• Title/Summary/Keyword: Compressor Vibration

Search Result 330, Processing Time 0.029 seconds

A Study on the Severity Control of Unpaved Test Courses (비포장 노면의 가혹도 관리에 관한 연구)

  • Yang, Jin-Saeng;Goo, Sang-Hwa;Lee, Jeong-Hwan;Kang, Do-Kyoung;Lee, Sang-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.47-57
    • /
    • 2007
  • The vibration environment essentially companied by vehicle operation on the road is determined by the shape of road surface, which is called profile. In general, the profile and severity of unpaved road is an important issue in the reliability of durability test for vehicles. In order to maintain severity of unpaved road, it is necessary to develop profilometer system. We developed profilometer system which is composed of data processing computer, power unit, air compressor and sensors. This paper focuses on the severity management of unpaved test courses using neural networks. This paper presents the maintenance range for cross-country course in CPG(Chang-won Proving Ground) and the evaluation of similarity degree between unpaved roads.

Condition Monitoring Technology for Plant Machinery system Based on Integrated Wear Monitoring (마모발생의 통합 분석을 통한 대형 기계 윤활 시스템의 상태진단기술 적용)

  • 윤의성;장래혁;공호성;한흥구;권오관;송재수;김재덕;엄형섭
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.191-199
    • /
    • 1997
  • Condition monitoring technology was applied for an air compressor lubricating system to achieve a proactive maintenance, which could prevent a catastrophic failure and detect root causes of the conditional failure of the system. For this work, various types of wear monitoring technology were used and compared with the results of vibration and temperature measurements. Results generally showed that every technology has a limitation to failure detection, and integrated-based condition monitoring should be performed for the best results. In this work, an idea for the implementing integrated wear monitoring was suggested and demonstrated.

  • PDF

Implementation of an Integrated Machine Condition Monitoring Algorithm Based on an Expert System (전문가시스템을 기반으로 한 통합기계상태진단 알고리즘의 구현(I))

  • 장래혁;윤의성;공호성;최동훈
    • Tribology and Lubricants
    • /
    • v.18 no.2
    • /
    • pp.117-126
    • /
    • 2002
  • Abstract - An integrated condition monitoring algorithm based on an expert system was implemented in this work in order to monitor effectively the machine conditions. The knowledge base was consisted of numeric data which meant the posterior probability of each measurement parameter for the representative machine failures. Also the inference engine was constructed as a series of statistical process, where the probable machine fault was inferred by a mapping technology of pattern recognition. The proposed algorithm was, through the user interface, applied for an air compressor system where the temperature, vibration and wear properties were measured simultaneously. The result of the case study was found fairly satisfactory in the diagnosis of the machine condition since the predicted result was well correlated to the machine fault occurred.

Study on the vibration control acaused by unbalance force for a W-type air compressor (W형 공기압축기의 불평형진동 저감에 관한 연구)

  • Kim, Yeong-Ju
    • 연구논문집
    • /
    • s.28
    • /
    • pp.145-159
    • /
    • 1998
  • 선박이나 산업플랜트에 이용되고 있는 압축공기의 압력이 증가되고 압축기의 경량화 내지는 설치면적을 축소하기 위하여 3단압축을 하므로서 토출압력을 30기압 이상으로 증가할 수가 있다. 그러나 크랭크기구를 갖고있는 공기압축기의 실린더 배열이 복잡하고 고속운전으로 인하여 크랭크축에 연결된 왕복질량과 회전질량에 의한 불평형력이 저감되도록 왕복질량의 적절한 배치와 중량감소를 위해 주철재 피스톤 재질을 알미늄합금으로 교체하고 적절한 평형추 설치와 방진고무의 선택을 검토해야한다. 본 연구에서는 3개의 실린더가 60도 간격으로 배치되는 W형 공기압축기의 진동상태를 측정하고 이를 분석하여 진동저감을 위한 대책으로 평형추 계산이론을 도출하는데 중점을 두었다. 검토대상 공기압축기의 사양은 표1에 보이는 바와 같다.

  • PDF

Forced Vibration and Structural Response Prediction for Impeller in Resonant Conditions due to Diffuser Vanes (디퓨저 베인에 기인한 공진조건에서의 임펠러 강제진동 및 구조응답 예측)

  • Kim, Yongse;Kong, Dongjae;Shin, SangJoon;Park, Kihoon;Im, Kangsoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.24-35
    • /
    • 2018
  • Impeller blades in the centrifugal compressor are subjected to periodic aerodynamic excitations by interactions between the impeller and the diffuser vanes (DV) in resonant conditions. This may cause high cycle fatigue (HCF) and eventually result in failure of the blades. In order to predict the structural response accurately, the aerodynamic excitation and the major resonant conditions were predicted using unsteady computational fluid dynamics (CFD) and structural analysis. Then, a forced vibration analysis was performed by going through one-way fluid-structure interaction (FSI). A numerical analysis procedure was established to evaluate the structural safety with respect to HCF. The numerical analysis procedure proposed in this paper is expected to contribute toward preventing HCF problems in the initial design stage of an impeller.

Development of Turbo Expanders with Hydrostatic Bearings for Hydrogen Liquefaction Plants (정압 베어링을 적용한 수소 액화 공정용 터보 팽창기 개발)

  • Lee, Donghyun;Kim, Byungock;Park, Mooryong;Lim, Hyungsoo
    • Tribology and Lubricants
    • /
    • v.37 no.3
    • /
    • pp.91-98
    • /
    • 2021
  • This paper presents a hydrostatic bearing design and rotordynamic analysis of a turbo expander for a hydrogen liquefaction plant. Th~e turbo expander includes the turbine and compressor wheel assembled to a shaft supported by two hydrostatic radial and thrust bearings. The rated speed is 75,000 rpm and the rated power is 6 kW. For the bearing operation, we use pressurized air at 8.5 bar as the lubricant that is supplied to the bearing through the orifice restrictor. We calculate the bearing stiffness and flow rate for various gauge pressure ratios and select the orifice diameter providing the maximum bearing stiffness. Additionally, we conduct a rotordynamic analysis based on the calculated bearing stiffness and damping considering design parameters of the turbo expander. The predicted Cambell diagram indicates that there are two critical speeds under the rated speed and there exists a sufficient separation margin for the rated speed. In addition, the predicted rotor vibration is under 1 ㎛ at the rated speed. We conduct the operating test of the turbo expander in the test rig. For the operation, we supply pressurized air to the turbine and monitor the shaft vibration during the test. The test results show that there are two critical speeds under the rated speed, and the shaft vibration is controlled under 2.5 ㎛.

Study on the Modal Test for a Turbocharger Wheel Using Vibro-acoustic Responses (진동 방사음을 이용한 터보차져 휠 동특성 시험에 대한 고찰)

  • Lee, Hyeong-Ill;Lee, Dug-Young;Park, Ho-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.29-37
    • /
    • 2011
  • The modal characteristics of a compressor wheel of an automotive turbocharger have been investigated using an experimental method based on an acoustic frequency response function, p/f(${\omega}$), where p is sound pressure radiated from a structure, and f is impact force. First, a well-defined annular disc with narrow radial slots was examined to check whether the vibro-acoustic test could precisely determine natural quencies and vibration modes of structures showing that the vibro-acoustic test proposed in this paper was comparable to the conventional modal test with an accelerometer and the numerical analysis. The conventional method has been found to be inappropriate for compressor wheel because of additional mass due to the accelerometer and additional damping from the accelerometer cable alter the dynamic responses of the wheel blades. odal characteristics of the wheel have been defined using vibro-acoustic test and verified with the results from another conventional method using a laser vibrometer. Natural quencies and mode shapes of a turbocharger wheel, which can't be precisely obtained with onventional method, could be defined accurately without the additional effects from sensor and cable. Proposed method can be applied to small structures where conventional sensors and cables could generate troubles.

Fault Classification Model Based on Time Domain Feature Extraction of Vibration Data (진동 데이터의 시간영역 특징 추출에 기반한 고장 분류 모델)

  • Kim, Seung-il;Noh, Yoojeong;Kang, Young-jin;Park, Sunhwa;Ahn, Byungha
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.1
    • /
    • pp.25-33
    • /
    • 2021
  • With the development of machine learning techniques, various types of data such as vibration, temperature, and flow rate can be used to detect and diagnose abnormalities in machine conditions. In particular, in the field of the state monitoring of rotating machines, the fault diagnosis of machines using vibration data has long been carried out, and the methods are also very diverse. In this study, an experiment was conducted to collect vibration data from normal and abnormal compressors by installing accelerometers directly on rotary compressors used in household air conditioners. Data segmentation was performed to solve the data shortage problem, and the main features for the fault classification model were extracted through the chi-square test after statistical and physical features were extracted from the vibration data in the time domain. The support vector machine (SVM) model was developed to classify the normal or abnormal conditions of compressors and improve the classification accuracy through the hyperparameter optimization of the SVM.

밀폐형 압축기의 소음진동에 대한 연구 예와 시급한 연구과제에 관하여

  • 김종혁
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.17-24
    • /
    • 1998
  • 압축기의 종류는 크게 dynamic type과 positive displacement type으로 우선 나눌 수 있다. 전자는 제트엔진에 사용되는 압축기에서 보는 바와 같이 기체의 속도를 변화시켜 동압을 정압으로 바꾸어 압력을 얻는 경우이다. 후자는 기체를 둘러싼 체적을 줄여서 압력을 얻는데 가전제품에 쓰이는 냉각용 압축기의 대부분의 종류가 이에 해당된다. 압축 기체의 종류에 따라 공기 압축기, 가스 압축기, 냉각용 압축기로도 나눌 수 있겠다. 냉각용 압축기는 다시 여러 가지 방법으로 분류할 수 있겠지만, 구동 모타의 용량이나 냉각 용량에 따라, 대형, 소형으로 분류하거나, 압축기를 둘러싼 셀의 구조에 따라 밀폐형과 반 밀폐형으로 나눌 수 있다. 밀폐형은 냉매를 반 영구적으로 보충할 필요가 없도록 용접형 셀을 가진 구조로 압축기를 다시 열어서 보수할 수가 없다. 냉장고나 냉방기 같은 가전 제품에 쓰이는 압축기는 대부분 소형 밀폐형이 되겠다. 산업용의 중,대형 압축기는 보수의 목적으로, 자동차 냉방용 압축기는 동력이 엔진축에서 공급되는 구조 상의 이유로 반 밀폐형이 채택된다. 보수가 사실상 불가능한 밀폐형의 구조 상 소형 냉장용 압축기는 거의 무한 수명을 감안한 설계를 요하게 되고, 이것이 압축기의 보수적인 설계 및 개발 성향에 어느 정도 영향을 주었다고 볼 수 있다. 이런 소형 밀폐형 압축기(positive displacement, fractional horsepower, hermetic compressor)에 관한 연구의 소개가 이 글의 주 관심이 되겠다. 압력을 얻기 위해 체적을 변화시키는 mechanism도 여러 가지가 있는 바, 왕복동식 피스톤(reciprocating piston) 압축기가 가장 오랫동안 사용되어 온 구조이다. 회전식으로 압축을 얻는 방식으로는 로타리 피스톤식, 스크류식, 스크롤식 압축기가 있다. 로타리 피스톤(rotary piston)식 압축기는 약 20여년 전 부터 냉방용 압축기에서부터 널리 쓰이게 되었다. 약 10여년전부터 상용화 된 스크롤(scroll) 형 압축기도 현재 상대적으로 용량이 큰 가정용 냉방기를 중심으로 많이 쓰이고 있다. 스크류형 압축기는 보통 중대형 상업용에 주로 쓰인다.

  • PDF

Psychoacoustical Study for Sound Quality Index of Steady State Noise of Refrigerators (냉장고 정상상태 소음의 음질 인덱스 개발을 위한 심리음향학적 연구)

  • Kong, Kyung-Soo;Jung, Weui-Bong;Kim, Tae-Hoon;Shin, Dae-Sik;Ahn, Se-jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.536-545
    • /
    • 2016
  • Household refrigerator radiates noise of which the pattern is dependent on the operating condition of its parts, such as compressor, flow fans, etc. Thus the refrigerator noise has a variety of frequency characteristics. Therefore, it is required to consider the noise characteristics for evaluating the noise quality and eventually developing the sound quality index of the refrigerator noise. In this study, five units of household refrigerator were selected to measure their noises that were used to generate sound sources for jury test of the study. The measured noises of five refrigerators were divided into ten kinds of sound source by considering operating condition and frequency characteristics. Additionally, the ten sources were each edited to have the same SPL of 30 dBA. Totally twenty kinds of sound sources (10-original SPL, 10-edited SPL 30 dBA) were evaluated by twenty-two subjects, and compared with their sound quality metrics. It was found that only the loudness of the metrics was meaningfully correlated with the subjective evaluation. The rests, sharpness, roughness and fluctuation strength, were not related. The conclusion of this study is that a new sophisticated index is necessary to be developed to qualitatively evaluate the household refrigerator noise.