• Title/Summary/Keyword: Computer simulation experiment

Search Result 727, Processing Time 0.028 seconds

Design of Single Loop Output Voltage Controller for 3 Phase PWM Inverterl (3상 PWM 인버터의 단일루프 전압제어기 설계)

  • 곽철훈;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.561-568
    • /
    • 2003
  • There arc two ways in the output voltage control method in PWM inverters. One Is double loop voltage control composed of inner current control loop and outer voltage control loop.'rho other is single loop voltage control method composed of voltage control loop only. It's characteristics shows lower performance in case of high output impedance than double loop voltage control. However, in case of low output impedance, it shows good control performance in all load ranges than double loop voltage control. In this paper, the rule and the gain of single loop voltage control have been developed analytically and these were verified through computer simulation and experiment.

Design and control of Single Loop Output Voltage Controller for 3 Phase PWM Inverter (3상 PWM 인버터의 단일제어루프 전압제어기의 설계 및 제어)

  • Gang B.H.;Gho J.S.;Cho J.S.;Choe G.H.;Kwak C.H.;Kim J.H,
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.496-500
    • /
    • 2001
  • There are two ways in the output voltage control method in PWM inverter. One is the double loop voltage control composed of inner current control loop and outer voltage control loop. Because it shows fast response and low steady state error, utilized in many application. The Other is single loop voltage control method composed of voltage control loop only. It's characteristics shows lower performance in case of high output impedance than double loop voltage control. But in low output impedance, it shows good control performance in all load range than double loop control. In this paper, single loop voltage control rule and gain was developed analytically, and these were verified through computer simulation and experiment.

  • PDF

Design of a New-Concept VDT Workstation Chair for Improving Work Safety (작업안전성 향상을 위한 신개념 VDT 작업용 의자의 인간공학적 설계)

  • Shin, Jong-Hyun;Park, Min-Yong;Kim, Jung-Yong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.4
    • /
    • pp.459-465
    • /
    • 1999
  • A new-concept VDT workstation chair with adjustable keyboard/mouse support was proposed to minimize physical discomfort and the risk of cumulative trauma disorders (CTDs) at work sites in this study. First, a three-dimensional human modeling tool $(SAFEWORK^{(R)})$ was used to design the new chair satisfying the anthropometric specifications of Korean population. Second, based upon the result of 3-D graphical simulation, a mock-up chair was constructed with an adjustable keyboard/mouse support directly attached to the chair body. Third, muscle fatigue and subjective discomfort were measured to evaluate the newly developed chair. An experiment was conducted to compare the new workstation chair to the traditional computer chair without keyboard/mouse support. Six volunteer subjects participated in six one-hour word-processing sessions with two different chairs and three different postures. Statistical results indicate that the new-concept VDT chair generally improved subjective comfort level and reduced fatigue in finger flexor/extensor and low back muscle. In conclusion, this new VDT workstation chair is expected to reduce physical discomfort and prevent occupational CTD problems in the long run. Implications of the new design and suggestions for the further development are also addressed.

  • PDF

Active Noise Control for Target Point Inside Bore Using Property of MRI Noise (MRI 소음의 특성을 이용한 공동 내부 목표점의 능동소음 제어)

  • Lee, Nokhaeng;Park, Youngjin;Park, Youn-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Recently, MRI(magnetic resonance imager) scanner is continually used for medical diagnosis and many biomedical researches. When it operates, however, intense noise is generated. The SPL(sound pressure level) of the noise approaches 130 dB especially in 3 T(Tesla) MRI. Meanwhile, more than 3 T MRI scanners have been developed to get higher-resolution images, so louder noise is expected in the future. The intense noise makes patients feel nervous and uncomfortable. Moreover, it could possibly cause hearing loss to patient in extreme cases. For this reason, some active noise control systems have been researched. One of them used feedback Filtered-X LMS(FXLMS) algorithm which is able to control only narrowband noises and possible to diverge in severe case. In this paper, we determine the property of MRI noise. Using the property, we applied a method of open-loop and adaptive control for reducing MRI noise at target point inside bore. We verified performance of the method with computer simulation and preliminary experiment. The results demonstrate that the method can effectively reduce MRI noise at target point.

Multidisciplinary Design Optimization for Acoustic Characteristics of a Speaker Diaphragm (스피커 진동판의 음향특성 다분야통합최적설계)

  • Kim, Sung-Kuk;Lee, Tae-Hee;Lee, Surk-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.763-766
    • /
    • 2004
  • Recently, various acoustic artifacts that contains speaker have been produced such as cellular phone. Speaker consists of diaphragm generating sound and coil vibrating diaphragm. Generally, good speaker means that it has a wide frequency range, high output power rate to input power and flat sound pressure level in specified frequency range. Acoustic characteristic was estimated through the experiment and computer simulation, or sound power was controlled with acoustic sensitivity in a natural frequency range fer last decade. However, the flatness of sound pressure level has not been considered to enhance the sound quality of a speaker. Tn this study, a method for speaker design is proposed for a good acoustic characteristic, which is flatness of SPL(sound pressure level) and wideness between the first and second natural frequency. SYSNOISE is used fer acoustic analysis and ANSYS is used for harmonic response analysis and modal analysis. Optimization for acoustic characteristics of a speaker diaphragm is performed using ModelCenter. All analyses are done within a frequency domain. And we confirm that the experimental and computational simulations have similar trend.

  • PDF

Active Vibration Control of Underwater Hull Structure Using Macro-Fiber Composite Actuators (MFC 작동기를 이용한 수중 Hull 구조물의 능동 진동 제어)

  • Kwon, Oh-Cheol;Sohn, Jung-Woo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.138-145
    • /
    • 2009
  • Structural vibration and noise are hot issues in underwater vehicles such as submarines for their survivability. Therefore, active vibration and noise control of submarine, which can be modeled as hull structure, have been conducted by the use of piezoelectric materials. Traditional piezoelectric materials are too brittle and not suitable to curved geometry such as hull structures. Therefore, advanced anisotropic piezocomposite actuator named as Macro-Fiber Composite(MFC), which can provide great flexibility, large induced strain and directional actuating force is adopted for this research. In this study, dynamic model of the smart hull structure is established and active vibration control performance of the smart hull structure is evaluated using optimally placed MFC. Actuating performance of MFC is evaluated by finite element analysis and dynamic modeling of the smart hull structure is derived by finite element method considering underwater condition. In order to suppress the vibration of hull structure, Linear Quadratic Gaussian(LQG) algorithm is adopted. After then active vibration control performance of the proposed smart hull structure is evaluated with computer simulation and experimental investigation in underwater. Structural vibration of the hull structure is decreased effectively by applying proper control voltages to the MFC actuators.

FFT based Monitoring System for Combustion Vibration Data Processing of Gas Turbine (가스터빈 연소진동 데이터 처리를 위한 FFT 기반의 모니터링 시스템)

  • Lee, Sang-Hyeok;Kang, Feel-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2327-2334
    • /
    • 2007
  • This paper presents a method for improvement of communication speed and reduction of data storage space in gas turbine monitoring system to acquire, save, and display combustion vibration data. The proposed method implements FFT from sampled raw data. The FFT result data are encoded to be transferred to monitoring PC for storage. By this way, it can reduce data storage space. To display the received data, it needs inverse FFT to reconstruct original signal. To verify the validity and efficiency of the proposed scheme, computer-aided simulation are carried out. It includes the analyzed results the relationship between FFT's order and Gibb's Phenomenon. Finally, high-performance of the proposed method is proved by combustion experiment results using a prototype gas turbine.

Visual Measurement of Rotational Displacements by Using Two Different Moire Fringes Simultaneously Generated by Repeated Sinusoidal Gratings (반복사인격자에서 동시에 생기는 두 가지 무아레 무늬를 이용한 회전변위의 가시적 측정)

  • Jeong, Youn-Hong;Oh, Jeong-Hyo;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.302-309
    • /
    • 2008
  • We present the precise visual measurement method of rotational displacements using two different moire fringes simultaneously generated by repeated sinusoidal gratings. We investigate the variation of moire fringes depending on rotational displacements through computer simulation and experiment using a rotator in detail. The moire fringes are composed of the wide linear fringe part with a long period and the narrow linear fringe part with a short period. These parts are superior to the angle detection of more than 12 degrees and less than 12 degree, respectively. Additionally, the method can be visually used in the determination of the rotational direction by observing the moire fringe's direction.

Noise and Image Quality Analysis of Brain CT Examination (두부 CT검사에서의 노이즈 및 화질분석)

  • Choi, Seok-yoon;Im, In-chul
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.279-284
    • /
    • 2019
  • The purpose of this study was to find the best protocol for balance of image quality and dose in brain CT scan. Images were acquired using dual-source CT and AAPM water phantom, noise and dose were measured, and effective dose was calculated using computer simulation program ALARA(S/W). In order to determine the ratio of image quality and dose by each protocol, FOM (figure of merits) equation with normalized DLP was presented and the result was calculated. judged that the ratio of image quality and dose was excellent when the FOM maximized. Experimental results showed that protocol No. 21(120 kVp, 10 mm, 1.5 pitch) was the best, the organ with the highest effective dose was the brain(33.61 mGy). Among organs with high radiosensitivity, the thyroid gland was 0.78 mGy and breast 0.05 mGy. In conclusion, the optimal parameters and the organ dose in the protocol were also presented from the experiment, It may be helpful to clinicians who want to know the protocol about the optimum state of image quality and dose.

Design Alterations of a Chamfering Machine Structure for the Improved Surface Quality (가공 제품 품질 향상을 위한 면취장비의 설계 개선)

  • Yi, Il Hwan;Ro, Seung Hoon;Han, Dae Sung;Kim, Young Jo;Kil, Sa Geun;Park, In Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.1
    • /
    • pp.117-122
    • /
    • 2019
  • Pipes are widely used in various industries such as automobile, anti-vibration devices, factories and ship building. Chamfering is one of the most critical processes in pipe manufacturing which removes burrs of the pipes for better surface quality. In most cases, the defects of the chamfered surface are originated from the structural vibrations of the chamfering machine. In this study, the dynamic characteristics of a chamfering machine have been analyzed though the experiment and the computer simulation. And the effects of the design parameters affecting the stability of the machine have been investigated to stabilize the machine structure and further to reduce structural vibrations. The result shows that design alterations to stabilize the machine can suppress the defects of the machined surface as well as the vibrations during chamfering.