• Title/Summary/Keyword: Concentration Distribution

Search Result 4,122, Processing Time 0.035 seconds

Developing a Method for Detecting the Asian dust event Among High $PM_{10}$ events Using Aerodynamic Particle Sizer (APS) (Aerodynamic Particle Sizer (APS)를 이용한 고농도 $PM_{10}$ 사례 중 황사 판별기법 개발)

  • Lee, Young-Gon;Cho, Chun-Ho;Kim, Myoung-Soo
    • Atmosphere
    • /
    • v.18 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • Log normalized volume size distribution (dV/dlog$D_p$) with 52 size ranges from 0.5 to $20.0{\mu}m$ was measured for the cases of high $PM_{10}$ mass concentration (> $200{\mu}gm^{-3}$) using the Aerodynamic Particle Sizer (APS) at the Korea Global Atmosphere Watch Center (KGAWC) from 6 April, 2006 to 5 April, 2007. Black Carbon (BC), gaseous pollutants of $NO_X$ and $SO_2$ and ${\AA}ngstr\ddot{o}m$ exponent were also measured to examine the properties of the volume size distribution. From distinct difference of the high volume concentration (> $100{\mu}m^3cm^{-3}$), the volume size distribution for each event day was clasified into four types: (1) Type 1 had the high volume concentration for supermicron particles from 2.3 to $6.0{\mu}m$ and maximum average volume concentration was $160.7{\mu}m^3cm^{-3}$ at $3.5{\mu}m$. (2) Type 2 represented the high volume concentration in the both size range of submicron ($0.7-1.0{\mu}m$) and supermicron particles ($2.1-4.1{\mu}m^3cm^{-3}$ and $136.2{\mu}m^3cm^{-3}$ were found at 0.8 and $3.3{\mu}m$ respectively. (3) Type 3 showed the high volume concentration in the size range of $0.5-3.5{\mu}m$ and highest volume concentration of $201.1{\mu}m^3cm^{-3}$ at the particle size bin of $0.8{\mu}m$. (4) Type 4 was characterized by the high volume concentration for the fine particles less than $1.2{\mu}m$ and very high concentration of $446.8{\mu}m^3cm^{-3}$. ${\AA}ngstr\ddot{o}m$ exponent, concentration of gaseous ($NO_X$ and $SO_2$), and particle (BC) pollutants suggested that Type 1 was a typical volume size distribution for the Asian dust and Type 3 provided transportation of air pollutants. The distribution in Type 2 found to have both characteristics of the Asian dust and air pollutants, and Type 4 was took place during the foggy atmosphere containing high density of local pollutants. Based on the properties of volume size distribution, we can identify the three major events contributing the increase of $PM_{10}$ mass concentration, and hope to provide a guideline for discriminating the Asian dust from high $PM_{10}$ events. More case studies and longeto advance this determination method.

Influence of the Distribution of Wind Velocity and Mist Concentration for the Improvement of Efficiency with an Electrostatic Precipitator (전기집진장치의 효율 개선을 위한 풍속 분포 및 입자농도 분포의 영향)

  • 임헌찬;이덕출
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.155-161
    • /
    • 1998
  • Recently, there are widely needs of small scale electrostatic precipitator(ESP) in machine shop and other factories. Since the space of such factories is limited, the improvement of collection efficiency is predominant subject. In this study, we examine the influence of distribution of wind velocity and oil mist concentration inside the ESP in order to improve the performance of the ESP. The distribution of wind velocity and mist concentration is measured respectively in a cross-sectional plane of the ESP. The former is controlled by using a louver which is placed in front of an ionizer and the latter is controlled by lengthening the pipe of entrance of the ESP in order to have plenty of time that mist is dispersed evenly. It is shown that the uniformity of distribution of wind velocity and mist concentration inside the ESP can be getting by adopting a louver with proper shape and lengthening the pipe of entrance and is also contributed to collection efficiency considerably.

  • PDF

Distribution of the Concentration of Fuel Vapor in DI Gasoline Sprays Under Evaporation Condition (증발 조건에서 직분식 가솔린 분무의 증기 농도의 분포)

  • Hwang, S.C.;Choi, D.S.;Cha, K.J.;Kim, D.J.
    • Journal of ILASS-Korea
    • /
    • v.4 no.4
    • /
    • pp.1-8
    • /
    • 1999
  • The concentration and spatial distribution of vapor phases in DI (Direct Injection) gasoline spray were measured quantitatively by exciplex fluorescence method. Fluorobenzene and DEMA (diethylmethylamine) in a solution of hexane were used as the exciplex-forming dopants. The fluorescence intensity of vapor phase were obtained by ICCD camera with the appropriate filter The relationship between fluorescence intensity and vapor concentration was induced fer the purpose of a quantitative analysis. The 2-D vapor/liquid images of fuel spray were captured under the evaporation condition, and the spatial distribution of vapor concentration was obtained. The spatial distribution of liquid phase had hollow-cone shape. And the vapor phase was widely distributed in the whole spray. The behavior of vapor phase was significantly affected by second flow such as entrainment, vortex, while that of liquid phase was scarcely affected.

  • PDF

The Analysis of Spatial Distribution of Ozone in the Southern Coast of Korea using the Aircraft (2009, Summer) (항공기를 이용한 남해안 지역의 오존 공간분포 조사 (2009년, 여름철))

  • Seo, Seok-Jun;Kim, So-Young;Lee, Min-Do;Choi, Jin-Soo;Kim, Su-Yeon;Lee, Seok-Jo;Kim, Jeong-Soo;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.12-21
    • /
    • 2012
  • The purpose of this study is to understand distribution of ozone concentration in the south coastal region of Korea by evaluating ozone spatial distribution in the upper air using aircraft. Sampling was carried out from May to August in 2009. The average concentration of ozone in the upper air was ranged from 32.3~90.8 ppb with its maximum concentration of 132 ppb. When it comes to the spatial distribution of ozone, ambient concentration was high in the air, 1,000 m and 500 m above the southern sea near the Gwangyang Bay area and emission sources, respectively. Daily mean concentration of NOy was 6.7~24.2 ppb and that of CO was 0.152~0.487 ppm. In addition, the concentration was appeared to be relatively high in the upper air of industrial regions and the southern seas. Meanwhile, the concentration of both $NO_y$ and CO was high in the upper air of the emission sources regardless of latitude. As for PAN, its daily mean concentration ranged between 0.1 and 0.6 ppb with overall mean concentration of 0.2 ppb. The average concentration of VOCs was 48 ppb, and the concentration of toluene and m,p-Xylene were higher than other components.

A Study on the Structure of Axial-Symmetric Two-Phase Spray and Flame (축대칭 이류체 분무화염의 구조에 관한 연구)

  • Jung, Bo-Yoon;Ko, Dae-Kwon;Ahn, Soo-Kil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.36-43
    • /
    • 1988
  • Boilers and diesel engines have many problems because their exhaust particles, i.e., soot have lots of bad influence on environment. And it's spray and flame have fundamentally axial symmetric shape. To investigate the relationship between fuel concentration distribution of spray and soot concentration distribution as well as temperature distribution of flame, we made a axial symmetric two phase spray-flame and analyzed the structure of is. The measuring method is the principle of the light extinction method for the spray-flame and onion peeling model is applied to analyze the radial distribution of fuel and soot concentration. The temperature of flame is measured by ø 0.4mm Pt-Pt.RH 3% thermocouple. The oils for the experiments are diesel oil and 10% water emulsified diesel oil. It was found that the soot concentration becomes higher as it comes near to the center of flame, and the fuel concentration does, too. And the soot concentration level of diesel oil is generally higher than that of the 10% water emulsified fuel. The maximum flame temperature of diesel oil is 1,17$0^{\circ}C$, however, 10% water emulsified diesel oil is 1,27$0^{\circ}C$.

  • PDF

Characteristics of Urban Aerosol Number Size Distribution in Seoul during the Winter Season of 2001 (2001년 겨울철 서울 대기 에어로졸의 입경별 수 농도 특성)

  • 배귀남;김민철;임득용;문길주;백남준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.2
    • /
    • pp.167-177
    • /
    • 2003
  • The number size distribution of urban aerosols ranging from 0.02 to 20 ${\mu}{\textrm}{m}$ in diameter was measured by using a scanning mobility particle sizer (SMPS) system and an aerodynamic particle sizer spectrometer (APS) at Seoul from November 30,2001 to January 14, 2002. The gaseous species such as CO, NO, NO$_2$, and $O_3$ were also continuously monitored. The daily average concentration of urban aerosols sorted into three groups (0.02~0.1 ${\mu}{\textrm}{m}$, 0.1~1 ${\mu}{\textrm}{m}$ and 1~10 ${\mu}{\textrm}{m}$) and the typical number, surface, and volume distributions of urban aerosols were discussed in this paper. The weekly variation of aerosol concentration was compared with those of gaseous concentrations. relative humidity, and visibility. The results showed that the particle number concentration seemed to increase in the morning and the number concentration of fine particles less than 1 fm in diameter seemed to increase when the concentrations of CO, NO, and NO$_2$ were high. The number concentration of fine particles was relatively high when the relative humidity was greater than 70% during the increasing period of relative humidity. The visibility was weakly correlated with the concentration of aerosols ranging 0.1 to 1 ${\mu}{\textrm}{m}$, and the number size distribution for high visibility episode was apparently different from that for low visibility episode.

Simulation for Chlorine Residuals and Effect of Rechlorination in Drinking Water Distribution Systems of Suwon City (수원시 상수관망에서 잔류염소와 재염소주입의 효과 예측)

  • Kim, Kyung-Rok;Lee, Byong-Hi;Yoo, Ho Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.108-116
    • /
    • 2000
  • Chlorine is widely used as a disinfectant in drinking-water systems throughout the world. Chlorine residual was used as an indicator for prediction of water quality in water distribution systems. The variation of chlorine residual in drinking water distribution systems of Suwon city was simulated using EPANET. EPANET is a computerized simulation model which predicts the dynamic hydraulic and water quality behavior within a water distribution system operating over an extended time period. Sampling and analysis were performed to calibrated the computer model in 1999 (Aug. Summer). Water quality variables used in simulations are temperature, roughness coefficient, pipe diameter, pipe length, water demand, velocity and so on. Extended water residence time affected water quality due to the extended reaction time in some areas. All area showed the higher concentration of chlorine residual than 0.2mg/l(standard). So it can be concluded that any area in Suwon city is not in biological regrowth problem. Rechlorination turned out to be an useful method for uniform concentration of free chlorine residual in distribution system. The cost of disinfectant could be saved remarkably by cutting down the initial chlorine concentration to the level which guarantees minimum concentration (0.2mg/l) throughout the distribution system.

  • PDF

Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System (Pilot 규모의 모의 관망에서의 염소 농도 예측)

  • Kim, Hyun Jun;Kim, Sang Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

Numerical Simulation of $NO_2$Concentration considering SST Effects (SST 효과를 고려한 계절별 $NO_2$농도 수치모의)

  • 원경미;이화운;김유근
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.187-194
    • /
    • 2001
  • For the purpose of predicting air pollutants concentration in Pusan coastal urban, we used an Eulerian model of flow and dispersion/chemistry/deposition process considering SST effects which estimate through POM. The results of air quality model including emission from various sources show that the seasonal variation pattern of respective pollutants was affected by the seasonal SST fields and local circulation. Horizontal deviation of diurnal SST was 2.5~4K, especially large gradients in coastal region. Through numerical simulation of wind fields we predicted that local circulation prevailed during daytime in summer and nighttime in winter. So high concentration distribution showed toward inland in spring and summer seasons, while high concentration distribution showed at inland near coast in autumn and winter.

  • PDF

Comparison of particle size distribution and particle number concentration measured by APS 3321 and Dust Monitor 1.108 (APS 3321과 Dust Monitor 1.108을 이용한 입자 크기분포 및 수농도 측정결과 비교)

  • Lim, Kyoung-Soo;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.63-70
    • /
    • 2009
  • The size distribution and number concentration of atmospheric aerosol were measured and compared using APS 3321 and Dust Monitor 1.108. The particle size distribution and number concentration measured by two devices were also compared at a particle generation system of standard PSL and fly ash. The number concentration of atmospheric aerosol measured by APS was higher than that by Dust Monitor in particle size range of less than $3.0{\mu}m$, but there was good accordance between them in particle size range of over $3.0{\mu}m$. In the particle generation system of PSL and fly ash, different measurement results were shown because the particle concentration was higher than that of atmospheric aerosol. The number concentration measured by Dust Monitor was higher than that by APS in most particle size ranges. However, the peak concentration of PSL particles measured by Dust Monitor was lower than that by APS. The difference of the collection efficiency in a scrubber by APS and Dust Monitor measurement was less than 10%, but in the particle size of $1.5{\mu}m$, it was over 20%.