• Title/Summary/Keyword: Concept of Protection

Search Result 528, Processing Time 0.022 seconds

Analysis on Satellite Uplink Interference for Satellite/Terrestrial Integrated System (위성/지상 겸용망에서 위성 업링크 간섭 분석)

  • Kang, Kunseok;Hong, Tae Chul;Kim, Hee Wook;Ku, Bon-Jun;Chang, Dae-Ig
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • The satellite 2.1 GHz frequency bands, 1980-2010 MHz and 2170-2200MHz are allocated for mobile satellite service including satellite IMT, while it does not preclude the use of these bands for mobile services. The concept of an integrated satellite/terrestrial network has been introduced in worldwide because the terrestrial use in these bands adjacent to existing terrestrial IMT bands is attractive to provide mobile broadband services. The integrated satellite/terrestrial infrastructure with a high degree of spectrum utilization efficiency has the ability to provide both multimedia broadband services and public protection and disaster relief solutions. In addition, it is required to consider interference issues between the terrestrial and satellite components in order to reuse the same frequency band to both satellite and terrestrial component. This paper analyzes the interference for satellite uplink in the satellite/terrestrial integrated system and the interference reduction scheme for satellite uplink interfered by terrestrial user equipment.

Interference Mitigation Techniques for Satellite Downlink in Satellite and Terrestrial Integrated System (위성/지상 겸용망에서 위성 다운링크 수신 단말 간섭 완화 기법)

  • Kang, Kunseok;Hong, Tae Chul;Kim, Hee Wook;Ku, Bon-Jun
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.81-88
    • /
    • 2013
  • The satellite 2.1 GHz frequency bands, 1980-2010 MHz and 2170-2200MHz are allocated for mobile satellite service including satellite IMT, while it does not preclude the use of these bands for mobile services. The concept of an integrated satellite/terrestrial network has been introduced in worldwide because the terrestrial use in these bands adjacent to existing terrestrial IMT bands is attractive to provide mobile broadband services. The integrated satellite/terrestrial infrastructure with a high degree of spectrum utilization efficiency has the ability to provide both multimedia broadband services and public protection and disaster relief solutions. In addition, it is required to consider interference issues between the terrestrial and satellite components in order to reuse the same frequency band to both satellite and terrestrial component. This paper analyzes the interference for satellite downlink in the satellite/terrestrial integrated system and presents the interference mitigation techniques for satellite mobile earth station interfered by terrestrial base stations.

GBAS Flight Testing and Performance Assessment using Flight Inspection Aircraft at Gimpo International Airport (비행검사용 항공기를 이용한 김포국제공항 GBAS 비행시험 및 성능평가)

  • Jeong, Myeong-Sook;Bae, Joongwon;Jun, Hyang-Sig;Lee, Young Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.1
    • /
    • pp.49-61
    • /
    • 2015
  • Ground Based Augmentation System(GBAS) is a system that offers an aircraft within 23 NM radius from the airport precision positioning service and precision approach service using the concept of Differential Global Positioning System(DGPS). After GBAS ground equipment installing at the airport, functionalities and performances of GBAS should be verified through the GBAS ground and flight testing. This paper describes the methods and results for GBAS flight test using the flight inspection aircraft at Gimpo International Airport. From the test results, we confirmed that the VDB data was received without misleading within the VDB coverage of Gimpo International Airport, and VDB field strength, protection level, and course alignment accuracy met the evaluation's criteria.

Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors

  • Kwon, Seog-Guen;Kim, Kyung-Eung;Ha, Chung-Woo;Moon, Philip S.;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.171-179
    • /
    • 1980
  • This paper presentss flux-to-dose conversion factors for neutrons and gamma-rays based on the concept of the maximum absorbed dose. Neutron flux-to-does-rate conversion factors for energies from 2.5$\times$10$^{-8}$ to 20 MeV are presented while the conversion factors for gamma-rays are given in the energy range of 0.01 to 15MeV. Flux-to-does-rate conversion factors, which were calculated under the assumption that the radiation energy distribution has nonlinearity in phantom, are different from those values obtained by monoenergetic radiation. Especially, these values obtained here were determined for the cross section libray such as DLC-23, DLC-27, and DLC-31. The flux-to-dose-rate conversion factors obtained in this work are in a good agreement with the values presented by American National Standard Institute (ANSI) N666. These results are used to calculate the dose rate distribution of neutron and gamma-ray in any radiation fields, and will be useful for the radiation shielding analysis, radiation protection and radiation dosimetry concerned with problems of continuous energy distribution.

  • PDF

A Preliminary Design Concept of the HYPER System

  • Park, Won S.;Tae Y. Song;Lee, Byoung O.;Park, Chang K.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.42-59
    • /
    • 2002
  • In order to transmute long-lived radioactive nuclides such as transuranics(TRU), Tc-99, and I- l29 in LWR spent fuel, a preliminary conceptual design study has been performed for the accelerator driven subcritical reactor system, called HYPER(Hybrid Power Extraction Reactor) The core has a hybrid neutron energy spectrum: fast and thermal neutrons for the transmutation of TRU and fission products, respectively. TRU is loaded into the HYPER core as a TRU-Zr metal form because a metal type fuel has very good compatibility with the pyre- chemical process which retains the self-protection of transuranics at all times. On the other hand, Tc-99 and I-129 are loaded as pure technetium metal and sodium iodide, respectively. Pb-Bi is chosen as a primary coolant because Pb-Bi can be a good spallation target and produce a very hard neutron energy spectrum. As a result, the HYPER system does not have any independent spallation target system. 9Cr-2WVTa is used as a window material because an advanced ferritic/martensitic steel is known to have a good performance under a highly corrosive and radiation environment. The support ratios of the HYPER system are about 4∼5 for TRU, Tc-99, and I-129. Therefore, a radiologically clean nuclear power, i.e. zero net production of TRU, Tc-99 and I-129 can be achieved by combining 4 ∼5 LWRs with one HYPER system. In addition, the HYPER system, having good proliferation resistance and high nuclear waste transmutation capability, is believed to provide a breakthrough to the spent fuel problems the nuclear industry is faced with.

A Study on the Concept and Protection System for the Geographical Indication (지리적 표시제도의 의의 및 보호체제 연구)

  • Go, Yong-Bu
    • Journal of Korea Port Economic Association
    • /
    • v.23 no.3
    • /
    • pp.165-184
    • /
    • 2007
  • This study reviews the concept and protection system for the geographical Indication(GI) to support the Korea-EU FTA. A geographical indication(GI) is a name or sign used on certain products or which corresponds to a specific geographical indication or origin (eg. a town, region, or country). The use of a GI may act as a certification that the product possesses certain qualities, or enjoys a certain reputation, due to its geographical origin. In the WTO Agreement on Trade-Related Aspects of Intellectual property Rights("TRIPS"). There are, in effect, two basic obligations from Article 22 to article 23 on WTO member governments relating to GIs in the TRIPS agreement. Geographical Indications have long been associated with Europe as an entity, where there is a tradition of associating certain food products with particular regions, Under European Union Law, the protected designation of origin system which came into effect in 1992 and 2003 regulates the following geographical indications: Protected designation of origin(PDO) and protected geographical indication(PGI) and Traditional Specialty Guaranteed(TSG). They have 5,000 articles for GI. We have the GI system and 40 articles rotating to registration by the law for quality management of production in agriculture. Cinclusinally, geographical indications could potentially serve as tools to helf holders of trade benefit more equitable through the mutual Acceptance for Korea-EU FTA.

  • PDF

Study on Radioactive Material Management Plan and Environmental Analysis of Water (I) Study of Radioactive Substances in Water Management and Analysis to Eat of the US Environmental Protection Agency (Envirionmental Protection Agency) (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (I) 미국환경보호청(Envirionmental Protection Agency)의 먹는 물 방사성물질 관리와 분석법에 관한 고찰)

  • Her, Jae;Kim, Jung-Min;Min, Hye-Lim;Han, Seong-Gyu;Lim, Hyun-Jong;Jo, Han-Byeol;Noh, Young-Hoon;Lee, Ho-Sun;Park, Min-Suk
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.163-170
    • /
    • 2015
  • The interest of the people in the radioactive contamination of the water has increased significantly and the study about analysis and management of radioactive materials are being actively conducted. And monitoring spots have been expanded to the range of public water as well as drinking water by publishing the rule of drinking water quality standards and examination in the Environmental Enforcement Ordinance No. 553 of Korea. In this study, US EPA was investigated as the foreign advanced cases and the way that is appropriate for the Korea was sought by analyzing investigate radionuclide, interval and management. As a result, in the selection part of investigate radionuclide, geological survey, status of nuclear power plants and the presence of the use of artificial radionuclides of the Korea should be investigated and additionally after the selection of a few radionuclides, the systems should be extended to cover all possible radionuclides by considering radioactive pollution levels in humans may be exposed due to the annual drinking water. In the part of the investigate interval, the concept(MCL, DL) should be set up for preventing concentration detection of above MCL and it needs to the maintenance and management. For example, when the concentration is more than MCL, it should be investigated on a quarterly and when the concentration is lower than MCL, it should be investigated to each different interval and management. And the US EPA divided the management area and make the roadmap for managing drinking water. The each classified area has been organized to match the state budget and labor force and the individual data have been managed effectively by HPGe, the NaI, TLD and so on.

A study on the location of fire fighting appliances in cargo ships (화물선 소화설비 비치에 대한 연구)

  • Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.852-858
    • /
    • 2016
  • To safeguard the accommodation spaces on cargo ships from fire, structural fire protection provisions introduced by SOLAS and these measures retard the propagation of flames and smoke. SOLAS also specifies provisions for fire fighting drills. These provisions are a combination of regulations regarding structure and equipment and those dealing with the human element for the fire protection and effective responses in the event of fire. Requirements related to the human element play a supporting role to the requirements for structure and equipment because the present accommodation structure and equipment are insufficient for extinguishing a fire, therefore, fire-extinguishing activity performed by crew members is essential. To reduce human error and ensure effective fire fighting, it is necessary to install a fire-fighting system and improve the fire fighting process. The fundamental concept of fire fighting exercises is to commence fire fighting before the fire grows too big to extinguish. It is essential to relocate the storage place of fire fighting equipment to expedite the fire-fighting exercise. This study was carried out to reduce human risk for this purpose, the fire control station was relocated to a site that could be accessed from the open deck. Further, two sets of a fire fighter's outfit were stored at the same site. This relocation eliminated the risk of the crew reentering to operate the fire fighting system in the fire control station and allowed the crew to pick up the fire fighters' outfits quickly in the event of a fire. In addition, it was proposed that the IIC method be made mandatory. This method is combination of automatic fire detection system and sprinkler system which can reduce the risk of the fire fighting exercises for the crew and to suppress fire in the initial stage. This study was carried out to provide a foundation to the possible amendment of the relevant SOLAS regulations and national legislation.

CYBERCRIME AS A THREAT TO UKRAINE'S NATIONAL SECURITY

  • Varenia, Nataliia;Avdoshyn, Ihor;Strelbytska, Lilia;Strelbytskyy, Mykola;Palchyk, Maksym
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.5
    • /
    • pp.73-83
    • /
    • 2021
  • The information space, the main components of which are information resources, means of information interaction, and information infrastructure, is a sphere of modern social life in which information communications play a leading role. The objective process is the gradual but stable entry of the national information space into the European and world information sphere, in the context of which there is a legitimate question of its protection as one of the components of the national security of Ukraine. However, the implementation of this issue in practice immediately faces the need to respect the rights and fundamental freedoms guaranteed by international regulations and the Constitution of Ukraine, especially in the field of cybersecurity. The peculiarity of the modern economy is related to its informational nature, which affects the sharp increase in cyber incidents in the field of information security, which is widespread and threatening and affects a wide range of private, corporate, and public interests. The problem of forming an effective information security system is exacerbated by the spread of cybercrime as a leading threat to information security both in Ukraine and around the world. The purpose of this study is to analyze the state of cybersecurity and on this basis to identify new areas of the fight against cybercrime in Ukraine. Methods: the study is based on an extensive regulatory framework, which primarily consists of regulatory acts of Ukraine. The main methods were inductions and deductions, generalizations, statistical, comparative, and system-structural analysis, grouping, descriptive statistics, interstate comparisons, and graphical methods. Results. It is noted that a very important component of Ukraine's national security is the concept of "information terrorism", which includes cyberterrorism and media terrorism that will require its introduction into the law. An assessment of the state of cybersecurity in Ukraine is given. Based on the trend analysis, further growth of cybercrimes was predicted, and ABC analysis showed the existence of problems in the field of security of payment systems. Insufficient accounting of cybercrime and the absence in the current legislation of all relevant components of cybersecurity does not allow the definition of a holistic system of counteraction. Therefore, the proposed new legal norms in the field of information security take into account modern research in the field of promising areas of information technology development and the latest algorithms for creating media content.

Study of Pro-environmental Development for Golf Course in Korea (한국 골프장의 친환경적 개발에 관한 연구)

  • 김광두
    • Asian Journal of Turfgrass Science
    • /
    • v.12 no.1
    • /
    • pp.49-78
    • /
    • 1998
  • Nowadays, there are increasing demands of golf courses and it is necessary to make more golf courses than the present. To do this, we need to improve the environmental problems with the regional inhabitants, and it is said that the first thing to be considered in developing any golf course in Korea is to preserve the environment. In this context, the purpose of this study is to set forth several design factors to lessen the negative impacts which are accompanied with the development of golf courses. 1. The present conditions of golf courses in Korea Many new golf courses have come into being, particularly since the late 1980s, and now, in the year of 1997, over one hundred of golf courses are doing their business, yet the number of golf course is still less than required. So far, over a half of them have been made in the vicinity of Seoul on account of various reasons, and this has adversely affected on our natural environment. This unreasonable development of golf courses has caused serious water pollution, landslides and the other problems. Also, the topography of Korea is not good for golf courses. Although the demands of golf courses are increasing, the suitable sites for them are very limited, and therefore it is sometimes unavoidable to make golf courses on steep hills. Consequently, in designing golf courses in Korea, the most important thing is the balance between natural environment and artificial environment. 2.Eco-friendly golf course design factors 1) The concept of eco-friendly golf courses Ecologically sustainable and sound golf courses which are made by eco-friendly approaches 2)Basic conditions of eco-friendly golf courses (1)The most suitable sites (2) Conservation of existing ground as much as possible (3)Proper use of agricultural chemicals which have great impacts on the environment (4) Reasonable use of fertilizers (5) Developing a specialized fertilizer only for grass (6) Adaptation of organic agriculture (7) Improvement of grass sorts (8) Establishing reservoirs for purifying the water from golf courses 3) Eco-friendly golf courses (1) Location-Enough area /Gentle slope/Winding ground/Including lakes or streams /Not crossing wind's main direction Facing south or southeast /Suitable soIl for grass /Good drainage /Low level of underground water (2)Course layout and design -Consideration about existing contours as much as possible -Adaptation of Scotish design trend -Various holes' configuration -Consideration toward surrounding landscapes -Reducing grass areas -Giving buffer zones -Adapting computer methods in the process of site analysis and design (3) Eco-friendly considerations in constructing and managing golf courses -Protection of wildlife -Reuse of existing forests and preservation of topsoil -Renovation of old-fashioned courses -Reducing grass areas -Purification of water -Standization of management -Strict regulations against chemicals -Recycling organic materials -Through separation of the water inside golf courses and out of bounds -Getting proper construction works done in a due time 4.Eco-friendly considerations from a viewpoint of cultural environment 1) Well-matched landscape design and events planning 2) Implement of identifications and awarding systerns 3)Acknowledgement of superintendents' qualitications in the maintenance of golf courses 4)Increasing public golf courses and keeping good relationships with the neighbors near golf courses Key words: Pro-environmental development, Golf course.

  • PDF