• 제목/요약/키워드: Computed Tomography, Perfusion Study

검색결과 55건 처리시간 0.024초

Comparison of Predicted Postoperative Lung Function in Pneumonectomy Using Computed Tomography and Lung Perfusion Scans

  • Kang, Hee Joon;Lee, Seok Soo
    • Journal of Chest Surgery
    • /
    • 제54권6호
    • /
    • pp.487-493
    • /
    • 2021
  • Background: Predicting postoperative lung function after pneumonectomy is essential. We retrospectively compared postoperative lung function to predicted postoperative lung function based on computed tomography (CT) volumetry and perfusion scintigraphy in patients who underwent pneumonectomy. Methods: Predicted postoperative lung function was calculated based on perfusion scintigraphy and CT volumetry. The predicted function was compared to the postoperative lung function in terms of forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1), using 4 parameters: FVC, FVC%, FEV1, and FEV1%. Results: The correlations between postoperative function and predicted function based on CT volumetry were r=0.632 (p=0.003) for FVC% and r=0.728 (p<0.001) for FEV1%. The correlations between postoperative function and predicted postoperative function based on perfusion scintigraphy were r=0.654 (p=0.002) for FVC% and r=0.758 (p<0.001) for FEV1%. The preoperative Eastern Cooperative Oncology Group (ECOG) scores were significantly higher in the group in which the gap between postoperative FEV1 and predicted postoperative FEV1 analyzed by CT was smaller than the gap analyzed by perfusion scintigraphy (1.2±0.62 vs. 0.4±0.52, p=0.006). Conclusion: This study affirms that CT volumetry can replace perfusion scintigraphy for preoperative evaluation of patients needing pneumonectomy. In particular, it was found to be a better predictor of postoperative lung function for poor-performance patients (i.e., those with high ECOG scores).

Assessment of Cerebral Circulatory Arrest via CT Angiography and CT Perfusion in Brain Death Confirmation

  • Asli Irmak Akdogan;Yeliz Pekcevik;Hilal Sahin;Ridvan Pekcevik
    • Korean Journal of Radiology
    • /
    • 제22권3호
    • /
    • pp.395-404
    • /
    • 2021
  • Objective: To compare the utility of computed tomography perfusion (CTP) and three different 4-point scoring systems in computed tomography angiography (CTA) in confirming brain death (BD) in patients with and without skull defects. Materials and Methods: Ninety-two patients clinically diagnosed as BD using CTA and/or CTP for confirmation were retrospectively reviewed. For the final analysis, 86 patients were included in this study. Images were re-evaluated by three radiologists according to the 4-point scoring systems that consider the vessel opacification on 1) the venous phase for both M4 segments of the middle cerebral arteries (MCAs-M4) and internal cerebral veins (ICVs) (A60-V60), 2) the arterial phase for the MCA-M4 and venous phase for the ICVs (A20-V60), 3) the venous phase for the ICVs and superior petrosal veins (ICV-SPV). The CTP images were independently reviewed. The presence of an open skull defect and stasis filling was noted. Results: Sensitivities of the ICV-SPV, A20-V60, A60-V60 scoring systems, and CTP in the diagnosis of BD were 89.5%, 82.6%, 67.4%, and 93.3%, respectively. The sensitivity of A20-V60 scoring was higher than that of A60-V60 in BD patients (p < 0.001). CTP was found to be the most sensitive method (86.5%) in patients with open skull defect (p = 0.019). Interobserver agreement was excellent in the diagnosis of BD, in assessing A20-V60, A60-V60, ICV-SPV, CTP, and good in stasis filling (κ: 0.84, 0.83, 0.83, 0.83, and 0.67, respectively). Conclusion: The sensitivity of CTA confirming brain death differs between various proposed 4-point scoring systems. Although the ICV-SPV is the most sensitive, evaluation of the SPV is challenging. Adding CTP to the routine BD CTA protocol, especially in cases with open skull defect, could increase sensitivity as a useful adjunct.

초음파 유도하 침 생검을 이용한 연부조직 종양의 진단에 있어 양전자방출 컴퓨터 단층촬영술의 유용성 (Availability of Positron Emission Tomography-Computed Tomography for the Diagnosis of the Soft Tissue Tumor through Ultrasound-Guided Biopsy)

  • 전세빈;김정일;이인숙;송유선;최경운
    • 대한정형외과학회지
    • /
    • 제56권5호
    • /
    • pp.398-403
    • /
    • 2021
  • 목적: 연부조직 종양의 진단을 위해서는 생검이 필요하지만, 육종 등 이질성을 가진 종양들의 특징상 정확한 부위의 채취가 어려워 수술적 개방 생검으로도 진단이 어려운 경우가 많다. 이 경우 초음파 유도하 침생검이 진단율을 올릴 수 있는 방법으로 사용되고 있다. 본 연구는 자기공명 관류영상(magnetic resonance perfusion)에서 발견된 연부조직 종양을 진단하는 데 있어 초음파 유도하 침 생검의 정확도를 평가하고, 양전자방출 컴퓨터 단층촬영술(positron emission tomography-computed tomography, PET-CT)의 유용성에 대해 알고자 하였다. 대상 및 방법: 2014년 1월부터 2018년 12월까지 자기공명 관류영상에서 발견된 연부조직의 종양에 대해 초음파 유도하 침 생검을 시행한 총 152예의 환자들 중 최종 진단을 얻어 초음파 유도하 침 생검의 결과와 비교할 수 있었던 86예에 대해 그 정확도를 후향적으로 평가하였다. 총 86예의 환자를 자기공명 관류영상만을 시행한 50예와 자기공명 관류영상과 PET-CT를 함께 시행한 36예로 나누어 그 정확도를 비교, 분석하여 PET-CT가 초음파 유도하 침 생검의 정확도를 향상시킬 수 있는지 알고자 하였다. 결과: 총 86예의 환자들 중 자기공명 관류영상만을 시행한 50예 중에서는 34예에서 최종 진단과 초음파 유도하 침 생검의 결과가 일치하였으며, 자기공명 관류영상과 PET-CT를 함께 시행한 36예 중에서는 32예에서 최종 진단과 초음파 유도하 침 생검의 결과가 일치하여 초음파 유도하 침 생검의 정확도에 있어 유의한 차이를 보였다. 이 중 연부 조직 육종만 따로 분류한다면 자기공명 관류영상만을 시행한 12예 중에서 6예에서 최종 진단과 초음파 유도하 침 생검의 결과가 일치하였고 자기공명 관류영상과 PET-CT를 함께 시행한 18예 중에서는 17예에서 최종 진단과 초음파 유도하 침 생검의 결과가 일치하여 마찬가지로 초음파 유도하 침 생검의 정확도에 있어 유의한 차이를 보였다. 결론: 연부조직 종양을 진단함에 있어 초음파 유도하 침 생검은 정확도가 높은 유용한 검사로 알려져 있지만 육종의 경우 이질성이 있어 자기공명 관류영상만으로는 정확한 생검 부위를 설정하는 데 어려움이 있다. PET-CT 영상은 이러한 연부조직 종양에서 침 생검 부위를 특정하고 정확도를 유의하게 향상시킬 수 있을 것으로 생각된다.

Perfusion Computed Tomography in Predicting Treatment Response of Advanced Esophageal Squamous Cell Carcinomas

  • Li, Ming-Huan;Shang, Dong-Ping;Chen, Chen;Xu, Liang;Huang, Yong;Kong, Li;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권2호
    • /
    • pp.797-802
    • /
    • 2015
  • Background: The purpose of this study was to prospectively evaluate the predictive value of perfusion computed tomography (CT) for response of local advanced esophageal carcinoma to radiotherapy and chemotherapy. Materials and Methods: Before any treatment, forty-three local advanced esophageal squamous cell carcinomas were prospectively evaluated by perfusion scan with 16-row CT from June 2009 to January 2012. Perfusion parameters, including perfusion (BF), peak enhanced density (PED), blood volume (BV), and time to peak (TTP) were measured using Philips perfusion software. Seventeen cases received definitive radiotherapy and 26 received concurrent chemo-radiotherapy. The response was evaluated by CT scan and esophagography. Differences in perfusion parameters between responders and non-responders were analyzed, and ROCs were used to assess predictive value of the baseline parameters for treatment response. Results: There were 25 responders (R) and 18 non-responders (NR). Responders showed significantly higher BF (R:34.1 ml/100g/min vs NR: 25.0 ml/100g/min, p=0.001), BV (23.2 ml/100g vs 18.3 ml/100g, p=0.009) and PED (32.5 HU vs 28.32HU, P=0.003) than non-responders. But the baseline TTP (R: 38.2s vs NR: 44.10s, p=0.172) had no difference in the two groups. For baseline BF, a threshold of 36.1 ml/100g/min achieved a sensitivity of 56%, and a specificity of 94.4% for detection of clinical responders from non-responders. Conclusions: The results suggest that the perfusion CT can provide some helpful information for identifying tumors that may respond to radio-chemotherapy.

Sphenoid Ridge Meningioma Presenting as Acute Cerebral Infarction

  • Ko, Jun Kyeung;Cha, Seung Heon;Choi, Chang Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권2호
    • /
    • pp.99-102
    • /
    • 2014
  • A previously healthy 52-year-old man presented to the emergency room with acute onset left hemiparesis and dysarthria. Brain computed tomography and magnetic resonance examinations revealed acute cerebral infarction in the right middle cerebral artery territory and a sphenoid ridge meningioma encasing the right carotid artery terminus. Cerebral angiography demonstrated complete occlusion of the right proximal M1 portion. A computed tomography perfusion study showed a wide area of perfusion-diffusion mismatch. Over the ensuing 48 hours, left sided weakness deteriorated despite medical treatment. Emergency extracranial-intracranial bypass was performed using a double-barrel technique, leaving the tumor as it was, and subsequently his neurological function was improved dramatically. We present a rare case of sphenoid ridge meningioma causing acute cerebral infarction as a result of middle cerebral artery compression.

Associations between Brain Perfusion and Sleep Disturbance in Patients with Alzheimer's Disease

  • Im, Jooyeon J.;Jeong, Hyeonseok S.;Park, Jong-Sik;Na, Seung-Hee;Chung, Yong-An;Yang, YoungSoon;Song, In-Uk
    • 대한치매학회지
    • /
    • 제16권3호
    • /
    • pp.72-77
    • /
    • 2017
  • Background and Purpose Although sleep disturbances are common and considered a major burden for patients with Alzheimer's disease (AD), the fundamental mechanisms underlying the development and maintenance of sleep disturbance in AD patients have yet to be elucidated. The aim of this study was to examine the correlation between regional cerebral blood flow (rCBF) and sleep disturbance in AD patients using technetium-99m hexamethylpropylene amine oxime single-photon emission computed tomography (SPECT). Methods A total of 140 AD patients were included in this cross-sectional study. Seventy patients were assigned to the AD with sleep loss (SL) group and the rest were assigned to the AD without SL group. SL was measured using the sleep subscale of the Neuropsychiatric Inventory. A whole-brain voxel-wise analysis of brain SPECT data was conducted to compare the rCBF between the two groups. Results The two groups did not differ in demographic characteristics, severity of dementia, general cognitive function, and neuropsychiatric symptoms, with the exception of sleep disturbances. The SPECT imaging analysis displayed decreased perfusion in the bilateral inferior frontal gyrus, bilateral temporal pole, and right precentral gyrus in the AD patients with SL group compared with the AD patients without SL group. It also revealed increased perfusion in the right precuneus, right occipital pole, and left middle occipital gyrus in the AD with SL group compared with the AD without SL group. Conclusions The AD patients who experienced sleep disturbance had notably decreased perfusion in the frontal and temporal lobes and increased rCBF in the parietal and occipital regions. The findings of this study suggest that functional alterations in these brain areas may be the underlying neural correlates of sleep disturbance in AD patients.

정량적 게이트 심근관류 SPECT (Quantitative gated myocardial perfusion SPECT)

  • 안병철
    • 대한핵의학회지
    • /
    • 제37권4호
    • /
    • pp.207-218
    • /
    • 2003
  • Myocardial perfusion imaging has been increasingly used to provide prognostic data and guidance on the choice of appropriate management of patients with known or suspected coronary artery disease. The electrocardiogram gated myocardial SPECT program is corning into wide use with an advent of $^{99m}Tc-labeled$ tracers and an improvement of SPECT machines. The gated technique permits measurement of important cardiac prognostic indicators without any further discomforts or radiation burden in patients underwent standard myocardial perfusion SPECT. In addition, gated study significantly improves diagnostic yield by reducing the number of borderline interpretations and could find myocardial stunning and viable myocardium. Gated single photon emission computed tomography (SPECT) imaging allows the automated calculation of end-diastolic volume, end-systolic volume, ejection fraction, myocardial mass and the assessment of regional wall motion and thickening, and it have dramatically improved assessment of coronary artery disease in routine nuclear practice. This allows the simultaneous assessment of both perfusion and function within the same acquisition, and serves as a cost-effective technique for providing more diagnostic data with fewer diagnostic tests. Because the diagnostic and prognostic power derived from knowledge of left ventricular function can be added to that provided by assessing myocardial perfusion, gated SPECT imaging has rapidly gained widespread acceptance and is now used on a routine clinical basis in a growing number of laboratories, including South Korea. The gated SPECT technique for measurement of left ventricular parameters has been validated against a variety of well established techniques. In this work, overview of gated myocardial perfusion SPECT focus on functional parameters is presented.

두부외상 환자에서 HMPAO-SPECT를 이용한 국소 뇌혈류 변화의 평가 (Spect Assessment of Regional Cerebral Perfusion Abnormality in Head Injury)

  • 이경한;김철희;장하성
    • 대한핵의학회지
    • /
    • 제26권2호
    • /
    • pp.235-243
    • /
    • 1992
  • Patterns of abnormality in regional cerebral perfusion and its relation to clinical severity was evaluated with 32 head injury patients using $^{99m}Tc-HMPAO$ single photon emission tomography (SPECT). The findings were compared with computed tomography (CT) done within 48 hours of each SPECT study. The initial SPECT study was done within 7 days of injury in 16 cases, between 1 week and 2 months in 12, and after over 2 months in 4. Nineteen of the patients underwent followup SPECT and CT after a mean interval of 1 to 2 months. The initial SPECT showed abnormalities in 96% (31/32) of the patients while CT showed abnormal findings in only 81% (26/32). There were a total of 54 supratentorial SPECT lesions in all. Ninity percent (49/54) of these were of regional hypoperfusion, while 5 lesions showed focal hyperperfusion. The lesions were most often localized in the frontal and temporal lobes. Fifty five percent (30/54) were areas not detected as a lesion on CT. Cerebellar diaschisis was observed in 50% (16/32) of the patients. The degree of perfusion abnormality was quantified by the product of differential activity and a size factor. Correlation between the degree of perfusion abnormality and the clinical severity (Glasgow coma scale) failed to show statistical significance (p=0.053). The amount of change in the degree of perfusion abnormality on follow up SPECT was compared to the amount of change in clinical severity. Perfusion abnormality showed a tendancy to improve in most patients, and the degree of improvement showed significant correlation with the amount of clinical improvement (p < 0.01).

  • PDF

초급성 허혈성 뇌졸중에서 관류 전산화단층촬영의 임상적 적용에 대한 연구 (Clinical Application of Acute Ischemic Stroke in Perfusion Computed Tomography)

  • 이종석;유병규;권대철
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.149-160
    • /
    • 2007
  • 초급성 허혈성 뇌졸중 환자를 대상으로 관류 전산화단층촬영(CT)의 임상적 적용을 평가하였다. 뇌졸중 증상 발현 62명의 환자를 대상으로 하였고, 관류 CT는 소뇌 기저부위에서 8 cm 상방으로 스캔하여 후처리 과정을 거쳐 뇌혈용적(cerebral blood volume, CBV), 뇌혈류량(cerebral blood flow, CBF), 평균 조영제 통과시간(mean transit time, MTT) 및 조영제 최고 도달시간(time to peak, TTP) 등의 네 가지 지도의 영상을 얻었다. 관류 CT의 CBV, CBF, MTT, TTP 지도에서 병변을 평가하였으며, 병변 부위와 정상측 대칭부위에서 MTT와 TTP를 측정하여 차이를 비교하였다. 관류 CT의 네 가지 지도 모두에서 관류결손을 인지할 수 있었고, 관류 결손이 인지되는 부위에서 MTT와 TTP의 현저한 지연이 있었다. 관류 CT의 MTT와 TTP영상이 초급성 허혈성 경계부위의 페넘브라를 반영하였다. 관류 CT의 네 가지 지도를 이용하면 뇌졸중의 조기 진단, 허혈 중심부, 허혈 페넘브라를 알 수 있게 되어 관류결손 부위의 혈류역동학적 평가가 가능함으로써, 허혈성 뇌졸중 환자의 진단 및 효과적인 치료를 위해 관류 CT가 유용하여 임상적 적용이 가능하다.

  • PDF

급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구 (Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study)

  • 박하영;편도영;김다혜;정영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.543-547
    • /
    • 2016
  • 급성 뇌졸중(acute stroke)의 경우 빠른 처치가 이루어지지 않으면 뇌손상으로 인해 평생 장애를 가지고 살아가야 하는 질환이다. 따라서 뇌졸중 환자가 발생할 경우에는 신속한 진단과 치료가 이루어져야 하므로 장시간의 검사를 해야 하는 MRI 보다는 빠른 검사와 3D 구현이 가능한 뇌 관류전산화단층촬영(Brain Perfusion CT)이 널리 활용되고 있다. 그러나 환자에게 많은 방사선 피폭이 이루어질 수 있기 때문에 저선량(low dose) 기법을 사용하여 영상을 획득하게 된다. 이로 인해 촬영된 영상의 질 저하가 유발되며, 특히 가우시안노이즈의 영향을 크게 받아 정확한 혈관 영상의 확인을 저해한다. 본 연구에서는 관류전산화단층촬영을 통해 얻어진 동적 CT 데이터에 시공간 분석 기법을 적용하여 진단 영상의 질을 향상시키고자 한다. 특히, 가우시안노이즈를 제거하기 위해서 선형 특징 축출 방법 중 하나인 주성분 분석 기법을 적용하여 분석하였으며, 그 결과 시공간 특징에 따른 각각의 관류 영상 성분을 축출한 경우 뇌-혈관 영상뿐만 아니라 뇌-실질 영상의 질이 향상됨을 가시적으로 확인할 수 있었다. 새롭게 시도된 시공간 기반 영상기법이 향후 급성 뇌졸중 진단뿐만 아니라 다양한 시계열 정보가 포함된 뇌질환 진단 영상분석에 활용된다면, 임상 진단의 질 향상에 도움이 될 것이라 기대한다.