• 제목/요약/키워드: Concentration efficiency

검색결과 4,575건 처리시간 0.046초

배기가스 재순환 방식이 예혼합 연소시스템에 미치는 영향 (The Effects of Exhaust Gas Recirculation on Premixed Combustion System)

  • 유병훈;이승로;금성민;이창언
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.1-3
    • /
    • 2013
  • The premixed combustion system applying exhaust gas recirculation was investigated to achieve the low pollutant emission and the high thermal efficiency. In this study, it was studied the effects of EGR on the thermal efficiency, $NO_x$ and CO emissions with various EGR ratios and equivalence ratios. As results, when equivalence ratio was increased, thermal efficiency increased and $NO_x$ and CO concentration increased. When EGR was applied, $NO_x$ and CO concentration decreased and thermal efficiency increased. Especially, in the case of 15% of EGR ratio at 0.85 of equivalence ratio, $NO_x$ and CO concentration will be a smaller than these of a current operating condition of the boiler and thermal efficiency was about 1.7% higher.

  • PDF

폐비닐 재활용 여재를 이용한 소규모 오수종말처리장의 효율검증 (Efficiency Verification of Small-Scale Sewage Treatment Plant Using Discussed Vinyl as Biofilm Media)

  • 임재명;김병욱;구본수
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.1-6
    • /
    • 1998
  • This study was conducted to use disused vinyl as biofilm for biological sewage treatment. Efficiency verification was performed on laboratory and on-site plant. In laboratory study, total biochemical oxygen demand(TBOD) removal rate was ranged 94.8~97 % in each hydraulic retention tim(HRT), 12, 16, 20, 24 hr, respectively. At that time, filling rate was 50 %. And effluent TBOD concentration was low ranged 3.64~6.28 mg/L. In on-site plant, TBOD removal rate was ranged 88.2~96.8 % and effluent TBOD concentration was 4.8~17.7mg/L. This concentration was lower than disign effluent concentration, 30mg/L. Total kjeldhal nitrogen(TKN) removal efficiency was ranged 56.8~90.9%. This was resulted higher than Lab. scale treatment efficiency.

  • PDF

Effect of Deposition Parameters on the Morphology and Electrochemical Behavior of Lead Dioxide

  • Hossain, Md Delowar;Mustafa, Chand Mohammad;Islam, Md Mayeedul
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권3호
    • /
    • pp.197-205
    • /
    • 2017
  • Lead dioxide thin films were electrodeposited on nickel substrate from acidic lead nitrate solution. Current efficiency and thickness measurements, cyclic voltammetry, AFM, SEM, and X-ray diffraction experiments were conducted on $PbO_2$ surface to elucidate the effect of lead nitrate concentration, current density, temperature on the morphology, chemical behavior, and crystal structure. Experimental results showed that deposition efficiency was affected by the current density and solution concentration. The film thickness was independent of current density when deposition from high $Pb(NO_3)_2$ concentration, while it decreased for low concentration and high current density deposition. On the other hand, deposition temperature had negative effect on current efficiency more for lower current density deposition. Cyclic voltammetric study revealed that comparatively more ${\beta}-PbO_2$ produced compact deposits when deposition was carried out from high $Pb(NO_3)_2$ concentration. Such compact films gave lower charge discharge current density during cycling. SEM and AFM studies showed that deposition of regular-size sharp-edge grains occurred for all deposition conditions. The grain size for high temperature and low concentration $Pb(NO_3)_2$ deposition was bigger than from low temperature and high concentration deposition conditions. While cycling converted all grains into loosely adhered flappy deposit with numerous pores. X-ray diffraction measurement indicates that high concentration, high temperature, and high current density favored ${\beta}-PbO_2$ deposition while ${\alpha}-PbO_2$ converted to ${\beta}-PbO_2$ together with some unconverted $PbSO_4$ during cycling in $H_2SO_4$.

특정크기 입자농축을 위한 대유량 슬릿형 2단 가상충돌기의 성능분석 (Analysis of High Volume Slit Type Two-Stage Virtual Impactor for Particle Size Classification)

  • 박성호;김상수;오명도
    • 대한기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.285-291
    • /
    • 1991
  • 본 연구에서는 800 1pm인 대유량을 처리하고 공기중 1.8~4.5$\mu\textrm{m}$ 입자를 효율 적으로 선별하여 농축시키는 슬릿형 2단 가상충돌기를 설계 제작하고 그 성능이 평가 되었다. 즉, 첫째단과 둘째단에서 4.5$\mu\textrm{m}$과 1.8$\mu\textrm{m}$이 각각 50%의 효율로 분리되도록 설계되었다. 즉, 첫째단과 둘째단에서 4.5$\mu\textrm{m}$과 1.8$\mu\textrm{m}$이 각각 50%의 효율로 분리되도 록 설계한다. 설계인자(design parameter)들을 결정하기 위하여 먼저 슬릿형 노즐의 1단 가상충돌기의 분리효율(separation efficiency)에 대한 실험을 통하여 50% 커트오 프 Stokes수를 구하고, 이를 기초로 하여 2단 가상 충돌기의 주요치수와 작동조건을 결정하였다.

Takahashi 구름모형에서의 얼음입자 충돌효율 개선 (Implementation of Improved Ice Particle Collision Efficiency in Takahashi Cloud Model)

  • 이한아;염성수
    • 대기
    • /
    • 제22권1호
    • /
    • pp.73-85
    • /
    • 2012
  • The collision efficiency data for collision between graupel or hail particles and cloud drops that take into account the differences of particle density are applied to the Takahashi cloud model. The original setting assumes that graupel or hail collision efficiency is the same as that of the cloud drops of the same volume. The Takahashi cloud model is run with the new collision efficiency data and the results are compared with those with the original. As an initial condition, a thermodynamic profile that can initiate strong convection is provided. Three different CCN concentration values and therefore three initial cloud drop spectra are prescribed that represent maritime (CCN concentration = 300 $cm^{-3}$), continental (1000 $cm^{-3}$) and extreme continental (5000 $cm^{-3}$) air masses to examine the aerosol effects on cloud and precipitation development. Increase of CCN concentration causes cloud drop sizes to decrease and cloud drop concentrations to increase. However, the concentration of ice particles decreases with the increase of CCN concentration because small drops are difficult to freeze. These general trends are well captured by both model runs (one with the new collision efficiency data and the other with the original) but there are significant differences: with the new data, the development of cloud and raindrop formation are delayed by (1) decrease of ice collision efficiency, (2) decrease of latent heat from riming process and (3) decrease of ice crystals generated by ice multiplication. These results indicate that the model run with the original collision efficiency data overestimates precipitation rates.

DO농도 조절에 따른 황 충전 섬모상 반응조의 질소제거 성능 변화 (Nitrogen Removal Performance at Various DO Concentrations in the Bioreactor Packed with Submerged Cilia Media and Granular Sulfur)

  • 문진영;황용우
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.519-526
    • /
    • 2006
  • In this study, the major operating factors in SND(simultaneous nitrification and denitrification) using bioreactor packed with submerged cilia media and granular sulfur such as variation of nitrification rate, organic matter removal efficiency and denitrification efficiency in different DO concentration were mainly evaluated. Synthetic wastewater and actual sewage were used as influent wastewater. Experiment with synthetic wastewater as influent wastewater was divided into three phases with the adjustment of DO concentration. As the results, nitrification efficiency and T-N removal efficiency in the Phase 3(DO 1.0~2.0 mg/L) were 99% and 52.3%, which is significantly greater than those in other two phases. Also, loading rate and denitrification efficiency of SCPGS(Submerged Cilia media Packed with Granular Sulfur) were calculated as $0.44kg\;NO_3^--N/m^3-day$ and 50%, respectively. On the other hand, nitrification rate was decreased from 99% to 64% according to the DO concentration with the variation from 3.0~3.5 mg/L(phase1) to 0.4~0.6mg/L(phase2). Although the nitrification rate was decreased in 64% according to the variation of the DO concentration, T-N removal rate was rapidly increased to 49% by increasing of the denitrification efficiency. Experiment with actual sewage as influent wastewater was carried out to evaluate efficiency of SCPGS in real operation condition of full-scale sewage water treatment plant. At the time, T-N removal rate in this experiment and full-scale wastewater treatment plants were given by 43% and 20%, respectively. The above results indicate that SCPGS can be used as an advanced treatment process for economical efficiency considered.

제설제가 환경에 미치는 영향 연구 (A study of effects on environment from road deicings)

  • 신진호;허항록;신정식;김민영;신재영
    • 환경위생공학
    • /
    • 제16권4호
    • /
    • pp.31-37
    • /
    • 2001
  • Deicers have used for melting snow on the road during winter season, but they have largely influenced on environment and public assets and human health. The pollution level of snow and soil contained deicer was analyzed and evaluated the characteristics of deicers. The results were as follows 1. In the result of measurement of pollutants in snow contained deicer, the pH was a little higher than a comparative group and the concentration of $Cl^{-}$ ranged from 0.5% to 0.87%, and the electric conductivity ranged 12.4 to 24.6 mmho/cm. The concentration of Cd, As, and Hg was not detected, but those of Cu, Pb, Cr was higher than a comparative group. 2. In soil of the road spreaded with deicer, the pH is getting alkalized and the concentration of $Cl^{-}$ was high in January and returned the level of a comparative grout) in November by physical and chemical reaction with deicer, but the concentration of heavy metals were not connected with deicers. 3. In comparison of deicing efficiency, the concentration of $Cl^{-}$ was 3.3~5times high in spreading with deicer before snowing than after snowing. The concentration of $Cl^{-}$ in NaCl was higher than $CaCl_2$, but the deicing efficiency of Nacl was better than that of $CaCl_2$. Moreover, the new deicer have no salt, but deicing efficiency of new deicer was less than that of NaCl and $CaCl_2$.

  • PDF

High Level O2배가스중 NO 저감에 대한 선택적비촉매환원 반응특성에 관한 연구 (A Study on Characteristic of NO Reduction by High Level O2Gas in Selective Non-Catalystic Reaction)

  • 이강우;정종현;오광중
    • 한국환경과학회지
    • /
    • 제11권6호
    • /
    • pp.577-582
    • /
    • 2002
  • Selective catalytic reduction and selective non-catalytic reduction processes are mainly used to treat nitrogen oxidants generated from fossil-fuel combustion. Especially, the selective non-catalytic reduction process can be operated more economical and designed more simply than the selective catalytic reduction. For this reason, many researchers carried out to increase the removal efficiency of nitrogen oxidants in the condition of low oxygen concentration by using the selective non-catalytic reduction process. However, this study was flue gas contained high oxygen concentration of 20(v/v%) with ammonia as a reducing agent. Moreover, it carried out experiment with many factors that are reaction temperature, retention time, initial NO concentration, NSR(normalized stoichiometric ratio). It was determined optimal operating conditions to improve NO removal efficiency with SNCR process. The De-NOx efficiency was increased with NSR, initial NO concentration and retention time increasement. This study has NO removal efficiency over 80% in the high oxygen concentration as well as low oxygen concentration. The injection of reducing agent may be considered for SNCR process and facility operation in 850$\^{C}$ of optimal condition.

하수중의 질소.인 제거를 위한 $A^2$/O공정의 적용 (Application of $A^2$/O Process for Removal of Nitrogen and Phosphorus in Sewage)

  • 안철우;박진식;문추연
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.9-14
    • /
    • 2000
  • In this study, the removal efficiencies of organics, nitrogens and phosphorus from municipal wastewater using $A^2$/O process were investigated. BO $D_{5}$ removal efficiencies were indicated 95% and 94% with HRT of 12 hr and 10 hr, respectively. CO $D_{Cr}$ average removal efficiency and concentration of effluent were indicated 87% and 34mg/$\ell$. SS average removal efficiency and concentration of effluent were indicated 93% and 4~17mg/$\ell$. T-N removal efficiency and concentration of effluent were shown as 60~80% and below 15mg/$\ell$. In aerobic basin, removal efficiency of N $H_4$-N was shown over 97% with N $H_4$-N volume load 0.16kg N $H_4$-N/㎥.d and in anoxic basin, denitrification efficiency was indicated over 80% with return sludge rate 0.5Q and internal recirculation rate 2.5Q. Removal efficiency and effluent concentration of phosphorus were shown over 80% and below 2 mg/$\ell$ with return sludge rate 0.5Q.Q.

  • PDF

고농도 니켈을 함유한 산업하수의 질산화율 분석 및 개선 방안 (Analysis and improvement measures of nitrification using industrial wastewater with high Nikel concentration)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제19권4호
    • /
    • pp.501-507
    • /
    • 2017
  • 산업하수 내 함유된 고농도 중금속(니켈)은 하수처리장 질산화율 감소의 원인으로 지목되고 있다. 본 연구에서는 고농도 니켈을 함유한 산업하수의 질산화율 분석 및 개선 방안을 도출하고자 실험실 규모 반응조 운전을 실시하였다. 운전 결과를 고농도 니켈을 함유한 경우 질산화율은 20% 내외로 낮은 범위를 보였지만, 저농도 니켈이 유입되었을 경우 질산화율이 향상(70% 이상)되었다. 질산화율의 차이를 보인 주요 원인은 니켈이 반응조 내 미생물의 활성을 감소시킨 것으로 AUR과 SNR 분석을 통해 나타났다. 또한 고농도 니켈이 유입될 경우, 체류시간 증가와 더불어 질산화율이 증가하였다. 즉, 고농도 중금속(니켈)을 함유한 하수의 경우 미생물 관리 및 체류시간 증가를 통해 안정적인 질산화율을 확보할 수 있을 것으로 판단된다.