• 제목/요약/키워드: Computed Tomographic

검색결과 484건 처리시간 0.03초

Development of 'De novo' Aneurysm after Therapeutic Carotid Occlusion

  • Jin, Sung-Chul;Choi, Choong-Gon;Kwon, Do-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권4호
    • /
    • pp.236-239
    • /
    • 2009
  • Carotid occlusion is an inevitable therapeutic modality for the treatment of complex aneurysms such as giant, traumatic, and intracavernous aneurysms. Late complications of carotid occlusion include 'de novo' aneurysm formation at a distant site because of hemodynamic changes in the circle of Willis. We report a case of de novo aneurysm in a vessel that appeared to be normal on initial angiography. The patient developed an anterior communicating artery aneurysm and marked growth of a basilar bifurcation aneurysm 9 years after trapping of the left internal carotid artery for the treatment of a ruptured large saccular aneurysm involving ophthalmic and cavernous segments. We propose that patients who undergo therapeutic carotid occlusion should be periodically followed by magnetic resonance angiography or computed tomographic angiography to evaluate the possibility of de novo aneurysm formation; this advice is in line with previous reports.

CT Lymphangiography with Contrast Medium Injection into the Perianal Subcutaneous Region in a Dog with Chylothorax

  • Kim, Kitae;Choen, Sangkyung;Hwang, Jaewoo;Jang, Moonjung;Yoon, Junghee;Choi, Mincheol
    • 한국임상수의학회지
    • /
    • 제35권6호
    • /
    • pp.299-301
    • /
    • 2018
  • A 7-year-old intact female Shih-Tzu with chylothorax was presented. Percutaneous popliteal computed tomographic lymphangiography was performed to evaluate the thoracic duct and seek any potential cause of chylothorax. Despite two attempts, visualization of the thoracic duct failed and perianal subcutaneous computed tomographic lymphangiography with injection of iodinated, nonionic water-soluble contrast medium (0.6 ml/kg) was performed. A single branch of intact thoracic duct and dilated and tortuous lymphatics were detected. It was diagnosed as idiopathic chylothorax. Perianal subcutaneous lymphangiography is considered a less-invasive, easy and reliable method to visualize lymphatics in patients with chylothorax.

A Type 1 Persistent Proatlantal Artery Originating from the External Carotid Artery Detected by Computed Tomographic Angiography

  • Choi, Yunsuk;Chung, Sang Bong;Kim, Myoung Soo
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제20권4호
    • /
    • pp.231-234
    • /
    • 2018
  • A persistent proatlantal artery (PA) is rare. We report a type 1 persistent PA originating from the right external carotid artery (ECA). A 78-year-old woman presented with dizziness. Computed tomographic (CT) angiography showed a persistent PA originating from the right ECA. This persistent PA did not pass through the atlas transverse foramen. The extracranial segment of this artery in the atlas transverse process level had a more lateral position than a normal left vertebral artery. CT angiography well demonstrated the relationship with bony structures and the course of this persistent PA. This anomalous artery in our patient presented as an incidental finding. Surgeon should recognize a persistent PA when performing carotid endarterectomy or ligation of the ECA for avoidance of complication.

Determination of Aneurysmal Location with 3 Dimension-Computed Tomographic Angiography in the Microsurgery of Paraclinoid Aneurysms

  • Kim, Min-Young;Chung, Seung-Young;Kim, Seung-Min;Park, Moon-Sun;Jung, Sung-Sam
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권1호
    • /
    • pp.35-41
    • /
    • 2007
  • Objective : Determining the location of paraclinoid aneurysms for microsurgery is important for selecting treatment options, especially when deciding on the release of the dural ring in direct clipping. We examined the reliability of using the optic strut as an anatomical landmark for evaluating the location of paraclinoid aneurysms. Methods : Cadaveric dissection was performed to establish the relationship of the optic strut to the dural ring. Results from these anatomic studies were compared with the three-demensional computed tomographic angiographic [3D-CTA] findings of nine patients with ten paraclinoid aneurysms between May 2004 and October 2005. These, 3D-CTA results were then compared with intraoperative findings. Results : The inferior boundary of the optic strut accurately localized the point at the proximal dural ring in cadaveric study. The optic strut and its relationship to the aneurysms was well observed on the multiplanar reformats of 3D-CTA. During microsurgery, nine of ten aneurysms were verified to arise from distal to the upper surface of the optic strut. Two aneurysms that had arisen between the inferior and superior boundary of the optic strut were observed to lie within the carotid cave. One aneurysm which had arisen at the inferior boundary of the optic strut and directed inferiorly was observed to lie within the cavernous sinus just after the release of the proximal ring. Conclusion : The optic strut, as identified with multiplanar reformats of 3D-CTA, provided a reliable anatomic landmark for the proximal rings and an important information about the location of aneurysms around the anterior clinoid process (ACP). Therefore, 3D-CTA and the optic strut could become an invaluable tool and a landmark in the assessment of the location of paraclinoid aneurysms for microsurgery.

Willis환 내 뇌동맥류 진단시 전산화단층촬영 뇌혈관 조영술의 유용성 (Usefulness of Computed Tomographic Angiography in the Detection and Evaluation of Aneurysms of the Circle of Willis)

  • 이혁기;조재훈;이성락;강동기;김상철
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권3호
    • /
    • pp.345-352
    • /
    • 2000
  • Objective : The purpose of this study was to compare computed tomographic angiography(CTA) with conventional cerebral angiography(CCA) and to assess usefulness of CTA in detection and anatomic definition of intracranial aneurysms of the circle of Willis in subarachnoid hemorrhage. Patients and Methods : Fifty consecutive patients with known or suspected intracranial saccular aneurysms underwent CTA with preoperative CCA from 1997 to 1999. Using surface shaded display post-processing technique, CTA was interpreted for the presence, location of aneurysms and anatomic features. The image obtained with CTA was then compared with CCA image. Results : In 47 patients, CCA revealed 57 cerebral aneurysms and CTA revealed 54 aneurysms. Two of the 57 cerebral aneurysms were located outside of the imaging volume of CTA and one case was misdiagnosed. The sensitivity of CTA was 94.7% and the specificity was 100%. The results obtained with CTA were, compared with the results obtained with CCA, equal in determining dome shape, direction and lobularity. However, CTA provided a 3-dimensional representation of aneurysmal lesion very useful for surgical planning. Moreover, CTA was useful for rapid and relatively noninvasive detection of aneurysms in the circle of Willis. Conclusion : CTA can be a diagnostic tool for the patients with acute subarachnoid hemorrhage due to a ruptured aneurysm of the circle of Willis and provides adequate anatomic detail for surgical planning, especially to complex cerebral aneurysms. However, we think CCA is necessary because of CTA limitations including its difficulty in detecting unusually located aneurysms(including those in cavernous sinus or distal artery) and combined vascular lesion (including arteriovenous malformation) and acquiring dynamic flow information.

  • PDF

A unique case of Turner syndrome accompanying prolactinoma and unexpected elongated styloid process: Clinical and cone-beam computed tomographic features

  • Evlice, Burcu;Tatli, Ufuk;Yazicioglu, Iffet;Evlice, Ahmet;Oztunc, Haluk
    • Imaging Science in Dentistry
    • /
    • 제43권2호
    • /
    • pp.129-134
    • /
    • 2013
  • Turner syndrome (TS) is one of the most common chromosomal abnormalities, with an estimated frequency among female live births of 1/2,000-3,000. The syndrome is characterized by the partial or complete absence of one X chromosome (45,X karyotype). We reported a unique case of a 40-year-old woman with TS accompanying unexpected elongated styloid process specific to Eagle syndrome (ES) and followed up-prolactinoma. The present article is the first report to define the cone-beam computed tomographic (CBCT) features of TS accompanying ES. Patients with TS carry various risks that make treatment more complicated; thus advanced imaging techniques for proper treatment and follow-up are extremely important. In the light of CBCT examination, craniofacial abnormalities specific to TS and accompanying syndromes such as the crowding of teeth especially in the maxillary anterior region caused by maxillary narrowness, micrognatic maxilla and mandible, relative mandibular retrusion, malocclusion, open-bite, and an elongated styloid process (length of 32.7 mm) on the right side were illustrated in detail.

C2 Segmental-Type Vertebral Artery Diagnosed Using Computed Tomographic Angiography

  • Kim, Myoung Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.194-200
    • /
    • 2018
  • Objective : Sometimes a vertebral artery (VA) enters the spinal canal via the C1-2 intervertebral space, a variation regarded as a C2 segmental-type VA. This paper describes the anatomy of the C2 segmental-type VA and reviews its clinical importance. Methods : Between March 2014 and November 2015, 3386 patients underwent computed tomographic angiography. I identified C2 segmental-type VAs, associated vascular variation, the origin of ipsilateral posterior inferior cerebellar arteries (PICAs), and the clinical symptoms associated with C2 segmental-type VAs. The origin of an ipsilateral PICA is divided into 5 types. A type 1 PICA originates from ipsilateral VAs coursing suboccipitally (IVASO), a type 2 originates from ipsilateral proximal C2 segmental-type VAs, a type 3 originates from ipsilateral distal C2 segmental-type VAs. For type 4, the PICA does not originate from an ipsilateral VA. For type 5, the PICA is the terminal end of an ipsilateral C2 segmental-type VA. Results : One hundred thirteen patients had 121 C2 segmental-type VAs; 47 were associated with an IVASO, and 74 were not. Four type 1, 13 type 2, 60 type 3, 42 type 4, and two type 5 PICAs were identified. Only one patient showed symptoms associated with a C2 segmental-type VA, being a 71-year-old man presenting with a C2 segmental-type VA infarction. Conclusion : For C2 segmental-type VAs, the ipsilateral IVASO and origin of the PICA are important for predicting the outcome of this type of VA infarction.

Three-dimensional cone-beam computed tomographic sialography in the diagnosis and management of primary Sjögren syndrome: Report of 3 cases

  • Thomas, Nithin;Kaur, Aninditya;Reddy, Sujatha S.;Nagaraju, Rakesh;Nagi, Ravleen;Shankar, Vidya Gurram
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.209-216
    • /
    • 2021
  • Sjögren syndrome is a chronic autoimmune inflammatory disease characterized by lymphocytic infiltration of exocrine glands, predominantly the parotid and lacrimal glands, thereby resulting in oral and ocular dryness. It has been reported to occur most frequently in women between 40 and 50 years of age. Sjögren syndrome has an insidious onset, is slowly progressive, and presents a wide range of clinical manifestations, leading to delays or challenges in the diagnosis. Early diagnosis of this condition is essential to prevent the associated complications that affect patients' quality of life. This report presents 3 cases of Sjögren syndrome in female patients aged between 40 and 75 years who presented with complaints of persistent dry mouth and burning sensation. The cases highlight the diagnostic value of 3-dimensional cone-beam computed tomographic sialography in the detection of salivary gland pathologies at an early stage.

Cone-beam computed tomographic imaging of central giant cell granuloma: A comprehensive review

  • Tahmasbi-Arashlow, Mehrnaz;Patel, Paras B.;Nair, Madhu K.;Liang, Hui;Cheng, Yi-Shing Lisa
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.123-131
    • /
    • 2022
  • Purpose: The aim of this study was to characterize the cone-beam computed tomographic (CBCT) imaging features of central giant cell granuloma (CGCG) of the jawbone. Materials and Methods: This study retrospectively reviewed 26 CBCT studies of histologically proven cases of CGCG during a period of 20 years, from 1999 to 2019. Patients' demographic data were recorded, and radiographic features were assessed (location, border, cortication, appearance of the internal structure, locularity, septation, expansion, cortical perforation, effects on surrounding tissue, whether the lesion crossed the midline, and lesion volume). Results: In this study, CGCGs were seen almost twice as often in the mandible than in the maxilla, and 64.7% of mandibular lesions involved the anterior region. Only 26.9% of lesions crossed the midline, a feature that was considered characteristic of CGCG. Furthermore, 65.4% of lesions were unilocular and 34.6% were multilocular. The correlation between a lesion's size and its locularity was statistically significant, and larger lesions showed a multilocular appearance. The mean volume of multilocular lesions was greater than that of unilocular lesions. Conclusion: CGCGs showed variable radiographic features on CBCT, and this imaging modality is highly effective at demonstrating the radiographic spectrum and lesional extent of CGCGs in the jawbone.