• Title/Summary/Keyword: Concentration coefficient

Search Result 2,041, Processing Time 0.024 seconds

나노 세리아 슬러리에 첨가된 연마입자와 첨가제의 농도가 CMP 연마판 온도에 미치는 영향

  • 김성준;강현구;김민석;박재근
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.12a
    • /
    • pp.122-125
    • /
    • 2003
  • We investigated the effect of the abrasive and additive concentrations in Nano ceria slurry on the pad surface temperature under varying pressure through chemical mechanical polishing (CMP) test using blanket wafers. The pad surface temperature after CMP increased with the abrasive concentration and decreased with increase of the additive concentration in slurries for the constant down pressure. A possible mechanism is that the additive adsorbed on the film surface during polishing decreases the friction coefficient, hence the pad surface temperature gets lower with increase of the additive concentration. This difference of temperature was more remarkable for the higher concentration of abrasives. In addition, in-situ measurement of spindle motor was carried out during oxide and nitride polishing. The averaged motor current for oxide film was higher than that for nitride film, which means the higher friction coefficient.

  • PDF

Sludge Returned CMAS에 의한 전기부속품제조공장 폐수처리

  • 김남천;이시진
    • Microbiology and Biotechnology Letters
    • /
    • v.25 no.4
    • /
    • pp.427-433
    • /
    • 1997
  • Sludge Returned CMAS process was applied to treat the wastewater from electric accessory manufacturing company while this type of wastewater was usually treated by chemical process. This result show that the removal rate of TCOD was about 70-80% regardless of hydraulic retention time, On the contrary, the removal rate of BOD was abtained in a range of 77-92% depending on hydraulic retention time. In order to remove more than 80% of organic materials with the proposed process, the F/M ratio should be maintained below 0.17. In this case, the calculated value of organic removal rate, Km, was calculated to be 1.26 hr$^{-1}$, and the ratio of cell synthesis/total energy was 0.32 and 0.26 for COD and BOD base, respectively. The yield coefficient was calculated to be 0.242 and the half velocity coefficient was 0.3 hr$^{-1}$. The value of endogenous respiration coefficient was 0.02 hr$^{-1}$. The measured effluent BOD concentration, MLSS concentration in aeration tank, oxygen uptake rate, and sludge production were matched relatively well with the calculated values using above coefficients, In order to optimize the dewatering of sludge, the hydraulic retention time was recommended to be 15. 6 hrs. These results indicate that the wastewater from an eletric accessory manufacturing company can be treated safely with a biological process.

  • PDF

Correlation between chloride-induced corrosion initiation and time to cover cracking in RC Structures

  • Hosseini, Seyed Abbas;Shabakhty, Naser;Mahini, Seyed Saeed
    • Structural Engineering and Mechanics
    • /
    • v.56 no.2
    • /
    • pp.257-273
    • /
    • 2015
  • Numerical value of correlation between effective parameters in the strength of a structure is as important as its stochastic properties in determining the safety of the structure. In this article investigation is made about the variation of coefficient of correlation between effective parameters in corrosion initiation time of reinforcement and the time of concrete cover cracking in reinforced concrete (RC) structures. Presence of many parameters and also error in measurement of these parameters results in uncertainty in determination of corrosion initiation and the time to crack initiation. In this paper, assuming diffusion process as chloride ingress mechanism in RC structures and considering random properties of effective parameters in this model, correlation between input parameters and predicted time to corrosion is calculated using the Monte Carlo (MC) random sampling. Results show the linear correlation between corrosion initiation time and effective input parameters increases with increasing uncertainty in the input parameters. Diffusion coefficient, concrete cover, surface chloride concentration and threshold chloride concentration have the highest correlation coefficient respectively. Also the uncertainty in the concrete cover has the greatest impact on the coefficient of correlation of corrosion initiation time and the time of crack initiation due to the corrosion phenomenon.

An Esitimation of Lognitudinal Dispersion Coefficient in Natural Stram Using Hydraulic Model (수리모형을 이용한 자연하천에서 종확산계수 추정)

  • Yun, Se-Ui;Han, Geon-Yeon;Han, Jeong-Seok;Kim, Jeong-Su
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.4
    • /
    • pp.407-417
    • /
    • 2000
  • To estimate the longitudinal dispersion coefficient at the downstream of Jungrang-River, the undistorted 1/20 scale hydraulic model was used in this study. Experiments were conducted for dry season discharge, and Rhodamine B was used as a tracer. The relationship curve between concentration and conductivity of Rhodamine B was otained by laboratory test, and the conductivity which was measured in hydraulic model was converted to concentration using this curve. The longitudinal dispersion coefficient was calculated using the relationship between the peak concentration and the time to peak concentration. The results of this study were compared with the calculated values by the empirical equations for the longitudinal dispersion coefficient and with the field data. The results of comparison show that Parker's equation underestimates, and Liu'g equation and Iwasa and Aya's one overestimate, and McQuivey and Keefer's equations, Fischer's one, Magazine's one, and Seo and Cheong's one predict relatively well. The measured data sets were relatively close to the observed ones in natural river. The longitudinal dispersion coefficient at the downstream of Jungrang-River was estimated $10\textrm{m}^2/s$.

  • PDF

Quantification of Gadolinium Concentration Using GRE and UTE Sequences

  • Park, So Hee;Nam, Yoonho;Choi, Hyun Seok;Woo, Seung Tae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.171-176
    • /
    • 2017
  • Purpose: To compare different MR sequences for quantification of gadolinium concentration. Materials and Methods: Gadolinium contrast agents were diluted into 36 different concentrations. They were scanned using gradient echo (GRE) and ultrashort echo time (UTE) and R1, $R2^*$ and phase values were estimated from collected data. For analysis, ROI masks were made for each concentration and then ROI value was measured by mean and standard deviation from the estimated quantitative maps. Correlation analysis was performed and correlation coefficient was calculated. Results: Using GRE sequence, R1 showed a strong linear correlation at concentrations of 10 mM or less, and $R2^*$ showed a strong linear correlation between 10 to 100 mM. The phase of GRE generally exhibited a negative linear relationship for concentrations of 100 mM or less. In the case of UTE, the phase had a strong negative linear relationship at concentrations 100 mM or above. Conclusion: R1, which was calculated by conventional GRE, showed a high performance of quantification for lower concentrations, with a correlation coefficient of 0.966 (10 mM or less). $R2^*$ showed stronger potential for higher concentrations with a correlation coefficient of 0.984 (10 to 100 mM), and UTE phase showed potential for even higher concentrations with a correlation coefficient of 0.992 (100 mM or above).

Predictive Model Selection of Disinfection by-products (DBPs) in D Water Treatment Plant (D 정수장 소독부산물 예측모델 선정)

  • Kim, Sung-Joon;Lee, Hyeong-Won;Hwang, Jeong-Seok;Won, Chan-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.460-467
    • /
    • 2010
  • For D-WTP's sedimentation basin and distribution reservoir, and water tap the predictive models proposed tentatively herein included the models for estimating TTHM concentration in precipitated water, for treated water and for tap water, and the estimated correlation formula between treated water's TTHM concentration and tap water. As for TTHM-concentration predictive model in sedimentation water, the coefficient of determination is 0.866 for best-fitted short-term $DOC{\times}UV_{254}$ based Model (TTHM). As for $HAA_5$-concentration predictive model in sedimentation water, the coefficient of determination is 0.947 for the suitable $UV_{254}$-based model ($HAA_5$). In case of the predictive model in treated water, the coefficient of determination is 0.980 for best-fitted $DOC{\times}UV_{254}$ based model (TTHM) using coagulated waters, while the coefficient of determination is 0.983 for best-fitted $DOC{\times}UV_{254}$ based model ($HAA_5$) using coagulated waters, which described the $HAA_5$ concentration well. However, the predictive model for tap water could not be compatible with the one for treated water, only except for possibility inducing correlation formula for prediction, [i.e., the correlation formula between TTHM concentration and tap water was verified as TTHM (tap water) = $1.162{\times}TTHM$ (treated water), while $HAA_5$ (tap water) = $0.965{\times}HAA_5$ (treated water).] The correlation analysis between DOC and $KMnO_4$ consumption by process resulted in higher relationship with filtrated water, showing that its regression is $DOC=0.669{\times}KMnO_4$ consumption - 0.166 with 0.689 of determination coefficient. By substituting it to the existing DOC-based model ($HAA_5$) for treated water, the consequential model formula was made as follows; $HAA_5=8.35(KMnO_4\;consumption{\times}0.669-0.166)^{0.701}(Cl_2)^{0.577}t^{0.150}0.9216^{(pH-7.5)}1.022^{(Temp-20^{\circ}C)}$

Equilibrium Property of Ion Exchange Resin for Silica Removal at Ultralow Concentration (초저이온농도에서 이온교환수지에 의한 실리카제거 평형특성)

  • Yoon, Tae-Kyung;Lee, Gang-Choon;Noh, Byeong-Il
    • Journal of Environmental Science International
    • /
    • v.16 no.8
    • /
    • pp.907-912
    • /
    • 2007
  • Ion exchange resin was used to remove silica ion at ultralow concentration. The effects of temperature, type of ion exchange resin and single/mixed-resin systems on removal efficiency were estimated. As temperature increased, the slope of concentration profile became stiff, and the equilibrium concentration was higher. In the single resin system, the removal of silica was continued up to 400 min, but the silica concentration was recovered to initial concentration after 400 min due to the effect of dissolved $CO_2$. In the mixed-resin system it took about 600 min to reach equilibrium. Because of faster cation exchange reaction than anion exchange reaction, the effect of $CO_2$ could be removed. Based on the experimental results carried out in the mixed-resin system, the selectivity coefficients of silica ion for each ion exchange resin were calculated at some specific temperatures. The temperature dependency of the selectivity coefficient was expressed by the equation of Kraus-Raridon type.

A Study on Concentration and Centralization of Tonnage in Korean Shipping(A Comparative Study with Egypt)

  • Kim, Hyun-Deok;Ahn, Ki-Myung;Shin, Yong-John
    • Journal of Navigation and Port Research
    • /
    • v.28 no.2
    • /
    • pp.121-127
    • /
    • 2004
  • The shipping industry can be explained by a growing process of concentration and centralization of tonnage. A few largest shipping company control a great deal of shipping tonnage in the total tonnage through the process of concentration and centralization of tonnage in shipping over time. It confirms that a decreasing number of operators take an increasing quantity of tonnage in the total tonnage. Thus, the extremely dualistic structure (extremely unequal distribution of tonnage) are shown not only in the shipping industry in a given country but also in liner shipping in the world In this paper, the two countries, that is, Korea and Egypt, are compared considering the absolute size of tonnage and shipping policy in tenn., of concentration and centralization of tonnage in shipping. In order to measure the degree of concentration of tonnage in shipping, the quantitative measurements; the Lorenz curve and Gini coefficient are introduced. But it should be supplemented with the qualitative measures of tonnage in a given country.

Derivation of Storage Coefficient and Concentration Time for Derivation of Lateral Inflow Hydrograph (측방 유입 수문곡선 유도를 위한 저류상수 및 집중시간의 유도)

  • Yoo, Chul-Sang;Kim, Ha-Young;Park, Chang-Yeol
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.3
    • /
    • pp.243-252
    • /
    • 2012
  • The objective of this study is to analyze lateral inflow hydrologically. The IUH of lateral inflow is sum of the impulse responses of total cells in basin. This IUH bases on the Muskingum channel routing method, which hydrologically re-analysed to represent it as a linear combination of the linear channel model considering only the translation and the linear reservoir model considering only the storage effect. Rectangular and triangular basins were used as imaginary basins and IUH of each basin were derived. The derived IUH have different characteristics with respect to basin's shape. The storage coefficient of lateral inflow was also derived mathematically using general definitions of concentration time and storage coefficient. As a result, the storage coefficient of lateral inflow could be calculated easily using basin's width, length and hydrological characteristics of channel.

Fleece Phenotype Influences Susceptibility to Cortisol-induced Follicle Shutdown in Merino Sheep

  • Ansari-Renani, H.R.;Hynd, P.I.;Aghajanzadeh, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1761-1769
    • /
    • 2007
  • This experiment was conducted to determine the extent to which susceptibility to cortisol-induced follicle shutdown is influenced by fleece phentotype. Twenty Finewool (10 sheep low fibre diameter, low coefficient of fibre diameter-LL and 10 low fibre diameter, high coefficient of variation of fibre diameter-LH) and twenty Strongwool (10 low fibre diameter, low coefficient of variation of fibre diameter-HL and 10 high fibre diameter and high coefficient of variation of fibre diameter-HH) sheep of 9 months of age were individually penned in an animal house and were injected intramuscularly with an aqueous suspension of hydrocortisone acetate at a rate of 1.42 mg/kg body weight for a period of two weeks. Fibre diameter was measured from clipped tattooed patch wool samples. Follicle activity was measured by histological changes in skin biopsies taken weekly. Blood samples were collected at two-week intervals and plasma cortisol measured. Increased plasma cortisol concentration significantly (p<0.05) reduced clean wool production and mean fibre diameter dropped to its lowest level four weeks after commencement and two weeks after the cessation of cortisol injection. Elevation of plasma cortisol concentration significantly (p<0.0001) increased the percentage of inactive follicles two weeks after injection started. High fibre diameter groups (Strongwool sheep; i.e. HL+HH) had significantly (p<0.0001) higher percentage of follicle shutdown than low fibre diameter groups (Finewool sheep; i.e. LL+LH). Average percentage of shutdown follicles for Finewool (LL+LH) and Strongwool (HL+HH) Merino sheep was $9.8{\pm}0.9$ and $13.5{\pm}0.9$ respectively. Shutdown of primary follicles was more pronounced in Finewool than Strongwool sheep. There was no significant effect of coefficient of variation of fibre diameter on propensity to follicle shutdown induced by exogenous cortisol. It is concluded that elevation in plasma cortisol concentration is inhibitory to the normal activity of follicles in Strongwool sheep but that variation in fibre diameter has little or no effect.