• Title/Summary/Keyword: Computed Correlation

Search Result 782, Processing Time 0.031 seconds

Correlation analysis of periodontal tissue dimensions in the esthetic zone using a non-invasive digital method

  • Kim, Yun-Jeong;Park, Ji-Man;Cho, Hyun-Jae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.2
    • /
    • pp.88-99
    • /
    • 2021
  • Purpose: Direct intraoral scanning and superimposing methods have recently been applied to measure the dimensions of periodontal tissues. The aim of this study was to analyze various correlations between labial gingival thickness and underlying alveolar bone thickness, as well as clinical parameters among 3 tooth types (central incisors, lateral incisors, and canines) using a digital method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomography images and intraoral scanned files were obtained. Measurements of labial alveolar bone and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. Clinical parameters including the crown width/crown length ratio, keratinized gingival width, gingival scallop, and transparency of the periodontal probe through the gingival sulcus were examined. Results: Gingival thickness at the alveolar crest level was positively correlated with the thickness of the alveolar bone plate (P<0.05). The central incisors revealed a strong correlation between labial alveolar bone thickness at 1 and 2 mm, respectively, inferior to the alveolar crest and the thickness of the gingiva at the alveolar crest line (G0), whereas G0 and labial bone thickness at every level were positively correlated in the lateral incisors and canines. No significant correlations were found between clinical parameters and hard or soft tissue thickness. Conclusions: Gingival thickness at the alveolar crest level revealed a positive correlation with labial alveolar bone thickness, although this correlation at identical depth levels was not significant. Gingival thickness, at or under the alveolar crest level, was not associated with the clinical parameters of the gingival features, such as the crown form, gingival scallop, or keratinized gingival width.

CBCT assessment of alveolar bone wall morphology and its correlation with tooth angulation in the anterior mandible: a new classification for immediate implant placement

  • Nur Hafizah Kamar Affendi;Jumanah Babiker;Mohd Yusmiaidil Putera Mohd Yusof
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.453-466
    • /
    • 2023
  • Purpose: This study aimed to quantify alveolar bone morphology, demonstrate the relationship between tooth angulation and alveolar bone thickness, and introduce a new classification for anterior mandibular teeth related to immediate implant placement (IIP). Methods: Cone-beam computed tomography (CBCT) images of 211 anterior mandibular teeth were analyzed in sagittal slices to measure the thickness of the facial alveolar bone crest (FAB1) and apex (FAB2), and the lingual alveolar bone crest (LAB1) and apex (LAB2). Tooth angulation was classified as 1°-10°, 11°-20°, and >20° according to the tooth's long axis and alveolar bone wall. Spearman correlation coefficients were used to evaluate correlations between the variables. Results: FAB1 and LAB1 were predominantly thin (<1 mm) (84.4% and 73.4%, respectively), with the lateral incisors being thinnest. At the apical level, FAB2 and LAB2 were thick in 99.5% and 99.1% of cases, respectively. Significant differences were documented in FAB2 (P=0.004), LAB1 (P=0.001), and LAB2 (P=0.001) of all mandibular teeth. At all apical levels of the inspected teeth, a significant negative correlation existed between TA and FAB2. Meanwhile, TA showed a significant positive correlation with LAB2 of the lateral incisors and canines. These patterns were then divided into class I (thick facial and lingual alveolar bone), class II (facially inclined teeth) with subtype A (1°-10°) and subtype B (11°-20°), and class III (lingually inclined teeth) with subtype A (1°-10°) and subtype B (11°-20°). Conclusions: Mandibular anterior teeth have predominantly thin facial and lingual crests, making the lingual bone apical thickness crucial for IIP. Although anchorage can be obtained from lingual bone, tooth angulation and tooth types had an impact on IIP planning. Hence, the new classification based on TA and alveolar bone wall may enable rational clinical planning for IIP treatment.

A Study on teh Seal Indentification by using the Image Processing (영상처리에 의한 인장식별에 관한 연구)

  • 이기돈;전병민;김상운
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1984.10a
    • /
    • pp.101-103
    • /
    • 1984
  • The proposed seal identification procedure consists of the thresholding smoothing, rotation, thinning, and matching techniques. The weighted map is constructed by ditance weighted correlation CK is computed. The CK is compared with the dicision constant Cs or Cd for the purpose of seal identification.

  • PDF

Lagrangian Simulation Model of Heavy Particle Motion in a Turbulent Flow (라그랑지 관점에 입각한 난류유동장 내의 관성입자운동 모사 모델)

  • Moon, Sun;Maeng, Joo-Sung
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.241-251
    • /
    • 1991
  • The present simulation model relies on a new approach of the heavy particle motion in a turbulent flow considering the time and space correlation to the Lagrangian point of view. The turbulent field is, here, assumed that its characteristic scales are random and follow a Poisson's distribution. Using this model, we have computed the trajectory of each particle, that is, its velocity and position at each time in order to study the dispersion of particles in a grid turbulent flow. The computed results have been compared to the corresponding experimental data. Due to the complex mechanism of turbulence and the theoretically and experimentally lacking information, we had to make some assumptions for simplifying the situation, but we have found the good agreement between simulated and measured results. In particular, the application of the present method on the Lagrangian correlation of particle provides an interesting alternative to the usual computational methods.

Estimation of Lower Jaw Density using CT data

  • Jargalsaikhan, Ariunbold;Sengee, Nyamlkhagva;Telue, Berekjan;Ochirkhvv, Sambuu
    • Journal of Multimedia Information System
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • Bone density is one of the factors in the early failure of dental implants and doctors should make a preoperative assessment of jaw bone density using patient's CT data before dental implant surgery in order to find out whether the patient has osteoporosis and osteopenia. The main goal of this study was to propose a method that based on image processing techniques in order to provide accurate information about where to drill and place an abutment screw of implants in the jaw bone for doctors and reduce human activity for the estimation of the local cancellous bone density of mandible using CT data. The experiment was performed on a computed tomography data of the jaw bone of two different individuals. We assumed that the result of the estimation of jaw bone density depends on the angle of drilling and average HU (Hounsfield Unit) values were used to evaluate the quality of local cancellous bone density of mandible. As a result of this study, we have been developed a toolbox that can be used to estimate jaw bone density automatically and found a positive correlation between the angle of the drill and time complexity but a negative correlation between the diameter of the drill and time complexity.

The influence of age, sex, and tooth type on the anatomical relationship between tooth roots and the mandibular canal

  • Pucilo, Michal;Pucilo, Aleksandra;Safranow, Krzysztof;Nowicka, Alicja
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.373-382
    • /
    • 2021
  • Purpose: Cone-beam computed tomography (CBCT) reconstructions were analysed to elucidate factors affecting the anatomical relationship between tooth roots and the mandibular canal(MC). Materials and Methods: Images of 300 volumetric tomography scans of patients aged between 20 and 79 years old (167 women and 133 men) were analysed. The mean distances between 2,053 dental root apices and the internal border of the MC were obtained by measuring the horizontal and vertical distances on coronal CBCT images. The actual distance was then calculated mathematically with the Pythagorean formula. The statistical significance of differences between men and women was assessed using the Mann-Whitney test. Correlations with patient age were evaluated with the Spearman rank correlation coefficient. Results: The mean distances ranged from 2.17 mm, for single right third molar roots in women, to 8.02 mm for single left third molar mesiolingual roots in men. The mean distances measured for the mandibular right second molar mesial roots and the right second premolar roots were larger in men than in women. Age showed a significant positive correlation with the measured distances for mesial and distal roots of the first and second molar on both sides and the right third molar, mesiolingual roots of the left third molar, and single roots of the right third molar. Conclusion: The root-to-mandibular canal distance depended on age and the type of tooth. In 2 root types, this distance was impacted by sex.

Bone density around the fixture after function of implant molar prosthesis using CBCT (임플란트 보철 기능후 고정체 주변 콘빔CT 골밀도 평가)

  • Jung, Jae-Hyun;Hwang, In-Taik;Jung, Byung-Hyun;Kim, Jae-Duk;Kang, Dong-Wan
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose : The purpose of this study was to examine the significance of increased bone density according to whether bone grafts were applied using demographic data with Cone Beam Computed Tomography (CBCT) and to compare the bone densities between before and after implant prosthesis using the Hounsfield index. Materials and Methods : Thirty-six randomly selected computed tomography (CT) scans were used for the analysis. The same sites were evaluated digitally using the Hounsfield scale with V-Implant $2.0^{TM}$, and the results were compared with maxillary posterior bone graft. Statistical data analysis was carried out to determine the correlation between the recorded Hounsfield unit (HU) of the bone graft and implant prosthesis using a Mann-Whitney U test and Wilcoxon Matched-pairs test. Results : The bone grafted maxillary posterior teeth showed an increase in the mean values from-157 HU to 387 HU, whereas non-grafted maxillary posterior teeth showed an increase from 62 HU to 342 HU. After implantation, the grafted and non-grafted groups showed significantly higher bone density than before implantation. However, the grafted group showed significantly more changes than the non-grafted group. Conclusion : Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density (Hounsfield scale) and bone grafts in the maxillary molar area.

Retrospective study on the airway obstruction aspects of computed tomography and lateral cephalometry and the correlation of polysomnography in obstructive sleep apnea patients

  • Jin, Sun-Mi;Lee, Hye-Sung;Ryu, Hyun-Ho;Ryu, Seok-Hwan;Shin, Dong-Yoon;Kim, Chul-Hoon;Kim, Myoung Soo;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.5
    • /
    • pp.295-304
    • /
    • 2012
  • Objectives: Lateral cephalometry, computed tomography (CT) and full-night polysomnography were used to examine the correlation of obstructive sleep apnea (OSA) severity. Materials and Methods: A total of 29 patients (5 females, 24 males) diagnosed with OSA were evaluated by lateral cephalometry, CT and full-night polysomnography. Lateral cephalometry was performed in the closed and open mouth states. The radiographic and polysomnography measurements of the patients with OSA were evaluated statistically to determine the association with OSA severity. Results: A significant relationship was observed between the increased respiratory disturbance index and closing lateral cephalometry. With mouth opening, the airway space narrowed and the OSA worsened. Lateral cephalometry revealed OSA patients to have an inferiorly positioned hyoid bone, longer-than-normal soft palate and narrowing airway space. As OSA was severe, the airway shape was ovoid in the CT horizontal view. Conclusion: Polysomnography and the radiographic parameter can be used for diagnosing OSA.

Needling Depth of Cheonchu(ST25) with Computed Tomography: a Retrospective Study (Computed Tomography를 통한 천추(ST25)의 자침 깊이에 대한 후향적 연구)

  • Park, Hae In;Yang, Hyun Jung;Park, Sang Kyun;Lee, Kwang Ho
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.61-67
    • /
    • 2015
  • Objectives : The aim of this study is to investigate the safe needling depth of Cheonchu($ST_{25}$) retrospectively by using an abdomen abdomen computed tomography(CT), and to analyze the correlation between needling depth and the characteristics of the subjects. Methods : We marked spots 50 mm away from both sides of the umbilicus in the abdomen CT and measured the vertical distance to the parietal peritoneum from the skin surface as well as waist circumference. Correlations between measured depth of Cheonchu($ST_{25}$) and variables such as age, gender and waist circumference were analyzed. Results : Average depth of the Cheonchu(n = 90) was $3.21{\pm}0.87cm$, the minimum was 1.31 cm and the maximum was 5.63 cm. A definite positive correlation was noted between needling depth and waist circumference and a significant difference was observed in needling depth according to waist circumference groups. Conclusions : Needling depth of Cheonchu($ST_{25}$) varied depending on the patient's waist circumference; safe needling depth of Cheonchu($ST_{25}$) measured by abdomen CT is 1.31~5.63 cm.

Osteoporosis prediction from the mandible using cone-beam computed tomography

  • Barngkgei, Imad;Haffar, Iyad Al;Khattab, Razan
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.263-271
    • /
    • 2014
  • Purpose: This study aimed to evaluate the use of dental cone-beam computed tomography (CBCT) in the diagnosis of osteoporosis among menopausal and postmenopausal women by using only a CBCT viewer program. Materials and Methods: Thirty-eight menopausal and postmenopausal women who underwent dual-energy X-ray absorptiometry (DXA) examination for hip and lumbar vertebrae were scanned using CBCT (field of view: $13cm{\times}15cm;$ voxel size: 0.25 mm). Slices from the body of the mandible as well as the ramus were selected and some CBCT-derived variables, such as radiographic density (RD) as gray values, were calculated as gray values. Pearson's correlation, one-way analysis of variance (ANOVA), and accuracy (sensitivity and specificity) evaluation based on linear and logistic regression were performed to choose the variable that best correlated with the lumbar and femoral neck T-scores. Results: RD of the whole bone area of the mandible was the variable that best correlated with and predicted both the femoral neck and the lumbar vertebrae T-scores; further, Pearson's correlation coefficients were 0.5/0.6 (p value=0.037/0.009). The sensitivity, specificity, and accuracy based on the logistic regression were 50%, 88.9%, and 78.4%, respectively, for the femoral neck, and 46.2%, 91.3%, and 75%, respectively, for the lumbar vertebrae. Conclusion: Lumbar vertebrae and femoral neck osteoporosis can be predicted with high accuracy from the RD value of the body of the mandible by using a CBCT viewer program.