• 제목/요약/키워드: Computed tomography imaging

검색결과 1,721건 처리시간 0.035초

안면부에 잔류된 다양한 이물질을 측정한 CT 계수 (CT Number Measurement of Residual Foreign Bodies in Face)

  • 위서영;최환준;김미선;최창용
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.423-430
    • /
    • 2008
  • Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

내경동맥 풍선 시험 결찰술(BTO)시 $^{99m}Tc$-HMPAO 뇌 SPECT를 이용한 대뇌 측부 순환의 평가 (Assessment of Cerebral Collateral Circulation Using $^{99m}Tc$-Hexamethyleneamine Oxime (HMPAO) SPECT During Internal Carotid Artery Balloon Test Occlusion)

  • 유영훈;윤미진;정태섭;이종두;박창윤
    • 대한핵의학회지
    • /
    • 제29권1호
    • /
    • pp.22-30
    • /
    • 1995
  • 저자들은 두개 기저나 경부종괴 또는 내경동맥의 동맥류등으로 인하여 내경동맥의 결찰이 필요한 환자에 있어서 객관적인 관점에서 수술전에 영구적인 내경동맥의 결찰의 안전성에 관하여 $^{99m}Tc$-HMPAO 뇌 SPECT를 이용하여 보고자 하였다. 내경동맥의 결찰이 고려되는 24명의 두개기저나 경부종괴 환자를 대상으로 하였다. 저자들은 풍선 시험 결찰술 시행전과 시행중의 양측 중대뇌동맥 영역의 섭취정도를 $^{99m}Tc$-HMPAO 뇌 SPECT를 이용하여 비교해보았고 이러한 결과를 신경학적 검사, 경동맥 스텀프압 고리고 뇌전도검사등과 비교해 보았다. 대상환자중 19명의 환자에서는 풍선 시험 결찰술 동안 신경학적 이상등의 문제들을 경험하지 않았고 이들에 있어 중대뇌동맥영역의 섭취정도는 결찰술 시행전에 비교하여 95-101%에 해당하였다. 나머지 5명의 환자에서는 일과성 반신마비와 의식소실등의 심한 신경학적 증상을 보였고 이들에 있어 중대뇌동맥 영역의 섭취정도는 시행전에 비하여 77-85%에 해당하였으며 다른 검사결과와도 잘 부합되었다. 결론적으로 풍선시험결찰술 시행전과 시행중의 $^{99m}Tc$-HMPAO 뇌 SPECT는 중대뇌동맥영역의 섭취가 시행전에 비교하여 85%이하인 경우 영구적인 신경학적 결손을 예측할 수 있는 간단하고 객관적인 방법이 될 수 있을 것으로 생각한다.

  • PDF

정신분열병 환자의 임상적 증세 호전에 따른 $^{99m}Tc$-HMPAO 뇌 SPECT 소견의 변화 (Effect of Clinical Improvement of Schizophrenic Symptoms on $^{99m}Tc$-HMPAO Brain SPECT)

  • 신철진;궁성수;정인원
    • 대한핵의학회지
    • /
    • 제31권3호
    • /
    • pp.310-319
    • /
    • 1997
  • 본 연구는 정신분열병 환자의 치료후의 국소뇌혈류량의 변화 및 증상호전과의 관계를 알아보기 위하여 시행되었다. DSM-IV 진단기준에 의거한 총 11명의 정신분열병 환자를 대상으로 치료전과 치료 6주째에 $^{99m}Tc$-HMPAO 뇌 SPECT를 실시하였으며 동시에 PANSS를 사용하여 정신병리를 함께 평가하였다. 대상자들은 입원전 최소 2주간의 항정신병 약물 비복용기간을 거친 환자들이었으며 이중 3명은 과거 항정신병약물의 복용력이 없는 사람들이었다. 6주간의 약물 치료훼 환자들은 증상의 호전 정도에 따라 호전군과 비호전군으로 나누어졌으며 이들간의 뇌국소혈류지수를 비교하였다. 결과적으로 전두엽의 혈류지수는 양집단 모두에서 감소하였고 집단간의 차이는 없었다. 그러나 조측 측두엽의 혈류량은 호전군에서 유의하게 많이 감소하였고 또한 우측 측두엽의 혈류량의 감소량은 PANSS 총점의 감소량과 상관관계를 나타내었다. 이러한 결과는 정신분열병의 증상과 측두엽의 활동성간의 관계를 시사하는 소견이라고 하겠다.

  • PDF

난치성 측두엽간질의 발작간 뇌혈류 SPECT, MRI와 수술성과 비교 (Interictal rCBF SPECT, MRI and Surgical Outcome of Intractable Temporal Lobe Epilepsy)

  • 전석길;주양구;이상도;손은익;이영환
    • 대한핵의학회지
    • /
    • 제28권3호
    • /
    • pp.307-312
    • /
    • 1994
  • Interictal single photon emission computed tomography of regional cerebral blood flow (rCBF SPECT) in 18 intractable temporal lobe epilepsy patients(8 male and 10 female patients: average 23.5 years old) were compared with 2.0 T magnetic resonance imaging (MRI). And surgical outcome was analysed with the findings, symptom duration and lateralization of temporal lobe. Preoperatively rCBF SPECT was done in all 18 patients with intravenous injection of 740 MBq 99mTc-HMPAO. MRI was also done preoperatively in 13 patients. Surgical outcome was classified by Engel's outcome classification(four-part classification recommended at the first Palm Desert conference). rCBF SPECT detected correctly lateralising abnormality of temporal lobe hypoperfusion in 13/18(72.2%), contralateral temporal lobe hypoperfusion in 2/18(11.1%) and showed no def-inite abnormality in 3/18(16.7%). The positive predictive value of unilateral temporal lobe hypoperfusion was 87%. MRI detected correct localising abnormality in 8/13(61.5%), such as hippocampal atrophy(7/13), asymmetric temporal horn(6/13), anterior temporal lobe atrophy(1/13), increased signal intensity from hippocampus(1/13) and calcific density(1/13), and no abnormal finding was noted in 5/13(38.5%). There was no false positive findings and the positive predictive value of MRI was 100%. Only 2 cases showed same lateralization findings in rCBF SPECT and MRI. There was no significant correlation between symptom duration and no abnormal findings on SPECT or MRI. Surgical outcome showed class I in 15/18(83.3%), and class II in 2/18(11.1%). One case of no abnormal finding in both SPECT and MRI showed class III surgical outcome. No class IV surgical outcome was noted. Surgical outcome, lateralization of epileptic focus in temporal lobe and abnormal findings in rCBR SPECT or MRI were not significantly correlated.

  • PDF

병렬 연산을 이용한 방출 단층 영상의 재구성 속도향상 기초연구 (Preliminary Study on the Enhancement of Reconstruction Speed for Emission Computed Tomography Using Parallel Processing)

  • 박민재;이재성;김수미;강지연;이동수;박광석
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권5호
    • /
    • pp.443-450
    • /
    • 2009
  • 목적: 기존의 영상 재구성은 간소화된 투사 물리 모델을 사용하고 있다. 하지만 3D 재구성과 같은 실제적인 물리 모델은 시간이 많이 걸려서 임상에서 모든 데이터에 적용하기 힘들고, 복잡한 물리모델을 설명하기 위해 큰 메모리를 사용하면 한대의 일반적인 재구성 머신으로는 불가능하다. 개인 컴퓨터들에서도 큰 규모의 기술을 가능하게 하기위해, 병렬 연산을 이용한 빠른 재구성의 현실적인 분산메모리 모델을 제시한다. 대상 및 방법: 실제로 구현하는 가능성을 보기 위해 가상 컴퓨터들을 이용하여 선행 연구를 진행하였고, 다양한 가능성을 테스트하기 위해 상용서비스를 하고 있는 슈퍼컴퓨터(Tachyon)에서 성능 테스트를 하였다. 가장 많이 사용되는 2D 투사 영상과 실제적인 물리 모델인 3D 응답라인을 이용한 기댓값 최대화 알고리즘을 테스트하였다. 스터디 중 특정 반복횟수 이후에 속도가 최대 6배까지 느려지는 현상이 발견되어 컴파일러 최적화를 통해 병렬 효율의 극대화를 꾀하였다. 결과: Linux에서 MPICH와 NFS를 이용하여, 여러 컴퓨터에서 하나의 프로그램으로 분산 연산이 가능하였다. 병렬 연산을 했을 때 동일한 반복 연산에서 재구성된 영상간의 차이가 실수의 유효숫자(6bit) 정도임을 확인하였다. 2배의 연상장치를 사용했을 때 1.96배의 좋은 병렬화 효율을 보여주었다. 반복 연산 횟수가 증가함에 따라 느려지는 현상은 SSE를 이용한 Vectorization 방법을 사용했을 때 해결할 수 있었다. 결론: 이번 연구를 통해 일반 컴퓨터들을 이용한 현실적인 병렬 컴퓨터 시스템을 구성하여, 작은 메모리의 단일 일반 컴퓨터로는 불가능한 간단화 할 수 없는 복잡한 물리 과정도 영상 재구성 방법에 사용 가능하게 되었다.

Outcomes and Patency of Complex Configurations of Composite Grafts Using Bilateral Internal Thoracic Arteries

  • Shih, Beatrice Chia-Hui;Chung, Suryeun;Kim, Hakju;Chang, Hyoung Woo;Kim, Dong Jung;Lim, Cheong;Park, Kay-Hyun;Kim, Jun Sung
    • Journal of Chest Surgery
    • /
    • 제53권2호
    • /
    • pp.64-72
    • /
    • 2020
  • Background: It is generally agreed that using a bilateral internal thoracic artery (BITA) composite graft improves long-term survival after coronary artery bypass grafting (CABG). Although the left internal thoracic artery (LITA)-based Y-composite graft is widely adopted, technical or anatomical difficulties necessitate complex configurations. We aimed to investigate whether BITA configuration impacts survival or patency in patients undergoing coronary revascularization. Methods: Between January 2006 and June 2017, 1,161 patients underwent CABG at Seoul National University Bundang Hospital, where the standard technique is a LITA-based Y-composite graft with the right internal thoracic artery (RITA) sequentially anastomosed to non-left anterior descending (LAD) targets. Total of 160 patients underwent CABG using BITA with modifications. Their medical records and imaging data were reviewed retrospectively to investigate technical details, clinical outcomes, and graft patency. Results: Modifications of the typical Y-graft (group 1, n=90), LITA-based I-graft (group 2, n=39), and RITA-based composite graft (group 3, n=31) were used due to insufficient RITA length (47%), problems using LITA (28%), and target vessel anatomy (25%). The overall 30-day mortality rate was 1.9%. Among 116 patients who underwent computed tomography or conventional angiography at a mean interval of 29.9±33.1 months postoperatively, the graft patency rates were 98.7%, 95.3%, and 83.6% for the LAD, left circumflex artery, and right coronary artery territories, respectively. Patency rates for the inflow, secondary, and tertiary grafts were 98.2%, 90.5%, and 80.4%, respectively. The RITA-based graft (group 3) had the lowest patency rate of the various configurations (p<0.011). Conclusion: LITA-based Y composite graft, showed satisfactory clinical outcomes and patency whereas modifications of RITA- based composite graft had the lowest patency and 5-year survival rates. Therefore, when using RITA-based composite graft, other options should be considered before proceeding atypical configurations.

제 1형 신경 섬유종증 환자에서 발생한 재발성 견관절 탈구 및 근위 상완골 골절 - 1예 보고 - (Recurrent Shoulder Dislocation and Proximal Humerus Fracture in Neurofibromatosis Type I - A Case Report -)

  • 황태혁;조형래;왕태현;양희순
    • Clinics in Shoulder and Elbow
    • /
    • 제16권2호
    • /
    • pp.135-140
    • /
    • 2013
  • 제 1형 신경 섬유종증 환자에서 발생한 재발성 견관절 탈구 및 동반된 근위 상완골 골절 1예를 보고하고자 한다. 제 1형 신경 섬유종증으로 진단된 20세 남자로 가벼운 외상 후 발생한 우측 견관절의 탈구와 근위 상완골 골절로 내원하였다. 수상측 주관절부에는 큰 망상형 신경 섬유종들이 있었으며 견관절 탈구는 재발성 병변이었다. 단순 방사선과 컴퓨터 단층 촬영 소견 상 상완골과 견갑골의 골성 변형을 보였고 자기 공명 영상 검사 상 삼각근과 회전근 개에 다발성 신경 섬유종성 변화가 관찰되었다. 관혈적 정복술 및 관절막 재건술을 시행하였으며 근위 상완골 골절은 재건 금속판을 이용하여 고정하였다. 골유합과 만족스런 기능 회복을 보였으며 수술 후 7개월 추시 상 견관절 탈구의 재발은 관찰되지 않았다. 제 1형 신경 섬유종증 환자에서 발생한 견관절 재발성 탈구와 근위 상완골 골절은 드문 합병증이나 질환의 정형외과적 접근 시 고려해야 할 것으로 사료된다.

소아 요막관 기형 (Urachal Anomalies in Children)

  • 강은영;이철구;박관현;서정민;이석구
    • Advances in pediatric surgery
    • /
    • 제11권2호
    • /
    • pp.150-156
    • /
    • 2005
  • Failure of the urachus to regress completely results in anomalies that may be classified as patent urachus, urachal sinus, urachal cyst and bladder diverticula. The presenting symptoms of children with urachal anomalies are variable and uniform guidelines for diagnosis and treatment are lacking. The purpose of this study was to analyze our experience and develop conclusions regarding the presentation, diagnosis and treatment of urachal anomalies. We retrospectively analyzed the records of 32 patients who were admitted for urachal anomalies from March 1995 to February 2005. The age distribution of these patients at presentation ranged from 1 day to 14 years old (median age 1 month). There were 20 boys and 12 girls. The 32 cases comprised 13 cases of urachal sinus (40.6 %), 10 urachal cyst (31.3 %), and 9 patent urchus (28.1 %). In 30 patients ultrasonography was used for diagnosis and 2 patients with patent urachus were explored without using a diagnostic method. Twenty-three patients were confirmed by ultrasonography alone and 7 patients were examined using additional modalities, namely, computed tomography for 2 patients with an urachal cyst, magnetic resonance imaging for 1 patient with an urachal cyst, and fistulography for 3 patients with an urachal sinus. The presenting symptoms were umbilical discharge (14 patients), umbilical granuloma (8), abdominal pain and fever (3), fever (3), abdominal pain (2), and a low abdominal mass (2). Excision was performed in 29 patients, and 3 patients were conservatively managed. Urachal anomalies in children most frequently presented in neonates, and the most common complaint was umbilical discharge with infection. Urachal anomalies can be diagnosed by a physical examination and an appropriate radiographic test. Ultrasound was the most useful diagnostic method. Complete surgical excision of an urachal anomaly is recommended to avoid recurrence, and the rare development of carcinoma.

  • PDF

상악구개측 미니스크류 식립위치 및 조건 (Miniscrew Installation Area and Condition on Maxillary Palatal Side)

  • 이기연;이진우
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.61-71
    • /
    • 2009
  • 교정치료에 있어서 고정원의 확보는 매우 중요한 문제이며 최대고정원을 얻기 위해서 미니스크류를 널리 이용하고 있다. 인접구조물을 손상시키지 않고 안전하게 미니스크류를 식립하기 위해서는 치근이나 상악동, 절치관, 비강, 대구개신경 등의 구조물의 해부학적 위치를 이해하면서 식립하는 것이 매우 중요하다. 미니스크류의 안정성의 관점에서 보면 상악골은 하악골에 비하여 골질이 단단하지 않고 탈락율이 높으며, 특히 협측골은 치근사이의 거리가 가깝고, 안정성이 높지 않다. 따라서 좀더 강한 고정원의 확보를 위하여 시술의 접근성이나 시야확보는 불리하지만 충분한 골 두께를 가지고 있는 상악구치부 구개측 치조부와 단단한 골을 가지고 있는 정중구개부위가 미니스크류 식립부위로 주목을 받고 있다. 이에 본 연구는 전산화 단층촬영 사진을 이용하여 3차원 영상프로그램을 이용하여 상악 구개측 치근 사이의 거리와 정중 구개봉합부위의 골의 두께를 계측하여 통계 분석하였으며 다음과 같은 결과를 얻었다. 1. 구개측 치근사이의 거리의 비교시 제2소구치와 제1대구치 사이, 제1대구치와 제2대구치 사이, 제1소구치와 제2소구치 사이의 순서로 유의하게 큰 치근 사이의 거리를 보였다. 2. 정중 구개부 골은 후방부위와 측방으로 갈수록 그 두께가 감소하였다. 이상의 결과로 구개측 치근 사이는 소구치와 대구치 사이가 상대적으로 안전한 부위이며 정중구개부에서는 봉합부위에 가까울수록 안전하게 미니스크류를 식립할 수 있을 것으로 생각된다.

유골골종의 경피적 고주파 열 치료 (Percutaneous Radiofrequency ablation for the Treatment of Osteoid osteoma)

  • 서재곤;정광훈;양일순
    • 대한골관절종양학회지
    • /
    • 제8권3호
    • /
    • pp.83-89
    • /
    • 2002
  • 목적: 유골골종의 진단 후 경피적 고주파 열 치료를 시행한 환자에서 수술 후 기능적 결과 및 방사선학적인 추시 결과를 분석하고자 하였다. 대상 및 방법: 본 연구는 1999년 7월부터 2001년 1월 사이에 임상소견 및 방사선 소견상 유골골종으로 진단 받고 저자들이 경피적 고주파 열 치료를 시행한 7명의 환자를 대상으로 하였으며 추시 기간은 최소 8개월에서 최장 2년 1개월로 평균 15.5개월이었다. 술 전 방사선학적 검사로는 단순방사선촬영, 전산화단층촬영, 자기공명영상이 진단 및 병소의 정확한 위치파악을 위하여 이용되었으며 술 후에는 정기적인 단순방사선 사진 및 자기공명영상으로 추적관찰 하였다. 결과: 술 후 환자의 증상 소실은 7례의 환자에서 3일 이내에 완전 소실이 이루어 졌으며 평균 입원 기간은 1례의 화상이 발생한 환자를 제외하고는 평균 2.4일 이었고 퇴원의 기준은 환자의 동통이 완전 소실된 이후로 하였다. 술 후 야간통 및 주간통 점수는 각각 평균 1.8점과 1.3점으로 이었다. 직업 활동 및 여가 활동의 점수도 각각 평균 1점과 0.6점이었다. 결론: 유골골종에 대하여 경피적 고주파 열 치료로 비교적 만족할 만한 기능적 결과를 얻었다. 이 시술은 기존의 고식적 방법으로 인한 입원기간의 증가, 술 후 골절 방지를 위한 내고정술 및 뼈 이식의 필요, 그리고 장기간의 고정으로 인한 관절운동의 장애 등의 합병증 없이 유골골종의 제거에 효과적인 방법으로 사료된다.

  • PDF