance of HSC filled steel tubular columns (CFTCs) under combined temperature and loading. Two groups of full-size specimens were fabricated to consider the effect of type of concrete infilling (plain and reinforced) and the load level on the fire resistance of CFTCs. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The results demonstrate that the higher the axial load level, the worse the fire resistance. Moreover, in the bar-reinforced concrete-filled steel tubular columns, the presence of rebars not only decreased the spread of cracks and the sudden loss of strength, but also contributed to the load-carrying capacity of the concrete core.

초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구 (A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete)

  • 백영운;육태원;박동수;김한솔;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

재하하중에 따른 고강도 CFT의 내화성능 평가 (Evaluation for fire resistance performance of high strength CFT with loading)

  • 홍석범;유조형;김우재;이지환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.184-185
    • /
    • 2013
  • Concrete filled steel Tube(CFT) columns have great strength but also fire resistance performance due to the heat storage effect of concrete. In this research, we focus on the fire performance of CFT using 100 MPa concrete without fire protection. We use steel fiber and nylon fiber for fire resistance. We perform the fire test of CFT specimen with loading 200, 300 and 400 ton. To investigate the effect of loading to fire resistance, we compare the fire resistance time according to the loading.

  • PDF

와이어로프를 적용한 고강도 철근콘크리트 기둥의 내화공법 및 하중비에 따른 내화성능에 관한 연구 (A Study on the Fire Resistance Performance Concerning Types of Fire Protection Method and Load Ratio of High Strength Concrete Column Using The Wire Rope)

  • 조범연;여인환;김흥열;김형준;권인규
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.64-71
    • /
    • 2012
  • 60 MPa급, 100 MPa급 고강도 철근콘크리트 기둥에 대하여 횡구속력 보강공법(와이어로프)과 내화보강공법(Fiber-Cocktail) 적용 유무 및 하중비에 따른 내화성능을 평가하기 위하여 표준화재 재하조건에 내화실험을 실시하였다. 실험결과 60 MPa급 고강도 콘크리트 기둥의 경우 와이어로프를 적용함으로써 화재시 축방향의 연성이 향상되며, 내화성능은 23 % 이상 향상되는 것으로 나타났다. 또한 와이어로프를 적용할 경우 하중은 설계하중의 70 % 수준이 적정하다고 판단된다. 100MPa급 고강도 콘크리트 기둥에 와이어로프와 Fiber-Cocktail을 적용할 경우 띠철근만을 적용한 경우보다 내화성능이 4배 이상 향상되는 것으로 나타났으며, 100MPa급 고강도 콘크리트 기둥에 내화성능을 확보하기 위해서는 하중은 설계하중의 70 % 미만으로 설정하는 것이 적정하다고 판단된다.

대한건축학회의 구조내화설계 가이드라인에 관한 연구 (A Study on the Fire Resistance Design Guidelines for High-Strength Concrete Structures of AIK)

  • 권영진;신이철;이재영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.21-25
    • /
    • 2008
  • It is the aim of this study to investigate the fire resistance design Guidelines for high-strength concrete structure for example compressive strength more than 40Mpa. It is well know that explosive spalling due to fire attack of high strength concrete is related to concrete failure. so, the purpose of this study introduce the fire A Studty on the Fire Resistance Design Guidelines for High-Strength Concrete Structures of AIK for the response of explosive spalling of high strength concrete.

  • PDF

100MPa급 내화피복 고강도 콘크리트의 내화성능 인증 (Fire Performance of 100MPa High Strength Concrete with Fire Protection Cover)

  • 송영찬;김용로;김욱종;이도범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 2부
    • /
    • pp.21-22
    • /
    • 2010
  • In this research, the purpose is to share fire resistance method to secure 3 hours fire resistance performance which is regulation noticed by Ministry of Land, Transport and Maritime Affairs for 100MPa high strength concrete which is predicted to apply to high rise building and to propose the guideline for confirmation of fire resistance performance of high strength concrete member to which fire resistance method is applied and field application in advance.

  • PDF

화재진압시간에 따른 콘크리트의 염해저항성 평가 (Evaluation of Salt Damage Resistance of Concrete according to Fire Control Time)

  • 이준해;박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2020
  • In the event of a fire, fire engines usually arrive within 15 minutes and become a fire suppressor. In this paper, an analytical model was established to evaluate the salt damage resistance of concrete according to fire suppression time, and the concentration of salt inside the concrete after fire was measured and the time to reach the critical concentration was assessed by how short.

  • PDF

화재시 온도증가로 인한 RC 슬래브의 강도 특성 (Strength Properties of RC Slabs under Elevated Temperatures from Fire)

  • 임초롱;정철헌;김유석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.48-60
    • /
    • 2010
  • The fire resistance performance of 2 RC slabs after exposure to the ISO-834 fire standard without loading has been experimentally investigated. A Comparison is made of the fire resistance performance between RC slabs without PP(polypropylene) fibers and RC slabs with PP fibers. From the fire test results, the presence of PP fibers in RC slabs can reduce spalling and enhance their fire resistance. Until now, the determination of fire resistance of reinforced concrete(RC) slabs has essentially been based on tabulated data. According to ACI 216 code and EUROCODE 2, the design of concrete structures is essentially based on tabulated data for appropriate concrete cover and various fire durations. From the comparison between fire test results and codes, current fire design provisions of codes such as the ACI 216 and the EUROCODE 2 are unconservative for estimating mechanical properties of RC slabs at elevated temperatures.

Bond behavior of PP fiber-reinforced cinder concrete after fire exposure

  • Cai, Bin;Wu, Ansheng;Fu, Feng
    • Computers and Concrete
    • /
    • 제26권2호
    • /
    • pp.115-125
    • /
    • 2020
  • To reduce the damage of concrete in fire, a new type of lightweight cinder aggregate concrete was developed due to the excellent fire resistance of cinder. To further enhance its fire resistance, Polypropylene (PP) Fibers which can enhance the fire resistance of concrete were also used in this type of concrete. However, the bond behavior of this new type of concrete after fire exposure is still unknown. To investigate its bond behavior, 185 specimens were heated up to 22, 200, 400, 600 or 800℃ for 2 h duration respectively, which is followed by subsequent compressive and tensile tests at room temperature. The concrete-rebar bond strength of C30 PP fiber-reinforced cinder concrete was subsequently investigated through pull-out tests after fire exposure. The microstructures of the PP fiber-reinforced cinder concrete and the status of the PP fibre at different temperature were inspected using an advanced scanning electron microscopy, aiming to understand the mechanism of the bonding deterioration under high temperature. The effects of rebar diameter and bond length on the bond strength of PP fiber-reinforced cinder concrete were investigated based on the test results. The bond-slip relation of PP fiber-reinforced cinder concrete after exposure at different temperature was derived based on the test results.

현장 적용을 위한 섬유혼입 고강도콘크리트의 내화특성에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Properties of High Strength Concrete using Fiber for Field Application)

  • 김용로;송영찬;정양희;김욱종;이도범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.187-191
    • /
    • 2008
  • It is necessary to develop a technology for effectively controling explosive spalling of high strength concrete caused increasing construction of high rise building and putting up the fireproof standard of high strength concrete by MLTM (Ministry of Land, Transport and Maritime Affairs). Accordingly, it was investigated basic properties such as slump, air content and compressive strength, and fire resistance properties of high strength concrete using polypropylene fiber for field application as a countermeasure for explosive spalling of concrete on fire in this study, As a test result, it was confirmed that PP fiber is available as fire resistance method of high strength concrete.

  • PDF