• 제목/요약/키워드: Compressor case

검색결과 157건 처리시간 0.026초

CFD를 이용한 피트의 지중열 모델 구축에 관한 연구 (A Geothermal Model of Pit Area Using Computational Fluid Dynamics)

  • 민준기;김정태
    • KIEAE Journal
    • /
    • 제8권5호
    • /
    • pp.11-16
    • /
    • 2008
  • This research has established CFD model on pit's cool-tube system through heat and air movement simulations, of which data was based on experimental and verification. This research work verified the effectiveness of the cool-tube system by analysing temperature, humidity and air current of the actually installed case. Also, we analysed heat transfer through air current simulation and the results are as followings. Firstly, we experiment on temperature, humidity and speed of air currents of the cool tube system with pit space during the month of May (spring). The average exterior temperature was $16.1^{\circ}C$, and $18.2^{\circ}C$ for the pit, $24.7^{\circ}C$ for the compressor room. Secondly, based on measured data of real case, we have analysed heat transfer through air current simulation and verified our proposed model. The actual measurement of average temperature of exhaust air of the pit's area is $19.7^{\circ}C$ with tolerance of $-0.33^{\circ}C{\sim}-0.6^{\circ}C$ compared to above simulations. Thirdly, having verified air current simulation model with formation of 260,000 and 1,000,000 cells, we could get reasonable near values with 260,000 cells. Lastly, the next step of research would be focused on proposing the best possible pit's cool-tube system after analysis of heat transfer of the air current simulation based on verified CFD model.

스크류 로터 치형의 성능해석에 관한 연구 (A Study on performance analysis of screw rotor profiles)

  • 최상훈;김동현
    • 한국정밀공학회지
    • /
    • 제13권1호
    • /
    • pp.69-77
    • /
    • 1996
  • To design high-effective profile in screw rotor profile using in screw compressor, we design the symmetric type changing the number of lobes and the non-symmetric type changing the neighbourhood of the top point of lobe. Then, we calculated the performance value of profile according to the scale of these non-symmetric's wrap angle. We had the results as follows. 1. About the non-symmetric case, the larger a wrap angle is the shorter seal line is and the smaller blow hole is, thus we know what the large wrap angle profile is better than the small one. 2. We know what the non-symmetric profile is better than the symmetric profile in the result of the compare of seal line's length, blow hole's area, volume curve. 3. About the non-symmetric case, the deformation of the neighbourhood of lobe's top point of the rotor profile has a large effect upon the increase of performance because the length of seal line became short and the area of blow hole is small.

  • PDF

첨가제에 의한 PTFE 복합재료의 마찰마모 특성에 관한 연구 (A Study on the Effects of Additives on the Friction and Wear Properties of PTFE Composite)

  • 김용직;김윤해
    • Composites Research
    • /
    • 제13권4호
    • /
    • pp.11-18
    • /
    • 2000
  • 본 연구는 공기압축기에 적용되는 피스턴링의 재료에 자기윤활성 재료를 이용할 경우 어떠한 마찰마모 특성을 나타내는가를 비교평가 함으로써 실제 적용여부의 가능성을 확인하였으며, 주요 결과로는 동을 중량비 30% 함유한 시험편이 평균마찰계수 및 비마모량이 가장 적었다. 이는 마찰계수에 직접적인 영향을 주는 마모유동막이 조기에 다량 생성될 경우 낮은 마찰계수와 함께 안정화 효과에 큰 영향을 주며 비마모량은 발생된 마모유동막의 경도와 비례하고 용융마모에 의해 덩어리 형태로 탈락되는 마모분이 가장 적기 때문이라고 생각된다.

  • PDF

HFC32 냉매를 사용한 지열원 히트펌프의 성능 특성 (Performance of the Geothermal Heat Pump Using HFC32 Refrigerant)

  • 박용정;박병덕
    • 한국수소및신에너지학회논문집
    • /
    • 제30권4호
    • /
    • pp.369-375
    • /
    • 2019
  • Air conditioners adopting high energy efficiency and low global warming potential (GWP) refrigerant are being developed globally. In case of commercial air conditioner, R32 with lower GWP than R410A is attracting industrial attentions. In this study, the performance of water-to-water geothermal heat pump adopting R32 is compared with that of the heat pump using R410A. By using R32 instead of R410A, heating capacity and COP in heating standard condition can be increased by 8.8% and 6.3% respectively. Also, cooling capacity and COP in cooling standard condition can be increased by 5.3% and 3.1% respectively by using R32. But in case of using R32, systemic improvements are required to decrease discharge temperature of compressor since discharge temperature rises abnormally in heating operations.

안정한 엔진 공회전 모드를 위한 제어기 설계 (Controller Design for Stable Engine Idle Mode)

  • 이영춘;방두열;이성철
    • 한국정밀공학회지
    • /
    • 제17권6호
    • /
    • pp.89-95
    • /
    • 2000
  • The engine idle speed mode becomes worse as one drives a vehicle for several years. This is due to ageing of engine and power-train parts. In this case, unstable idle conditions such as engine stall and droop are frequently experienced when the engine gets heavy torque loads due to power steering pump and air conditioning compressor. The objective of this paper is to study on the idle speed control using PID controller under load disturbances. The input of the PID controller is an error of rpm. The output of the PID controller is an ISCV duty cycle. The dSPACE Controller Boards are used to interface with engine. The on-vehicle test is realized using by SIMULINK and BLOCKSETS tools. The real time interface control panel supplied by Control Desk S/W is designed to have good results in engine idle speed control.

  • PDF

약계자 영역에서 PMSM 드라이브의 최대 토크제어 (Maximum Torque Control of PMSM Drive in Field weakening Region)

  • 이홍균;이정철;김종관;정동화
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.44-49
    • /
    • 2003
  • Permanent magnet synchronous motor(PMSM) is widely used in many applications such as an electric vehicle. compressor drives of air conditioner and machine tool spindle drives. PMSM drive system have become a popular choice in various application, due to their excellent power to weight ratio. This paper is proposed maximum torque control for field weakening operation of PMSM drive. At low speeds, the reluctance torque is used to maximize the output for a given current level. This is achieved maximum torque per ampere(MTPA) by selecting an optimal value of the direct stator current component. At high speeds, the system reaches a point at which the inverter will not be able to supply the desired voltage. In this case it is necessary to make use of an increased value the direct current component. The proposed control algorithm is applied to PMSM drive system, the operating characteristics controlled by maximum torque control are examined in detail by simulation.

혼합냉매를 사용한 열펌프의 성능해석 (II) (Performance Analysis of a Heat Pump Using Refrigerant Mixtures (II))

  • 김민수;김동섭;원성필;노승탁
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.218-225
    • /
    • 1990
  • Studies on the performance of a heat pump using non-azeotropic refrigerant mixtures are done. In order to estimate the thermodynamic properties for the selected non-azeotropic refrigerant mixtures including R22/R152a, R22/R142b, R22/R114 and R13B1/R152a, Peng-Robinson equation of state is adopted. The pressure-enthalpy diagram and the temperature-entropy diagram are plotted for each refrigerant mixture. Considerations on the capacity modulation for the heat pump system using refrigerant mixtures are taken into. Results show that when the heating load varies, the possibility for the capacity modulation is found in the heat pump system using a compressor with constant volume flow rate. Under a constant heating capacity condition in the heat pump system, the coefficient of performance increases when the refrigerant mixtures are used. The volume flow rate decreases as the mass fraction of lower boiler increases in this case.

  • PDF

전문가시스템을 기반으로 한 통합기계상태진단 알고리즘의 구현(I) (Implementation of an Integrated Machine Condition Monitoring Algorithm Based on an Expert System)

  • 장래혁;윤의성;공호성;최동훈
    • Tribology and Lubricants
    • /
    • 제18권2호
    • /
    • pp.117-126
    • /
    • 2002
  • Abstract - An integrated condition monitoring algorithm based on an expert system was implemented in this work in order to monitor effectively the machine conditions. The knowledge base was consisted of numeric data which meant the posterior probability of each measurement parameter for the representative machine failures. Also the inference engine was constructed as a series of statistical process, where the probable machine fault was inferred by a mapping technology of pattern recognition. The proposed algorithm was, through the user interface, applied for an air compressor system where the temperature, vibration and wear properties were measured simultaneously. The result of the case study was found fairly satisfactory in the diagnosis of the machine condition since the predicted result was well correlated to the machine fault occurred.

냉장고 기계실 축류홴 소음의 수치적 연구 (Numerical study on the machine room axial flow fan of a refrigerator)

  • 전완호;김욱;신대식;김현주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1002-1006
    • /
    • 2006
  • The noise of a refrigerator is consisted of the various flow noises of a refrigerator fan, a compressor and a condenser fan. The demands of high flow rate, compact space and low noise are to be accommodated, especially, in the case of a premium refrigerator. In this study, flow field, noise sources and flow noise are analyzed numerically and compared to the measured data. The flow field is calculated with 3-dimensional CFD solver - SC/Tetra, and the noise source and aeroacoustic noise is analyzed with FlowNoise S/W. Low noise axial fan can be developed by controlling the dominant noise source area.

  • PDF

착상을 수반한 멀티 가변속 열펌프의 동특성 (A Dynamic Characteristic of the Multi-Inverter Heat Pump with Frosting)

  • 박병덕;이주동;;황일남;장세동;황정하
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.337-345
    • /
    • 2003
  • In the case of heat exchangers operating under frosting condition, the growth of frost layer causes the heat exchanger to increase the thermal resistance and pressure loss of the air flow. In this paper, a transient characteristic prediction model of the heat transfer for multi inverter heat pump with frosting on its surface was presented taking into account the change of the fin efficiency due to the growth of the frost layer. In this dynamic simulation program, which was peformed for a basic air conditioning system model, such as evaporator, condenser, compressor, linear electronic expansion valve (LEV) and bypass circuit. The theoretical model was driven from the obtained heat transfer coefficient and mass transfer coefficient, independently. And we consider heat transfer performance was only affected by a decrease of the wind flow area. The calculated results were compared with some cases of experiments for frosting conditions.