• Title/Summary/Keyword: Concrete Filled Tubular

Search Result 277, Processing Time 0.021 seconds

Evaluation of Structural Performance in CFT Truss Girder with the Arch-Shaped Lower Chord (아치형상의 하현재를 갖는 CFT 트러스 거더의 구조성능 평가)

  • Chung, Chul-Hun;Song, Na-Young;Ma, Hyang-Wook;Oh, Hyun-Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.315-327
    • /
    • 2009
  • In this study, the static test of CFT truss girders for different f/L ratios was conducted to determine how the ultimate strength of the CFT truss girder was affected by different f/L ratios. A total of two CFT truss girders were constructed and tested under bending condition. The length of all specimens is 20,000 mm. The CFT truss girder is a tubular truss composed of chord members made of concrete-filled circular tubes. The main parameter analyzed in the experimental study was the f/L ratio. This factor was experimentally investigated to assess their influence on ultimate strength and stiffness. The test results show that CFT truss girder has good elastic-plastic property and ductility. The presence of the f/L ratios in CFT truss girders alters its ultimate strength because of the global stiffness of the CFT truss girders. The ultimate strength of CFT truss girders increases as the f/L ratio increases. If the f/L ratio of the CFT truss girders increases twofold, the ultimate strengths increase by 80%. The CFT truss girders showed that they retained large deformation capacity, even after reaching the ultimate strength. Results of this investigation demonstrated the potential for efficiently using a CFT truss as a bridge girder.

A Study on the Equations for Load Carrying Capacities of Concrete Filled tubular Square Column-to-Beam Connections with Combined Cross Diaphragm and Sleeves (복합십자형 CFT 기둥-보 접합부의 내력식에 관한 연구)

  • Choi, Sung Mo;Jung, Do Sub;Kim, Dae Joong;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.419-429
    • /
    • 2005
  • The objective of this study is to clarify the structural features of members consisting of a connection, as part of the previous study on the CFT column-to-beam tensile connection with a combined cross diaphragm. This connection has the following merits: it evenly distributes the stress on the beam flange and the diaphragm and reduces the stress concentration by improving the stress transfer route and restraining the abrupt deformation of the diaphragm. Finite element analysis was performed to find out the stress transfer through the sleeve, which is an important member of the connection with a combined cross diaphragm. The length and thickness of the sleeve were used as variables for the analysis. The analysis results showed that the length and thickness of the sleeve did not influence the capacity of the connection and played the role of a medium for the transfer of the stress from the diaphragm to the filled concrete. It was proposed that the appropriate length of the sleeve have the same value as the diameter of the sleeve and that the appropriate ratio of the sleeve diameter to the sleeve thickness be 20. Two equations for the evaluation of the load carrying the capacity of the connection were also proposed through the modification of the evaluation equation suggested in the previous study.

Behavior of stiffened and unstiffened CFT under concentric loading, An experimental study

  • Deifalla, Ahmed F.;Fattouh, Fattouh M.;Fawzy, Mona M.;Hussein, Ibrahim S.
    • Steel and Composite Structures
    • /
    • v.33 no.6
    • /
    • pp.793-803
    • /
    • 2019
  • Concrete-filled steel tubular (CFST) beam-columns are widely used owing to their good performance. They have high strength, ductility, large energy absorption capacity and low costs. Externally stiffened CFST beam-columns are not used widely due to insufficient design equations that consider all parameters affecting their behavior. Therefore, effect of various parameters (global, local slenderness ratio and adding hoop stiffeners) on the behavior of CFST columns is studied. An experimental study that includes twenty seven specimens is conducted to determine the effect of those parameters. Load capacities, vertical deflections, vertical strains and horizontal strains are all recorded for every specimen. Ratio between outer diameter (D) of pipes and thickness (t) is chosen to avoid local buckling according to different limits set by codes for the maximum D/t ratio. The study includes two loading methods on composite sections: steel only and steel with concrete. The case of loading on steel only, occurs in the connection zone, while the other load case occurs in steel beam connecting externally with the steel column wall. Two failure mechanisms of CFST columns are observed: yielding and global buckling. At early loading stages, steel wall in composite specimens dilated more than concrete so no full bond was achieved which weakened strength and stiffness of specimens. Adding stiffeners to the specimens increases the ultimate load by up to 25% due to redistribution of stresses between stiffener and steel column wall. Finally, design equations previously prepared are verified and found to be only applicable for medium and long columns.

An experimental and numerical study on temperature gradient and thermal stress of CFST truss girders under solar radiation

  • Peng, Guihan;Nakamura, Shozo;Zhu, Xinqun;Wu, Qingxiong;Wang, Hailiang
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.605-616
    • /
    • 2017
  • Concrete filled steel tubular (CFST) composite girder is a new type of structures for bridge constructions. The existing design codes cannot be used to predict the thermal stress in the CFST truss girder structures under solar radiation. This study is to develop the temperature gradient curves for predicting thermal stress of the structure based on field and laboratory monitoring data. An in-field testing had been carried out on Ganhaizi Bridge for over two months. Thermal couples were installed at the cross section of the CFST truss girder and the continuous data was collected every 30 minutes. A typical temperature gradient mode was then extracted by comparing temperature distributions at different times. To further verify the temperature gradient mode and investigate the evolution of temperature fields, an outdoor experiment was conducted on a 1:8 scale bridge model, which was installed with both thermal couples and strain gauges. The main factors including solar radiation and ambient temperature on the different positions were studied. Laboratory results were consistent with that from the in-field data and temperature gradient curves were obtained from the in-field and laboratory data. The relationship between the strain difference at top and bottom surfaces of the concrete deck and its corresponding temperature change was also obtained and a method based on curve fitting was proposed to predict the thermal strain under elevated temperature. The thermal stress model for CFST composite girder was derived. By the proposed model, the thermal stress was obtained from the temperature gradient curves. The results using the proposed model were agreed well with that by finite element modelling.

Spatial mechanical behaviors of long-span V-shape rigid frame composite arch bridges

  • Gou, Hongye;Pu, Qianhui;Wang, Junming;Chen, Zeyu;Qin, Shiqiang
    • Structural Engineering and Mechanics
    • /
    • v.47 no.1
    • /
    • pp.59-73
    • /
    • 2013
  • The Xiaolan channel super large bridge is unique in style and with greatest span in the world with a total length of 7686.57 m. The main bridge with spans arranged as 100m+220m+100m is a combined structure composed of prestressed concrete V-shape rigid frame and concrete-filled steel tubular flexible arch. First of all, the author compiles APDL command flow program by using the unit birth-death technique and establishes simulation calculation model in the whole construction process. The creep characteristics of concrete are also taken into account. The force ratio of the suspender, arch and beam is discussed. The authors conduct studies on the three-plate webs's rule of shear stress distribution, the box girder's longitudinal bending normal stress on every construction stage, meanwhile the distribution law of longitudinal bending normal stress and transverse bending normal stress of completed bridge's box girder. Results show that, as a new combined bridge, it is featured by: Girder and arch resist forces together; Moment effects of the structure are mainly presented as compressed arch and tensioned girder; The bridge type brings the girder and arch on resisting forces into full play; Great in vertical stiffness and slender in appearance.

Estimation of the Local Load-Carrying Capacities of CFCT Column to H-Beam Connections by Yield Line Model -With regard to the Tensile side of Beam flange- (인장측 보플랜지의 항복선 모델을 이용한 CFCT기둥-H형강보 접합부의 국부내력평가)

  • Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.525-536
    • /
    • 1998
  • This paper is concerned with a theoretical study on the local load-carrying capacities of Concrete-Filled Circular Tubular(CFCT) column to H-beam connections by yield line theory. In this paper, the three cases which are assumed the yield line are involved. The first model is a simplified yield line model. The second model is modified by x and kx factors. The last one is a Morita's model. The local load-carrying capacities of CFCT column to H-beam connections has been studied both experimentally and theoretically using the yield line theory. The purpose of this paper is to suggest the basic data for developing the non-diaphragm connection.

  • PDF

The Structural Behavior of CFCT Column to H-Beam Connections With Longitudinal Rib of Column at Joint (종리브로 보강한 콘크리트충전원형강관기둥-H형강보 접합부의 구조적 거동에 관한 연구)

  • Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.291-301
    • /
    • 1998
  • This paper is a study on the structural behavior of CFCT(Concrete-Filled Circular Tubular) column to H-beam connections with longitudinal rib. The important parameters are being longitudinal rib or not. variable column thickness(5.8mm. 9.2mm. 12.0mm. 15.0mm) around the joint between CFCT and H-beam and the width of flange to diameter. Test results are summarized for the strength, initial stiffness, failure mode and energy absorption capacities of each specimen. These are compared with the theoretical results(Yield line theory, numerical analysis). Therefore, the purpose of this paper is to investigate the stiffness and the strength of connections to evaluate the structural behavior of the CFCT column to H-beam connections with longitudinal rib.

  • PDF

Dynamic Amplification Factor of Concrete-Filled Tubular Arch (CFTA) Girder due to the Effects of Moving Vehicles and PT Tendons (이동차량 및 PT 텐던 영향에 따른 CFTA 거더의 동적증폭계수 비교)

  • Roh, Hwa-Sung;Hong, Sang-Hyun;Lee, Sang-Yun;Park, Kyung-Hoon;Lee, Jong-Seh
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.743-746
    • /
    • 2011
  • 본 연구에서는 유한요소해석을 이용하여 차량속도 및 긴장재의 설계에 따른 CFTA 거더의 동적거동 및 동적증폭계수를 분석하였다. 긴장재의 해석변수로서는 긴장재의 양과 긴장력을 고려하였으며 차량하중은 도로교설계기준의 DB-24 하중을 선택하였다. 차량하중은 3축-2트랙에 작용하는 등가절점하중으로 변환하여 속도에 따라 시간함수로 모델링하였다. 긴장재의 양은 외측 �� 내측 덕트의 유무에 따라 변화시켰으며 긴장력은 설계긴장력의 0%에서 100%까지 25%씩 증가시켰다. 차량속도는 40km/hr에서 100km/hr까지 20km/hr씩 증가시켰으며, 해석결과 긴장재의 긴장력 변화는 거더의 동적거동에 영향을 주지 않았으며 초기처짐에만 영향을 주었다. 긴장재의 양에 따라서는 거더의 동적거동이 다르게 나타났으며 긴장재의 양이 적을 수록 동적처짐은 증가하였다. 이를 바탕으로 거더의 동적증폭계수(DAF)를 산출하였으며, 이 결과 긴장재가 없는 경우에도 도로교표준시방서에서 정한 기준 값보다 매우 작은 거동을 보였다.

  • PDF

Seismic performance of the thin-walled square CFST columns with lining steel tubes

  • Wang, Xuanding;Liu, Jiepeng;Wang, Xian-Tie;Cheng, Guozhong;Ding, Yan
    • Steel and Composite Structures
    • /
    • v.44 no.3
    • /
    • pp.423-436
    • /
    • 2022
  • This paper proposes an innovative thin-walled square concrete filled steel tubular (CFST) column with an octagonal/circular lining steel tube, in which the outer steel tube and the inner liner are fabricated independently of each other and connected by slot-weld or self-tapping screw connections. Twelve thin-walled square CFST columns were tested under quasi-static loading, considering the parameters of liner type, connection type between the square tube and liner, yield strength of steel tube, and the axial load ratio. The seismic performance of the thin-walled square CFST columns is effectively improved by the octagonal and circular liners, and all the liner-stiffened specimens showed an excellent ductile behavior with the ultimate draft ratios being much larger than 1/50 and the ductility coefficients being generally higher than 4.0. The energy dissipation abilities of the specimens with circular liners and self-tapping screw connections were superior to those with octagonal liner and slot-weld connections. Based on the test results, both the finite element (FE) and simplified theoretical models were established, considering the post-buckling strength of the thin-walled square steel tube and the confinement effect of the liners, and the proposed models well predicted the hysteretic behavior of the liner-stiffened specimens.

A component method model for blind-bolts with headed anchors in tension

  • Pitrakkos, Theodoros;Tizani, Walid
    • Steel and Composite Structures
    • /
    • v.18 no.5
    • /
    • pp.1305-1330
    • /
    • 2015
  • The successful application of the component-based approach - widely used to model structural joints - requires knowledge of the mechanical properties of the constitutive joint components, including an appropriate assembly procedure to derive the joint properties. This paper presents a component-method model for a structural joint component that is located in the tension zone of blind-bolted connections to concrete-filled tubular steel profiles. The model relates to the response of blind-bolts with headed anchors under monotonic loading, and the blind-bolt is termed the "Extended Hollo-bolt". Experimental data is used to develop the model, with the data being collected in a manner such that constitutive models were characterised for the principal elements which contribute to the global deformability of the connector. The model, based on a system of spring elements, incorporates pre-load and deformation from various parts of the blind-bolt: (i) the internal bolt elongation; (ii) the connector's expanding sleeves element; and (iii) the connector's mechanical anchorage element. The characteristics of these elements are determined on the basis of piecewise functions, accounting for basic geometrical and mechanical properties such as the strength of the concrete applied to the tube, the connection clamping length, and the size and class of the blind-bolt's internal bolt. An assembly process is then detailed to establish the model for the elastic and inelastic behaviour of the component. Comparisons of model predictions with experimental data show that the proposed model can predict with sufficient accuracy the response of the component. The model furthers the development of a full and detailed design method for an original connection technology.