• 제목/요약/키워드: Concentration system

검색결과 8,170건 처리시간 0.039초

인공습지에 의한 농촌오수처리에 관한 연구 (Study on Natural Wastewater Treatment Systems by Constructed Wetland for Rural Area)

  • 윤춘경;권순국;김형중
    • 한국농공학회지
    • /
    • 제39권4호
    • /
    • pp.55-63
    • /
    • 1997
  • Constructed wetland system which can be applied to the rural wastewater treatment system was examined by pilot plant in Kon-Kuk University. Hydraulic loading rate of wastewater was about 0.16m$^3$/m$^2$. day and theoretical detention time in the system was 1.38 days. The effluent of the septic tank for the school building was applied as inflow to the system. The influent concentration of DO was zero but effluent was up to 4.37mg/${\ell}$ which implies that oxygen was supplied enough from atmosphere by reaeration to support biological activity of the system. Average influent concentration of BOD was 104mg/${\ell}$ and effluent was 24mg/${\ell}$ with average removal rate of 76%. Average influent concentration of COD was 215mg/${\ell}$ and effluent was 63mg/${\ell}$ with average removal rate of 70 % . Average influent concentration of SS was 78mg/${\ell}$ and effluent was 10mg/${\ell}$ with average removal rate of 87%. Two components, BOD and SS, are regulated by law to keep maximum water quality standard of 80mg/${\ell}$ when daily outflow rate is less than 100$m^3$/day which is the case of most rural communities. Therefore, the results from the experiment showed that constructed wetland system can meet the water quality standard easily. Average influent concentration of total nitrogen was 165mg/lwhich is relatively higher than normal wastewater, and effluent was about 156mg/${\ell}$ with average removal rate of only 6%. Average influent concentration of total phosphorus was 41 mg/${\ell}$ and effluent was 6mg/${\ell}$ with average removal rate of 87%. Overall, constructed wetland system was thought to be effective to treat wastewater if nitrogen removal mechanism is improved. Considering low cost, less maintenance, and high treatability, this system can be a practical alternative for the wastewater treatment in rural area The experiment was performed during the summer and fall season, and treatment efficiency of the system is expected to decrease in low temperature. therefore, further study including temperature is required to evaluate feasibility of the system more in detail.

  • PDF

박용 디젤기관의 $NO_x$ 및 매연 배출물에 미치는 스크러버형 EGR 시스템 재순환배기의 영향에 관한 연구 (A Study on Effects of Recirculated Exhaust Gas upon $NO_x$ and Soot Emissions of a Marine Diesel Engine with Scrubber EGR System)

  • 배명환;하정호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.70-78
    • /
    • 2000
  • The effects of recirculated exhaust gas on the characteristics of ;$NO_x$ and soot emissions under a wide range of engine load have been experimentally investigated by a water-cooled, four-cylinder, indirect injection, four cycle and marine diesel engine operating at two kinds of engine speeds. The purpose of the present study is to develop the EGR control system for reducing $NO_x$ and soot emissions simultaneously in diesel engines. The EGR system is used to reduce NOx emissions, and a novel diesel soot removal apparatus with a cylinder-type scrubber for the experiment system which has 6 water injectors(A water injector is made up 144 nozzles with 1.0mm in diameter) is specially designed and manufactured to reduce the soot contents in the recirculated exhaust gas to intake system of the engines. The intake oxygen concentration obtained by the intake air flow and the oxygen concentration in the recirculated exhaust gas, and the exhaust oxygen concentration measured in exhaust manifold are used to analyse and discuss the influences of EGR on NOx and soot emissions. The experiments are performed at the fixed fuel injection timing of $15.3^{\circ}$ BTDC regardless of experimental conditions. It is found that $NO_x$ emissions decrease and soot emissions increase owing to the drop of intake oxygen concentration and exhaust oxygen concentration as EGR rate rises. Also, one can conclude that it is sufficient for the scrubber EGR system with a novel diesel soot removal apparatus to reduce $NO_x$ emissions, but not to reduce soot emissions.

  • PDF

퍼지 클러스터링을 이용한 고농도오존예측 (Forecasting High-Level Ozone Concentration with Fuzzy Clustering)

  • 김재용;김성신;왕보현
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2001년도 춘계학술대회 학술발표 논문집
    • /
    • pp.191-194
    • /
    • 2001
  • The ozone forecasting systems have many problems because the mechanism of the ozone concentration is highly complex, nonlinear, and nonstationary. Also, the results of prediction are not a good performance so far, especially in the high-level ozone concentration. This paper describes the modeling method of the ozone prediction system using neuro-fuzzy approaches and fuzzy clustering. The dynamic polynomial neural network (DPNN) based upon a typical algorithm of GMDH (group method of data handling) is a useful method for data analysis, identification of nonlinear complex system, and prediction of a dynamical system.

  • PDF

DEVELOPMENT OF A METHOD FOR CONTROLLING GAS CONCENTRATION FOR USE IN C.A EXPERIMENTS

  • Yun, H.S.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.662-669
    • /
    • 2000
  • Based on the viscous flow characteristics of gas through capillary tube, a simple and low cost system was developed for controlling gas concentration for use in C.A experiments. The gas flow rate through capillary tube had a linear relationship with pressure, $(length)^{-1}$ and $(radius)^4$ of capillary tube, which agreed well with Hagen-Poiseuille's law. The developed system could control the gas concentration in storage chamber within ${\pm}0.3%$ deviation compared to the preset concentration. The required time for producing target gas concentration in storage chamber was exactly predicted by the model used in this study, and it required much longer time than the calculated time which divided the volume of chamber by flow rate. Therefore, for producing target gas concentration as quickly as possible, it needs to supply higher flow rate of gas during the initial stage of experiment when gas concentration in storage chamber has not reached at target value. It appeared that the developed system was very useful for C.A experiments. Because one could decide a desired flow rate by the prediction model, control flow rate freely and easily by changing pressure in the pressure-regulating chamber and the accuracy was high.

  • PDF

The Effect of Membership Concentration in FVQ/HMM for Speaker-Independent Speech Recognition

  • Lee, Chang-Young;Nam, Ho-Soo;Jung, Hyun-Seok;Lee, Chai-Bong
    • 음성과학
    • /
    • 제12권4호
    • /
    • pp.7-16
    • /
    • 2005
  • We investigate the effect of membership concentration on the performance of the speaker-independent recognition system by FVQ/HMM. For the membership function, we adopt the result obtained from the objective function approach by Bezdek. Membership concentration is done by varying the exponent in the membership function. The number of selected clusters is constrained to two for the sake of cheap computational cost. Experimental results showed that the recognition rate has its maximum value when the membership function was taken to be inversely proportional to the distance of the input vector from the cluster centroid. When the membership concentration was two weak or too strong, the performance was found to be relatively poor as expected. Except these extreme cases, the membership concentration was not shown to affect the recognition rate significantly. This is in accordance with the general observation that the fuzzy system is not much sensitive. to the detailed shape of the membership function as long as it is overlapped over multiple classes.

  • PDF

반도체 감광막 제거공정 적용을 위한 고농도 오존발생장치 개발 (Development on the High Concentration Ozone Generator System for the Semiconductor Photoresist Strip Process)

  • 손영수;함상용
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.591-596
    • /
    • 2006
  • we have been developed on the ultra high concentration ozone generator system which is the core technology in the realization of the semiconductor photoresist strip process using the ozone-vapor chemistry. The proposed ozone generator system has the structure of the surface discharge type which adopt the high purity ceramic dielectric tube. We investigate the performance of the proposed ozone generator system experimentally and the results show that the system has very high ozone concentration characteristics of $19.7[wt%/O_2]$ at the flow rate of $0.3[{\ell}/min]$ of each discharge cell. As a result of the silicon wafer photoresist strip test, we obtained the strip rate of about 400[nm/min] at the ozone concentration of $16[wt%/O_2]$ and flow rate of $8[{\ell}/min]$. So, we confirmed that it's possible to use the proposed high concentration ozone generator system for the ozone-vapor photoresist strip process in the semiconductor and FPD industry.

산세라인 자동화를 위한 농도 측정 시스템 개발 (Development of a Concentration Measurement System for Pickling Line Control)

  • 박형국;이종현;노일환
    • 제어로봇시스템학회논문지
    • /
    • 제19권10호
    • /
    • pp.891-895
    • /
    • 2013
  • This paper proposes the development of a new method for online analysis which measured acid concentration in a pickling line. Pickling is the most important step to remove surface scale layers and is strongly depending on the exactly controlled pickling liquor composition. Today, there is no feasible system available for the online control of pickling lines. Within this paper, new methods for online analysis of pickling liquors have been tested and implemented into an overall pickling process control tool. This method measured simultaneously the hydrochloric acid and iron ion concentration in a solution of hydrochloric acid by measuring the ultrasonic speed, the solution temperature, and the electrical conductivity. Experimental results showed excellent precision and the measurement error was ${\pm}2g/l$ compared with the neutralization titration measurement.

Concentration of CCCP Should Be Optimized to Detect the Efflux System in Quinolone-Susceptible Escherichia coli

  • Hyengun Cho;Yoojung Oh;Park, Seohyung;Lee, Yeonhee
    • Journal of Microbiology
    • /
    • 제39권1호
    • /
    • pp.62-66
    • /
    • 2001
  • Unlike eukaryotic efflux pumps energized by ATPase bacterial efflux pumps are energized by the proton motive force. That is the reason why CCCP, an inhibitor of proton motive forcer is widely used to study the bacterial efflux pump. In many cases, efflux systems have been observed only in quinolone-resistant bacteria. Most of the quinolone-susceptible strains have been found to maintain little efflux pump. However some susceptible bacteria skewed the increased intracellular quinolone concentration only at a low concentration (0.01 or 0.1 mM) but net at a high concentration (1 mM) of CCCP. If bacterial cells were killed at high concentrations of CCCP and lost the integrity of their membranes, the intracellular quinolone would leak out from cells with no efflux system. The efflux pump system in the quinolone-susceptible strains could net be detected at the same concentration used for resistant bacteria. To test this hypothesist the intracellular quinolone concentration in the quinolone-susceptible and -resistant strains of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus was assayed at various concentrations of CCCP. Since the effect of CCCP is very rapid, the survival of bacteria was observed by assaying the DNA synthesis in 5 min. In the case of E. coli, but not P. aeruginosa or S. aureus, the quinolone susceptible strain was more susceptible to CCCP than the quinolone resistant ones, especially when the incubation with CCCP was extended. Decrease of the intracellular quinolone concentration resulted in a false result-no or weak efflux system in the quinolone susceptible strains. Results suggested that the concentration of CCCP should be optimized in order to detect the efflux system in the quinolone susceptible strains of E. coli.

  • PDF

유역하수도 공공하수처리시설의 방류수 수질 준수농도 설정방안 연구: 진위천 수계를 중심으로 (A study on Determination Method of the Compliance Concentration of Effluent Limitation from Public Sewage Treatment Works in the Jinwee-stream Watershed Sewer System)

  • 정동환;조양석;김영석;안경희;정현미;권오상
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.493-502
    • /
    • 2015
  • In accordance with the Watershed Sewer System Maintenance Plan enforced on February 2, 2013, the different compliance concentration of effluent limit be applied to effluent discharged from public sewage treatment works(PSTWs) in each watershed on the basis of water quality thereof. With the introduction of watershed sewer system, it is necessary to set the compliance concentration of effluent limit for PSTWs situated in the watershed, by region and PSTW size, to achieve water quality criteria for regional watersheds or target water quality under TMDL program. Watershed Environmental Agencies establish the Watershed Sewer System Maintenance Plan and set the compliance concentrations of effluent limit for PSTWs under the plan. The agencies plan to apply tougher effluent BOD concentration limits in Class I to IV areas. Effluent BOD concentration limits will be toughened from 5~10 mg/L to 3 mg/L in class II~III areas, from 10mg/L to 5mg/L in class IV areas. Uniform application of effluent BOD concentration limits to PSTWs in the watershed sewer system need to be complemented considering type of sewage treatment technology employed and watershed characteristics. Therefore, this study presents method to determine the compliance concentration of effluent limit from PSTWs in the watershed.

반도체레이져를 이용한 온도 및 농도의 계측 (Temperature and Concentration measurement using Semi-conductor diode laser)

  • 정대헌;노동순;지전유이
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.168-174
    • /
    • 2000
  • A diode laser sensor system based on absorption spectroscopy techniques has been developed to measure $CO_2$ concentration and temperature non-intrusively in high temperature combustion environments using a 2.0 ${\mu}m$ DFB(Distributed Feedback) laser. Two optics was fabricated in pig-tail fashion and all optical components were implemented in a single box. The evolution of measurement sensitivity was done using test cell by changing sweep frequency and $CO_2$ concentration. Gas temperature was determined from the ratio of integrated line strengths. Species concentration was determined from the integrated line intensity and the measured temperature. The result show that the system has 2% error in wide operation frequency range and accuracy of $CO_2$ concentration was about 3%. The system was applied to measure temperature and concentration in the combustion region of a premixed $CH_4$ +air triangular flame. The measurement results of gas temperature agreed well with thermocouple results. Many considerations were taken into account to reduce optical noise, etalon effect, beam steering and base line matching problem. The evaluations results and actual combustion measurement demonstrate the practical and applicability for in-situ and real time combustion monitoring in a practical system.

  • PDF