• Title/Summary/Keyword: Computer aided design-computer aided manufacturing system (CAD-CAM)

Search Result 82, Processing Time 0.022 seconds

Sinus floor elevation and implant-supported fixed dental prosthesis in the posterior area, with full-digital system: a case report (완전 디지털 시스템을 이용한 상악동 거상술 및 구치부 임플란트 고정성 보철 수복 증례)

  • Gang Soo Park;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.157-164
    • /
    • 2024
  • A variety of digital technologies are being used throughout the entire implant treatment process of diagnosis, surgery, impression, design, and fabrication of prostheses. In this case, using a digital surgical guide, sinus floor elevation was performed without complications, and the implants were placed in the planned position. After the healing period for osseointegration, CAD-CAM (Computer-aided design-Computer-aided manufacturing) customized abutments and provisional prostheses were delivered. While using the provisional prosthesis, occlusal change was observed. To transfer the intermaxillary relationship and abutment position that reflect occlusal change and axial displacement, double scanning and abutment-level digital impressions were taken. Abutment superimposition was used to capture the subgingival margin without gingival retraction. Then, the definitive prosthesis was designed and fabricated with digital system. We report a case applying digital system, to achieve the predictable result as well as the efficient treatment process from implant surgery to fabricating prosthesis in the posterior area.

Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

  • Song, Tae-Jin;Kwon, Taek-Ka;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • PURPOSE. Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs. MATERIALS AND METHODS. Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test. RESULTS. Mean marginal gaps of 3-unit FPDs were $60.46{\mu}m$ for the Everest group, $78.71{\mu}m$ for the Lava group, and $81.32{\mu}m$ for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05). CONCLUSION. The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.

A CAD/CAM-based strategy for concurrent endodontic and restorative treatment

  • Escobar, Patricia Maria;Kishen, Anil;Lopes, Fabiane Carneiro;Borges, Caroline Cristina;Kegler, Eugenio Gabriel;Sousa-Neto, Manoel Damiao
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.27.1-27.12
    • /
    • 2019
  • This case report describes a technique in which endodontic treatment and permanent indirect restoration were completed in the same clinical appointment with the aid of a computer-aided design/computer-aided manufacturing (CAD/CAM) system. Two patients were diagnosed with irreversible pulpitis of the mandibular first molar. After access preparation, root canals were located, irrigation was performed until bleeding ceased, and the coronal tooth structure was prepared for indirect restoration. Then, utilizing an interim 3-mm build-up of the endodontic access cavity, a hemi-arch digital scan was performed with an intraoral scanner. Subsequent to digital scanning, restoration design was performed simultaneously with the endodontic procedure. The root canals were shaped using the Race system under irrigation with 2.5% sodium hypochlorite followed by root canal filling. The pulp chamber was subsequently filled with a 3-mm-thick composite resin restoration mimicking the interim build-up previously utilized to facilitate block milling in the CAD/CAM system. Clinical try-in of the permanent onlay restoration was followed by acid etching, application of a 5th generation adhesive, and cementation of the indirect restoration. Once the restoration was cemented, rubber dam isolation was removed, followed by occlusal adjustment and polishing. After 2 years of follow-up, the restorations were esthetically and functionally satisfactory, without complications.

Full mouth rehabilitation of a patient using monolithic zirconia and dental CAD/CAM system: a case report (단일구조 수복용 지르코니아와 Dental CAD/CAM System을 이용한 전악 임플란트 고정성 보철 수복 증례)

  • Lee, Sang-Hoon;Yoon, Hyung-In;Yeo, In-Sung;Han, Jung-Suk;Kim, Sung-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.196-207
    • /
    • 2018
  • An accurate implant placement with ideal location is significant for long-term success of the implant. An exact evaluation of nearby anatomic structures such as quality of residual bone, an inferior alveolar bone and a maxillary sinus is required. For a prosthetic-driven treatment, planned surgery, precise prosthesis and communication with the patient are significant requisites especially for full-mouth rehabilitation. In this case, the patient with severe alveolar bone resorption had a CT guided surgery supported by CT data and the data from scanning diagnostic wax-up. Afterward, edentulous area was restored by full mouth implant-supported prosthesis by using monolithic zirconia and CAD/CAM technique. This paper reports the outcome of the procedure which was remarkable both esthetically and functionally.

A Method for Generation of Grinding Map based on Automatic Mold Measurement (금형 자동측정에 의한 사상맵 생성)

  • Jeoung, Nam-Yeoung;Cho, Jin-Hyung;Oh, Hyun-Seung;Lee, Sae-Jae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.248-255
    • /
    • 2018
  • Ensuring the quality of molds is one of the major issues in mass production. In general, securing the quality of the molds is achieved by repeating grinding and die spotting after machining the molds based on engineer's decision. However, this heuristic method is affected by the engineer's skill and working environment. Therefore, a lot of time and resources are needed in order to ensure quality. In this study, ensuring the quality of molds using grinding map which is generated using automatic measurement is proposed. An automatic measuring system based on CMM (Coordinate Measuring Machine) is developed for measuring the molds. This system generates the measurement path automatically using the 3D CAD model of products. CAD (ComputerAided-Design), CAM (Computer-Aided-Manufacturing), and CAQ (Computer-Aided-Quality) technology is integrated using DMIS (Dimensional Measuring Interface Standard) format in the automatic measuring system. After measuring the molds, a grinding map is generated using the gap between the CAD model and measured values of mold. The grinding map displays the machining tendency and the required amount of grinding with values on a 3D map. Therefore, the quality of molds can be ensured with exactness and quickness based on the grinding map. This study shows that integrating the planning, measuring, and analyzing based on computer technology can solve the problem of quality assurance of mold using the proposed method, therefore the productivity can be increased.

서초프로젝트A 오피스텔 현장의 SHOP DWG

  • Kim, Hyeon-Ung
    • 월간 기계설비
    • /
    • no.11 s.184
    • /
    • pp.57-71
    • /
    • 2005
  • SHOP DWG의 현주소 어디까지 왔는가? 설계에서 제조에 이르는 전 과정을 컴퓨터로 제어하고 관리하는 기술. 캐드(CAD)와 캠(CAM)은 각각 computer-aided design,computer-aided manufacturing의 약칭으로 컴퓨터보조설계와 컴퓨터보조생산을 뜻한다. CAD는 설계도면을 한 장씩 수작업으로 제도하지 않고 설계 데이터베이스의 정보를 CRT(cathode ray tube)에서 화상을 보고 합성하면서 설계하므로 작업을 최적화 할 수 있다. CAD로 설계된 설계도의 내용은 CAM을 통해 NC(수치제어)공작기계에 정확한 작업동작을 지시하게 되며, 작업관리∙가공∙조립∙검사 등의 제조과정을 컴퓨터로 관리하여 작업속도와 제품의 정밀성을 높이게 된다. 최근에는 건축현장의 2D system이 보편화되어 있지만 건축현장의 핵심이라고 할 수 있는 기계설비의 기계실, 또는 조립화 공법 등에는 3차원 CAD∙CAM시스템이 개발되어 입체형상을 화면에 3차원으로 재현할 수 있고, 대상물의 표면적∙부피∙무게∙강도 등의 물리적 성질도 자동 계산하여 최적상태에서 현장의 시공에 적용할 수 있게 되었다. 1960년대 초 미국에서 자동차 모델∙엔진, 항공기 부품 등 의 설계에 수작업의 한계를 느껴 개발되었으며, 한국에서는 70년대 중반에 도입되어 운용되고 있다. 이에 따라 프로그램 회사들은 다양한 방법 등을 SHOP DWG에 적용하여 판매경쟁이 치열하다. (주)우진아이엔에스는 급속한 산업경제의 변화와 무한경쟁시대에 보다 나은 기술개발 투자에도 노력을 기울여, 2000년 11월 용인공장, 생산라인을 천안으로 이전, 확장 하여 배관 및 닥트의 CAD-CAM SYSTEM, P.F.P공법, 기계실3D, 블럭화배관, 닥트자동화 시스템, 설계, 용접공정을 공장화시켰으며, 신 개발품인 S.C.D(SEMI-CON DUCT)를 신설하여 모든 건축물에 맞는 필수적인 제품을 생산함으로써 선택의 폭을 넓히고, 현장 시공능력 효율을 높이고 있다. 이번 호에서는 (주)우진아이엔에스가 95년 설계팀을 발족하여 제로시스템의 3D공법을 공장 및 현장의 SHOP DWG에 적용해왔고 최근에는“서초 프로젝트A”현장에 SHOP DWG의 최대 결집체인 3D활용의 조립화 공법을 적용하여 초고층 오피스텔현장을 시공한 사례를 게재한다. 우진아이엔에스는 30여년의 기술 축척을 바탕으로 최고의 기술력과 풍부한 경험을 통해 아셈무역센타, 타워팰리스1차, 3차 및 목동트라팰리스, 분당트리폴리스, 수원삼성전자 R4, 등 국내굴지의 초고층빌딩 시공을 근거로 초고층의 기본설계를 이해하고 SHOP DWG을 통해서 기계설비공사의 향후 나아갈 지표를 제시하고 있다.

  • PDF

Reconstruction of anterior guidance using duplication technique of CAD/CAM: a case report (CAD/CAM의 복제 기법을 이용한 전방 유도의 재현 증례)

  • Bae, Ji-Cheol;Kim, Won-Hee;Jeon, Yong-Chan;Jeong, Chang-Mo;Yoon, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.121-127
    • /
    • 2014
  • Comprehensive prosthetic treatment requires considerations from various points of view. The anterior guidance is important factor in prosthodontic treatment of anterior teeth. Lingual surface contour of anterior restoration is so critical that a small mistake of laboratory or clinical process can cause discomfort of patient and disharmony of entire dentition. There are no guidelines for lingual surface contour that fit all patients. Therefore the lingual surface of provisional restoration is most accurately described as a customized one. The dentist transfers the exact information of anterior guidance that has made through long term provisional restoration to the technician. This case introduce that the duplication technique of CAD/CAM system to reproduce the anterior guidance of provisional restoration. This method can improve satisfaction of both patient and dentist.

Machining for Outsole Mold of Shoes Using CAD/CAM (CAD/CAM을 이용한 구두창 금형 가공)

  • Park Yong-Bok;Yum Jeong-No;Hwang In-Keuk
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The outsole mold of the shoes has been manufactured using electro-discharge machining by graphite electrode or using casting etc. The study is concerned with the pattern design for the outsole of shoes by CAD, the modeling and the generation of NC data by CAM system and the machining by CNC machining center. The ball end mill and the engraving cutter is used as cutter and the cutting conditions are adjusted according to the shapes and sizes of the cutter and part in cutting. The method showed the possibility coping with the rapid change of shoes industry and proposed the possibility for higher productivity and quality on mold-manufacturing of shoes outsole.

Full mouth rehabilitation with implant-supported fixed prosthesis via dental CAD-CAM system (Dental CAD-CAM system을 통한 고정성 전악 임플란트 수복 증례)

  • Hong, Jeong-Min;Han, Jung-Suk;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.97-106
    • /
    • 2021
  • Dental implants should be placed at ideal sites for implant-supported restorations. For a patient with insufficient residual ridge, mouth preparation including surgical intervention can be indicated to establish a soft and hard tissue environment favorable for a definitive prosthesis. Prosthodontic design based on computer-guided surgery and computer-aided design-computer-aided manufacturing (CAD-CAM) provides a visual blueprint allowing a clinician to assess the necessity of such a surgical intervention beforehand. In this case, a definitive restoration was planned and made via a CAD-CAM system according to the patient's oral status before treatment, simulated surgical interventions and serial provisional restorations. Based on the planning, a guided template was made and the implants were installed with bone augmentation using the template. Customized abutments, the first and the second provisional restorations were designed and fabricated by CAD-CAM. The definitive restorations were digitally made following the shape of the second provisional prostheses, which were confirmed in the patient's mouth. The patient was satisfied with the masticatory, phonetic and aesthetic functions of these definitive prostheses.

An integrated process planning, die design and working system for blaking and bending of sheet metal product (박판제품의 블랭킹 및 굽힘 가공을 위한 통합적 공정 및 금형설계와 가공시스템)

  • Kim, J.H.;Choi, J.C.;Kim, C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1998.03a
    • /
    • pp.155-159
    • /
    • 1998
  • This paper describes a research work of developing a computer-aided design and manufacturing (CAD-CAM) of irregular shaped sheet metal product for blanking or piercing and bending operation. An approach to the system is based on the knowledge-based rules. Knowledge for the system is formulated form plasticity theories, experimental results and the empirical knowledge of field experts. This system has been written in AutoLIST on the AutoCAD and in customer tool kit on the SmartCAM with a personal computer and is composed of nine modules. the system is designed by considering several factors, such as material and thickness of product, complexities of blank geometry and punch profile, diameter and material of a wire, and availability of press. This system is capable of unfolding a formed sheet metal to give flat pattern and automatically account for the adjustment of bending allowances to match tooling requirements by checking dimensions and generating NC data automatically according to drawings of die-layout module. Results carried out in each module will provide efficiencies to the designer and the manufacture of blanking or piercing and bending die in this field.

  • PDF