• 제목/요약/키워드: Computerized system

검색결과 812건 처리시간 0.038초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

리드타임 감소에 의한 효율적 공급체인 구축 - 국내 서버 공급체인을 대상으로 - (Building an Efficient Supply Chain by reduction of lead time with a Focus on Korea Server Manufacturer)

  • 신용석;김태현;문성암
    • 한국유통학회지:유통연구
    • /
    • 제6권2호
    • /
    • pp.1-17
    • /
    • 2002
  • 최근 인터넷 비즈니스의 열풍으로 인하여 국내 인터넷 비즈니스 업체의 수와 사업내용은 여느 선진국가에 못지 않게 높은 성장 및 확장을 보여왔다. 하지만 국내에서 사용되고 있는 인터넷 관련 장비의 대부분은 해외에서 생산된 제품이 주를 이루고 있으며, 실제로 1999년 국내 인터넷 관련 장비 시장에서 국내업체가 차지하는 비중은 불과 27%에 지나지 않았다. 이와 같이 선진 해외 제조업체를 필두로 한 해외 업체의 국내 인터넷 시장 잠식이 본격적으로 진행되고 있는 상황에서, 고객의 요구 충족 및 원가 절감을 통한 경쟁우위의 확보는 국내 제조업체가 생존하기 위한 필수적인 사항이 되고 말았다. 본 연구에서는 지난 몇 년 동안 국내 PC서버 시장의 1위 자리를 놓고 해외 업체와 치열한 경쟁을 벌이고 있는 국내 대표적인 PC서버 제조업체를 대상으로 하여, 이 업체의 공급체인상에 존재하는 비효율, 즉 부품발주주기 간격이 다소 긴 점을 발견하고 이를 수정할 경우 공급체인 전반의 보유 재고량과 총비용 측면에서 나타나는 효과를 시뮬레이션을 통해 분석하였다. 기존에 30일이었던 발주주기를 7일로 단축시켜 시뮬레이션한 결과, 공급체인상의 평균 부품 재고량은 현저히 감소하였으며 판매손실의 감소와 더불어 공급체인 전반에 걸친 총비용의 추정값을 낮추는 결과가 나타났다. 비록 평균 완제품 재고량이 소폭 증가하였고 주문 횟수가 증가함에 따라 총주문비용이 증가하기는 하였지만 발주주기의 단축을 통해 얻어진 평균 부품 재고량의 감소와 판매손실의 감소 이득이 이를 충분히 상쇄하여 최종적으로 총비용 추정값이 감소하는 결과를 보여주었다.

  • PDF

Survival Results and Prognostic Factors in T4 N0-3 Non-small Cell Lung Cancer Patients According to the AJCC 7th Edition Staging System

  • Arslan, Deniz;Bozcuk, Hakan;Gunduz, Seyda;Tural, Deniz;Tattli, Ali Murat;Uysal, Mukremin;Goksu, Sema Sezgin;Bassorgun, Cumhur Ibrahim;Koral, Lokman;Coskun, Hasan Senol;Ozdogan, Mustafa;Savas, Burhan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권6호
    • /
    • pp.2465-2472
    • /
    • 2014
  • Background: The American Joint Committee on Cancer (AJCC) published a new staging system ($7^{th}$ edition) in 2009. In our study, we evaluated the survival results and prognostic factors among T4 local advanced non-small cell lung cancer (LA-NSCLC) patients in a large heterogeneous group, in accordance with this new system. Materials and Methods: We retrospectively evaluated the files of 122 T4 N0-3 M0 LA-NSCLC patients, identified according to the new staging system, treated at two centers between November 2003 and June 2012. Variables correlating with univariate survival at p<0.20 were later included in multivariate Cox regression analysis. Here, selection of relevant predictors of survival was carried out in accordance with the likelihood ratio formula with p<0.05 regarded as significant. Results: The median age was 60 and the median follow-up period was 17.4 months. Median overall survival (OS) was 18.3 months, the 1 year overall survival (OS) rate was 72%, and the 5 year OS rate was 28%. Statistically significant predictors of survival were (p<0.20) ECOG-PS (Eastern Cooperative Oncology Group Performance Status), age, T4 factor subgroup, stage and primary treatment in OS univariate analysis. On multivariate analysis for OS ECOG-PS (p=0.001), diagnostic stage (p=0.021), and primary treatment (p=0.004) were significant. In the group receiving non-curative treatment, the median OS was 11.0 months, while it was 19.0 months in the definitive RT group and 26.6 months in the curative treatment group. There was a significant difference between the non-curative group and the groups which had definitive RT and curative operations (respectively p<0.001 and p=0.001) in terms of OS, but not between the groups which had definitive RT and curative operations. The median event free survival (EFS) rate was 9.9 months, with rates of 46% and 19% at 3 and 5 years, respectively. On univariate analysis of EFS rate with ECOG-PS, weight loss and staging, statistical significance was found only for thorax computerized tomography (CT)+18F-fluorodeoxy-glucose positron emission tomography-CT (PET-CT) use, stage and primary treatment (p<0.20). In multivariate analysis with EFS, only the primary treatment was statistically significant (p=0.001). In the group receiving non-curative treatment, the median EFS was 10.5 months while in the curative operation group it was 14.7 months. When all the primary treatment groups were taken into consideration, grade III/IV side effect swas observed in 57 patients (46.6%). Esophagitis was most prominent among those that received definitive radiotherapy. Conclusions: Independent prognostic factors among these 122 heterogeneous LA-NSCLC T4 N0-3 M0 patients were age at diagnosis, ECOG-PS, stage and primary treatment, the last also being a significant prognostic indicator of EFS. Our findings point to the importance of appropriate staging and a multidisciplinary approach with modern imaging methods in this patient group. In those with T4 lesions, treatment selection and the effective use of curative potential should be the most important goal of clinical care.

두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교 (Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases)

  • 김동욱;윤명근;박성용;이세병;신동호;이두현;곽정원;박소아;임영경;김진성;신정욱;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권2호
    • /
    • pp.89-94
    • /
    • 2008
  • 토모치료기는 선형가속기에서 사용되는 세기 변조방사선치료와 Mega-voltage Computed Tomography (MVCT) 3차원 영상정보에 의한 영상유도방사선치료(Image Guide Radiation Therapy, IGRT)가 가능하고 나선식 빔 조사를 통해 표적과 정상조직에 효율적으로 선량(dose)을 집중하고 분산할 수 있다는 장점을 가진다. 이에 본 논문에서는 2006년 9월부터 운용을 시작한 국립암센터의 토모치료기를 이용하여 10명의 두경부암 환자를 대상으로 토모치료계획과 선형가속기기반 세기변조방사선치료계획의 선량분포를 비교하였으며 또한, 영상유도 방사선치료장치가 구비되지 못하여 환자의 위치보정이 부정확한 구형 세기변조방사선치료기에 대해 표적의 움직임에 따라 균일성(Homogeneity)과 정상조직부작용율(Normal Tissue Complication Probability, NTCP)이 상대적으로 어떻게 변화하는지 연구하였다. 이 연구를 위하여 토모치료기의 치료계획용 시스템인 Hi-Art (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Doming Way, Madison, WI S3717-1954, USA)와 선형가속기기반 세기변조방사선치료계획용 시스템인 CadPlan (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA)을 이용한 역치료계획(inverse Planning)이 수행되었으며 치료계획은 각각의 환자에 대해 같은 표적과 최적화조건을 가지도록 고려되었다. 총 10명의 환자를 대상으로 한 연구결과, 환자의 신체내 외부가 완전히 고정되어 있는 이상적인 경우에 대해서 토모치료기를 이용한 치료계획이 선형가속기에 의한 세기 변조 방식보다 표적에 대해 보다 높고 일정한 선량분포를 주면서도 주변 장기의 선량이 선량체적 히스토그램(Dose Volume Histogram, DVH)에서 오히려 감소함을 보여 주었다 또한 토모치료기의 MVCT를 이용하여 한 달간 토모 환자의 표적위치변화를 측정하였고, 이를 토대로 평균 표적위치변화를 고려하였을 경우 선형가속기기반 세기변조방사선치료계획인 CadPlan에서 표적의 등가균질선량(Equivalant Uniform Dose, EUD)이 감소하고 정상조직의 부작용율의 발생가능성이 상대적으로 증가함을 발견하였다.

  • PDF

T-Scan II 시스템을 이용한 측두하악장애 환자의 교합 분석 (Occlusal Analysis of the Patients with Temporomandibular Disorders Using T-Scan II System)

  • 양동효;이원섭;김미은
    • Journal of Oral Medicine and Pain
    • /
    • 제32권1호
    • /
    • pp.105-111
    • /
    • 2007
  • 측두하악장애가 교합접촉 양상에 영향을 주는지에 관해 오랫동안 연구가 계속되어 왔으나 아직 명확한 결론을 내리지 못하고 있다. 본 연구의 목적은 편측성 측두하악장애 환자에서 증상측과 무증상측 사이의 교합접촉 양상을 비교하고 치료 전후 변화를 평가하고자 하였다. 단국대학교 치과대학부속병원 구강내과에 내원한 측두하악장애 환자 중 편측 증상만을 가진 환자 36명을 대상으로 T-Scan II system (Tekscan, INC., USA)을 사용하여 치료 전후의 교합접촉 양상을 평가하였다(남:녀=7:29, 평균 $29.2{\pm}14.8$세). 좌우측의 접촉점 수(number of contact point), 접촉력(contact force), 상대적 접촉력(relative contact force, %)을 조사하여 치료 전후의 좌우 균형성을 비교하였다. 연구 결과, 치료 전 환자의 증상측은 무증상측에 비해 접촉점 수와 접촉력이 감소되었으나(접촉점 수: p=0.056, 접촉력: p=0.060), 치료 후에는 증가되어 양측간에 차이를 보이지 않았다. 증상측의 접촉점 수와 접촉력이 치료 전후에 차이를 보인 반면(접촉점 수: p=0.038, 접촉력: p=0.052), 비이환측은 치료에 따른 유의한 변화를 보이지 않았다. 악궁 내 좌우 균형성을 평가하는 상대적 접촉력의 차이를 비교했을 때, 치료 전 양측간 차이가 약 27%였다가 치료 후에 약 12%로 유의하게 감소되었다(p=0.001). 이와 같은 결과로 볼 때, 편측성 측두하악장애 환자에서는 교합접촉 양상의 좌우불균형을 보이지만, 보존적 치료 후에 그 차이가 현저하게 감소되어 보다 대칭적이고 균형적인 교합을 회복하며 접촉점 수와 접촉력이 증가하는 것으로 생각된다.

기업의 온라인 고객 서비스가 기업의 수익 및 고객의 후생에 미치는 영향에 관한 연구 (Impact of Net-Based Customer Service on Firm Profits and Consumer Welfare)

  • 김은진;이병태
    • Asia pacific journal of information systems
    • /
    • 제17권2호
    • /
    • pp.123-137
    • /
    • 2007
  • The advent of the Internet and related Web technologies has created an easily accessible link between a firm and its customers, and has provided opportunities to a firm to use information technology to support supplementary after-sale services associated with a product or service. It has been widely recognized that supplementary services are an important source of customer value and of competitive advantage as the characteristics of the product itself. Many of these supplementary services are information-based and need not be co-located with the product, so more and more companies are delivering these services electronically. Net-based customer service, which is defined as an Internet-based computerized information system that delivers services to a customer, therefore, is the core infrastructure for supplementary service provision. The importance of net-based customer service in delivering supplementary after-sale services associated with product has been well documented. The strategic advantages of well-implemented net-based customer service are enhanced customer loyalty and higher lock-in of customers, and a resulting reduction in competition and the consequent increase in profits. However, not all customers utilize such net-based customer service. The digital divide is the phenomenon in our society that captures the observation that not all customers have equal access to computers. Socioeconomic factors such as race, gender, and education level are strongly related to Internet accessibility and ability to use. This is due to the differences in the ability to bear the cost of a computer, and the differences in self-efficacy in the use of a technology, among other reasons. This concept, applied to e-commerce, has been called the "e-commerce divide." High Internet penetration is not eradicating the digital divide and e-commerce divide as one would hope. Besides, to accommodate personalized support, a customer must often provide personal information to the firm. This personal information includes not only name and address, but also preferences information and perhaps valuation information. However, many recent studies show that consumers may not be willing to share information about themselves due to concerns about privacy online. Due to the e-commerce divide, and due to privacy and security concerns of the customer for sharing personal information with firms, limited numbers of customers adopt net-based customer service. The limited level of customer adoption of net-based customer service affects the firm profits and the customers' welfare. We use a game-theoretic model in which we model the net-based customer service system as a mechanism to enhance customers' loyalty. We model a market entry scenario where a firm (the incumbent) uses the net-based customer service system in inducing loyalty in its customer base. The firm sells one product through the traditional retailing channels and at a price set for these channels. Another firm (the entrant) enters the market, and having observed the price of the incumbent firm (and after deducing the loyalty levels in the customer base), chooses its price. The profits of the firms and the surplus of the two customers segments (the segment that utilizes net-based customer service and the segment that does not) are analyzed in the Stackelberg leader-follower model of competition between the firms. We find that an increase in adoption of net-based customer service by the customer base is not always desirable for firms. With low effectiveness in enhancing customer loyalty, firms prefer a high level of customer adoption of net-based customer service, because an increase in adoption rate decreases competition and increases profits. A firm in an industry where net-based customer service is highly effective loyalty mechanism, on the other hand, prefers a low level of adoption by customers.

자궁경부암의 3D-CRT와 IMRT시 소장전위장치의 소장 선량에 대한 영향 (Small Bowel Sparing Effect of Small Bowel Displacement System in 3D-CRT and IMRT for Cervix Cancer)

  • 강민규;허승재;한영이;박 원;주상규;김경주;이정은;박영제;남희림;임도훈;안용찬
    • Radiation Oncology Journal
    • /
    • 제22권2호
    • /
    • pp.130-137
    • /
    • 2004
  • 목적 : 자궁경부암의 방사선치료 시 3차원입체조형방사선치료(3D-CRT)와 세기조절방사선치료(IMRT)는 소장의 방사선 조사선량을 감소시킬 수 있으며, 소장전위장치(SBDS)는 골반강 내의 소장 용적을 감소시킬 수 있다고 알려져 있다. 본 연구는 SBDS를 사용한 3D-CRT와 IMRT 계획을 SBDS를 사용하지 않은 계획과 비교하여, SBDS의 소장 조사선량에 대한 영향을 평가하였다 대상 및 방법 : 자궁경부암으로 근치적 방사선치료를 받은 10명의 환자를 대상으로 하였다. 각 환자에 대하여 스티로폼 압박기구와 환자에게 개별적으로 제작되는 고정기구로 구성된 SBDS를 제작하였고, SBDS가 있는 상태와 없는 상태로 복와위에서 전산화단층촬영(CT)을 시행하였다 3D-CRT는 4-field box technique을, IMRT는 15 MV X-선 7 조사문을 이용하여 계획하였으며, 회전중심점에 50 Gy (25회 분할)를 처방하였다. 비교 분석은 SBDS의 사용에 따른 소장 용적의 변화와 네 가지 계획의 소장의 선량체적히스토그람의 차이를 10 Gy 단위로 paired f-test를 이용하여 분석하였다. 결과 : 소장의 용적은 SBDS를 사용하였을 때 평균 522 cm$^{3}$에서 262 cm$^{3}$로 49.8$\%$ 감소되었다. 10 Gy부터 50 Gy까지 10 Gy 간격으로 일정한 조사선량을 받는 소장의 용적은 SBDS를 사용하였을 때 3D-CRT에서65$\~$80$\%$, IMRT에서 54$\~$67$\%$ 감소하였다. 3D-CRT와 IMRT를 서로 비교하면, 20 Gy부터 50 Gy까지 10 Gy간격으로 일정한 조사선량을 받는 소장 용적은 SBDS를 사용하지 않은 경우에는 IMRT가 6$\~$7$\%$ 정도 유의하게 적었으나 SBDS를 사용한 경우에는 1$\%$ 이내로 차이가 없었다. 결론 : 3D-CRT와 IMRT에서 SBDS를 사용할 때 소장의 조사선량을 더 감소시킬 수 있었으므로, SBDS를 치료에 이용하면 소장의 부작용을 더 감소시킬 수 있을 것이다.

전수면박탈이 정상인의 미세운동수행 능력에 미치는 영향 (Effects of Total Sleep Deprivation on Fine Motor Performance)

  • 이헌정;송형석;함병주;서광윤;김린
    • 수면정신생리
    • /
    • 제8권2호
    • /
    • pp.129-137
    • /
    • 2001
  • 목 적 : 일상생활에서 하루 밤의 수면박탈은 흔히 있을 수 있다. 저자들은 전산화 신경인지검사를 통하여 38시간의 수면 박탈이 상지의 미세 운동수행능력에 어떠한 변화를 주는지를 연구하고자 하였다. 방 법 : 고려대학교 의과대학에 재학중인 학생중 정신적, 신체적으로 건강한 지원자 24명(M:F=21:3, mean age : $24.67{\pm}1.37$)을 대상으로 하였으며 모두 오른 손잡이었다. 또한 수면일지를 작성하게 하여 평소에 수면부족을 보이는 군은 배제하였다. Vienna Test System에서 나타날 수 있는 학습효과를 최소화하기 위하여 검사 하루 전에 미리 같은 검사를 시행하였다. 검사 전날 밤에 피험자들은 충분한 수면을 취하였으며, 검사 당일 오전 6시경에 기상하였다. 실험 첫날 오전 6시부터 다음날 오후 8시까지 38시간동안 수면을 박탈하였으며, 검사 첫날과 둘째 날의 오전 7시와 오후 7시, 총 4차례 Vienna Test System중 Motor Performance Series를 시행하였다. 실험기간 중에 모든 피험자에게 수면에 영향을 줄 수 있는 약물의 복용은 금지되었으며, 과도한 운동도 금지되었다. 자료는 SPSS를 이용하여 피험자당 4회 시행한 검사 결과를 Repeated ANOVA를 시행하였으며, 일중리듬을 고려하여 각 아침, 저녁 session끼리의 검사 결과를 paired t-test를 시행하여서 비교하였다. 결 과 : Motor Performance Series에서 수면박탈에 따라서 상지의 오른손의 운동 기능에 있어 수행능력의 저하가 나타났다. 각 소검사를 보면 tapping의 total number(p<.005), line tracking의 number of misses(p<.05), length of misses (p<.05), inserting short pin의 total length(p<.01), inserting long pin의 total length(p<.05), aiming의 number of misses (p<.05)에서 통계적으로 유의미한 기능의 저하가 나타났다. 결 론 : 이상의 결과는 38시간의 수면박탈만으로도 유의미한 운동기능의 저하가 나타난다는 것을 보여준 것이며, 특히 가장 예민하게 미세 운동기능을 발휘할 수 있는 우세한 오른손에서 기능저하가 나타났다. Inserting long pin보다는 inserting short pin 검사에서 기능이 저하되었고, line tracking, aiming에서 검사 결과의 수행 저하가 두드러진 것으로 보아서, 미세한 운동기능일수록 영향을 많이 받는다고 할 수 있겠으며, line tracking에서 전체 검사 시간은 감소되며, 수행에서 실수가 늘어난 것으로 보아, 수면박탈에 따라서 조급한 수행이 이루어진다고 보여진다. 또한 주어진 32초간의 시간 안에 최대한의 속도로 펜을 두드리는 tapping 검사에서 두드러진 저하를 보인 점에서, 수면박탈에 의하여 근육의 피로가 쉽게 나타난다고 생각 할 수 있겠다.

  • PDF

T-Scan II 시스템을 이용한 습관적 편측저작자들의 교합 분석 (Occlusal Analysis of the Subjects with Chewing Side Preference Using the T-Scan II System)

  • 박은희;김미은;김기석
    • Journal of Oral Medicine and Pain
    • /
    • 제31권3호
    • /
    • pp.245-254
    • /
    • 2006
  • 구강안면 영역의 통증이나 치아결손, 부정교합 같은 치아적 요소가 편측저작습관의 주요요인으로 여겨지나, 치아적 요소가 선호하는 저작측에 영향을 주지 않는다는 연구들도 있다. 본 연구에서는 컴퓨터화된 교합분석 시스템인 T-Scan II 시스템을 사용하여 편측으로 저작하는 대상자와 양측으로 저작하는 대상자 사이에 교합양상의 특이점이 있는지 조사하고 편측 저작자의 주저작측과 비저작측 사이의 차이를 함께 평가하고자 하였다. 편측저작습관에 대한 설문을 통하여 20명의 편측 저작자(평균 $25.25{\pm}2.84$세)와 20명의 양측 저작자(평균 $27.00{\pm}5.07$세)를 선정하였으며 치아적 문제나 악골의 통증이나 기능이상 같은 문제가 있는 경우는 모두 제외하였다. 습관적 폐구와 측방운동시의 교합양상은 T-Scan II 시스템을 이용하여 측정하였다. 습관적 폐구는 시간에 따라 초기, 중기, 말기로 나누었다. 각 세 단계에서의 접촉점의 수와 교합력의 비율을 좌우 양측으로 나누어 조사하였다. 습관적 페구 동안의 경과시간 및 치아 활주면적, 좌우측 각각의 측방운동시간이 측정되었다. 편측 저작 습관을 가진 사람들의 경우 양측 저작을 하는 사람에 비해서 치아의 평균 교합 면적이 작았다(p<0.005). 습관적 편측저작자에서 저작측과 비저작측을 비교해보았을 때 비저작측의 교합면적은 저작측에 비해 작았으나 (p<0.005), 편측저작자의 저작측과 양측저작군의 어느 한쪽의 교합면적 사이에는 유의한 차이가 없었다. 최초접촉부터 최대교두감합위까지의 경과 시간 및 측방운동 시간, 치아의 활주 면적 및 교합력의 좌우 비율도 양측저작군과 편측저작군 사이에 유의한 차이가 없었다. 이러한 결과는 저작시 좌우측 중 교합면적이 작은 측을 피하여 교합효율이 높은 방향으로 저작을 한다는 것을 의미한다.

microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구 (The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System)

  • 조영갑;박성용;최진호;김헌정;김우철;노준규;김주영
    • Journal of Radiation Protection and Research
    • /
    • 제23권4호
    • /
    • pp.259-266
    • /
    • 1998
  • Nucletron사의 microSelectron-High Dose-Rate(HDR) System에서 부인암의 강내 근접치료에 사용되는 Standard shielded applicator set(SSAS)와 Fletcher-Williamson applicator set(FWAS)는 standard applicator set(SAS)와 비교해서 다른 점이 ovoids 위와 아래 부분에 방광과 직장으로 가는 선량을 줄이기 위해 각각 스테인레스 강철(밀도 ${\varrho}=8,000\;kg/m^3$)과 텅스텐 합금(밀도 ${\varrho}=14,000\;kg/m^3$)으로 차폐가 되어 있다. 이에 본 연구에서는 특별히 고안한 지지장치를 사용해서 국제방사선단위위원회(ICRU) 보고서 38에서 권고한 직장과 방광의 위치에 대하여 두 shielded ovoids의 차패효과가 어느 정도인가를 알아보고자 하였다. 지지장치를 PTW사의 전산화된 3차원 물펜톰에 부착하고 SAS의 ovoids를 지지장치에 고정하였다. Ovoids의 끝 부분을 전리함(PTW 0.125cc)의 측정점 높이와 일치시키고 전리함을 좌우로 이동시키면서 선량을 측정하여 두 ovoids의 중간 위치를 확인하였다. 직장에 미치는 선량은 ovoids의 중간에 위치한 선원 M5로부터 posterior방향으로 수직으로 위치한 점들인 20(Rl) 25(R2) 30(R3) 40(R4), 50(R5), 60(R6) mm에서 측정하였다. 방광에 미치는 선량은 M5로부터 anterior방향으로 수직으로 위치한 점들인 20(Bl), 30(B2), 40(B3), 50(B4), 60(B5) mm에서 측정하였다 위와 같은 방법으로 SSAS와 FWAS의 ovoids에서도 각각의 점들에 대한 선량을 측정하였다. SAS와 SSAS의 직장에 미치는 선량차이는 실제 임상에서의 관심 점들과 가장 가까운 25 mm(R2)와 30 mm(R3)거리에서 각각 8.0% 6.0%였고 SAS와 FWAS의 직장에 미치는 선량차이는 25 mm(R2) 와 30 mm(R3)거리에서 각각 25.0% 23.0%로 나타났다. SAS와 SSAS의 방광에 미치는 선량차이는 20 m(Bl)와 30 mm(B2)거리에서 각각 8.0% 3.0%였고 SAS와 FWAS의 방광에 미치는 선량차이는 20 mm(Bl)와 30 mm(B2)거리에서 각각 23.0%, 17.0%로 나타났다. SAS를 SSAS나 FWAS로 대체하였을 때 직장에 미치는 선량은 SSAS는 최대 8.0 %, FWAS는 최대 26.0 %까지 감소되고 방광에 미치는 선량은 SSAS는 최대 8.0 % FWAS는 최대 23.0%까지 감소됨을 알 수 있었고 FWAS가 SSAS 보다 차폐효과가 더 좋은 것으로 나타났으며 이 두 종류의 shielded applicator set는 부인암의 근접치료시 직장과 방광으로 가는 선량을 감소시켜 환자치료의 최적화를 이룰 수 있을 것으로 생각된다.

  • PDF