• 제목/요약/키워드: Computed tomography scanner

검색결과 100건 처리시간 0.028초

안와 전산화단층촬영검사 시 수정체 선량감소 방법과 영상 평가 (Lens Dose Reduction Methods and Image Quality in Orbital Computed Tomography Scan)

  • 문세영;홍상우;서지숙;김영범;곽완신;이성영;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.343-351
    • /
    • 2020
  • This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.

Image Quality and Lesion Detectability of Lower-Dose Abdominopelvic CT Obtained Using Deep Learning Image Reconstruction

  • June Park;Jaeseung Shin;In Kyung Min;Heejin Bae;Yeo-Eun Kim;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • 제23권4호
    • /
    • pp.402-412
    • /
    • 2022
  • Objective: To evaluate the image quality and lesion detectability of lower-dose CT (LDCT) of the abdomen and pelvis obtained using a deep learning image reconstruction (DLIR) algorithm compared with those of standard-dose CT (SDCT) images. Materials and Methods: This retrospective study included 123 patients (mean age ± standard deviation, 63 ± 11 years; male:female, 70:53) who underwent contrast-enhanced abdominopelvic LDCT between May and August 2020 and had prior SDCT obtained using the same CT scanner within a year. LDCT images were reconstructed with hybrid iterative reconstruction (h-IR) and DLIR at medium and high strengths (DLIR-M and DLIR-H), while SDCT images were reconstructed with h-IR. For quantitative image quality analysis, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured in the liver, muscle, and aorta. Among the three different LDCT reconstruction algorithms, the one showing the smallest difference in quantitative parameters from those of SDCT images was selected for qualitative image quality analysis and lesion detectability evaluation. For qualitative analysis, overall image quality, image noise, image sharpness, image texture, and lesion conspicuity were graded using a 5-point scale by two radiologists. Observer performance in focal liver lesion detection was evaluated by comparing the jackknife free-response receiver operating characteristic figures-of-merit (FOM). Results: LDCT (35.1% dose reduction compared with SDCT) images obtained using DLIR-M showed similar quantitative measures to those of SDCT with h-IR images. All qualitative parameters of LDCT with DLIR-M images but image texture were similar to or significantly better than those of SDCT with h-IR images. The lesion detectability on LDCT with DLIR-M images was not significantly different from that of SDCT with h-IR images (reader-averaged FOM, 0.887 vs. 0.874, respectively; p = 0.581). Conclusion: Overall image quality and detectability of focal liver lesions is preserved in contrast-enhanced abdominopelvic LDCT obtained with DLIR-M relative to those in SDCT with h-IR.

종합병원 응급실내의 영상의학과 장비에서의 세균 오염에 관한 보건학적 융합 분석 (Analysis of Healthcare Convergence on Bacterial Contamination of Radiological Equipment in Emergency Rooms of General Hospitals)

  • 홍동희;박미순
    • 한국융합학회논문지
    • /
    • 제8권1호
    • /
    • pp.51-59
    • /
    • 2017
  • 본 연구는 종합병원 내 응급실에 설치된 CT 장비와 일반촬영장비에 대한 세균 오염도 검사를 실시하여 보건학적 융복합 감염관리에 대한 기초자료를 마련하고자 하였다. 연구는 2015년 12월 1일부터 12월 31일까지 수도권 3곳과 전라도 2곳, 충청도 2곳 등 총 7곳의 의료기관을 대상으로하였다. 영상의학과 응급실 내 CT장비의 검출된 표면 오염 균주는 Micrococcus species(4,5%), Stenotrophomonas maltophilia(9%), Enteococcus faecium(4.5%), Providencia stuartii(4.5), Gram negative bacilli(4.5%), 일반촬영장비에서 검출된 표면 오염 균주는 Providencia stuartii(11%), Klebsiella pneumonia(3.5%), Stenotrophomonas maltophilia(11%), Pantoea species(11%), Acinetobacter baumannii(3.5%), Micrococcus species(3.5%), Escherichia coli(3.5%), Enterobacter species(3.5%), Gram negative bacilli(11%) 로 병원 감염의 원인균으로 알려진 균주는 없었고, 특이성을 가진 균주 역시 없었지만 가장 많이 검출된 구역이 모두 환자와 밀접한 관련을 갖는 곳이므로 방사선사는 검사 전후 알코올 등으로 깨끗이 닦아내야 할 것이다.

Report of the AAPM Radiation Therapy Committee의 Task Group No.66에 의한 전산화 단층촬영 모의치료기의 정도 관리 (Quality assurance for computed-tomography simulator : Report of the AAPM Radiation Therapy Committee Task Group No.66)

  • 이윤석
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.41-43
    • /
    • 2005
  • 목적 : 자체 제작한 Q.A tool을 이용하여 AAPM Task Group Report No.66 에서 제시하는 CT simulator의 Q.A 항목을 확인하여 보다 안전하고 정확한 CT-simulation 과정을 확보하기 위해 효율적이고 편리성을 갖춘 정도관리 과정을 제시하고자 한다. 대상 및 방법 : 본원에 CT simulator의 Q.A tool을 제작하여 Report of the AAPM Task Group No.66에서 제시하는 wall laser system, patient table, CT scanner의 imaging plane의 isocenter간의 정렬을 일간 단위로 확인한다. 결과 : Report of the AAPM Task Group No.66에서 제시하고 있는 정도관리 항목의 확인으로 wall laser의 ${\pm}\;2mm$, table의 ${\pm}\;2mm$, imaging plane의 ${\pm}\;2mm$ 허용 오차 범위내의 측정치를 확인하였다. 결론 : 방사선 치료을 위한 CT-simulation 과정에서 기존의 진단 영역의 CT Q.A protocol로는 확인되지 않는 항목이 있는데, Report of the AAPM Task Group No.66에서 제시하고 있는 Q.A 항목을 확인하여 방사선 치료전용 CT-simulator 장비의 적절한 정도 관리를 기하여 안전하고 정확한 CT-simulation 과정을 보장받을 수 있었다.

  • PDF

안면부에 잔류된 다양한 이물질을 측정한 CT 계수 (CT Number Measurement of Residual Foreign Bodies in Face)

  • 위서영;최환준;김미선;최창용
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.423-430
    • /
    • 2008
  • Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성 (Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients)

  • 김진의;김정수;한재복;최남길
    • 한국콘텐츠학회논문지
    • /
    • 제16권3호
    • /
    • pp.219-231
    • /
    • 2016
  • 신장의 기능을 정량분석 할 수 있는 $^{99m}Tc$-DMSA 평면 영상은 단층영상에 비해 병소의 위치 정보에 한계가 있다. 따라서 광자 신호에 민감한 범용성 collimator로 교체하여 SPECT 방식으로 임상실험을 시행한 후, 진단의 정확도와 검사 소요시간을 분석하여 임상적용 가능성을 평가하였다. 10명의 실험대상에게 방사성의약품(1.0-1.2 MBq/kg)을 정맥주사하고, 이중 검출기 감마카메라를 이용하여 planar scan (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image)과 SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction)를 시행하였다. 획득한 데이터를 분석 프로그램을 이용하여 비교한 결과, 실험 방법에 따라서 total counts는 high sensitive-mode SPECT가 대략 1.8-5.6 배 정도 많았고, counts를 이용한 상대신장기능은 모든 실험에서 유의한 수준 범위에서 차이가 없었으며(p=0.96), 검사 소요시간은 39%정도 단축되었다. 그러므로 고감도 범용성 collimator를 이용한 $^{99m}Tc$-DMSA renal SPECT는 planar scan에 비하여 신장의 기능을 정량분석 할 수 있고, 병변의 위치에 대한 정보를 보다 정확하게 진단할 수 있으며, 동시에 검사 소요시간을 단축시킬 수 있으므로 임상적으로 유용하게 활용할 수 있을 것으로 사료된다.

전산화 단층 촬영 장치를 이용한 뇌척수 조사의 치료 계획 (Computed Tomographic Simulation of Craniospinal Irradiation)

  • 이충일;김회남;오택열;황도성;박남수;계철승;김연실
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.53-59
    • /
    • 1999
  • The aim of this study is to improve the accuracy of field placement and junction between adjacent fields and block shielding through the use of a computed tomography(CT) simulator and virtual simulation. The information was acquired by assessment of Alderson Rando phantom image using CT simulator (I.Q. Xtra - Picker), determination of each field by virtual fluoroscopy of voxel IQ workstation AcQsim and colored critical structures that were obtained by contouring in virtual simulation. And also using a coronal, sagittal and axial view can determine the field and adjacent field gap correctly without calculation during the procedure. With the treatment planning by using the Helax TMS 4.0, the dose in the junction among the adjacent fields and the spinal cord and cribriform plate of the critical structure was evaluated by the dose volume histogram. The pilot image of coronal and sagittal view took about 2minutes and 26minutes to get 100 images. Image translation to the virtual simulation workstation took about 6minutes. Contouring a critical structure such as cribriform plate, spinal cord using a virtual fluoroscopy were eligible to determine a correct field and shielding. The process took about 20 minutes. As the result of the Helax planning, the dose distribution in adjacent field junction was ideal, and the dose level shows almost 100 percentage in the dose volume histogram of the spinal cord and cribriform plate CT simulation can get a correct therapy area due to enhancement of critical structures such as spinal cord and cribriform plate. In addition, using a Spiral CT scanner can be saved a lot of time to plan a simulation therefore this function can reduce difficulties to keep the patient position without any movements to the patient, physician and radiotherapy technician.

  • PDF

관상동맥우회술 후 CT 조영술을 이용한 이식편의 조기 열림의 판정 (Determination of Early Graft Patency Using CT Angiography after Coronary Artery Bypass Surgery)

  • 이미경;류대웅;최순호;최종범
    • Journal of Chest Surgery
    • /
    • 제37권7호
    • /
    • pp.570-577
    • /
    • 2004
  • 관상동맥우회술 후 이식편의 조기 열림을 판정하기 위한 CT 조영술은 비침습적이고 간단하며 안전한 방법으로 알려져 있다. 저자들은 관상동백 우회술 환자들에서 수술 후 퇴원 전에 CT 조영술을 시행하여 이식편의 조기 열림의 판정에 대한 여부와 영상에 미치는 인자들을 조사하였다. 대상 및 방법: 관상동맥 우회술을 받은 50예에서 수술 후 퇴원 전에 4개의 검출기를 가진 CT기로 조영술을 시행하고 내흉동맥 이식편(50편), 요골동맥편(18편), 대퇴정맥편(56편)의 조영상해로 이식편의 열림을 조사하고 이식편의 조영상태와 문합혈관의 직경, 부행혈류 및 협착정도와의 관계를 분석하였다. 결과: 좌관상동맥계에 문합되는 정맥편(24편, 32문합부)은 모두 잘 조영되었으나, 우관상동백계에 문합된 정맥편(30편, 35문합부) 중 3편 (4.7%)은 CT 조영술에서 조영되지 않았고 대퇴동맥을 통한 침습적인 관상동맥 조영술에서도 폐쇄된 소견을 보였다. 내흉동맥편 중 39편(78%)은 CT 조영술에서 잘 조영되었고 8편(16%)은 일부 좁아지거나 끊기는 불완전한 조영을 보였으며 3편(6%)은 조영되지 않았으나 동맥을 통한 침습적인 관상동맥 조영술에서는 모두 정상적인 열림 소견을 보였다. 결론: 관상동맥조영술 후 CT 조영술에서 조영되지 않는 정맥편은 페쇄를 의미하나, CT조영술에서 조영되지 않는 동맥편은 폐쇄가 아닌 관상동맥과 이식편 사이의 상경혈류 때문에 일어날 수 있으므로 조영이 안 되는 동맥편의 열림을 확인하기 위해서는 침습적인 관상동맥조영술이 필요할 것으로 생각된다.

MDCT 장치의 z-축 기하학적 선량효율에 관한 연구 (Research of z-axis geometric dose efficiency in multi-detector computed tomography)

  • 김유현;김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.167-175
    • /
    • 2006
  • 최근의 나선형 CT와 MDCT는 기존의 고식적 CT보다 X-선 조사시의 겹침 현상과 영상 재구성에 있어서의 보간삽입처리로 인해 보다 높은 선량을 환자에게 주게 되었다. MDCT와 나선형 CT장치가 보다 많은 의학적 정보를 제공하는 것에도 불구하고 환자가 받는 방사선 노출은 기존의 고식적 CT검사에 비해 $2{\sim}4$배 정도로 증가되고 있는 실정이므로, 그 잠재적 위험성을 아무리 강조해도 지나침이 없다. CT장치에서의 보다 많은 X-선에 관련된 자료들, 특히 선량효율적 디자인이나 X-선 조절 소프트웨어에 대한 자료들이 필요하다. 왜냐하면 CT장치의 디자인 요소는 임상적 진단에 있어서 환자선량을 성공적으로 줄일 수 있는 중요한 요소이기 때문이다. 이에 본 연구에서는 최근 급격히 확산되어 사용되고 있는 여러 단계의 MDCT의 z-축 선량효율을 측정하여 SDCT와 비교하였다. 그리고 MDCT에서 스캔 시 채택하는 focal spot size와 beam collimation, 검출기 조합 등을 비롯한 파라메터들의 변화에 따른 z-축 선량효율을 파악하여 다음과 같은 결과를 얻었다. 1. SDCT가 z-축 기하학적 선량효율이 가장 높았고, 4 슬라이스 MDCT가 가장 낮았다. MDCT 중에서는 small beam collimation 적용 시 64 MDCT가 기하학적 선량효율이 가장 높았고 16, 8, 4 슬라이스 MDCT 순이었으며, large beam collimation 적용 시에는 small focal spot에서는 8 MDCT가, large focal spot에서는 16 MDCT가 가장 높았다. 2. MDCT의 경우 large focal spot에 비해 small focal spot의 z-축 기하학적 선량효율이 최저 0.67%에서 최대 13.62%의 범위에서 높았다. 3. MDCT의 경우 small beam collimation에 비해 large beam collimation의 z-축 기하학적 선량효율이 $3.13{\sim}51.52%$의 범위에서 높았다. 4. 동일한 focal spot size와 beam collimation을 채택한 상태에서 detector combination 차이에 따른 z-축 기하학적 선량효율은 4 슬라이스 MDCT의 모든 경우와 8 슬라이스 MDCT의 large beam collimation에서 일정하였다. 하지만 8 슬라이스 MDCT의 small beam collimation과 16 슬라이스 MDCT에서는 z-축 기하학적 선량효율이 차이를 보였으며 변화의 일률성은 없었다. 5. 동일한 스캔 파라메터를 적용시 나선형 스캔과 고식적 스캔 모드의 z-축 기하학적 선량효율은 동일하였으며, pitch를 변화시키거나 영상재구성 시 슬라이스 두께와 간격을 변화시켜도 z-축 기하학적 선량효율은 변화가 없었다. 결론적으로, CT검사 시 환자가 받는 X-선 피폭선량을 줄이기 위해 연구자는 CT장치의 선량효율에 대해 각별히 주의하여야 하며, Z-축 선량효율성을 높이는 동시에 최적의 임상적 정보를 보존할 수 있는 스캔 파라메터를 선택하여야 한다.

  • PDF

Large Pendulous Breast 환자의 방사선 치료에 있어서 엎드린 자세의 유용성 평가 (A Dosimetric Evaluation of Large Pendulous Breast Irradiation in Prone Position)

  • 홍채선;주상규;박주영
    • 대한방사선치료학회지
    • /
    • 제20권1호
    • /
    • pp.37-43
    • /
    • 2008
  • 목 적: 유방 보존 수술 후 방사선 치료를 받는 Large pendulous breast 환자에 있어서 엎드린 자세의 유용성을 평가해 보고자 한다. 대상 및 방법: 동일 환자에게 Breast board를 사용한 바로 누운 자세(Supine position: SP), Breast Supporting Device를 사용한 바로 누운 자세(Supine position with breast supporting device: SD), 그리고 Custom Prone mattress를 사용한 엎드린 자세 (Prone position: PP)를 모두 적용하였다. 각 방법에 대해 전산화단층촬영(High Advantage, GE Medical System, USA)을 시행하였고, 3차원 치료계획용 컴퓨터($Pinnacle^3$, Philips Medical System, USA)를 사용하여 세 방법에 대한 최적의 치료 계획을 세웠다. 평가를 위해 임상표적체적(CTV)과 조사되는 정상조직(동측 폐, 심장)의 용적(ILV, IHV)을 구하였고, 각 정상조직에 대해 Central Lung Distance (CLD)와 Maximum heart distance (MHD)를 측정하였다. 또한, 선량 체적 히스토그램(Dose-volume histogram, DVH)을 사용하여 CTV에서 $V_{95}$, $V_{100}$, $V_{105}$, $V_{110}$$D_{90}$, $D_{95}$를 비교하였고, 정상조직에 있어서 $D_5$$V_{20\;Gy}$ (동측 폐), $V_{18\;Gy}$ (심장)을 비교하였다. 결 과: SP와 SD에 비해 PP에서 ILV가 73.6%와 49.5%, IHV가 33.8%와 10.7%, CLD가 54.5%와 40.0%, 그리고 MHD에서 34.3% 와 20.7% 감소하였다. CTV의 선량 체적 히스토그램을 비교한 결과, SP에서 $V_{110}$이 0.2%인 것과 달리 PP에서 $V_{95}$가 96.2%, $V_{100}$이 61.5%, $V_{105}$가 1.2%, 그리고 $V_{110}$은 0%의 값을 나타내어 상대적으로 과다선량(hot spot) 영역 없이 Dose coverage가 우수함을 보여 주었다. 정상조직의 $D_5$는 동측 폐에 있어서 PP가 SP와 SD에 비해 57.6%와 52.2%, 심장에서는 13.9%와 11.4% 감소하였다. 또한, 동측 폐의 $V_{20\;Gy}$는 77.4%와 57.8%, 심장의 $V_{18\;Gy}$는 42.4%와 39.1% 감소하였다. 결 론: Large pendulous breast 환자의 방사선 치료 시, 엎드린 자세의 적용은 CTV의 선량 분포를 향상시키고, 동측 폐와 심장의 선량 감소를 가능케 한다.

  • PDF