• 제목/요약/키워드: Concentration distribution

검색결과 4,137건 처리시간 0.032초

Melatonin Suppression under LED Lighting Focused on Spectral Power Distribution Differences

  • Hong, Seong-Kwan;Kim, Kyoung-Sil;Kim, In-Tae;Choi, An-Seop
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.7-17
    • /
    • 2015
  • Changes in melatonin concentration levels by differences in CCT of white LED light focused on Spectral Power Distribution (SPD) differences compared to the same CCT of conventional fluorescent light were analyzed. For this, melatonin concentration levels in saliva samples were taken over four different experiments at seven-day intervals. In 71.4% of participants, it was confirmed that melatonin concentration is suppressed by exposure to light, and a slight difference was observed by different CCTs. In addition, Experiment II with a high CCT was relatively high in terms of the melatonin suppression rate compared to Experiment III. A key finding was the possibility that different SPDs under a particular CCT of white LED light compared to the same CCT of conventional fluorescent light could have the same effect on the melatonin suppression.

신장해에 의한 염기성약물의 분포용적감소예와 그 기전 (Decrease of Distribution Volume of a Basic Drug in Rats of Experimental Renal Failure)

  • 심창구
    • 약학회지
    • /
    • 제27권1호
    • /
    • pp.21-28
    • /
    • 1983
  • Distribution volume (Vd$_{ss}$ ) of a model basic drug, tetraethylammonium bromide (TEA) at a steady-state decreased sinificantly in glycerol and uranium-renal failure rats. Assuming carrier-mediated transport of TEA into tissues, the theoretical $Vd_{ss}$ of TEA decreases in an exponential way as the plasmal concentration of TEA increases. The relationship between $Vd_{ss}$ and plasma concentration of TEA in the experimental renal failure (ERF)-rats was similar. Therefore, the decrease in $Vd_{ss}$ of TEA in the ERF-rats seemed to be due to the saturation of the carrier system that are responsible for the tissue distribution of TEA, by the elevated plasma concentration of TEA in the ERF-rats. ERF was induced to rats with glycerol, folate, salicylate, uranium and gentamicin, respectively..

  • PDF

Distribution Characteristics of Dioxins in Marine Sediment from Busan Port in Korea

  • Jeong, Tae-Uk;Seo, Dong-Cheol;Jeong, Seung-Ryul;Song, Bok-Joo;Cho, Jeong-Gu;Yoo, Pyung-Jong;Kim, Gi-Gon;Cho, Ju-Sik;Heo, Jong-Soo
    • 한국토양비료학회지
    • /
    • 제45권1호
    • /
    • pp.107-111
    • /
    • 2012
  • Eight marine sediments from Busan port in Korea were annually analyzed to examine the concentration distribution of dioxins from 2006 to 2010. Yearly mean concentration of dioxins ranged from 186.3 to $383.3pg\;g^{-1}$ in real values and 5.087 to 8.541 pg-TEQ (Toxicity equivalency) based on dry weight of samples. The dioxin concentration at the site near fishing market was the highest concentration among all sampling sites. Also the dioxin concentration at the sites with various pollutant sources such as large ships, sewage influx and thermal power station as well as fishing market was higher than that of the sites without specific pollutant sources. Another main factor that affects the dioxin concentration is topography characteristics of the bay. The bay has relatively high dioxin concentration because of the lack of the pollutant diffusion. This study demonstrated that the dioxin concentration in the site with pollutant sources and the lack of the pollutant diffusion was relatively high as compared with the other sites. As a result of contribution ratio of dioxin congeners, OCDD (Octachlorodibenzodioxin) in all sites was major contributor in real value, in contrast, dioxin congeners in TEQ values were dominated by 2,3,4,7,8-PeCDF.

드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정 (Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone)

  • 김희상;박용희;김우영;은희람;안강호
    • 한국입자에어로졸학회지
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

새로운 HDBPDA와 Dowex 이온교환수지의 이온교환 특성 (Ion Exchange Characteristics of Novel HDBPDA and Dowex Ion Exchange Resins)

  • 김동원;김창석;최기영;전영신;정영규;윤여학;홍춘표
    • 분석과학
    • /
    • 제6권5호
    • /
    • pp.463-469
    • /
    • 1993
  • 새로운 HDBPDA 이온교환수지, {(4, 5) : (13, 14)-Dibenzo-6, 9, 12-trioxa-3, 15, 21, -triazabicyclo [15. 3. 1]heneicosa-(1, 17, 19)(18, 20, 21) triene ion exchange resin : HDBPDA ion exchange resin}의 이온교환용량은 3.8meq/g이었다. 그리고 HDBPDA와 강산성 양이온교환수지인 Dowex 50W-X8(200-400mesh)에 대한 알칼리 및 알칼리 토금속 이온의 분포계수를, 물과 여러 농도의 염산 용액 중에서 측정하였다. HDBPDA 이온교환수지에 대한 금속 이온들의 분포계수는 염산 농도의 영향을 크게 받지 않았으나, 일반적으로 염산의 농도가 감소할수록 점진적으로 약간 증가하는 경향을 보였다. 그리고 물 속에서의 분포계수가 가장 컸다. Dowex 50W-X8에 대한 알칼리 및 알칼리 토금속 이온들의 분포계수는 염산 농도의 감소에 따라 증가하였으며, 특히 알칼리 토금속 이온들의 분포계수가 알칼리 금속 이온들에 비하여 훨씬 더 급격하게 증가하였다. HDBPDA 이온교환수지에 대한 알칼리 및 알칼리 토금속이온들의 분포계수는, 염산 농도에 대하여 직선적으로 변화하였으며, 그 기울기, d log Kd/d log $M_{HCl}$은 약-0.2였다. 그러나 Dowex 50W-X8에 대한 알칼리 및 알칼리 토금속 이온들의 경우, 보통의 염산 농도하에서 그 기울기는 각각 약 -1 및 -2였다. 그러나 매우 묽은 염산 농도하에서는 분포계수와 염산 농도 사이의 직선 관계는 성립하지 않았으며, 그 기울기는 위의 값으로부터 벗어났다.

  • PDF

볼텍스쉐이커를 이용한 11개 나노물질의 분진날림 비교 (Comparison of Dustiness of Eleven Nanomaterials using Voltex Shaker Method)

  • 이나루;박진우
    • 한국산업보건학회지
    • /
    • 제28권3호
    • /
    • pp.273-282
    • /
    • 2018
  • Objectives: Dustiness of nanomaterials is considered as exposure index of essential material. Research on dustiness of nanomaterial is needed to control exposure in workplaces. Method: Dustiness measurement using vortex shaker were installed in the laboratory. Nanomaterials, 1 g, was put in the glass test tube and shaked using vortex shaker. Aerosol dispersed was measured using scanning mobility particle sizer(SMPS) and optical particle counter(OPC). Mass concentration using PVC filter and cassette was measured and TEM grid sampling was conducted. Total particle concentration and size distribution were calculated. Image and chemical composition of particles in the air were observed using transmission electron microscopy and energy dispersive X-ray spectrometer. Eleven different test nanomaterials were used in the study. Results: Rank of mass concentration and particle number concentration were coincided in most cases. Rank of nanomateirals with low concentration were not coincided. Two types of fumed silica had the highest mass concentration and particle number concentration. Indium tin oxide, a mixture of indium oxide and tin oxide, had high mass concentration and particle number concentration. Indium oxide had very low mass concentration and particle number concentration. Agglomeration of nanoparticles in the air were observed in TEM analysis and size distribution. In this study, mass concentration and particle number concentration were coincided and two index can be used together. The range of dustiness in particle number concentration were too wide to measure in one method. Conclusion: Particle number concentration ranged from low concentration to high concentration depend on type of nanomaterial, and varied by preparation and amount of nanomaterial used. Further study is needed to measure dustiness of all nanomaterial as one reference method.

서울시 PM10 공간분포 분석과 시계열 변화 (A Spatial Distribution Analysis and Time Series Change of PM10 in Seoul City)

  • 정종철
    • 한국지리정보학회지
    • /
    • 제17권1호
    • /
    • pp.61-69
    • /
    • 2014
  • 본 연구에서는 서울에서 직경 $10{\mu}m$이하의 미세먼지에 대한 공간분석을 수행하였다. PM10은 폐암과 질병에 의한 사망율을 증가시키는 주요 원인이기 때문에 PM10의 공간적 분포는 서울의 대기오염에서 중요한 관심 사항이다. 본 연구에서 PM10의 공간적 분포 분석은 2010년과 2011년 서울시 미세먼지의 월 평균자료에 의해 모니터링 되었다. PM10의 공간보간은 PM10의 공간분포 특성을 잘 반영하는 IDW 방법을 적용하였고, PM10의 월 평균 공간분포는 서울시의 서부지역(영등포)이 초봄과 겨울철에 서울시의 북부지역 보다 높은 농도의 공간 분포를 나타내었다. 또한 2010년과 2011년 PM10 농도 분포의 비교에서 2011년 강남구와 송파구의 PM10 농도는 2010년 연평균 공간분포 보다 증가하였다. 서울시 PM10의 공간 분포가 영등포구, 강남구, 청량리 등 특정지역에서 높은 경향을 나타내고 있어서 이에 대한 관리방안의 수립이 요구된다.

서울시 일부 지역의 대기 중 부유 진균의 분포 특성 (Distribution Characteristics of Airborne Fungi in a Partial Area of Seoul City)

  • 김기연;김대근
    • 한국환경보건학회지
    • /
    • 제38권5호
    • /
    • pp.407-414
    • /
    • 2012
  • Objectives: This study was performed to assess based on field investigation the distribution characteristics of airborne fungi in an area of Seongdong-gu, Seoul. Methods: Three sites, a living area, forest and traffic site, were selected for evaluation of monthly level of outdoor airborne fungi. An on-site survey was executed between January 2009 and December 2009. During the experimental period, air sampling was performed every month in the afternoon (2:00 pm-5:00 pm) using a cascade impactor. Results: Outdoor airborne fungi measured in Seoul, Korea over one year showed a concentration range from 850CFU $m^{-3}$ to 15,200CFU $m^{-3}$. The mean respirable fraction of outdoor airborne fungi was 67% compared to total concentration. Regardless of measurement site, there was no significant concentration difference in outdoor airborne fungi between periods of yellow dust and non-yellow dust (p>0.05). There was no significant correlation relationship between outdoor airborne fungi and atmospheric factors such as temperature and relative humidity. The predominant genera of airborne fungi identified were Aspergillus, Cladosporium, Paecilomyces and Penicillium. Conclusion: Monthly levels of outdoor airborne fungi were highest in April and November and lowest in August. In seasonal concentration distribution, the autumn showed the highest level of outdoor airborne fungi, followed by spring, summer and winter. In regional concentration distribution, the highest level of outdoor airborne fungi was generally found in the forest, followed by the living area and traffic site.

Inducibility of human atrial fibrillation in an in silico model reflecting local acetylcholine distribution and concentration

  • Hwang, Minki;Lee, Hyun-Seung;Pak, Hui-Nam;Shim, Eun Bo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제20권1호
    • /
    • pp.111-117
    • /
    • 2016
  • Vagal nerve activity has been known to play a crucial role in the induction and maintenance of atrial fibrillation (AF). However, it is unclear how the distribution and concentration of local acetylcholine (ACh) promotes AF. In this study, we investigated the effect of the spatial distribution and concentration of ACh on fibrillation patterns in an in silico human atrial model. A human atrial action potential model with an ACh-dependent $K^+$ current ($I_{KAch}$) was used to examine the effect of vagal activation. A simulation of cardiac wave dynamics was performed in a realistic 3D model of the atrium. A model of the ganglionated plexus (GP) and nerve was developed based on the "octopus hypothesis". The pattern of cardiac wave dynamics was examined by applying vagal activation to the GP areas or randomly. AF inducibility in the octopus hypothesis-based GP and nerve model was tested. The effect of the ACh concentration level was also examined. In the single cell simulation, an increase in the ACh concentration shortened $APD_{90}$ and increased the maximal slope of the restitution curve. In the 3D simulation, a random distribution of vagal activation promoted wavebreaks while ACh secretion limited to the GP areas did not induce a noticeable change in wave dynamics. The octopus hypothesis-based model of the GP and nerve exhibited AF inducibility at higher ACh concentrations. In conclusion, a 3D in silico model of the GP and parasympathetic nerve based on the octopus model exhibited higher AF inducibility with higher ACh concentrations.

주물사업장의 입자상물질 입경분포 및 비산배출 특성 (Characteristics of Size Distribution and Fugitive Emissions of Particulate Matter in Foundries)

  • 박정호;장민재;김형갑
    • 한국산업보건학회지
    • /
    • 제26권1호
    • /
    • pp.30-37
    • /
    • 2016
  • Objectives: This study was performed to measure and evaluate the concentration, size distribution and fugitive emission of particulate matter from process operations at foundries. Methods: Particle matter was collected from three foundries, and samples were also collected from a background site for calculating the fugitive emission concentration of the foundries. For the collection of the samples, a Nanosampler cascade impactor was used. Results: The concentration of TSP in the samples collected from the three foundries was $0.675{\sim}1.222mg/m^3$, $PM_{10}$ was $0.525{\sim}1.018mg/m^3$ and $PM_{2.5}$ was $0.192{\sim}0.615mg/m^3$. The mass size distribution was bimodal or monomodal with maximum peak at two stage(size $2.5{\sim}10{\mu}m$). The mass median aerodynamic diameter(MMAD) was $1.80{\sim}3.98{\mu}m$. The fugitive emission concentration of TSP varies in the range of 0.65 to $1.21mg/m^3$, which exceeds the emission standard of fugitive dust($0.5mg/m^3$). Conclusions: Particle concentration and size is an important industrial hygiene factor to protect foundry workers. Furthermore, the presence of high emission of particulate pollutants has a significant negative impact on the ambient air of the study area. Therefore, it is important to improve both the process and prevention facility in oder to reduce particulate pollutants in foundries.