• Title/Summary/Keyword: Concrete Crack Depth

Search Result 204, Processing Time 0.027 seconds

Tests of concrete slabs reinforced with CFRP prestressed prisms

  • Liang, Jiongfeng;Yu, Deng;Yang, Zeping;Chai, Xinjun
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.355-366
    • /
    • 2016
  • This paper reports the testing of concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) on the flexural behavior. Four concrete slabs were tested, a reference slab reinforced with steel bars, and three slabs reinforced with CFRP prestressed concrete prisms (PCP). All slabs were made with dimensions of 600mm in width, 2200mm in length and 150 in depth. All concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) exhibited CFRP bar rupture failure mode. It was shown that the application of the CFRP prestressed prisms can limit service load deflections and crack width, the increased level of prestress in the CFRP prestressed prism positively affected the maximum crack width. The deflection of concrete slabs reinforced with CFRP prestressed prisms decreased as prestress in the CFRP prestressed prism increased.

FEA Simulations on Water Absorption in Various Pre-Cracked Concretes (유한요소해석에 기반한 콘크리트 균열 조건에 따른 수분흡수 현상 분석)

  • Kim, Kun-Soo;Park, Ki-Tae;Kim, Jaehwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.68-75
    • /
    • 2021
  • This study performed simulating water absorption in various pre-cracked concretes. 2D-Finite Element Analysis (2D-FEA) model was developed based on experimental results on the amount of absorbed water in concrete with the exposure time. Results from the 2D-FEA showed that both crack width and crack depth strongly affect the amount of absorbed water in cracked concrete. In addition, water absorption rate is introduced and a predictive equation is suggested to estimate the rate in order to quantify the amount of absorbed water in cracked concrete. It was confirmed that water absorption in concrete having less than 150 mm crack depth was dominated as a main transport factor regardless of crack width. Therefore, considering that steel corrosion caused by chlorides dissolved in water mainly occurs in reinforced concrete structures, it is necessary that crack depth as well as crack width should be investigated in reinforced concrete structures at the time of field-inspection.

A Study for the Fatigue Crack Growth Behavior of Concrete (콘크리트의 피로균열 성장거동에 관한 연구)

  • 김진근;김윤용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.101-107
    • /
    • 1996
  • In this study, the wedge splitting test (WST) specimens with various strength levels were tested to investigate the fatigue crack growth behavior of concrete. Selected test variables were concrete compressive strength with 2 levels (28 MPa, 60 MPa, 100 MPa) and maximum fatigue loading with 2 levels (75%, 85%). Fatigue testing was preceded by fracture energy test and the crack growth was measured by means of the compliance calibration method, 60 WST specimens were cast for the fatigue test, and 6 companion cylinders ($\phi$100${\times}$ 200 mm) for each batch. In fatigue test, the frequency of loading cycle was 1 Hz, and the minimum fatigue loading level was 5~10 % of ultimate monotonic loading. On the basis of the experimental results, a fracture mechanics-based empirical relationships for fatigue crack growth rate (da/dN-$\Delta$KI relationships) were presented. In addition, the effect of initial notch depth on the fracture energy and the validity of compliance calibration technique for the WST were shown.

  • PDF

Structural Behavior of Reinforced Concrete Continuous Deep Beams with Reinforcement around Opening (개구부 보강철근을 갖는 철근콘크리트 연속 깊은 보의 구조적 거동)

  • Yang, Keun-Hyeok;Hong, Seong-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.378-381
    • /
    • 2006
  • Test results of four reinforced concrete two-span continuous deep beams are summarized. Main variables were the configuration of web opening reinforcement. Shear span-to-overall depth ratio and the size of the web opening were fixed by 1.0 and 0.5 a $\times$ 0.2 h, respectively. To control diagonal crack and enhance strength, it can be recommended that diagonal reinforcement crossing the crack plane joining between loading points and corner of openings should be provided.

  • PDF

Assessment of Fracture Behaviors for CIP Anchors Fastened to Cracked and Uncracked Concretes

  • Yoon, Young-Soo;Kim, Ho-Seop;Kim, Sang-Yun
    • KCI Concrete Journal
    • /
    • v.13 no.2
    • /
    • pp.33-41
    • /
    • 2001
  • This paper presents the crack effect on CIP anchors and prediction of tensile capacity, as governed by concrete cone failure. Single anchors where located at center of concrete specimen. Three different types of cracks such as crack width of 0.2 mm and 0.5 mm, crack depth of 10 cm and 20cm , and crack location of center and off-center point were simulated. Static tensile load was applied to 7/8-in. CIP anchors of 10 cm and 20 cm embedment length in concrete with compressive strength of 280 kgf/$\textrm{cm}^2$. Tested pullout capacities were compared to the values determined using current design methods (such as ACI 349-97, ACI 349 revision and CEB-FIP which is based on CCD Method). The comparison of CCD Method and ACI revision showed almost the same values in uncracked concrete specimen. In cracked concrete, CCD Method predicted conservative values. Three-dimensional non-linear FEM modeling also has been performed to determine the stresses distribution and crack inclination.

  • PDF

Evaluation of Crack Propagation and Post-cracking Hinge-type Behavior in the Flexural Response of Steel Fiber Reinforced Concrete

  • Gali, Sahith;Subramaniam, Kolluru V.L.
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.2
    • /
    • pp.365-375
    • /
    • 2017
  • An experimental evaluation of crack propagation and post-cracking behavior in steel fiber reinforced concrete (SFRC) beams, using full-field displacements obtained from the digital image correlation technique is presented. Surface displacements and strains during the fracture test of notched SFRC beams with volume fractions ($V_f$) of steel fibers equal to 0.5 and 0.75% are analyzed. An analysis procedure for determining the crack opening width over the depth of the beam during crack propagation in the flexure test is presented. The crack opening width is established as a function of the crack tip opening displacement and the residual flexural strength of SFRC beams. The softening in the post-peak load response is associated with the rapid surface crack propagation for small increases in crack tip opening displacement. The load recovery in the flexural response of SFRC is associated with a hinge-type behavior in the beam. For the stress gradient produced by flexure, the hinge is established before load recovery is initiated. The resistance provided by the fibers to the opening of the hinge produces the load recovery in the flexural response.

Evaluating the Depth of a Surface-opening Crack in Concrete Slabs using Surface wave Measurements (표면파 측정을 통한 콘크리트 슬래브의 표면균열 깊이 측정)

  • Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.104-112
    • /
    • 2015
  • Non-contact surface wave transmission (SWT) measurements are used to evaluate the depth of a surface-breaking crack in concrete slabs. The author propose a measurement model that includes an appropriate configuration of the source and receivers, and a transmission function for the given configuration. A series of numerical simulations using a 3D finite element model is used to obtain the transmission function. Then, validity of a proposed model is verified through experimental studies. Two air-coupled sensors are used to measured surface waves across surface-breaking cracks with varying depths from 0mm to 100mm with intervals of 10mm in a concrete slab ($1500{\times}1500{\times}180mm^3$) in laboratory. As a result, the proposed method is demonstrated as to be effective for charactering the depth of a surface-breaking crack in concrete bridge deck with an average error of 10%. A discussion on practical applications of the proposed method is also included in this article.

Case Study of Flexural Strength Evaluation of Epoxy Injected Concrete Using Low Pressure Mixed with Mechanical High Pressure (기계식 고압과 저압을 혼용한 에폭시 주입 콘크리트의 휨강도 검토 사례 연구)

  • Hong, Ki-Nam;Yu, Yeon-Jong;Lee, Kang-Moon;Ryu, Chang-Yeol;Yoon, Hong-Su
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.49-54
    • /
    • 2012
  • The objective of this study is to investigate the capacity of epoxy injection method using low pressure mixed with high pressure. Injection depth test and flexural strength test were respectively performed on $40{\times}45{\times}35$ cm and $100{\times}10{\times}40$ cm specimens. Considered as the test variables were injection type(low pressure, low and high pressure), crack width(0.25 mm, 0.50 mm), injection direction(upper, lower, side), and epoxy viscosity(low, medium, high). Test results showed that low viscosity epoxy injection depth of injector using low pressure mixed with high pressure for upper direction were 23 cm and tension strength of crack face repaired by injector using low pressure mixed with high pressure was larger than that of concrete.

Finite element analysis of shear critical prestressed SFRC beams

  • Thomas, Job;Ramaswamy, Ananth
    • Computers and Concrete
    • /
    • v.3 no.1
    • /
    • pp.65-77
    • /
    • 2006
  • This study reports the details of the finite element analysis of eleven shear critical partially prestressed concrete T-beams having steel fibers over partial or full depth. Prestressed concrete T-beams having a shear span to depth ratio of 2.65 and 1.59 and failing in the shear have been analyzed using 'ANSYS'. The 'ANSYS' model accounts for the nonlinear phenomenon, such as, bond-slip of longitudinal reinforcements, post-cracking tensile stiffness of the concrete, stress transfer across the cracked blocks of the concrete and load sustenance through the bridging of steel fibers at crack interface. The concrete is modeled using 'SOLID65'-eight-node brick element, which is capable of simulating the cracking and crushing behavior of brittle materials. The reinforcements such as deformed bars, prestressing wires and steel fibers have been modeled discretely using 'LINK8' - 3D spar element. The slip between the reinforcement (rebar, fibers) and the concrete has been modeled using a 'COMBIN39'-non-linear spring element connecting the nodes of the 'LINK8' element representing the reinforcement and nodes of the 'SOLID65' elements representing the concrete. The 'ANSYS' model correctly predicted the diagonal tension failure and shear compression failure of prestressed concrete beams observed in the experiment. The capability of the model to capture the critical crack regions, loads and deflections for various types of shear failures in prestressed concrete beam has been illustrated.

Prediction of Durability for RC Columns with Crack and Joint under Carbonation Based on Probabilistic Approach

  • Kwon, Seung-Jun;Na, Ung-Jin
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.1
    • /
    • pp.11-18
    • /
    • 2011
  • Carbonation in RC (reinforced concrete) structure is considered as one of the most critical deteriorations in urban cities. Although RC column has one mix condition, carbonation depth is measured spatially differently due to its various environmental and internal conditions such as sound, cracked, and joint concrete. In this paper, field investigation was performed for 27 RC columns subjected to carbonation for eighteen years. Through this investigation, carbonation distribution in sound, cracked, and joint concrete were derived with crack mappings. Considering each related area and calculated PDF (probability of durability failure) of sound, cracked, and joint concrete through Monte Carlo Simulation (MCS), repairing timings for RC columns are derived based on several IPDF (intended probability of durability failure) of 1, 3, and 5%. The technique of equivalent probability including carbonation behaviors which are obtained from different conditions can provide the reasonable repairing strategy and the priority order for repairing in a given traffic service area.