• 제목/요약/키워드: Concentration Efficiency

검색결과 4,540건 처리시간 0.036초

다단오존접촉조에서 유해화학물질의 제거특성 (Removal Characteristics of Hazard Organic Substances in the Multi-stage Ozone Contactor)

  • 박영규
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.41-49
    • /
    • 1999
  • The water treatment by was performed to remove VOC and organic substances in the multi-stage ozone contactor. Ozone is mainly utilized to change the chemical structures of organic substance, of which finally has the purpose to degrad them. The removal efficiency of VOC has 20~60% at the ozone concentration of 3 ppm, in case of trichloroethylene, its efficiency is reduced by 85% at the ozone contact time of 8 min. Design factors such as the number of stage, ozone concentration, zone contact time are determined for optimal treatment in the multi-stage contactor.

  • PDF

연속식 PCR과 BCR에서 페놀 농도 증가에 따른 오존 처리 특성에 관한 연구 (A Study on the Ozonation Characteristics of the Phenol Contaminated Wastewater by Increasing Phenol Concentration in the Continuous PCR and BCR)

  • 김용대;안재동;이준
    • 한국환경보건학회지
    • /
    • 제21권2호
    • /
    • pp.12-19
    • /
    • 1995
  • The objectives of this research prograln were to study the ozonation characteristics of phenol contaminated wastewater in the continuous packed column reactor (PCR) and the bubble column reactor (BCR) using ozone that has a strong oxidizing potential, and to provide the fundamentals of ozonizing the phenol contaminated wastewater. Among various influencing factors on phenol decomposition through the oxidation by ozone, phenol/ozone mde ratio was chosen as reaction parameters. Concerning the phenol/ozone mde ratio, as the influent phenol concentration increased from 30 mg/l to 150 mg/l, the phenol removal efficiency decreased from 99% for 30 mg/l to 83.7% for 150 mg/l, in PCR. PCR also showed higher treatment efficiency than BCR by 1% for 30 mg/l and 2.2% for 150 mg/l, respectively. The ozone utilization efficiency of PCR for the phenol concentration 30 mg/l was higher than that of BCR while the efficiency of both reactors was 99.9% for the phenol concentration of 150 mg/l.

  • PDF

Estimation of the Efficiency of Transgenic Rabbit Production Following GFP Gene Microinjection into Rabbit Zygotes

  • Jin, D.I.;Im, K.S.;Kim, D.K.;Choi, W.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권10호
    • /
    • pp.1367-1372
    • /
    • 2000
  • The present study was conducted to evaluate the efficiency of transgenic rabbit production by DNA microinjection using EGFP (Enhanced Green Fluorescent Protein) gene. In this experiment EGFP coding sequences fused to CMV promoter were microinjected into rabbit one-cell embryos, and then GFP expression and gene integration were evaluated in preimplantation embryos and fetuses recovered on day 15 of pregnancy to determine efficiency of transgenic rabbit production. Effect of DNA concentration was also tested on development in vitro following microinjection and transgene integration in fetuses. Development of embryos in vitro was decreased by DNA microinjection, but the rates of pregnancy and implantation were not significantly affected by microinjection. As development progressed in vitro percentage of GFP expression in rabbit embryos was decreased, resulting GFP expression detected in 37.5% of blastocysts. The efficiencies for production of transgenic fetuses were 4.0% and 7.6%, respectively, when $10ng/{\mu}l$ and $20ng/{\mu}l$ of DNA concentration were microinjected. Transgenic fetuses were confirmed by GFP expression and PCR analysis of fetus genomic DNA. These results indicated that DNA microinjection itself damaged embryo development and DNA concentration affected the efficiency of transgenic rabbit production.

버퍼층으로 사용한 PVK의 농도 변화에 따른 유기 발광 소자의 전압-전류-휘도 특성 (Current-Voltage-Luminance Characteristics of Organic Light-Emitting Diodes with a Variation of PVK Concentration Used as a Buffer Layer)

  • 김상걸;홍진웅;김태완
    • 한국응용과학기술학회지
    • /
    • 제19권1호
    • /
    • pp.68-72
    • /
    • 2002
  • We have seen the effects of buffer layer in organic light-emitting diodes(OLEDs) using poly(N-vinylcarbazole)(PVK) depending on a concentration of PVK. Polymer PVK buffer layer was made using spin casting technique. Two device structures were fabricated; one is ITO/TPD/$Alq_{3}$/Al as a reference, and the other is ITO/PVK/TPD/$Alq_{3}$/Al to see the effects of buffer layer in organic light-emitting diodes. Current-voltage-luminance characteristics and an external quantum efficiency were measured with a variation of spin-casting rpm speeds and PVK concentration. We have obtained an improvement of external quantum efficiency by a factor of four when the PVK concentration is 0.1wt% is used. The improvement of efficiency is expected due to a function of hole-blocking of PVK in OLEDs.

$TiO_2$ 광촉매반응을 이용한 수중의 은이온 제거에 관한 연구 (A Study on the Removal of Ag(I) in Water Using $TiO_2$ Photocatalysis)

  • 김현용;조일형;양원호;김민호;이홍근
    • 환경위생공학
    • /
    • 제15권2호
    • /
    • pp.58-64
    • /
    • 2000
  • The photocatalytic removal of Ag(I) in water by $TiO_2$ at a various conditions, which are initial Ag(I) concentration, circulation flow rate, $TiO_2$ dosage and methanol concentration, was studied. A continuous flow system with a circular type reactor of the TiO2 suspensions with UV light through an photoreactor column was applied. The major results of this study were as follows; 1. First order kinetics was observed from the result at different initial concentration of Ag(I). As the initial Ag(I) concentration was incereased, the reaction rate was decreased. 2. The removal efficiency of Ag(I) increased with increasing the circulation flow rate and $TiO_2$ dosage. However, over $4{\ell}/min$ of circulation flow rate and $1.5g/{\ell}$ of $TiO_2$ dosage, increasing of the efficiency reached a plateau. 3. The addition of methanol as hole scavenger enhanced the removal efficiency of Ag(I) but the removal efficiency reached a plateau over some level of methanol. 4. It was found that $TiO_2$ photocatalysis was effective method to remove of Ag(I) from aqueous solution.

  • PDF

Parametric study for enhanced performance of Cu and Ni electrowinning

  • Kim, Joohyun;Kim, Han S.;Bae, Sungjun
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.201-206
    • /
    • 2019
  • In this study, we performed an electrowinning process for effective removal of metals (Cu and Ni) in solution and their recovery as solid forms. A complete removal of Cu and Ni (1,000 mg/L) was observed during four times recycling test, indicating that our electrowinning system can ensure the efficient metal removal with high stability and durability. In addition, we investigated effect of operation parameters (i.e., concentration of boric acid only for Ni, variation of pH, concentration of electrolyte ($H_2SO_4$), and cell voltage) on the efficiency of metal removal (Cu and Ni) during the electrowinning. The addition of boric acid significantly enhanced removal efficiency of Ni as the concentration of boric acid increased up to 10 g/L. Compared to negligible pH effect (pH 1, 2, and 4) on the Cu removal, we observed the increase in removal efficiency of Ni as the pH increased from 1 to 4. The electrolyte concentration did not significantly influence the removal of Cu and Ni in this study. We also obtained great removal rates of Cu and Ni at 2.5 V and 4.0 V, which were much faster than those at lower voltages. Finally, almost 99% of each Cu and Ni (1,000 mg/L) was selectively removed from the mixture of metals by adjusting pH and addition of boric acid after the completion of Cu removal. The findings in this study can provide a fundamental knowledge about effect of important parameters on the efficiency of metal recovery during the electrowinning.

호기조에 고정상 담체를 충진한 A2/O공정에서 무산소조 체류시간 변화가 유기물질 및 질소 제거에 미치는 영향 (A Study on the Effect of an HRT of Anoxic Reactors on Organic Matter and Nitrogen Removal in A2/O Processes with Bio Contact Media in Aerobic Tank)

  • 황규대;한봉석
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.451-457
    • /
    • 2007
  • Four parallel $A^2/O$ systems maintaining an MLSS of 3,000 mg/L were operated to investigate the effects of varying an HRT of anoxic reactors and packing Bio contact media (BCM, fixed beds) in aerobic reactors on organic matter removal and nitrification/denitrification efficiencies. All systems were operated under conditions that the external recycle ratio was kept 0.5 Q while the internal recycle ratio was changed 1.0 Q to 1.5 Q with that $NH_4-N$ concentration of feed was increased to 40 mg/L by adding $NH_4Cl$. In terms of TSS and TCODcr removal efficiency, both systems with BCM and a system without BCM, respectively, had a similar level of the removal efficiency under varied HRTs of anoxic reactors (0.6 hr, 1.3 hr, 2 hr, 2 hr; control, without BC M) showing that varying an HRT of anoxic reactors did not affect the removal efficiency. While SCODcr removal efficiency of systems with BCM was improved approximately 4~5% at the same HRT of anoxic reactor, the removal efficiency of system with BCM was slightly decreased by reducing an HRT of anoxic reactor. The nitrification efficiency for both systems with BCM and a system without BCM was above 94% showing that packing BCM in aerobic reactors and varying an HRT of anoxic reactors did not affect the efficiency significantly despite of increasing $NH_4-N$ concentration of feed. The denitrification efficiency increased from 81.4% to 85.4% at system with BCM while the efficiency decreased when a shorter HRT of anoxic reactors was kept. The excellent effluent quality for $NO_3-N$ concentration was observed although the $NO_3-N$ concentration increased in anoxic reactors that $NH_4-N$ concentration of feed sufficiently converted into nitrate through nitrification. As a result, packing 20% BCM to an aerobic reactor with HRT of 1.3 hr of anoxic reactor in $A^2/O$ system can achieve a similar level of nitrogen removal efficiency in $A^2/O$ system which the aerobic reactor had no BCM and HRT of 2 hr for anoxic reactor is maintained.

Removal of nitrate by electrodialysis: effect of operation parameters

  • Park, Ki Young;Cha, Ho Young;Chantrasakdakul, Phrompol;Lee, Kwanyong;Kweon, Ji Hyang;Bae, Sungjun
    • Membrane and Water Treatment
    • /
    • 제8권2호
    • /
    • pp.201-210
    • /
    • 2017
  • We investigated the effect of applied voltage and electrolyte concentration on the nitrate removal and its energy/current efficiency during the electrodialysis. The current increased as the applied voltage increased up to 30 V showing the limiting current density around 20 V. The nitrate removal efficiency (31 to 71% in 240 min) and energy consumption (11 to $77W{\cdot}h/L$) gradually increased as the applied voltage increased from 10 to 30 V. The highest current efficiency was obtained at 20 V. The increase in electrolyte concentration from 100 to 500 mM led to the dramatic increase of nitrate removal efficiency with much faster removal kinetics (100 % in 10 min).

보건용 마스크의 분진포집효율, 흡기저항 및 CO2 농도 (Dust Collection Efficiency, Inhalation Pressure, and CO2 Concentration in Health Masks)

  • 한돈희;김일순
    • 한국환경보건학회지
    • /
    • 제46권1호
    • /
    • pp.78-87
    • /
    • 2020
  • Objectives: To identify the degree of physical burden, a determination was undertaken of dust collection efficiency, inhalation pressure, and CO2 concentration related to health masks certified by the Ministry of Food and Drug Safety (MFDS). Methods: Twenty health masks were purchased on the market. Dust collection efficiency and inhalation pressure were determined in the same manner as in MFDS certification testing, respectively using TSI Model 8130 (TSI, U.S.) and ART Plus (Korea). CO2 concentrations for 20 subjects using a CO2 analyzer (G100, G150, Geotechnical Instrument Ltd., UK) were measured with a similar method as a total inward leakage test. In addition to CO2 levels, dead space volumes in the masks was determined for predicting concentrations of CO2 in inhalation air. Results: Most of the dust collection efficiencies found for the 20 masks were far higher than the standard. Four KF94s met KF99 and four KF80s even met KF94. Most inhalation pressures were also much lower than the standard, with many almost one-half of the standard. The mean and standard deviation of CO2 concentration in the mask were 2.9±0.44%. Considering dead volume, the prediction for CO2 concentration in the inhalation air was 4,395±1,266 ppm. Conclusions: For healthy men and women, the dust collection efficiency and inhalation pressure of health masks were not at a level that would affect their health. Although CO2 levels in the inhalation air were predicted not to affect health, research on the physiological effects of health masks on Koreans is needed for more precise research.

미생물 고정화를 이용한 산성염료의 처리 (Treatment of Acid dye Using Microbial Immobilization)

  • 김정목;조무환;양용운
    • 한국염색가공학회지
    • /
    • 제11권2호
    • /
    • pp.19-26
    • /
    • 1999
  • Strains degrading and decolorizing acid dyes, Nylosan red E-BL 150%. were isolated from natural system, was named as ARK3. The optimal culture conditions of temperature and pH were $35^\circ{C}$, 7.0, respectively. Growth rate of cells in conditions of aerobic shaking more than standing culture conspicuously increased, and optical density of those to strain ARK3 were found as 1.38 and 0.25 after 42 hrs. Decolorization efficiency in batch culture which used as immobilization media to natural zeolite was 15% after 6 hrs, while suspension culture was 5%, also its of immobilization and suspension culture were 90% and 85% after 48 hrs, respectively. Decolorization efficiency of air-lift bioreactor was more than 90% to a dilution rate of $0.038hr^{-1}$, but that was decreased as 70%, when the dilution rate was $0.05hr^{-1}$. Even though at maximum dilution rate of this study, there was not appeared "wash out" phenomienon of biomass. Decolorization efficiency was 97.7% at a dilution rate of $0.025hr^{-1}$, when influent dye concentration was $100mg/\ell$. But if influent dye concentration increased as $150mg/\ell$, even though MLVSS increased, that of treatment water decreased as 93%. Also, when influent dye concentration increased as $200mg/\ell$ and $300mg/\ell$, decolorization efficiencies of treatment water abruptly decreased as 85% and 63%, respectively. Decolorization efficiency was more than 92% to the limit volumetric loading rate of $3.75mg/\ell\cdot{hr}$hr, without regard to variation of influent dye concentration or hydraulic retention time. if volumetric loading rate was more than $3.80mg/\ell\cdot{hr}$, at same condition, decolorization efficiency was lower decrease of retention time than increase of influent dye concentration.entration.

  • PDF