• Title/Summary/Keyword: Computed tomography

Search Result 5,410, Processing Time 0.037 seconds

Osteoporotic Vertebral Fractures: SPECT Findings (골다공증에 동반된 척추골절의 골 SPECT 소견)

  • Baik, Jun-Hyun;Park, Young-Ha;Ihn, Yon-Kwon;Kim, Sung-Hoon;Chung, Yong-An;Yoo, Ie-Ryung;Kim, Jee-Yeung;Jung, Hyun-Seok;Sohn, Hyung-Seon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.522-527
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate the usefulness of single photon emission computed tomography (SPECT) of bone using Tc-99m MDP in the diagnosis of osteoporotic vertebral fractures. Materials and Methods: Thirty two patients with osteoporotic vertebral fracture were included in this study (mean age: $67{\pm}8$, male: 5, female: 27). Seventy nine vertebral fractures were detected (38 thoracic/thoracolumbar lesions and 41 lumbar lesions), which were classified by type of deformity (wedge, biconcave or compression). The patterns and locations of increased uptakes were examined and analyzed. Results: Forty seven wedge fractures, 20 biconcave fractures and 12 compression fractures were found. Diffuse and asymmetric uptakes were common in fractured bodies. More than one uptake were examined in 69 posterior elements of fractured vertebrae (87.3%) including 40 of 47 wedge fractures (85.1%), 17 of 20 biconcave fractures (85.0%) and 12 of 12 compression fractures (100%). Wedge fractures were predominant fracture in thoracic/thoracolumbar spine whereas incidence of biconcave or compression type war similar to that of wedge fracture in lumbar spine (p=0.04). Spinous process uptake was more frequently seen in lumbar lesions than thoracic/thoracolumbar lesions (p=0.009). Facet joint uptake in biconcave fracture was more common in lumbar spine (92.3%) than thoracic/thoracolumbar spine (57.1%). Spinous process uptake in biconcave fracture was also more frequently detected in lumbar spine (p=0.043). Conclusion: Bone SPECT was useful in the evaluation of osteoporotic vertebral fracture, especially posterior elements of vertebrae.

Diagnosis and Treatment of Endobronchial Actinomycosis (기관지 방선균증의 임상적 고찰)

  • Choi, Jae Chol;Koh, Won-Jung;Kwon, Yong Soo;Ryu, Yon Ju;Yu, Chang-Min;Jeon, Kyeongman;Kang, Eun Hae;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Kwon, O Jung;Kim, Tae Sung;Lee, Kyung Soo;Han, Joungho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.6
    • /
    • pp.576-581
    • /
    • 2005
  • Background : Thoracic actinomycosis is a relatively uncommon anaerobic infection caused by Actinomyces israelii. There have been only a few case reports of endobronchial actinomycosis. The aim of this study was to evaluate the clinical manifestation and treatment of endobronchial actinomycosis. Material and Methods : Seven patients with endobronchial actinomycosis, who were diagnosed in the past 10 years, were retrospectively reviewed. Results : Cough and sputum were the most common symptoms. The chest radiograph and computed tomography showed necrotic consolidation (n=3), atelectasis (n=2), mass (n=1) and an endobronchial nodule (n=1). Proximal broncholithiasis was observed in five patients. All cases were initially suspected to have either lung cancer or tuberculosis. In these patients, the median duration of intravenous antibiotics was 3 days (range 0-12 days) and the median duration of oral antibiotics was 147 days (range 20-412 days). Two patients received oral antibiotic therapy only. There was no clinical evidence of a recurrence. Conclusion : Endobronchial actinomycosis frequently manifests as a proximal obstructive calcified endobronchial nodule that is associated with distal post-obstructive pneumonia. The possibility of endobronchial actinomycosis is suggested when findings of broncholithiasis are present at chest CT. The traditional recommendation of 2-6 weeks of intravenous antibiotics and 6-12 months of oral antibiotic therapy are not necessarily essential in all cases of endobronchial actinomycosis.

Etiologic Distribution, Diagnostic Tests and Treatment in Prospectively Registered Patients with DILD for Two Years in a Tertiary Medical Center (한 3차 병원에서 2년간 전향적으로 등록된 DILD 환자의 원인, 진단 수기 및 치료 현황)

  • Kwon, Yong Soo;Chung, Man Pyo;Jeon, Gyeong Man;Lyu, Yeon Ju;Yu, Chang Min;Choi, Jae Chul;Kang, Eun Hae;Koh, Won-Jung;Suh, Gee Young;Kim, Hojoong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.6
    • /
    • pp.570-575
    • /
    • 2005
  • Introduction : Diffuse interstitial lung diseases (DILD) comprise of a large group of lung diseases with diverse etiologies. They are classified into four categories based on the etiology and pathological findings. In Korea, epidemiological data on DILD has never been reported in a prospective manner. Method : From May 2002 to April 2004, total 487 patients with DILD were prospectively registered at Samsung Medical Center. The prospective observational analysis of the etiologies, its classification based on 2002 ATS/ERS (American Thoracic Society/European Respiratory Society) guidelines, as well as diagnostic tests and the retrospective analysis of the treatment modalities were carried out. Any infectious and malignant causes were excluded. Results : 1) The patients were classified into idiopathic interstitial pneumonia (IIP) in 269 patients (55.2%), known causes of DILD in 168 patients (34.5%), sarcoidosis in 27 patients (5.5%), other forms of DILD in 14 patients (2.9%), and undetermined DILD in 9 patients (1.9%). 2) The diagnostic test showed that most patients had undergone chest high resolution computed tomography (HRCT) and pulmonary function test (PFT) (97%, 89%). Transbronchial lung biopsy (TBLB) and surgical lung biopsy (SLB) were performed in limited patients (38%, 29%). 3) Among 269 patients with IIP, 220 (82%) had idiopathic pulmonary fibrosis (IPF) while 23 (9%) had nonspecific interstitial pneumonia. SLB was carried out in 36% of patients with IIP. 4) Symptomatic supportive care was given to 67% of IPF, but specific medical treatment including corticosteroids was administered to 89% of non-IPF patients. Conclusion : A nationwide registry of DILD patients is required to determine the annual incidence, etiology, and practice pattern of diagnosis and treatment in Korea.

Twelve Years of Experience with Vascular Ring Surgery (혈관륜 수술의 12년 경험 보고)

  • Kim, Yun-Seok;Goo, Hyun-Woo;Jhang, Won-Kyoung;Yun, Tae-Jin;Seo, Dong-Man;Park, Jeong-Jun
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.749-756
    • /
    • 2009
  • Background: Vascular ring is a rare anomaly of the aortic arch. We did surgical repair procedures on 16 cases of vascular ring over the past 12 years. This article reviews our results. Material and Method: Between 1995 and 2007, 16 patients (5 with double aortic arch, 7 with right aortic arch-left ligamentum, 4 with pulmonary artery sling) underwent surgical repair. Mean age at the time of the operation were as follows: double aortic arch, $5.7{\pm}5.5$ years; right aortic arch-left ligamentum, $6.1{\pm}13.4$ years; pulmonary artery sling, $2.9{\pm}2.6$ years. Five patients (71%) with right aortic arch-left ligamentum had an associated Kommerell's diverticulum. Two patients (40%) with double aortic arch, 2 patients (28.6%) with right aortic arch-left ligament and 4 patients (100%) with pulmonary artery sling had associated airway stenosis. Cardiac anomalies were present in 8 of 16 patients. Result: There was no peri-operative or post-operative mortality. The mean hospital stay was $27.1{\pm}38.2$ days. None of our patients underwent reoperation. Conclusion: Vascular ring is rare, but, it needs surgical correction. It is important to suspect the diagnosis and to validate with echocardiography. Preoperative and postoperative computed tomography and bronchoscopy are useful to evaluate the airway and surrounding structures.

A Suggested New Clinical Classification for Pediatric Intussusception (소아 장중첩증의 새로운 임상적 분류의 제안)

  • Park, Moon Ho;Shon, Su Min;Choe, Byung Kyu;Kim, Yeo Hyang;Lee, Hee Jung;Choi, Won Joung;Kim, Ae Suk;Hwang, Jin-Bok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.1
    • /
    • pp.39-47
    • /
    • 2006
  • Purpose: We proposed a new classification of pediatric intussusception based on clinical and radiologic findings. Methods: Data from 88 consecutive patients with intussusception were reviewed. We retrospectively analyzed six factors; patient age, sites of intussusception, symptoms, therapeutic methods, existence of enlarged mesenteric lymph nodes, and ultrasonographic (US) findings from clinical records. Results: 1) There was one neonatal case (1.1%), the others (98.9%) were infants and children. 2) These 87 infant and child cases consisted of 14 cases (16.1%) of small bowel intussusception (SBI) and 73 cases (83.9%) of ileo-colic intussusception (ICI). Of the 14 SBI cases, 12 cases were symptomatic and 2 cases were asymptomatic. The symptomatic group comprised 8 transient cases (66.7%), 3 operative cases (25.0%), and 1 enema-reduction case (8.3%). Two asymptomatic cases were incidentally captured by computed tomography. Of the 73 ICI cases, 19 cases (26.0%) required operation, and 54 (74.0%) enema-reduction. 3) When transient SBI cases were compared with operated SBI cases, enema-reduced and operated ICI cases, the age ($38.0{\pm}22.9$ months) of transient SBI cases were significantly higher than those of the others (p=0.003). Mean mass size ($20.8{\pm}2.7mm$) in transient SBI was significantly smaller than in the others (p=0.0001). 4) No correlation was found between the existence of enlarged mesenteric lymph nodes and therapeutic method or concomitant illness. 5) Most of the target types observed by US were in transient SBI cases, the remainder were in the enema-reduced ICI cases. In terms of the doughnuts type, all 8 cases (34.8%) with an external hypoechoic rim thickness of >8.9mm were treated surgically. Conclusion: Pediatric intussusception may be classified based on clinical and radiologic findings, which are likely to indicate appropriate therapies.

  • PDF

Radiation Absorbed Dose Measurement after I-131 Metaiodobenzylguanidine Treatment in a patient with Pheochromycytoma (갈색세포종 환자에서 Medical Internal Radiation Dose법을 이용한 I-131 Metaiodobenzylguanidine 치료 후 흡수선량 평가)

  • Yang, Weon-Il;Kim, Byeung-Il;Lee, Jae-Sung;Lee, Jung-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.422-429
    • /
    • 1999
  • Purpose: The measurement of radiation absorbed dose is useful to predict the response after I-131 labeled metaiodobenzylguanidine (MIBG) therapy and determine therapy dose in patients with unresectable or malignant pheochromocytoma. We estimated the absorbed dose in tumor tissue after high dose I-131 MIBG in a patient with pheochromocytoma using a gamma camera and Medical Internal Radiation Dose (MIRD) formula. Materials and Methods: A 64-year old female patient with pheochromocytoma who had multiple metastases of mediastinum, right kidney and periaortic lymph nodes, received 74 GBq (200 mCi) of I-131 MIBG. We obtained anterior and posterior images at 0.5, 16, 24, 64 and 145 hours after treatment. Two standard sources of 37 and 74 MBq of I-131 were imaged simultaneously. Cummulated I-131 MIBG uptake in tumor tissue was calculated after the correction of background activity, attenuation, system sensitivity and count loss at a high count rate. Results: The calculated absorbed radiation dose was 32-63 Gy/ 74 GBq, which was lower than the known dose for tumor remission (150-200 Gy). follow-up studies at 1 month showed minimally reduced tumor size on computed tomography, and mildly reduced I-131 MIBG uptake. Conclusion: We estimated radiation absorbed dose after therapeutic I-131 MIBG using a gamma camera and MIRD formula, which can be peformed in a clinical nuclear medicine laboratory. Our results suggest that the measurement of radiation absorbed dose in I-131 MIBG therapy is feasible as a routine clinical practice that can guide further treatment plan. The accuracy of dose measurement and correlation with clinical outcome should be evaluated further.

  • PDF

Usefulness of Customized Cervical Spine Immobilizer in Head & Neck Image-Guided Radiation Therapy with Tomotherapy® (토모테라피를 이용한 두경부암 영상유도 방사선 치료 시 개인별 경추고정용구의 유용성 평가)

  • Jin, Sung Eun;Chang, Se Wuk;Choi, Jung Hoan;Kim, Min Joo;Ahn, Seung Kwon;Lee, Sang Kyu;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.65-71
    • /
    • 2018
  • Purpose : Standardized pillow may not support patient's individual cervical spine thoroughly when head and neck radiation therapy with $Tomotherapy^{(R)}$. Therefore, the purpose of this study was to make a comparative analysis for the difference of using standardized pillow only and using customized cervical spine immobilizer with standardized pillow. Materials and Methos : The head and neck cancer patients who are treated image-guided radiation therapy(IGRT) with $Tomotherapy^{(R)}$ were divided into two groups, 20 patients using standardized pillow only, and 20 patients using customized cervical spine immobilizer with standardized pillow. We achieved 20 mega-voltage computed tomography(MVCT) image per patient, compared curvature of the cervical spine in MVCT with curvature of the cervical spine in CT-simulation. Results : Results of comparative analysis were curvature consistency 95.9 %, maximum error of distance 41.9 mm, average distance error per fractionation 19.4 mm, average standard deviation 1.34 mm in case of using standardized pillow only, curvature consistency 98.9 %, maximum error of distance 12.9 mm, average distance error per fractionation 5.8 mm, average standard deviation 0.59 mm in case of using customized cervical spine immobilizer with standardized pillow. Conclusion : Using customized cervical spine immobilizer shows higher reproducibility and low distance error, therefore customized cervical spine immobilizer could be useful for head and neck cancer patients who need radiation therapy.

  • PDF

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.

Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy (검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가)

  • Kang, Young-Eun;Jung, Woo-Young;Hong, Bo-Ruem
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Purpose An examination guide is a useful medium to provide the patient with an overview, pre- and post-test preparation, and precautions of nuclear testing. The design and arrangement of existing written texts and announcements were evaluated to elucidate the comprehension of patients undergoing testing. Materials and Methods Informational material describing bone scanning and $^{201}thallium$ myocardium perfusion single-photon emission computed tomography (SPECT), as a secondary examination, which accounts for the largest portion of gamma imaging at Asan Hospital (Seoul, South Korea), was selected as an improvement target in consultation with a national innovation center. Existing informational material was dispensed to patients scheduled for bone scans from November 2016 to February 2017 and the revised material was issued from March 2017 to May 2017. A survey was conducted of 200 patients who underwent $^{201}thallium$ myocardium perfusion SPECT before and after the revisions (n = 100 each time period) to assess the patients' understanding of the informational material. Results When comparing the use of the conventional vs. revised material, the number of patients who received treatment before bone scanning had decreased from 130 to 60, while the number of those who required additional imaging decreased from 53 to 14. Prior to the revision, 43% of patients underwent testing before preparation and 18% underwent additional testing. The decreased need for additional image acquisition after revision of the informational material resulted in a decrease in acquisition time of about 2 min, from 16.5 to 14.2 min. In the case of $^{201}thallium$ myocardium perfusion SPECT, patient comprehension of all five items surveyed had increased, while the number of patients who had repeatedly asked about various facets of the procedure pre- and post-testing had decreased from 36% to 16% and 31% to 14%, respectively. Conclusion Lower patient comprehension is accompanied by a decrease in image quality due to non-compliance during pre-testing and may lead to repetitive questions from the patient, which may also negatively affect the fatigue and work efficiency of the examiner. Improved readability and visibility of informational material through visualization was correlated with greater patient comprehension as well as improved image quality and acquisition time.

An investigation Of IntraFraction Motion Correction For Lung Stereotactic Body Radiation Therapy By Using IntraFraction Cone Beam Computed Tomography (폐암 환자의 정위적 체부 방사선 치료 시 IntraFraction CBCT를 이용한 치료 중 자세 오차 교정에 대한 고찰)

  • Song, Hyeong Seok;Cho, Kang Chul;Park, Hyo Kuk;Yoon, Jong Won;Cho, Jung Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Purpose: The purpose is to correct for position errors caused by long treatment times. By correcting the target motion that can occur during lung SBRT using IntraFraction CBCT. Methods and materials: We analyzed retrospectively the IFM data of 14 patients with two treatment arc in the treatment plan for lung cancer with stereotactic radiotherapy. An IntraFraction Motion was applied to the Arccheck phantom to acquire the Gamma index data. Results : IntraFraction Motion during the first treatment arc is in the left-right(LR), superiorinferior(SI), anterior-posterior(AP) directions were $0.16{\pm}0.05cm$, 0.72 cm(max error), $0.2{\pm}0.14cm$, 1.26 cm, $0.24{\pm}0.08cm$, 0.82 cm and rotational directions was $0.84{\pm}0.23^{\circ}$, $2.8^{\circ}$(pitch), $0.72{\pm}0.23^{\circ}$, $2.5^{\circ}$(yaw), $0.7{\pm}0.19^{\circ}$, $2^{\circ}$(roll). IntraFraction Motion during the second treatment arc is in the LR, SI, AP directions were $0.1{\pm}0.04cm$, 0.37 cm, $0.14{\pm}0.17cm$, 2 cm, $0.12{\pm}0.04cm$, 0.5 cm and rotational directions was $0.45{\pm}0.12^{\circ}$, $1.3^{\circ}$, $0.37{\pm}0.1^{\circ}$, $1^{\circ}$, $0.35{\pm}0.1^{\circ}$, $1.2^{\circ}$. Gamma index pass rates were $82.64{\pm}10.51%$, 48.4 %. Conclusions : In this study, we examined the validity of IntraFraction Motion correction in lung SBRT and the efficiency of IntraFraction CBCT. Due to the nature of SBRT treatment, IFM may increase due to the increased treatment time. It is believed that the increase in IFM with the increase in treatment time can be improved with the use of FFF Beam and additional position correction using CBCT during treatment.