• Title/Summary/Keyword: Computer mouse

Search Result 300, Processing Time 0.024 seconds

Technical Survey on the Real Time Eye-tracking Pointing Device as a Smart Medical Equipment (실시간 시선 추적기반 스마트 의료기기 고찰)

  • Park, Junghoon;Yim, Kangbin
    • Smart Media Journal
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 2021
  • The eye tracking system designed in this paper is an eye-based computer input device designed to give an easy access for those who are uncomfortable with Lou Gehrig's or various muscle-related diseases. It is an eye-based-computer-using device for users whose potential demand alone amounts to 30,000. Combining the number of Lou Gehrig's patients in Korea estimated at around 1,700, and those who are unable to move their bodies due to various accidents or diseases. Because these eye input devices are intended for a small group of users, many types of commercial devices are available on the market. It is making them more expensive and difficult to use for these potential users, less accessible. For this reason, each individual's economic situation and individual experience with smart devices are slightly different. Therefore, making it difficult to access them in terms of cost or usability to use a commercial eye tracking system. Accordingly, attempts to improve accessibility to IT devices through low-cost but easy-to-use technologies are essential. Thus, this paper proposes a complementary superior performance eye tracking system that can be conveniently used by far more people and patients by improving the deficiencies of the existing system. Through voluntary VoCs(Voice of Customers) of users who have used different kinds of eye tracking systems that satisfies it through various usability tests, and we propose a reduced system that the amount of calculation to 1/15th, and eye-gaze tracking error rate to 0.5~1 degree under.

Desirable Suggestions for Korean Geo-technology R&D through Analysis of the Global Grand Challenges and Moonshot Projects (글로벌 과학난제 도전연구프로젝트 분석을 통한 우리나라 지질자원기술에의 바람직한 제언)

  • Kim, Seong-Yong;Sung, Changmo
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.111-120
    • /
    • 2020
  • Remarkable scientific and technological achievements are mainly shown in the 'super-convergence' or 'convergence of convergence' among cross- disciplinary fields, and advanced countries are promoting the 'high-risk, high-return research' ecosystem. Google LLC is carrying out numerous new challenges in terms of a non-failure perspective. Innovative research by the US Defense Advanced Research Projects Agency (DARPA) has produced such breakthroughs as the Internet, GPS, semiconductors, the computer mouse, autonomous vehicles, and drones. China is pioneering a 'Moon Village' and planning the world's largest nuclear fusion energy and ultra-large particle accelerator project. Japan has also launched 'the moonshot technology development research system' to promote disruptive innovation. In Korea, the government is preparing a new research program to tackle the global scientific challenges. Therefore, it is necessary to determine the reasonable geoscientific challenges to be addressed and to conduct a preliminary study on these topics. For this purpose, it is necessary to conduct long-term creative research projects centered on young researchers, select outstanding principal investigators, extract innovative topics without prior research or reference, simplify research proposal procedures, innovate the selection solely based on key ideas, and evaluate results by collective intelligence in the form of conferences.

An Evaluation of Human Sensibility on Perceived Texture for Real Haptic Representation (사실적인 햅틱 표현을 위한 질감지각 감성 평가)

  • Kim, Seung-Chan;Kyung, Ki-Uk;Sohn, Jin-Hun;Kwon, Dong-Soo
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.10
    • /
    • pp.900-909
    • /
    • 2007
  • This paper describes an experiment on the evaluation of human sensibility by monitoring responses to changes In the frequency and amplitude of a tactile display system. Preliminary tasks were performed to obtain effective adjectives concerning texture perception. The number of collected adjectives was originally 33. This number of adjectives was reduced to 14 by a suitability survey that asked whether an adjective is suitable for expressing a texture feeling. Finally after performing a semantic similarity evaluation, the number of adjectives was further reduced to ten and these ten were used in the main experiment. In the main experiment, selected sandpaper types and 15 selected combinations of frequencies and amplitudes of a tactile display were utilized to quantitatively evaluate the ten adjectives using a bipolar seven-point scale. The data show that a relationship exists between the independent variables(frequency, amplitude, and grit site) and the dependent variable(perceived texture). That is, the change of frequency and amplitude is directly related to perceived roughness or essential elements of human tactile sensitivity found in the preliminary experiment.

Survey of Staphylococcus epidermidis Contamination on the Hands of Dental Hygienists and Equipment Surface of Dental Clinics (치과의료기관 의료장비 표면 및 치과위생사 손의 Staphylococcus epidermidis 오염도 조사)

  • Kim, Seol-Hee
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.472-480
    • /
    • 2017
  • The purpose of this study was to investigate Staphylococcus epidermidis contamination on hands of 20 dental hygienists and 140 equipment surface of 20 dental clinics in a local area, from July to August 2017. The degree of S. epidermidis contamination was measured using a hand plate and a rodac plate and then cultured at $35^{\circ}C$ for 24 hours. Based on hand plate criteria, hand contamination was classified into low, middle, and high groups. Analysis of the variance (ANOVA) of the contamination level of the hand parts of the group surface contamination level of the dental clinic equipment was descriptive statistics after clustering lock count. S. epidermidis contamination was moderate in 55% of the hands of dental hygienists. The area of contamination was 29.45 colony-forming units (CFU) on the palm, followed by the middle finger 7.8 CFU, ring finger 6.4 CFU, and thumb 6 CFU. Medical equipment surface contamination was showed that 3-way handle 4.45 CFU, computer mouse 3.37 CFU, mirror handle 1.60 CFU were higher than other areas. The group with high hand contamination had a high positive correlation with the S. epidermidis contamination of the hand. S. epidermidis contamination level was higher on hands than on the medical equipment surface contamination. Therefore, medical staff should recognize the importance of hand hygiene which should be practiced in the manner suggested by World Health Organization. In addition, the medical team needs to be responsible for performing infection control tasks, implementing infection management guidelines and providing systematic education on infectious disease management.

Development of an EEG Software for Two-Channel Cerebral Function Monitoring System (2채널 뇌기능 감시 시스템을 위한 뇌파 소프트웨어의 개발)

  • Kim, Dong-Jun;Yu, Seon-Guk;Kim, Seon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 1999
  • This paper describes an EEG(electroencephalogram) software for two-channel cerebral function monitoring system to detect the cerebral ischemia. In the software, two-channel bipolar analog EEG signals are digitized and from the signals various EEG parameters are extracted and displayed on a monitor in real-time. Digitized EEG signal is transformed by FFT(Fast Fourier transform) and represented as CSA(compressed spectral array) and DSA(density spectral array). Additional 5 parameters, such as alpha ratio, percent delta, spectral edge frequency, total power, and difference in total power, are estimated using the FFT spectra. All of these are effectively merged in a monitor and displayed in real-time. Through animal experiments and clinical trials on men, the software is modified and enhanced. Since the software provides raw EEG, CSA, DSA, simultaneously with additional 5 parameters in a monitor, it is possible to observe patients multilaterally. For easy comparison of patient's status, reference patterns of CSA, DSA can be captured and displayed on top of the monitor. And user can mark events of surgical operation and patient's conditions on the software, this allow him jump to the points of events directly, when reviewing the recorded EEG file afterwards. Other functions, such as forward/backward jump, gain control, file management are equipped and these are operated by simple mouse click. Clinical tests in a university hospital show that the software responds accurately according to the conditions of patients and medical doctors can use the software easily.

  • PDF

Measurement of Preference for coffee component using Time-Intensity curve (Time-Intensity curve를 이용한 커피성분의 선호도 측정)

  • 오지영;민병찬;정순철;민병운;김상균;김유나;신정상;김철중
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.401-406
    • /
    • 1999
  • 생활이 풍족해질수록 사람들은 음식이나 음료를 통하여 미각을 즐기는 경향이 강해지고 있다. 미각이 발달한 사람들은 다른 감각이 발달한 사람들보다 소비 욕구가 왕성하여 상품정보에 밝은 편이고 신제품에 대한 호기심도 많아 주요고객으로 환영받을 수 있는 가능성이 매우 높다. 이러한 점을 고려할 때 미각은 소비성향의 척도가 될 수 있으며, 이것이 상품개발에 중요한 지표가 될 가능성이 있다. 그러나 맛에 민감하다거나 둔감하다고 표현되는 개인의 미각물질에 대한 감도는 개인마다 일정치 않다. 이것은 미각물질에 따라 개인의 상대적인 역치의 고조나 미각 강도의 대소가 다르거나 감도가 다른 미각물질에 대한 수용구조에 개인차가 있기 때문이다. 이처럼 개인차가 있는 미각을 표준화된 방법으로 측정하는 것은 그리 쉬운 일이 아니다. 미각강도 측정을 위한 Time-Intensity curve는 1958년 음식물의 특성에 대해 관심을 가졌던 Nielson에 의해 개발되었는데 최근에 Takagi와 Asakura가 Time-Intensity curve분석과 기록을 위해 microcomputer를 이용한 방법을 개발하였다. 그들의 방범은 Time-Intensity curve를 모니터에 보여주고 data를 floppy discs에 기록하여 software로 분석하는 것이다. 본 연구는 이것을 좀더 편리하고 단순하게 만들기 위해 감각의 강도를 전기적 저항의 interface를 통하여 computer에 입력하는 대신에 mouse를 이용하여 입력하는 방법을 개발하였다. 새로이 개발된 Time-Intensity curve를 이용하여 커피성분 중 설탕과 프림의 농도에 변화를 주어 맛의 좋고 싫음의 미각강도를 측정하는 실험을 하였다. 그 결과 상품개발의 중요한 지표가 되는 미각의 강도를 측정할 수 있었고 이것은 향후 commercial한 상품의 개발에 유용한 지표가 될 것이라고 본다.시사한다. 본 연구에서는 한국 연구 조직에서 일하는 외국인 연구자들의 동기 및 성과에 영향을 미치는 많은 요인들을 확인할 수 있었다. 상관관계, 분산분석, 회귀분석 등을 통해 활용 성과에 미치는 영향 요인들을 도출하였다. 설문 분석을 통하여 동기 및 성과 사이에는 강한 상관관계가 존재하는 것을 확인할 수 있었으며 이는 전통적인 동기 이론들과 부합한다. 대부분의 변수가 동기 및 성과에 동시에 영향을 미치는 것으로 조사되었으며 그중에서도 조직 협력 문화, 외국인 연구자의 의사소통 및 협력성, 외국인 연구자의 연구 능력 관련 변수들 및 연구 프로젝트의 기술수명주기, 외국인 연구자의 기존 기술지식의 흡수 등이 가장 중요한 변수로 나타났다. 이는 우리가 주로 중국 및 러시아 과학자들을 활용하여 상업화하는 외국인 연구인력 활용 패턴과도 일치하는 결과이다. 즉 우호적인 조직문화를 가지고 있는 연구 조직에서, 이미 과학기술 지식을 많이 가지고 있고 연구 능력도 높은 외국인 과학기술자를, 한국에서 기술이 태동 또는 성장하고 있는 연구 분야에서 활용하는 것이 가장 성과가 좋다는 사실을 확인시켜 주고 있다. 국내에서 최초로 수행된 본 연구는 외국인 연구 인력의 활용 성과가 매우 높으며, 우리의 과학기술혁신시스템을 보완하는 유효한 수단으로써 외국인 연구 인력이 중요한 대안이 될 수 있음을 발견하였다. 외국인 연구 인력을 잘 활용하기 위하여 문제점 및 개선방안을 활용 환경, 연구 인력이 중요한 대안이 될 수 있음을 발견하였다. 외국인 연구 인력을 잘 활용하기 위하여 문제점 및 개선 방안을 활용 환경, 연구 인력관리. 인력 교류사업, 외국인 과학자 지원 창구 등으로 나누어서 정리하였다. 연구시설, 주거시설 등의 하드웨어적 환경에 대한 개선도 중요하지만 연구 인력의 관리 능력 제고, 인력 교류 사업의 개선, 정보 제공 등 소프트웨어적인 활용 능력을 제고하는데 정책적인 관심을 기

  • PDF

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

Inhalation of panaxadiol alleviates lung inflammation via inhibiting TNFA/TNFAR and IL7/IL7R signaling between macrophages and epithelial cells

  • Yifan Wang;Hao Wei;Zhen Song;Liqun Jiang;Mi Zhang;Xiao Lu;Wei Li;Yuqing Zhao;Lei Wu;Shuxian Li;Huijuan Shen;Qiang Shu;Yicheng Xie
    • Journal of Ginseng Research
    • /
    • v.48 no.1
    • /
    • pp.77-88
    • /
    • 2024
  • Background: Lung inflammation occurs in many lung diseases, but has limited effective therapeutics. Ginseng and its derivatives have anti-inflammatory effects, but their unstable physicochemical and metabolic properties hinder their application in the treatment. Panaxadiol (PD) is a stable saponin among ginsenosides. Inhalation administration may solve these issues, and the specific mechanism of action needs to be studied. Methods: A mouse model of lung inflammation induced by lipopolysaccharide (LPS), an in vitro macrophage inflammation model, and a coculture model of epithelial cells and macrophages were used to study the effects and mechanisms of inhalation delivery of PD. Pathology and molecular assessments were used to evaluate efficacy. Transcriptome sequencing was used to screen the mechanism and target. Finally, the efficacy and mechanism were verified in a human BALF cell model. Results: Inhaled PD reduced LPS-induced lung inflammation in mice in a dose-dependent manner, including inflammatory cell infiltration, lung tissue pathology, and inflammatory factor expression. Meanwhile, the dose of inhalation was much lower than that of intragastric administration under the same therapeutic effect, which may be related to its higher bioavailability and superior pharmacokinetic parameters. Using transcriptome analysis and verification by a coculture model of macrophage and epithelial cells, we found that PD may act by inhibiting TNFA/TNFAR and IL7/IL7R signaling to reduce macrophage inflammatory factor-induced epithelial apoptosis and promote proliferation. Conclusion: PD inhalation alleviates lung inflammation and pathology by inhibiting TNFA/TNFAR and IL7/IL7R signaling between macrophages and epithelial cells. PD may be a novel drug for the clinical treatment of lung inflammation.

An Iterative, Interactive and Unified Seismic Velocity Analysis (반복적 대화식 통합 탄성파 속도분석)

  • Suh Sayng-Yong;Chung Bu-Heung;Jang Seong-Hyung
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.1
    • /
    • pp.26-32
    • /
    • 1999
  • Among the various seismic data processing sequences, the velocity analysis is the most time consuming and man-hour intensive processing steps. For the production seismic data processing, a good velocity analysis tool as well as the high performance computer is required. The tool must give fast and accurate velocity analysis. There are two different approches in the velocity analysis, batch and interactive. In the batch processing, a velocity plot is made at every analysis point. Generally, the plot consisted of a semblance contour, super gather, and a stack pannel. The interpreter chooses the velocity function by analyzing the velocity plot. The technique is highly dependent on the interpreters skill and requires human efforts. As the high speed graphic workstations are becoming more popular, various interactive velocity analysis programs are developed. Although, the programs enabled faster picking of the velocity nodes using mouse, the main improvement of these programs is simply the replacement of the paper plot by the graphic screen. The velocity spectrum is highly sensitive to the presence of the noise, especially the coherent noise often found in the shallow region of the marine seismic data. For the accurate velocity analysis, these noise must be removed before the spectrum is computed. Also, the velocity analysis must be carried out by carefully choosing the location of the analysis point and accuarate computation of the spectrum. The analyzed velocity function must be verified by the mute and stack, and the sequence must be repeated most time. Therefore an iterative, interactive, and unified velocity analysis tool is highly required. An interactive velocity analysis program, xva(X-Window based Velocity Analysis) was invented. The program handles all processes required in the velocity analysis such as composing the super gather, computing the velocity spectrum, NMO correction, mute, and stack. Most of the parameter changes give the final stack via a few mouse clicks thereby enabling the iterative and interactive processing. A simple trace indexing scheme is introduced and a program to nike the index of the Geobit seismic disk file was invented. The index is used to reference the original input, i.e., CDP sort, directly A transformation techinique of the mute function between the T-X domain and NMOC domain is introduced and adopted to the program. The result of the transform is simliar to the remove-NMO technique in suppressing the shallow noise such as direct wave and refracted wave. However, it has two improvements, i.e., no interpolation error and very high speed computing time. By the introduction of the technique, the mute times can be easily designed from the NMOC domain and applied to the super gather in the T-X domain, thereby producing more accurate velocity spectrum interactively. The xva program consists of 28 files, 12,029 lines, 34,990 words and 304,073 characters. The program references Geobit utility libraries and can be installed under Geobit preinstalled environment. The program runs on X-Window/Motif environment. The program menu is designed according to the Motif style guide. A brief usage of the program has been discussed. The program allows fast and accurate seismic velocity analysis, which is necessary computing the AVO (Amplitude Versus Offset) based DHI (Direct Hydrocarn Indicator), and making the high quality seismic sections.

  • PDF

Natural Language Processing Model for Data Visualization Interaction in Chatbot Environment (챗봇 환경에서 데이터 시각화 인터랙션을 위한 자연어처리 모델)

  • Oh, Sang Heon;Hur, Su Jin;Kim, Sung-Hee
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.9 no.11
    • /
    • pp.281-290
    • /
    • 2020
  • With the spread of smartphones, services that want to use personalized data are increasing. In particular, healthcare-related services deal with a variety of data, and data visualization techniques are used to effectively show this. As data visualization techniques are used, interactions in visualization are also naturally emphasized. In the PC environment, since the interaction for data visualization is performed with a mouse, various filtering for data is provided. On the other hand, in the case of interaction in a mobile environment, the screen size is small and it is difficult to recognize whether or not the interaction is possible, so that only limited visualization provided by the app can be provided through a button touch method. In order to overcome the limitation of interaction in such a mobile environment, we intend to enable data visualization interactions through conversations with chatbots so that users can check individual data through various visualizations. To do this, it is necessary to convert the user's query into a query and retrieve the result data through the converted query in the database that is storing data periodically. There are many studies currently being done to convert natural language into queries, but research on converting user queries into queries based on visualization has not been done yet. Therefore, in this paper, we will focus on query generation in a situation where a data visualization technique has been determined in advance. Supported interactions are filtering on task x-axis values and comparison between two groups. The test scenario utilized data on the number of steps, and filtering for the x-axis period was shown as a bar graph, and a comparison between the two groups was shown as a line graph. In order to develop a natural language processing model that can receive requested information through visualization, about 15,800 training data were collected through a survey of 1,000 people. As a result of algorithm development and performance evaluation, about 89% accuracy in classification model and 99% accuracy in query generation model was obtained.