• Title/Summary/Keyword: Concentration limit

Search Result 1,505, Processing Time 0.028 seconds

Fabrication and characteristics of limit-current type oxygen sensor with monolith aperture structure (일체화된 Aperture 구조의 한계전류형 산소센서의 제작 및 특성)

  • Oh, Young-Jei;Lee, Deuk Yong
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.273-280
    • /
    • 2008
  • Monolith aperture-type oxygen sensors with simple structure of YSZ(pin-hole)/Pt/ YSZ(solid electrolyte)/Pt were fabricated by co-firing technique. To enhance the yield of productivity, a couple of YSZ green sheets for diffused barrier and solid electrolyte were prepared by tape-casting and co-firing method. The limit current characteristics of the oxygen sensors were measured between 500 and $650^{\circ}C$ The heating temperature of $600^{\circ}C$ was optimum as a portable oxygen sensor in the range of oxygen concentration from 0 to 75 vol%. Linear proficiency of limit current behavior as a function of oxygen concentration was controlled by the variation of aperture dimension. The fabricated oxygen sensors showed the stable sensing output for 30 days. Gas leakage in bonding area due to warping, cracking and thermal cycling was not found in the period.

Quality Control on the BOD, COD, TN, TP of Water Quality Pollutant (수질오염물질 BOD, COD, TN, TP의 정도관리(I))

  • Park, Sun-Ku;Kim, Tae-Seung;Ryu, Jae-Kyun
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.312-317
    • /
    • 1999
  • Quality control was carried out the three analytes, BOD, COD, TN, TP of high and low concentration for thirteen laboratories. Evaluation values of Quality control was determined from average value which were made by six times test, repeatedly and periodically. This value had not only error ratio of within 5% from prepared sample value but also high precision of standard deviation, 0.44 (BOD, low concentration), 2.15 (BOD, high concentration), 0.12 (COD, low concentration), 1.63 (COD, high concentration), 0.35 (TN, low concentration), 1.99 (TN, high concentration), 0.05 (TP, low concentration), 0.14 (TP, high concentration). Upper (Lower) Warning Limit (ULWL) and Upper (Lower) Acceptance Limit (ULAL) values made from quality control chart. Three (5.30, 9.70, 5.30 mg/L) and five laboratories were over ULAL value in low and high BOD concentration, respectively. Two (41.00, 30.60 mg/L) and four laboratories were over ULAL value in low and high COD concentration, respectively. while, other eleven laboratories appeared reliable data. One laboratory (0.70 mg/L) was over ULAL at low TN concentration, while other eleven laboratories had reliable values. In case of high TN concentration, eleven laboratories were over ULAL value, it should be focuced for improvement of reliability about measurement and analysis of TN. Four (1.14, 0.45, 0.64, 1.49mg/L) and seven laboratories were over ULAL in low and high TP concentration, respectively.

  • PDF

The effects of oxygen-concentration increased by oxygen-enriching membrane on combustion of S.I. engines (기체분리막에 의해 상승된 산소농도가 스파크점화기관의 연소에 미치는 영향)

  • 권병철;김형섭
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.74-80
    • /
    • 1992
  • The purpose of this study is to improve the performance of gasoline engine. Combustion-characteristics orignated from supplying cylinder with fuel-air mixture which was formed by the rise of oxygen-concentration in air with oxygen-enriching membrane have been investigated. The results showed that the poor-limit of oxygen-concentration was increased by shortening combustion-duration because the rise of oxygen-concentration in fuel-air mixture resulted in the promotion of combustion-velocity. Also, the generation of large output of power was expected from combustion in proportion as the amount of oxygen was increased.

  • PDF

A Study on Heavy Metal Pollution in Mongolia Boroo Soil (몽골 버러지역 토양의 중금속 오염 현황 조사)

  • Park, Juhyun;Park, Jayhyun;Kim, Takhyun;Yeon, Gyuhun
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.5
    • /
    • pp.17-25
    • /
    • 2018
  • The Boroo area in Mongolia is known to have been contaminated with heavy metals due to irregular gold mining activities and the release of mercury from gold extraction process. Soil and mine tailings were collected to analyze contamination patterns of heavy metals in the Boroo area. Analyses revealed that mercury, arsenic and cadmium concentrations exceeded the regulatory standard of the nation (Mongolia National Standard). In case of mercury, about 80% of the survey area was over the limit and the concentration distribution heavily influenced by influx of mercury through water transport. Soil contamination by arsenic was most severe that the concentration exceeded the regulatory limit in almost entire survey area, showing peak concentrations at nearby streams and river along with ore processing facilities. For cadmium, about 20% of the survey area was over the limit with the concentration distribution similar to that of arsenic.

A Study on the Limit Capacity Calculation for Thermal plant based on Air Pollution Control (대기오염에 따른 화력발전소의 한계용량산전에 관한 연구)

  • Yim Han Suck
    • 전기의세계
    • /
    • v.26 no.2
    • /
    • pp.95-98
    • /
    • 1977
  • Commercially available fuel oil for power plant contains relatively much sulphur, which means accordingly high content sulphur deoxide in exhaust gas. Sulphur deoxide has been identified as the worst-pollutant caused by thermal power generation. This paper primarily deals with the stack gas diffusion effects of various parameters, namely vertical stability, wind velocity, exhaust gas velocity, stack height, etc., on the ground concentration. thereof the relation between stack height and maximum plant capacity is analyzed from the standpoint of air pollution prevention. The limit capacity is calculated by means of mean concentration introducing Mead and Lowry coefficient respectively.

  • PDF

Funnel Design Guidance (Funnel 설계 권고안)

  • Jeong, Wang-Jo;Cho, Won-Ho;Kang, Dae-Youl;Kim, Seung-Hyuk
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2006.09a
    • /
    • pp.59-64
    • /
    • 2006
  • Most important factor to consider funnel performance is exhaust gas temperature and exhaust gas concentration Electric equipments on the wheelhouse top affected exhaust gas temperature. So, it is important that electric equipments keep away from high temperature. Though exhaust gas concentration is not a regulation and restraint, the exhaust 9as can cause serious problems for the on-board air quality and result in irreversible damage to the ship and people. So, we pocus on the exhaust gas concentration also. When judge whether a measured concentration is acceptable or not, criteria based on the LTEL (Long Term Exposure Limit). In this paper, we carried out the smoke simulation study. For this analysis, we used FLUENT which is commercial CFD (Computational Fluid Dynamics) code.

  • PDF

A Study on the Comparison of Explosive Lower Limit Concentration & Thermal Specific of Wheat Powder Dust & Salicylic Acid Dust (밀가루분진 및 살리실산분진의 폭발하한농도 및 열적특성 비교에 관한 연구)

  • Ko, Jae-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • We have examined In order to compare each other from explosion and combustion characteristics about the dusts which collects from manufacturing process of wheat flour and cosmetics manufacturing process of functional Keratin removal soap at the small and medium enterprise style. We measured explosive pressure and explosive lower limit which follows in change of concentration change at the time of talc addition uses Hartman dust explosion apparatus, also measured weight loss and endothermic quantity uses DSC and TGA. The explosion test results show that increased explosive lower limit concentration and explosive pressure decreased by the increased ratio of the talc dust. And the DSC results show that heat flux and temperature decreased by the increased ratio of the talc dust. Also increased in raising temperature causes initial smoldering temperature to move towards low temperature section and the endothermic quantity increased on a large scale. Together the TGA results show that weight loss decreased by the increased ratio of the talc dust. From this research we have assured the successive dust explosion mechanism study will play a key role as a significant safety securing guideline against the dust explosion.

Proposal of Application Method for Concentration Averaging of Radioactive Waste in Korea by Using CA BTP of US NRC

  • Jiyoung Yi;Chang-Lak Kim
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.3
    • /
    • pp.347-357
    • /
    • 2023
  • United States Nuclear Regulatory Commission (U.S. NRC) specifies regulations on obtaining licenses and describes the technical position on the average waste concentration, also known as Concentration Averaging and Encapsulation Branch Technical Position (CA BTP); CA BTP helps classify blendable waste and discrete items and address concentration averaging. The technical position details are reviewed and compared in a real environment in Korea. A few cases of concentration averaging based on the application of CA BTP to domestic radioactive waste are presented, and the feasibility of the application is assessed. The radioactive waste considered herein does not satisfy the Disposal Concentration Limit (DCL) of the second-phase disposal facility while applying the preliminary classification. However, if CA BTP is applied when the radioactive waste is mixed with other radioactive waste items in a large and heavy container, it can be disposed of at the second-phase disposal facility in Gyeongju Repository. To apply the CA BTP of the U.S. NRC, it is necessary to investigate the safety assessment conditions of the US and Korea.

Performance Characteristics of In-Situ Particle Monitors at Sub-Atmospheric Pressure (감압상태에서의 In-Situ Particle Monitor의 성능특성)

  • Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1564-1570
    • /
    • 1998
  • In-situ particle monitors(ISPMs) are widely used for monitoring contaminant particles in vacuum-based semiconductor manufacturing equipment. In the present research, the performance of a Particle Measuring Systems(PMS) Vaculaz-2 ISPM at subatmospheric pressures has been studied. We created uniform upstream conditions of particle concentration and measured the detection efficiency, the lower detection limit, and the size response of the ISPM using uniform sized methylene blue aerosol particles. The effect of particle size, particle velocity, particle concentration, and system pressure on the detection efficiency was examined. Results show that the detection efficiency of the ISPM decreases with decreasing chamber pressure, and with increasing mass flow rate. The lower detection limit of the ISPM, determined at 50 % of the measured maximum detection efficiency, was found to be about $0.15{\sim}0.2{\mu}m$, which is similar to the minimum detectable size of $0.17{\mu}$ given by the manufacturer.

Changes in the Air Quality of Port Areas Following the Implementation of the IMO 2020 Sulfur Limit (IMO 2020 황산화물 규제에 따른 항만지역 대기질 변화 특성)

  • Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.30 no.11
    • /
    • pp.967-977
    • /
    • 2021
  • From January 1, 2020, the International Maritime Organization has implemented a global regulation, known as IMO 2020, to reduce the sulfur content in fuel oil of ships from 3.5% to 0.5%. In this study, we used data from air monitoring stations to evaluate the change in air quality at New Port and North Port in Korea areas after the regulation was implemented. The concentration of SO2 and NO2 was higher in the port areas than in the surrounding areas due to exhaust gas from ships and vehicles. However, the SO2 concentration decreased by more than 50% in the port area, demonstrating the efficiency and positive effect of the IMO 2020 sulfur limit.