• Title/Summary/Keyword: Computerized

Search Result 1,817, Processing Time 0.026 seconds

Diagnosis of Fatty Liver Complicated by Simple Obesity in Children: Serum ALT and Its Correlation with Abdominal CT and Liver Biopsy (소아의 단순성 비만증에 의한 지방간의 진단: ALT치와 복부 전산화단층촬영 및 간생검 소견간의 상관관계)

  • Lee, Seong-Hee;Kim, Hwa-Jung;Oh, Jae-Cheol;Han, Hae-Jeong;Kim, Hee-Sup;Tchah, Hann;Park, Ho-Jin;Shin, Mi-Keong;Lee, Min-Jin;Lee, Sang-Chun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.2 no.2
    • /
    • pp.153-163
    • /
    • 1999
  • Purpose: The purpose of our study is to provide useful information for diagnostic methods of fatty liver by childhood simple obesity and to provide correlation between serum alanine aminotransferase (ALT) for screening test and abdominal computerized tomography (CT) and liver biopsy for confirmative diagnostic methods of fatty liver. Methods: Among 78 obese childrens who visited our hospital, CT was carried out in 26 childrens. Of these, liver biopsy was carried out in 15 childrens who had high obesity index or severe elevated ALT. Based on the level of serum ALT, 26 cases were classified into 3 groups, and compared with physical measurements and degree of fatty infiltration on CT and liver biopsy. Results: 1) Correlation between ALT and physical measurements: Of 26 obese children, ALT was abnormally elevated (>30 IU/L) in 17 cases (67.4%) but there was no significant correlation between ALT and physical measurements (p>0.05). 2) Correlation between degree of fatty infiltration on CT and ALT: Of 26 cases, 13 cases (50%) revealed fatty liver on CT. The degree of fatty liver on CT had significant correlation with elevation of ALT (p<0.05). 3) Correlation between the degree of fatty infiltration on liver biopsy and ALT: Liver biopsy was performed in 15 cases of which 14 cases revealed fatty liver. But one case had normal hepatic histology with severe obesity and normal ALT. Fourteen fatty liver cases on liver biopsy were classified into 3 groups by the degree of fatty infiltration and analysed with obesity index and ALT. The histologic hepatic steatosis had no significant correlation with obesity index (p>0.05), but significant correlation with ALT (p<0.05). 4) Correlation between CT and liver biopsy finding: Both CT and liver biopsy were performed in 15 cases of which 6 cases revealed normal finding on CT and 9 cases manifested fatty liver. There was significant correlation between CT and liver biopsy findings (r=0.6094). Conclusion: The results of our study suggest that abdominal CT and liver biopsy are useful and accurate methods of estimating fatty liver in the childhood obesity. But biochemical abnormalities of routine liver function tests dot not correlate well with severity of the fatty liver and liver injury.

  • PDF

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

Development of a Stock Trading System Using M & W Wave Patterns and Genetic Algorithms (M&W 파동 패턴과 유전자 알고리즘을 이용한 주식 매매 시스템 개발)

  • Yang, Hoonseok;Kim, Sunwoong;Choi, Heung Sik
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.1
    • /
    • pp.63-83
    • /
    • 2019
  • Investors prefer to look for trading points based on the graph shown in the chart rather than complex analysis, such as corporate intrinsic value analysis and technical auxiliary index analysis. However, the pattern analysis technique is difficult and computerized less than the needs of users. In recent years, there have been many cases of studying stock price patterns using various machine learning techniques including neural networks in the field of artificial intelligence(AI). In particular, the development of IT technology has made it easier to analyze a huge number of chart data to find patterns that can predict stock prices. Although short-term forecasting power of prices has increased in terms of performance so far, long-term forecasting power is limited and is used in short-term trading rather than long-term investment. Other studies have focused on mechanically and accurately identifying patterns that were not recognized by past technology, but it can be vulnerable in practical areas because it is a separate matter whether the patterns found are suitable for trading. When they find a meaningful pattern, they find a point that matches the pattern. They then measure their performance after n days, assuming that they have bought at that point in time. Since this approach is to calculate virtual revenues, there can be many disparities with reality. The existing research method tries to find a pattern with stock price prediction power, but this study proposes to define the patterns first and to trade when the pattern with high success probability appears. The M & W wave pattern published by Merrill(1980) is simple because we can distinguish it by five turning points. Despite the report that some patterns have price predictability, there were no performance reports used in the actual market. The simplicity of a pattern consisting of five turning points has the advantage of reducing the cost of increasing pattern recognition accuracy. In this study, 16 patterns of up conversion and 16 patterns of down conversion are reclassified into ten groups so that they can be easily implemented by the system. Only one pattern with high success rate per group is selected for trading. Patterns that had a high probability of success in the past are likely to succeed in the future. So we trade when such a pattern occurs. It is a real situation because it is measured assuming that both the buy and sell have been executed. We tested three ways to calculate the turning point. The first method, the minimum change rate zig-zag method, removes price movements below a certain percentage and calculates the vertex. In the second method, high-low line zig-zag, the high price that meets the n-day high price line is calculated at the peak price, and the low price that meets the n-day low price line is calculated at the valley price. In the third method, the swing wave method, the high price in the center higher than n high prices on the left and right is calculated as the peak price. If the central low price is lower than the n low price on the left and right, it is calculated as valley price. The swing wave method was superior to the other methods in the test results. It is interpreted that the transaction after checking the completion of the pattern is more effective than the transaction in the unfinished state of the pattern. Genetic algorithms(GA) were the most suitable solution, although it was virtually impossible to find patterns with high success rates because the number of cases was too large in this simulation. We also performed the simulation using the Walk-forward Analysis(WFA) method, which tests the test section and the application section separately. So we were able to respond appropriately to market changes. In this study, we optimize the stock portfolio because there is a risk of over-optimized if we implement the variable optimality for each individual stock. Therefore, we selected the number of constituent stocks as 20 to increase the effect of diversified investment while avoiding optimization. We tested the KOSPI market by dividing it into six categories. In the results, the portfolio of small cap stock was the most successful and the high vol stock portfolio was the second best. This shows that patterns need to have some price volatility in order for patterns to be shaped, but volatility is not the best.

The Application of 3D Bolus with Neck in the Treatment of Hypopharynx Cancer in VMAT (Hypopharynx Cancer의 VMAT 치료 시 Neck 3D Bolus 적용에 대한 유용성 평가)

  • An, Ye Chan;Kim, Jin Man;Kim, Chan Yang;Kim, Jong Sik;Park, Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.41-52
    • /
    • 2020
  • Purpose: To find out the dosimetric usefulness, setup reproducibility and efficiency of applying 3D Bolus by comparing two treatment plans in which Commercial Bolus and 3D Bolus produced by 3D Printing Technology were applied to the neck during VMAT treatment of Hypopahrynx Cancer to evaluate the clinical applicability. Materials and Methods: Based on the CT image of the RANDO phantom to which CB was applied, 3D Bolus were fabricated in the same form. 3D Bolus was printed with a polyurethane acrylate resin with a density of 1.2g/㎤ through the SLA technique using OMG SLA 660 Printer and MaterializeMagics software. Based on two CT images using CB and 3D Bolus, a treatment plan was established assuming VMAT treatment of Hypopharynx Cancer. CBCT images were obtained for each of the two established treatment plans 18 times, and the treatment efficiency was evaluated by measuring the setup time each time. Based on the obtained CBCT image, the adaptive plan was performed through Pinnacle, a computerized treatment planning system, to evaluate target, normal organ dose evaluation, and changes in bolus volume. Results: The setup time for each treatment plan was reduced by an average of 28 sec in the 3D Bolus treatment plan compared to the CB treatment plan. The Bolus Volume change during the pretreatment period was 86.1±2.70㎤ in 83.9㎤ of CB Initial Plan and 99.8±0.46㎤ in 92.2㎤ of 3D Bolus Initial Plan. The change in CTV Min Value was 167.4±19.38cGy in CB Initial Plan 191.6cGy and 149.5±18.27cGy in 3D Bolus Initial Plan 167.3cGy. The change in CTV Mean Value was 228.3±0.38cGy in CB Initial Plan 227.1cGy and 227.7±0.30cGy in 3D Bolus Initial Plan 225.9cGy. The change in PTV Min Value was 74.9±19.47cGy in CB Initial Plan 128.5cGy and 83.2±12.92cGy in 3D Bolus Initial Plan 139.9cGy. The change in PTV Mean Value was 226.2±0.83cGy in CB Initial Plan 225.4cGy and 225.8±0.33cGy in 3D Bolus Initial Plan 224.1cGy. The maximum value for the normal organ spinal cord was the same as 135.6cGy on average each time. Conclusion: From the experimental results of this paper, it was found that the application of 3D Bolus to the irregular body surface is more dosimetrically useful than the application of Commercial Bolus, and the setup reproducibility and efficiency are excellent. If further case studies along with research on the diversity of 3D printing materials are conducted in the future, the application of 3D Bolus in the field of radiation therapy is expected to proceed more actively.

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

An experimental study on the impact of an agreement on the means to achieve nursing goals in the early postpartum period of primiparous mothers and enhance their self-confidence and satisfaction in maternal role performance (산욕초기 초산모의 간호목표달성방번 합의가 어머니 역할수행에 대한 자신감 및 만족도에 미치는 영향에 관한 실험적 연구)

  • 이영은
    • Journal of Korean Academy of Nursing
    • /
    • v.22 no.1
    • /
    • pp.81-115
    • /
    • 1992
  • The problem addressed by this study was to determine the effect of nurse - patient agreement on the means to achieve nursing goals in the early postpartum period of primiparous mothers. It was hypothesized that the experimental treatment would result in hegher self-confidence and satisfaction in maternal role performance. This purpose was to contribute to the planning of nursing care to enhance self- confidence and satisfaction in maternal role performance and to the development of relevant nursing theory. Especially, the early postpartum period is crucial toward in recovery from childbirth and attainment of the maternal role. Maternal role attaintment is a complex social and cognitive process of stimulus -response accomplished by learning. Most women attain the maternal role sucessfully. But, some primiparous mothers experience difficultites in attainment of the maternal role due to lack of experience and knowledge. Self-confidence and satisfaction in maternal role performance are important factors in attainment and adjustment to the maternal role (Mercer, 1981a, 1981b ; Lederman, Weigarten, and Lederman, 1981 :Bobak and Jensen, 1985). Nursing is defined as behaviors of nurses add patients that attain nursing goals through action, reaction, interaction, and transaction. For attainment of nursing goals, active participating transactions must occur by agreement on the means to achieve those goals through nurse -patient mutual goal setting and establishment of their active relationships(King, 1981, Ha, 1977). Based on King's theory of goal attainment (1981), this stuy was planned as a non-equivalent control group, non -synchronized quasi -experimental design using agreement on the means to achieve nursing goals in early postpartum as the experimental treatment. The data were collected from July 20 to Sep. 1, 1991 by questionnaires with 60 primiparous mothers planing to breast feed after normal deliveries at W hospital in Pusan, Korea. The subjects were divided into a control group(conventional group) -those admitted from July 20 to Aug. 12, and an experimental group(agreement group) - those admitted from Aug. 13 to Sep. 1. The instument for agreement on the means to nursing goals in the early postpartum period included five steps - identification of disturbances of problems through action, reaction, and interaction with primiparous mothers : mutual early postpartal nursing goal setting : exploration of the means to achieve goals ; agreement on the means (self- care, ealry maternal -infant contact, performance of mothering behavior, and communicating about the infant's behavior and health condition) : implementation of the means. This instrument was developed on the basis of King's elements that lead to transactions in nurse-patient interactions. Lederman et al's (1981) scale for Confidence in ability to cope with tasks of motherhood and Lederman et al's(1981) scale for Mother's satisfaction with motherhood and infant care were used to measure self-confidence and satisfaction in maternal role performance ·with the subjects immediately after admission and on the day of discharge. Self-care performance in the experimental group was measured by self -evaluation tool developed by the investigator from the literature concerned. The tools to measure Pelf-confidence and satisfaction in maternal role performance, and the tool to measure self-evaluation of self-care performance were tested for internal reliability. Cronbach's Alphas were 0.94, 0.94, and 0.63. The data were analysed by using in S.P.S.S. computerized program and included percentage, x²-test, t-test, ANOVA, and Pearson Correlation Coefficient. The conclusions obtained from this study are summerized as follows : 1. The degree of self-confidence in maternal role performance of the total subjects group measured before the experimental treatment was above average with a mean score of 2.77(range 2.14-3.64). Out of 14 items, those with relatively high mean scores were ‘I would like to be a better mother than I am’(3.95), and ‘I have my doubts about whether I am a good mother’(2.87). Those with low mean scores were ‘I know that my baby wants most of the times’(2.28), ‘When the baby cries, I can tell what she /he wants’(2.37), and ‘I have confidence in my ability to care for the baby’(2;50). That is, the self - confidence of Primiparous mothers was considerably high in mothering, but rather low in activities concerning the infant care and understanding of the infant behavior. The degree of satisfaction in maternal role performance of the total subjects group measured before the experimental treatment was high with a mean score of 3.18(range 1.92-3.92). Out of 13 items, those with relatively high mean scores were ‘I am glad 1 had this baby now’(3.75), ‘I play with the baby between feedings when s/he is awake and quiet’(3.67), and ‘I enjoy being a mother’(3.27). Those with low mean scores were ‘I am upset about having too many responsibilities as a mother’(2.78), ‘It bothers me to get up for the baby at night’(2.82), and ‘I get annoyed if the baby frequently interrupts my activities’.(2.82), That is, the satisfaction of primiparous mothers was considerably high in mothering and infant care, but rather low in restraints in time or on the mother's self accomplishment and development. 2. Agreement on the means to achieve nursing goals in the early postpartum period included process of mutual goal setting, exploration of the means to achieve goals, and ahreement in concert means to achieve goals based on the mothers' condition, concerns, self-perception of the nurse - patient interactions. In the process of agreement, there was agreement that the means to achieve goals should be through trust and establishment of active relationships with the nurse through identification of problems according to planned nursing goals and active interaction, such as explanations, teaching, changing of opinions, acceptance or rejection of explanations, and proposing of questions. Therefore agreement on the means to achieve nursing goals in the early postpartum period appears to be an effective nursing intervention for primiparous mothers. 3. The degree of self- confidence in maternal role performance of the exprimental group was higher than that of the control group(t=3.95, p<0.01). Out of 14 items, those with higher score in the experimental group were ‘I would like to be a better mother than I am’(t=1.93, p<0.05), ‘I know that my baby wants most of the times’(t=2.75, p<0.01), ‘When the baby cries, 1 can tell what she/he wants’(t=2.10, p<0.05), ‘I have confidence in my ability to care for the baby’(t=3.72, p<0.01), ‘I trust my own judement in deciding how to care for the baby’(t=1.96, p<0.05), ‘I feel that I know my baby and what to do for him /her’(t=2.44, p<0.01), ‘I am concerned about being able to meet the baby's needs’(t=2.87, p<0.01), ‘I know what my baby likes and dislikes’(t=3.26, p<0.01), ‘I don't know to care for the baby as well as I should’(t=2.07, p<0.05), and ‘I am unsure about whether I give enough attention to the baby’(t=3.04, p<0.01), That is, the degree of self-confidence in mothering, activities concerning infant care, and understanding of infant behavior of the experimental group was higher than that of the control group. Therefore, the first hypothesis, that the degree of self-confidence in maternal role performance of the experimental group would be higher than that of the control group, was supported(t=3.95, p<0.01). 4. The degree of satisfaction in the maternal role performance of the exprimental group was higer than that or the control group(t=2.31, p<0.05). Out of 13 items, those with higher score in the experimental group were ‘I am glad I had this baby now’(t=2.29, p<0.05), ‘I enjoy taking care of the baby’(t=2.4g, p<0.01), ‘It is boring for me to care for the baby and do the same thing over and over’(t=2.87, P<0.01), ‘I am unhappy with the amount of time I have for activities other than childcare’(t=2.51, p<0.01), and ‘When bathing and diapering the baby, I would like to be doing something else’(t=2.43, p<0.01). That is, the degree of satisfaction in mothering, infant care, and restraints in time of on the mother's self accomplishment and development in the experimental group was higher than that of the control group. Therefore, the second hypothesis, that the degree of satisfaction in maternal role performance of the experimental group would be higher than that of the control group, was supported(t=2.31, p<0.05). 5. The third hypothesis, that the higher the degree of satisfaction in materenal role performance, the higher the degree of self-confidence in materenal role performance in the experimental group, was supported (r=0.57, p<0.01)

  • PDF

A Study on the Sasang Constitutional Distribution Among the People in the United States of America (북미지역주민(北美地域住民)의 사상체질(四象體質) 분포(分布)에 관(關)한 연구(硏究))

  • Koh, Byung-hee;Kim, Seon-ho;Park, Byung-gwan;Lavelle, Jonathan D;Tecun, Marianne;Anthony Jr., Ross;Hobbs, Ron;Zolli, Frank;Chin, Kyung-hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.11 no.2
    • /
    • pp.119-150
    • /
    • 1999
  • In spite of recent remarkable recent development in both western and oriental medical sciences, there is still only a shallow understanding of individual differences for various prognoses of incurable diseases and immunopathy diseases. Nevertheless, the care, cure and prevention methods of Sasang Constitutional Medicine are broadly used as an effective treatment of incurable diseases like immunopathy diseases and stress-related diseases and diseases due to aging. In this sense, the establishment of classification norms is urgent and essential for the worldwide application of Sasang Constitutional Medicine(SCM). This study began with the confirmation process of whether Sasang Constitutional types exist in Americans. To accomodate for cultural differences, the distinguishing tool was readjusted so that Sasang Constitutional Types in Americans could be determined. Hence, the selected tool is the new QSCCII+, which is a newly revised English version of the QSCCII. QSCCII was made and standardized by Dept. of SCM in Kyung Hee Medical Center and Dr. Kim7). The evaluation methods of the old version were improved in the new QSCCII+ through necessary statistical manipulation. The original QSCCII was officially authorized by the Korean Society of Sasang Constitutional Medicine as the only computerized version of Sasang diagnostics. This study is the first attempt to design a new diagnostic tool for the classification of Sasang Constitutional types in North Americans with the revision of QSCCII. The subjects of this study were selected from the cooperative people among the students and staffs of the University of Bridgeport and the patients who visited the Clinic in the Health Science Center. This study takes for about 1 year from 1998. 8 to 1999. 8 The conclusions of the study can be summarized as follows: 1. Sasang constitutional types also exist in Americans. It can also naturally be inferred that Sasang Constitutional types exist in all human beings, for there are many different human races in America. 2. There are more So-Yang In's than any other types in American white people. This result confirms the hypothesis that there also exist Sasang Constitutional types in westerners. 3. The result of repetitive tests suggests that the new QSCCII+ is an effective diagnostic tool for westerners when we consider the constant diagnostic results of the QSCCII+. 4. Sasang Constitutional types exit in the sample group regardless of racial difference. 5. The question items that were not often checked by Americans need to be modified into more understandable expressions. 6. The standardization of diagnosis for Americans should be established by use of the QSCCII+ 7. It can be guessed that there are many Tae-yang In's among the 71 persons who could not be clearly classified by the QSCCII+. Due to the scarcity of Tae-yang-In in general, it is important to improve upon the discernability of the QSCC II+. 8. The results of the Sasang Constitutional distribution in North Americans are as follows: The percentage of So-yang In distribution in the sample group is 36.25%(87persons), that of Tae-eum In is 13.75%(33persons), and that of So-eum In is 20.41%(49persons).

  • PDF