• Title/Summary/Keyword: Computed tomography imaging

Search Result 1,779, Processing Time 0.021 seconds

Chest Radiographs and CT Findings during Healthcare Workers' Tuberculosis Screening Using Interferon- Gamma Release Assay: Retrospective Observational Study (인터페론-감마 분비 검사를 이용한 의료 종사자의 결핵 스크리닝에서 흉부 X선 사진 및 CT 소견: 후향적 관찰 연구)

  • Ye Ra Choi;Jung-Kyu Lee;Eun Young Heo;Deog Kyeom Kim;Kwang Nam Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1524-1533
    • /
    • 2021
  • Purpose To investigate the incidence of tuberculosis (TB) in healthcare workers (HCWs) with positive interferon-gamma release assay (IGRA) results based on chest X-ray (CXR) and CT findings and determine the role of imaging in the diagnosis of TB. Materials and Methods Among 1976 hospital personnel screened for TB using IGRA, IGRApositive subjects were retrospectively investigated. Clustered nodular and/or linear streaky opacities in the upper lung zone were considered positive on CXR. The CT findings were classified as active, indeterminate, inactive, or normal. The active or indeterminate class was considered CT-positive. Results IGRA was positive in 255 subjects (12.9%). CXR and CT were performed in 249 (99.2%) and 113 subjects (45.0%), respectively. CXR- and CT-positive findings were found in 7 of 249 (2.8%) and 9 of 113 (8.0%) patients, respectively. Among the nine CT-positive subjects, active and indeterminate TB findings were found in 6 (5.3%) and 3 (2.7%) patients, respectively. Microbiological tests, including acid-fast bacilli staining, culture, and polymerase chain reaction for TB, were negative in all nine CT-positive subjects. Empirical anti-TB medications were administered to 9 CT-positive subjects, and 3 of these nine subjects were CXR-negative for pulmonary TB.

Feasibility of Single-Shot Whole Thoracic Time-Resolved MR Angiography to Evaluate Patients with Multiple Pulmonary Arteriovenous Malformations

  • Jihoon Hong;Sang Yub Lee;Jae-Kwang Lim;Jongmin Lee;Jongmin Park;Jung Guen Cha;Hui Joong Lee;Donghyeon Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.8
    • /
    • pp.794-802
    • /
    • 2022
  • Objective: To evaluate the feasibility of single-shot whole thoracic time-resolved MR angiography (TR-MRA) to identify the feeding arteries of pulmonary arteriovenous malformations (PAVMs) and reperfusion of the lesion after embolization in patients with multiple PAVMs. Materials and Methods: Nine patients (8 females and 1 male; age range, 23-65 years) with a total of 62 PAVMs who underwent percutaneous embolization for multiple PAVMs and were subsequently followed up using TR-MRA and CT obtained within 6 months from each other were retrospectively reviewed. All imaging analyses were performed by two independent readers blinded to clinical information. The visibility of the feeding arteries on maximum intensity projection (MIP) reconstruction and multiplanar reconstruction (MPR) TR-MRA images was evaluated by comparing them to CT as a reference. The accuracy of TR-MRA for diagnosing reperfusion of the PAVM after embolization was assessed in a subgroup with angiographic confirmation. The reliability between the readers in interpreting the TR-MRA results was analyzed using kappa (κ) statistics. Results: Feeding arteries were visible on the original MIP images of TR-MRA in 82.3% (51/62) and 85.5% (53/62) of readers 1 and 2, respectively. Using the MPR, the rates increased to 93.5% (58/62) and 95.2% (59/62), respectively (κ = 0.760 and 0.792, respectively). Factors for invisibility were the course of feeding arteries in the anteroposterior plane, proximity to large enhancing vessels, adjacency to the chest wall, pulsation of the heart, and small feeding arteries. Thirty-seven PAVMs in five patients had angiographic confirmation of reperfusion status after embolization (32 occlusions and 5 reperfusions). TR-MRA showed 100% (5/5) sensitivity and 100% (32/32, including three cases in which the feeding arteries were not visible on TR-MRA) specificity for both readers. Conclusion: Single-shot whole thoracic TR-MRA with MPR showed good visibility of the feeding arteries of PAVMs and high accuracy in diagnosing reperfusion after embolization. Single-shot whole thoracic TR-MRA may be a feasible method for the follow-up of patients with multiple PAVMs.

Appendiceal Visualization on 2-mSv CT vs. Conventional-Dose CT in Adolescents and Young Adults with Suspected Appendicitis: An Analysis of Large Pragmatic Randomized Trial Data

  • Jungheum Cho;Youngjune Kim;Seungjae Lee;Hooney Daniel Min;Yousun Ko;Choong Guen Chee;Hae Young Kim;Ji Hoon Park;Kyoung Ho Lee;LOCAT Group
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.413-425
    • /
    • 2022
  • Objective: We compared appendiceal visualization on 2-mSv CT vs. conventional-dose CT (median 7 mSv) in adolescents and young adults and analyzed the undesirable clinical and diagnostic outcomes that followed appendiceal nonvisualization. Materials and Methods: A total of 3074 patients aged 15-44 years (mean ± standard deviation, 28 ± 9 years; 1672 female) from 20 hospitals were randomized to the 2-mSv CT or conventional-dose CT group (1535 vs. 1539) from December 2013 through August 2016. A total of 161 radiologists from 20 institutions prospectively rated appendiceal visualization (grade 0, not identified; grade 1, unsure or partly visualized; and grade 2, clearly and entirely visualized) and the presence of appendicitis in these patients. The final diagnosis was based on CT imaging and surgical, pathologic, and clinical findings. We analyzed undesirable clinical or diagnostic outcomes, such as negative appendectomy, perforated appendicitis, more extensive than simple appendectomy, delay in patient management, or incorrect CT diagnosis, which followed appendiceal nonvisualization (defined as grade 0 or 1) and compared the outcomes between the two groups. Results: In the 2-mSv CT and conventional-dose CT groups, appendiceal visualization was rated as grade 0 in 41 (2.7%) and 18 (1.2%) patients, respectively; grade 1 in 181 (11.8%) and 81 (5.3%) patients, respectively; and grade 2 in 1304 (85.0%) and 1421 (92.3%) patients, respectively (p < 0.001). Overall, undesirable outcomes were rare in both groups. Compared to the conventional-dose CT group, the 2-mSv CT group had slightly higher rates of perforated appendicitis (1.1% [17] vs. 0.5% [7], p = 0.06) and false-negative diagnoses (0.4% [6] vs. 0.0% [0], p = 0.01) following appendiceal nonvisualization. Otherwise, these two groups were comparable. Conclusion: The use of 2-mSv CT instead of conventional-dose CT impairs appendiceal visualization in more patients. However, appendiceal nonvisualization on 2-mSv CT rarely leads to undesirable clinical or diagnostic outcomes.

Diagnostic Performance of Rectal CT for Staging Rectal Cancer: Comparison with Rectal MRI and Histopathology (직장암 병기결정에서 직장 CT의 진단능: 직장 MRI 및 병리결과와의 비교분석)

  • Seok Yoon Son;Yun Seok Seo;Jeong Hee Yoon;Bo Yun Hur;Jae Seok Bae;Se Hyung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1290-1308
    • /
    • 2023
  • Purpose To compare the diagnostic performance of rectal CT with that of high-resolution rectal MRI and histopathology in assessing rectal cancer. Materials and Methods Sixty-seven patients with rectal cancer who underwent rectal CT with rectal distension using sonographic gel and high-resolution MRI were enrolled in this study. The distance from the anal verge/anorectal junction, distance to the mesorectal fascia (MRF), extramural depth (EMD), extramesorectal lymph node (LN) involvement, extramural venous invasion (EMVI), and T/N stages in rectal CT/MRI were analyzed by two gastrointestinal radiologists. The CT findings of 20 patients who underwent radical surgery without concurrent chemoradiotherapy were compared using histopathology. Interclass correlations and kappa statistics were used. Results The distance from the anal verge/anorectal junction showed an excellent intraclass correlation between CT and MRI for both reviewers. For EMD, the distance to the MRF, presence of LNs, extramesorectal LN metastasis, EMVI, T stage, and intermodality kappa or weighted kappa values between CT and MRI showed excellent agreement. Among the 20 patients who underwent radical surgery, T staging, circumferential resection margin involvement, EMVI, and LN metastasis on rectal CT showed acceptable concordance rates with histopathology. Conclusion Dedicated rectal CT may be on par with rectal MRI in providing critical information to patients with rectal cancer.

Diagnostic Performance of Cardiac CT and Transthoracic Echocardiography for Detection of Surgically Confirmed Bicuspid Aortic Valve: Effect of Calcium Extent and Valve Subtypes (외과적으로 확진된 이첨 대동맥 판막의 진단을 위한 심장 CT 및 경흉부 심초음파의 진단적 성능: 판막 아형 및 칼슘의 양이 미치는 효과)

  • Jeongju Kim;Sung Mok Kim;Joonghyun Ahn;Jihoon Kim;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1324-1336
    • /
    • 2023
  • Purpose This study aimed to compare the diagnostic performance of cardiac CT and transthoracic echocardiogram (TTE) depending on the degree of valvular calcification and bicuspid aortic valve (BAV) subtype. Materials and Methods This retrospective study included 266 consecutive patients (106 with BAV and 160 with tricuspid aortic valve) who underwent cardiac CT and TTE before aortic valve replacement. Cardiac CT was used to evaluate the morphology of the aortic valve, and a calcium scoring scan was used to quantify valve calcium. The aortic valves were classified into fused and two-sinus types. The diagnostic accuracy of cardiac CT and TTE was calculated using a reference standard for intraoperative inspection. Results CT demonstrated significantly higher sensitivity, negative predictive value, and accuracy than TTE in detecting BAV (p < 0.001, p < 0.001, and p = 0.003, respectively). The TTE sensitivity tended to decrease as valvular calcification increased. The error rate of TTE for CT was 10.9% for the twosinus type of BAV and 28.3% for the fused type (p = 0.044). Conclusion Cardiac CT had a higher diagnostic performance in detecting BAV than TTE and may help diagnose BAV, particularly in patients with severe valvular calcification.

Papillary Renal Cell Carcinoma in Transplanted Kidney and Xp11.2 Translocation/Transcription Factor E3-Rearranged Renal Cell Carcinoma in the Native Kidney: A Case Report (이식신장에 생긴 유두모양 신세포암종과 고유신장에 생긴 Xp11.2전위/전사인자E3-재배열 신세포암종: 증례 보고)

  • Min Hye Kim;Kyeong Ah Kim;Jeong Woo Kim;Seok Young Lee;Jae Woong Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.437-444
    • /
    • 2024
  • Concomitant renal cell carcinomas (RCC) of both native and allograft kidneys are extremely rare, and only a few cases have been reported in the available English literature. A particularly rare variant within the adult population is the Xp11.2 translocation/transcription factor E3 (TFE3)-rearranged RCC. Although few case reports of TFE3-rearranged RCC have been reported in children who underwent kidney transplantation (KT), no case of adults with TFE3-rearranged RCC following KT has been reported. Herein, we presented the radiological and pathological findings of a rare metachronous papillary RCC in the allograft kidney and TFE3-rearranged RCC in the native kidney. The TFE3-rearranged RCC in the native kidney exhibited slow expansion in size over five years. Radiologically, it appeared as a slightly enhanced, lobulated mass on contrast-enhanced CT. MRI revealed high signal intensity on T1-weighted images and low signal intensity on T2-weighted images.

Gastric Metastasis from Gastric-Type Mucinous Adenocarcinoma of Uterine Cervix: A Case Report (자궁경부 위형 점액샘암종의 위 전이: 증례 보고)

  • Min Hye Kim;Kyeong Ah Kim;Yi Kyeong Chun;Jeong Woo Kim;Jongmee Lee;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.445-450
    • /
    • 2024
  • Gastric metastasis (GM) from cervical cancer is extremely rare, and only a few cases have been reported in the English literature. Gastric-type mucinous adenocarcinomas (GAS) of the uterine cervix are rare. GAS is an aggressive cancer commonly found in advanced stages; however, GM has not been reported. This study presents a rare case of GM from GAS of the uterine cervix in a 61-year-old female and describes the radiological findings of both the GM and cervical mucinous adenocarcinoma. GM appeared as a poor enhancing submucosal mass. The cervical mucinous adenocarcinoma appeared as an infiltrating mass with poor contrast enhancement. It exhibited mildly high and low signal intensities on the diffusion-weighted image and apparent diffusion coefficient map, respectively. This case is extremely rare and challenging to diagnose; however, if cervical cancer is an human papillomavirus-independent GAS type and a submucosal lesion is found in the stomach, the possibility of metastasis with a pattern similar to our case could be considered.

Predictions of PD-L1 Expression Based on CT Imaging Features in Lung Squamous Cell Carcinoma (편평세포폐암에서 CT 영상 소견을 이용한 PD-L1 발현 예측)

  • Seong Hee Yeo;Hyun Jung Yoon;Injoong Kim;Yeo Jin Kim;Young Lee;Yoon Ki Cha;So Hyeon Bak
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.394-408
    • /
    • 2024
  • Purpose To develop models to predict programmed death ligand 1 (PD-L1) expression in pulmonary squamous cell carcinoma (SCC) using CT. Materials and Methods A total of 97 patients diagnosed with SCC who underwent PD-L1 expression assay were included in this study. We performed a CT analysis of the tumors using pretreatment CT images. Multiple logistic regression models were constructed to predict PD-L1 positivity in the total patient group and in the 40 advanced-stage (≥ stage IIIB) patients. The area under the receiver operating characteristic curve (AUC) was calculated for each model. Results For the total patient group, the AUC of the 'total significant features model' (tumor stage, tumor size, pleural nodularity, and lung metastasis) was 0.652, and that of the 'selected feature model' (pleural nodularity) was 0.556. For advanced-stage patients, the AUC of the 'selected feature model' (tumor size, pleural nodularity, pulmonary oligometastases, and absence of interstitial lung disease) was 0.897. Among these factors, pleural nodularity and pulmonary oligometastases had the highest odds ratios (8.78 and 16.35, respectively). Conclusion Our model could predict PD-L1 expression in patients with lung SCC, and pleural nodularity and pulmonary oligometastases were notable predictive CT features of PD-L1.

Added Value of Structured Reporting for US of the Pediatric Appendix: Additional CT Examinations and Negative Appendectomy (소아 충수 초음파 검사에서 구조화 판독문의 부가가치: 추가 CT 검사 및 음성 충수절제술의 관점에서)

  • Keonwoo Choi;Ji Young Choi;Hyuk Jung Kim;Hyun Jin Kim;Suk Ki Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.653-662
    • /
    • 2023
  • Purpose This study aimed to determine the incremental value of using a structured report (SR) for US examinations of the pediatric appendix. Materials and Methods Between January 2009 and June 2016, 1150 pediatric patients with suspected appendicitis who underwent US examinations of the appendix were included retrospectively. In November 2012, we developed a five-point scale SR for appendix US examinations. The patients were divided into two groups according to the form of the US report: free-text or SR. The primary clinical outcomes were compared between the two groups, including the rate of CT imaging following US examinations, the negative appendectomy rate (NAR), and the appendiceal perforation rate (PR). Results In total, 550 patients were included in the free-text group and 600 patients in the SR group. The rate of additional CT examinations decreased by 5.3% in the SR group (8.2%, p = 0.003), and the NAR decreased by 8.4% in the SR group (7.8%, p = 0.028). There was no statistical difference in the appendiceal PR (37.6% vs. 48.0%, p = 0.078). Conclusion The use of an SR to evaluate US examinations for suspected pediatric appendicitis results in lower CT use and fewer negative appendectomies without an increase in appendiceal PR.

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.