• 제목/요약/키워드: Computed tomography (CT), volume rendering

검색결과 24건 처리시간 0.018초

Occlusion-based Direct Volume Rendering for Computed Tomography Image

  • Jung, Younhyun
    • Journal of Multimedia Information System
    • /
    • 제5권1호
    • /
    • pp.35-42
    • /
    • 2018
  • Direct volume rendering (DVR) is an important 3D visualization method for medical images as it depicts the full volumetric data. However, because DVR renders the whole volume, regions of interests (ROIs) such as a tumor that are embedded within the volume maybe occluded from view. Thus, conventional 2D cross-sectional views are still widely used, while the advantages of the DVR are often neglected. In this study, we propose a new visualization algorithm where we augment the 2D slice of interest (SOI) from an image volume with volumetric information derived from the DVR of the same volume. Our occlusion-based DVR augmentation for SOI (ODAS) uses the occlusion information derived from the voxels in front of the SOI to calculate a depth parameter that controls the amount of DVR visibility which is used to provide 3D spatial cues while not impairing the visibility of the SOI. We outline the capabilities of our ODAS and through a variety of computer tomography (CT) medical image examples, compare it to a conventional fusion of the SOI and the clipped DVR.

치과 원추형 CT 영상 데이터 분석에 효율적인 볼륨 렌더링 방법 (An Efficient Volume Rendering for Dental Diagnosis Using Cone Beam CT data)

  • 구윤모
    • 디지털산업정보학회논문지
    • /
    • 제8권1호
    • /
    • pp.55-64
    • /
    • 2012
  • The advantage of direct volume rendering is to visualize structures of interest in the volumetric data. However it is still difficult to simultaneously show interior and exterior structures. Recently, cone beam computed tomography(CBCT) has been used for dental diagnosis. Despite of its usefulness, there is a limitation in the detection of interior structures such as pulp and inferior alveolar nerve canal. In this paper, we propose an efficient volume rendering model for visualizing important interior as well as exterior structures of dental CBCT. It is based on the concept of illustrative volume rendering and enhances boundary and silhouette of structures. Moreover, we present a new method that assigns a different color to structures in the rear so as to distinguish the front ones from the rear ones. This proposed rendering model has been implemented on graphics hardware, so that we can achieve interactive performance. In addition, we can render teeth, pulp and canal without cumbersome segmentation step.

CT와 MRI 영상을 이용한 간담도계 간접볼륨렌더링 (Indirect Volume Rendering of Hepatobiliary System from CT and MRI Images)

  • 진계환;이태수
    • 한국방사선학회논문지
    • /
    • 제1권2호
    • /
    • pp.23-30
    • /
    • 2007
  • 본 논문에서는 CT(Computed Tomography)와 MRI(Magnetic Resonance Imaging)을 이용하여 획득한 2차원의 복부영상을 영역분할, 문턱치법 등의 전처리과정을 거쳐 3차원영상을 생성하는 방법을 제시함으로써 가상내시경(Virtual Endoscopy)에 응용하고자 한다. 3차원영상 가시화 방법으로는 개인용 컴퓨터에서 이용되는 범용의 그래픽가속기를 이용하여 빠른 속도로 렌더링을 할 수 있는 장점을 가지는 표면볼륨기법을 이용하였다. 여기에 이용한 알고리즘은 계산량이적은 Marching Cubes 이다. 그리고 워크스테션이나 전용의 프로그램이 없더라도 웹 브라우저 상에서 실행되는 가상현실모델링언어(VRML, Virtual Reality Modeling Language)양식의 3차원 영상을 생성하는 방법을 제시한다. CT의 3차원 영상 파일의 노드 수와 삼각형 수 및 크기는 각각 85,367, 174,150, 10,124이었고, MRI의 3차원 영상 파일의 노드 수와 삼각형 수 및 크기는 각각 34,029, 67,824, 3,804이었다.

  • PDF

3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가 (Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering)

  • 성열훈;주용현;임재동;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.208-215
    • /
    • 2009
  • 2차원의 영상을 이용한 돌출형 전립선 비대증의 부피 평가방법에서 돌출부위를 포함시킬 경우와 포함시키지 않을 경우의 부피변화를 3차원 볼륨 렌더링(volume rendering, VR)을 이용하여 비교 평가하고자 한다. 돌출형 전립선 부피측정을 위한 가상 전립선 모델은 곤약을 이용해 임의로 평균 1 cm 정도로 돌출되도록 하여 10 ml에서 각각 10 ml씩 부피를 변화시켜 100 ml까지 총 10 개의 모델을 제작하였다. 이 때 제작된 모델의 부피측정은 64 channel 전산화단층촬영(computed tomography, CT)과 3.0 Tesla 자기공명영상(magnetic resonance image, MRI)을 이용하여 획득된 3차원 볼륨 영상자료로 계측하였다. 산출한 CT와 MRI영상들의 3차원 볼륨데이터 근접성 평가를 위해 wilcoxon 부호순위(signed rank) 검정을 하였다. 또한 획득한 영상자료는 3차원 영상처리를 통하여 볼륨 렌더링으로 재구성한 후 타원체부피공식법을 이용하여 돌출부위를 포함시킬 때와 포함하지 않을 때의 부피를 구하였다. 이 때 돌출 유무에 따라 각각 측정된 부피와 3차원 볼륨 렌더링의 부피를 wilcoxon 부호순위(signed rank) 검정을 사용하여 유의성을 평가했으며 상관계수(pearson's correlation coefficient, r)를 사용하여 상관관계를 분석하였다. 계측된 가상 전립선 모델의 돌출부위길이는 CT에서 $0.90{\pm}0.18\;mm$, MRI에서 $0.75{\pm}0.11\;mm$이었으며, CT와 MRI에서 계측된 3차원 영상 부피의 p-value는 0.414로 유의한 차이는 없었다. 그러나 MRI에서 측정된 3차원 영상 부피와 2차원 영상에서 돌출부위를 포함시킬 때의 p-value는 0.005인 반면 포함하지 않을 때의 p-value는 0.139로 나타났으며, CT에서도 측정된 3차원 영상 부피와 2차원 영상에서 돌출부위를 포함시킬 때의 p-value는 0.005인 반면 포함하지 않을 때의 p-value는 0.057로 나타났다. 돌출형 전립선의 부피측정은 돌출부위를 제외하고 상하길이를 측정하는 것이 3차원 볼륨 렌더링에 의한 부피 값과 더 가까운 부피 값을 얻을 수 있었다.

  • PDF

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.

Computed tomographic anatomy of hepatic artery in normal beagle dogs

  • Kim, Soochan;Jeong, Seongmok;Lee, Heechun;Lee, Youngwon;Choi, Hojung
    • 대한수의학회지
    • /
    • 제59권2호
    • /
    • pp.55-58
    • /
    • 2019
  • This study was performed to examine the visualization and anatomical variants of the hepatic artery with dual-phase computed tomography (CT) angiography and three-dimensional volume rendering imaging analysis in clinically normal dogs. Seven healthy beagle dogs were enrolled and underwent dual CT angiography. Arterial phase images could be obtained with multi-detector CT angiography using the fixed-scan method in these dogs. Contrast enhancement of the hepatic parenchyma was quite minimal because of the unique blood supply system of the liver. In most dogs, the main hepatic arterial branches were the right lateral branch, left branch, and right medial branch. Although hepatic arterial variation appears to be common in dogs, only one dog in this study had the caudate lobar branch as the first branch of the hepatic artery. Further study on a larger number of dogs with CT images will be needed to identify and classify the pattern of hepatic arterial variations.

척추경 나사못 고정술 시행 후 3차원 재구성CT영상의 유용성 평가 (Evaluation on usefulness of three dimensional reconstructive computed tomography images after pedicle screws fixation)

  • 김현주;장현철;조재환
    • 디지털콘텐츠학회 논문지
    • /
    • 제11권4호
    • /
    • pp.553-559
    • /
    • 2010
  • 본 연구는 척추경 나사못 고정술을 시행한 환자를 대상으로 고정술 전, 후 전산화 단층촬영 영상의 원 자료(raw data)를 이용하여 다양한 재구성 기법을 적용하여 나사못의 정확한 위치파악과 수술의 정확도 등 다양한 정보를 알아보고자 하였다. 임상에서 주로 이용 하는 재구성기법인 다평면재구성(MPR), 최대강도투영(MIP), 체적묘사기법(VRT)과 변형 제적묘사기법(modifying VRT)을 적용하여 영상데이터를 각 각 정량적 방법과 정성적 방법으로 비교 분석하였다. 재구성 영상의 분석 및 평가결과 전산화 단층촬영 영상재구성 기법 중 척추경 나사못 고정술 후 나사의 정확한 위치파악과 금속에 의한 인공음영을 최소화 시키는데 가장 유용한 재구성 기법으로는 변형 체적묘사기법으로 사료된다.

정맥 내의 IV 카테터 조각을 3D MDCT 볼륨렌더링 영상으로 구현하기 위한 HU 임계치 (HU Threshold Value for IV Catheter Fragment in Peripheral Vein of Volume Rendering 3D MDCT Imaging)

  • 장근조;권대철
    • 한국콘텐츠학회논문지
    • /
    • 제7권4호
    • /
    • pp.206-212
    • /
    • 2007
  • IV(intravenous) 카데터 조각을 정맥 내에서 정확한 위치 및 크기를 확인하기위해 MDCT의 3D 재구성 기법인 볼륨렌더링의 임계치를 측정하고 변화에 따라 IV 카데터 조각의 영상을 구현하였다. 3D프로그램에서 파일럿 방법으로 IV 카데터의 HU(hounsfield unit) 값을 측정하였고, IV 카데터가 남아 있는 환자를 대상으로 프로파일과 관심영역 테이블 기능을 이용하여 IV 카데터의 HU 값을 측정하여 임계치를 설정하여 IV 카데터 조각의 위치 및 크기를 볼륨렌더링 영상에서 확인 하였다. 볼륨렌더링 영상에서 HU의 임계치 설정은 IV 카데터 조각의 정확한 위치 및 크기를 확인하는데 매우 중요한 요소이다.

전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상 (Subcutaneous Injection Contrast Media Extravasation: 3D CT Appearance)

  • 권대철;김태형;양성환;유병규;김명구;박범
    • 한국의학물리학회지:의학물리
    • /
    • 제16권1호
    • /
    • pp.47-51
    • /
    • 2005
  • 전산화단층검사에서 조영제를 자동주입기를 이용해 주입하여 검사하는 경우에 혈관 외 유출된 성인환자를 대상으로 하였다. 환자의 혈관외유출 사고의 조영제 양은 47 ml로 오른쪽 손목 부위가 부종을 동반하였다. 혈관외유출된 손상부위를 axial 스캔하여 MPR (multi-planar reformation), MIP (maximum intensity protection), volume rendering, SSD (shaded-surface display) 기법으로 구성하였다. 이러한 3D 영상은 조영제의 혈관외유출 환자의 예방 및 사후 조치에 적절한 치료계획의 방법으로 기대된다.

  • PDF

흉부 CT 검사에서 3차원 체적 영상의 정량적 분석 (Quantitative analysis of three dimensional volumetric images in Chest CT)

  • 장현철;조재환;박철수
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.255-260
    • /
    • 2011
  • 본 연구는 흉부 CT 검사 시 늑골 골절 환자를 대상으로 3차원 체적 재구성 기법의 유용성에 대해 알아보고자 하였다. 임상에서 주로 이용 하는 재구성기법인 다평면재구성(MPR), 3차원 체적 영상 기법(VRT)을 적용하여 영상데이터를 각 각 정량적 방법과 정성적 방법으로 비교 분석하였다. 재구성 영상의 분석 및 평가결과 늑골 골절 환자의 흉부 CT 검사 시 조영 전 원 자료를 이용하여 3차원 체적영상으로 재구성 하는 것이 보다 더 인공 음영을 최소화 시켰으며, 늑골 골절 판단 및 3차원 체적 영상 재구성 소요시간이 단축 됨을 알 수 있었다.