• Title/Summary/Keyword: Concealed type

Search Result 25, Processing Time 0.026 seconds

Arthroscopic Findings of Biceps pulley in Shoulder Pathology (견관절 병변과 관련된 이두박건 활차의 관절경적 소견)

  • Choi Chang-Hyuk;Kim Shin-Kun;Jang Woo-Chang;Lee Sung-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.136-141
    • /
    • 2002
  • Purpose : The role of biceps pulley is stabilizing sling for the long head of the biceps tendon against anterior shearing stress in the rotator interval. The purpose of this study was to classify arthroscopic findings of biceps pulley and to evaluate the relationship with shoulder pathology. Materials and Methods : From January 2002 through July 2002, we observed biceps pulley in 49 cases of shoulder pathology treated with arthroscopically. There were 22 cases of anterior instability, 12 cases of rotator cuff tear, 5 of impingement syndrome, 6 of frozen shoulder, 2 of superior labral injury and 1 of each scapulothoracic bursitis and biceps dislocation. We classified biceps pulley as four types according to the arthroscopic appearance. Type I its stretched type. type II as sling type, type III at detached sling type, and type IV as concealed type. Results : We observed stretched type in 24 cases $(49\%)$, sling type in 5 cases $(10\%)$, detached sling type in 2 cases, concealed type in 1 case, and unidentified cases in 17 cases $(35\%)$. Conclusion : Development and variation of biceps pulley may have symptomatic correlation according to the degree of shoulder motion or pathologic status.

  • PDF

A Preliminary Study of the Validity of the Concealed Information Test Using P300 and Reaction Time (P300과 반응시간을 이용한 거짓반응의 타당성에 대한 예비적 연구)

  • Park, Gun-Tae;Rhee, Moon-Sung;Kim, Moo-Jin;Roh, In-Soo;Jeong, Phil-Ja
    • Anxiety and mood
    • /
    • v.4 no.2
    • /
    • pp.99-103
    • /
    • 2008
  • Objectives : The authors sought to examine the differences in the number of P300 detected by subjects in experimental and control groups when exposed to relevant stimuli. In addition, the authors tried to determinethe subjects' reaction time when asked to respond to relevant stimuli. Methods : The subjects were 20 informed female volunteers aged 22-38 years (median age : 24). Relevant stimuli (concealed information) were created by unknowingly exposing the two groups to obscene pictures and semantic questions. The number of P300 detected and the length of reaction time were compared between the two groups. Results : Contrary to theauthors' expectations, there were no significant differences in the number of P300 detected or in the length of reaction time between the two groups. Conclusions : These results indicate that, unlike a polygraph test, concealed information tests adopting P300 and reaction time as major physiological responses ofsubjects exposed to meaningful personal information might not serve as a valid practical tool in the field of criminal psychology. However, further studies involving a greater number of subjects are needed before a final conclusion regarding the validity of this new type of concealed information test can be drawn.

  • PDF

Real-time passive millimeter wave image segmentation for concealed object detection (은닉 물체 검출을 위한 실시간 수동형 밀리미터파 영상 분할)

  • Lee, Dong-Su;Yeom, Seok-Won;Lee, Mun-Kyo;Jung, Sang-Won;Chang, Yu-Shin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.2C
    • /
    • pp.181-187
    • /
    • 2012
  • Millimeter wave (MMW) readily penetrates fabrics, thus it can be used to detect objects concealed under clothing. A passive MMW imaging system can operate as a stand-off type sensor that scans people in both indoors and outdoors. However, because of the diffraction limit and low signal level, the imaging system often suffers from low image quality. Therefore, suitable statistical analysis and computational processing would be required for automatic analysis of the images. In this paper, a real-time concealed object detection is addressed by means of the multi-level segmentation. The histogram of the image is modeled with a Gaussian mixture distribution, and hidden object areas are segmented by a multi-level scheme involving $k$-means, the expectation-maximization algorithm, and a decision rule. The complete algorithm has been implemented in C++ environments on a standard computer for a real-time process. Experimental and simulation results confirm that the implemented system can achieve the real-time detection of concealed objects.

P300-based concealed information test and countermeasures (P300 숨긴정보검사와 대응수단)

  • Eom, Jin-Sup;Eum, Young-Ji;Jang, Un-Jung;Cheong, E-Nae;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.18 no.1
    • /
    • pp.39-48
    • /
    • 2015
  • It is known that P300-based concealed information test (P300 CIT) was not greatly affected by the traditional countermeasures. This study was to test whether P300 CIT is affected by the new countermeasures. We used three types of countermeasures. First type was a sequential countermeasure in which participants had to respond in alternating ways to irrelevants by pressing the left index finger covertly when the encountered irrelevant firstly, by wiggling the right big toe inside the shoe when encountered irrelevant secondly, by imaging his or her mother's name when encountered irrelevant thirdly, and by imaging his or her father's name when encountered irrelevant fourthly until all stimuli were presented. Second type was a partial matching and physical countermeasure. Participants in this type were asked to press the left index finger imperceptibly after one of the irrelevants and wiggle the right big toe after another of the irrelevants. Third type was a partial matching and mental countermeasure. Participants were required to imagine mother's name for one irrelevant and father's name for another irrelevant. The results showed that contrary to our expectation, the use of sequential countermeasure increased the detection rate from 77% to 92%. The partial matching countermeasure had a negative effect on P300 CIT. The physical countermeasure decreased the detection rate from 77% to 46%, and the mental countermeasure decreased the detection rate from 100% to 69%. The necessity for the development of methods to prevent or detect countermeasure is discussed.

Is the t-test insensitive than the bootstrap method in the P300-based concealed information test? (P300 숨긴정보검사에서 t 검증이 부트스트랩 방법보다 덜 민감한가?)

  • Eom, Jin-sup;Sohn, Jin-Hun;Park, Mi-Sook
    • Korean Journal of Forensic Psychology
    • /
    • v.11 no.1
    • /
    • pp.21-36
    • /
    • 2020
  • In P300-based concealed information test (P300 CIT), it evaluates whether the P300 amplitude for the probe is significantly greater than that of the irrelevant to determine if the suspect is telling a lie. An independent sample t-test or a bootstrap method can be used as a statistical test to make that decision. Rosenfeld et al. (2004) used the bootstrap method, claiming that "t tests on single sweeps are too insensitive to use to compare mean probe and irrelevant P300s within individuals" and their method has been accepted to date. The purpose of the study is to evaluate whether the power of t-test is lower than that of the bootstrap method in the P300 CIT. The Monte Carlo study was conducted by using EEG collected from 39 participants. The results showed that the type I error rates of the t-test and the percentile bootstrap method were similar and the power of the percentile bootstrap method was slightly higher than that of the t-test. The type I error rates of the t-test and the percentile bootstrap method were slightly lower than the significance level and the powers of the two tests were also slightly lower than that of the theoretical t-test. On the other hand, the type I error rate and power of the standard error Bootstrap method were the same as those of the theoretical t-test and its power was .012 ~ .081 higher than that of t-test depending on experimental conditions.

  • PDF

A Study on the Development Type of Component Joint Design for Environment Friendly Multi Housing Remodeling (공동주택의 친환경 리모델링을 위한 부품접합부 개선방안의 유형화에 관한 연구 II;욕실 및 주방을 중심으로)

  • Lim, Seok-Ho;Kim, Soo-Am;Hwang, Eun-Kyoung;Yun, Mae-Han
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.370-373
    • /
    • 2006
  • Lastly, the problem of filling occurs in the process of concealed joint of adjacent components and was seen in joints between the structure and an electrical or mechanical device. Therefore, the dry processing which replaces wet joint was seen in joints between the structure and a door, ones between the structure and a finishing materials, ones between a gypsum board and electrical device, and ones between a water pipe and a tile finishing. And a process of separating the area of jointed parts in order to eliminate the problem of overlap was seen in joints between a door and a finishing material and ones between a gypsum board on the ceiling and a light. Lastly, an analysis of a process of exposing concealed parts indicated that the problem of filling could be applied to joints between the structure and an electrical or mechanical device and ones between a finishing material and a mechanical device. This study sought out methods to apply Environment Friendly Multi Housing Remodeling that allow easy remodeling as part of environment- preserving policies. It also contains basic data useful to implement long-life houses in the future by presenting a comprehensive design standard for them

  • PDF

The Effect of Response Type on the Accuracy of P300-based Concealed Information Test (반응양식이 P300 숨긴정보검사의 정확도에 미치는 영향)

  • Jeon, Hajung;Sohn, Jin-Hun;Park, Kwangbai;Eom, Jin-Sup
    • Science of Emotion and Sensibility
    • /
    • v.20 no.3
    • /
    • pp.109-118
    • /
    • 2017
  • This study examined the effects of button response to probe and irrelevant stimuli on P300 amplitude and lie detection rate in P300-based concealed information test. Participants underwent the P300-based concealed information test (P300 CIT) in two conditions. In one button condition participants were instructed to press the left mouse button only when the target was present. In two button condition, they were asked to press the left mouse button for target and right button for non-target. The results showed that the response time to target stimulus was not significantly different between the two conditions, and the response time to the probe stimulus was significantly longer than the irrelevant stimulus. The P300 amplitudes for the probe and irrelevant stimulus were all smaller in one button condition compared to two button condition. However, the P300 amplitude difference between the probe stimulus and the irrelevant stimulus did not show a significant difference in the two experimental conditions, and the lie detection rate did not differ significantly between the two conditions. Based on these findings, the effect of button response on P300 CIT with a short inter-stimulus interval was discussed.

Image Registration and Fusion between Passive Millimeter Wave Images and Visual Images (수동형 멀리미터파 영상과 가시 영상과의 정합 및 융합에 관한 연구)

  • Lee, Hyoung;Lee, Dong-Su;Yeom, Seok-Won;Son, Jung-Young;Guschin, Vladmir P.;Kim, Shin-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6C
    • /
    • pp.349-354
    • /
    • 2011
  • Passive millimeter wave imaging has the capability of detecting concealed objects under clothing. Also, passive millimeter imaging can obtain interpretable images under low visibility conditions like rain, fog, smoke, and dust. However, the image quality is often degraded due to low spatial resolution, low signal level, and low temperature resolution. This paper addresses image registration and fusion between passive millimeter images and visual images. The goal of this study is to combine and visualize two different types of information together: human subject's identity and concealed objects. The image registration process is composed of body boundary detection and an affine transform maximizing cross-correlation coefficients of two edge images. The image fusion process comprises three stages: discrete wavelet transform for image decomposition, a fusion rule for merging the coefficients, and the inverse transform for image synthesis. In the experiments, various types of metallic and non-metallic objects such as a knife, gel or liquid type beauty aids and a phone are detected by passive millimeter wave imaging. The registration and fusion process can visualize the meaningful information from two different types of sensors.

Effects of stimulus similarity on P300 amplitude in P300-based concealed information test (P300-기반 숨긴정보검사에서 자극유사성이 P300의 진폭에 미치는 영향)

  • Eom, Jin-Sup;Han, Yu-Hwa;Sohn, Jin-Hun;Park, Kwang-Bai
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.541-550
    • /
    • 2010
  • The present study examined whether the physical similarity of test stimuli affects P300 amplitude and detection accuracy for the P300-based concealed information test (P300 CIT). As the participant pretended suffering from memory impairment by an accident, own name was used as a concealed information to be probed by the P300 CIT in which the participant discriminated between a target and other (probe, irrelevant) stimuli. One group of participants was tested in the easy task condition with low physical similarity among stimuli, the other group was tested in the difficult task condition with high physical similarity among stimuli. Using the base-to-peak P300 amplitude, the interaction effect of task difficulty and stimulus type was significant at $\alpha$=.1 level (p=.052). In the easy task condition the difference of P300 amplitude between the probe and the irrelevant stimuli was significant, while in the difficult task condition the difference was not significant. Using peak-to-peak P300 amplitude, on the other hand, the interaction effect of task difficulty and stimulus type was not significant with significant differences of P300 amplitude between the probe and the irrelevant stimuli in both task difficulty conditions. The difference of detection accuracy between task conditions was not significant with both measures of P300 amplitude although the difference was much smaller when peak-to-peak P300 amplitude was used. The results suggest that the efficiency of P300 CIT would not decrease even when the perceptual similarity among test stimuli is high.

  • PDF

A Study on the Current Detector with Non Contact Type (비접촉식 전류 검출 장치에 관한 연구)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.5
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.