• Title/Summary/Keyword: Compressor System

Search Result 1,075, Processing Time 0.028 seconds

An Analysis of the Performance of a Combined Expander-Compressor Unit for a CO2 Automotive Air Conditioning Cycle (차량용 CO2 에어컨 사이클 성능 향상을 위한 일체형 팽창기-압축기 성능 해석)

  • Choi, Jae Woong;Lim, Jeong Taek;Kim, Hyun Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.107-115
    • /
    • 2018
  • A design combining the use of a compressor and expander was introduced in order to improve the cycle performance of a $CO_2$ automotive air conditioning system. Both the compressor and expander used were of rotary vane type and were designed to share a common shaft in a housing. Numerical simulation was carried out to evaluate the merit of the combined unit. In a typical automotive air conditioning operating conditions, the COP of the system was improved by 8.7% by the application of the combined unit. The compressor input was reduced by 5.2% through use of the expander output. In addition, about 3.06% increase in the cooling capacity was obtained through isentropic expansion in the expander. Our study noted that, as the pressure difference between the gas cooler and the evaporator becomes larger, the COP of the system improved increases unless the mass flow rate in the expander exceeds that in the compressor.

A Study on the Micro Vapor Compressor based on Microfabrication Process for the Application to the Micro Miniature Refrigeration System (초소형 냉동시스템의 응용을 위한 마이크로 증기 압축기의 개발 및 성능에 관한 연구)

  • Yoon, Jae-Sung;Choi, Jong-Won;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.477-482
    • /
    • 2006
  • In this study, a micro vapor compressor has been designed, fabricated and tested. The micro vapor compressor was made of silicon substrates and fabricated by micromachining process. The compressor is driven by a piezoelectric actuator which is widely used in microfluidic systems because of its strong force and rapid response. The actuator is a bimorph structure which consists of a silicon membrane and a piezoelectric ceramic film. A simulation work was conducted on the performance characteristics of the compressor. The simulation investigated the flow rate variation under various back pressure conditions. Experimental works were carried out on the operation of a compressor and the test results were compared with the simulation results.

  • PDF

Experimental Study on Effects of Compressor for Automotive Air Conditioning System on Fuel Economy (차량용 에어컨 압축기가 실차 연비에 미치는 영향에 관한 실험적 연구)

  • Yoo, Seong-Yeon;Kim, Young-Shin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • In this study, the effects of the compressor for the air conditioning system on the fuel economy were experimentally investigated in an actual automobile. This study aims to analyze the level of contribution of the driving torque of the compressor to the fuel economy. A torque sensor, which is directly set on the clutch of the compressor, is developed to obtain data about the compressor load, which influences the fuel efficiency, and then, the reliability of the torque sensor is verified by comparing the results with those of a torque meter in a bench test. An actual automobile equipped with the compressor and torque sensor is operated in a climate wind tunnel in which appropriate facilities are set up to evaluate the fuel efficiency. The compressor driving torque resulting from the difference in the compressor displacement is found to influence the fuel economy, and the fuel economy is found to be worsened by up to 2~3% with an around 11% increase in the compressor displacement under the same conditions.

Correlation on Compressor Discharge Temperature of System A/C Applying PWM Scroll Compressor in Cooling Mode (PWM 스크롤압축기를 적용한 시스템 에어컨의 냉방운전 시 압축기 토출온도에 대한 상관식 개발)

  • Kwon, Young-Chul;Park, Sam-Jin;Ko, Kuk-Won;Park, Byung-Kwon;Kim, Dae-Hun;Youn, Baek
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.154-159
    • /
    • 2006
  • An experimental study has been performed to investigate the correlation on compressor discharge temperature of capacity modulated system A/C in cooling mode. Indoor and outdoor temperatures, the cooling capacity, compressor discharge temperature and loading time are measured by the psychrometric calorimeter. The system is controlled by applying the scroll compressor operated by PWM valve and loading duty. With decreasing outdoor temperature, the cooling capacity increases. But, with decreasing indoor temperature, it decreases. According to the increase in outdoor temperature and loading duty, compressor discharge temperature increases. From these experimental data, the correlation on compressor discharge temperature is proposed. The correlation obtained from the present study is agreed with the experimental data within $3^{\circ}C$.

Performance Comparison of Hot-gas Bypass Types with the Variation of Refrigeration Load (부하변화에 따른 hot-gas 바이패스 방식별 성능 비교)

  • Baek, Seung-Moon;Yoon, Jung-In;Son, Chang-Hyo;Heo, Jung-Ho
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.48-54
    • /
    • 2014
  • In this paper, three refrigeration systems bypassing hot-gas to compressor outlet, compressor and condenser outlet and evaporator inlet are theoretically compared to offer basic design data for performance depending on cooling load using a HYSYS program. The main results are summarized as follows : First, the COP of third system is the highest. Next, the COP of second system is higher than first one. And, the temperature of compressor inlet of third system is constant for all cooling load. Compared to first and second system, the compressor inlet temperature of the first system is higher than second one for all cooling loads. From the above results, third system, which is bypassing hot-gas to evaporator inlet, is more advantageous when considering the precise temperature control and excellent performance of oil and water cooler of industrial machine.

Development of Neon Compressor for Reverse Brayton Cryocooler (극저온 냉동기용 냉매압축기의 개발)

  • Kim, Seungwoo;Park, Kicheol;Lee, Kiho;Kim, Kyungsoo;Kim, Dongkwon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.237-243
    • /
    • 2002
  • A centrifugal compressor of 50HP for reverse brayton cryocooler using neon as a coolent has been developed. It has relatively low total-to-total pressure ratio but mass flow rate is very small and the voting gas, neon, has greater specific heat ratio than air. It was essential to have very high rotational speed of 100,000 RPM. The efficiency of compressor has great effects on overall system and the COP of cryocooler. To meet the design requirement of the compressor efficiency and to minimized the required rotational speed, highly efficiency impeller having low specific speed was designed. To maintain the overall system efficient high, gas bearing of bump type and high speed permanent magnet synchronus motor was developed and adopted. In this paper, design and performance prediction results of the compressor impeller is presented.

  • PDF

Development of the Turbo Compressor for a Geothermal Heat-Pump System (지열 히트 펌프시스템용 터보 압축기 개발)

  • Park, Jun-Young;Park, Moo-Ryong;Choi, Sang-Gu;Yoon, Eui-Soo;Hwang, Soon-Chan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1395-1400
    • /
    • 2004
  • A centrifugal compressor for geothermal heat pump system using R134a as working fluid has been developed. The centrifugal compressor consists of an impeller with splitters, two vaneless diffuser, a low solidity vaned diffuser and a volute. In this compressor, diffuser blade angles are controlled to satisfy both heating and cooling conditions. A aerodynamic design was done by applying the repeating design procedure including a meanline design, a 3D geometry generation and fluid dynamic calculation. In this paper, design and performance prediction results of the compressor are presented.

  • PDF

An Optimum Design of the Compressor Wheel and the Rotor-Bearing System of a Two-Stage Compressor (이단 압축기의 임펠러 및 시스템에 대한 최적설계)

  • Lee, Yong-Bok;Kim, Jong-Rip;Choi, Dong-Hoon;Kim, Kwang-Ho;Kim, Chang-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.129-134
    • /
    • 2001
  • The paper presents the optimal design of a oil-free two-stage compressor, which is driven by 75 kW motor at an operating speed of 39,000 rpm, and the pressure ratio of which is up to 4. First, an attempt is made to obtain the optimal design of a bump bearing which supports a compressor rotor. Second, bump bearings and shaft are considered simultaneously, and the weighted sum of rotor weight and frictional torque is minimized. Finally, the optimal geometry of compressor wheel is considered. The mean efficiency and the - minimum efficiency are maximized respectively. The results presented in this paper provide important design information necessary to reduce the energy loss.

  • PDF

Detailed Design for 25bar-class Biogas Compression Supplying System (25BAR급 바이오가스 고압 압축공급시스템 상세설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yun, Eun-Young;Lee, Jung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.173.1-173.1
    • /
    • 2011
  • The high fuel flexibility of gas turbine power system has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and sewage waste water as a fuel for gas turbines has increased. We investigated the performance of high pressure biogas compression system and operating conditions for supplying biogas. The total flow per minute of biogas from food waste water digestion tank is $54Nm^3$. The main type of biogas compression system is the reciprocating system and screw type system. The target of biogas mechanical data is the as belows; inlet pressure 0.045bar, supplying biogas temperature is $30{\sim}60^{\circ}C$, and final pressure is above the 25 bar. Also, inlet conditions of biogas consist of CH4 48.5%~83%, $H_2S$ Max. 500ppm, $NH_3$ Max. 1,500ppm and Siloxane 2.7~4.6ppm. The boosting Blower system raises a pressure from 0.045bar to 1bar before main compressor. The main system lay out of reciprocating consisits of compressor driver, filter, cooling system, blowdown vessel, control system and ESD(Emergency Shut Down) system. And an enclosure package needs to be installed for reducing noise up to 75dB. The system driver is the electronic motor of explosion proof type. Forthe compressor system reliable operation, the cleaning system something like particulate filter needs to be set up in the inlet of compressor and Coalescing Filter in the outlet of compressor. Particulate Filter has to be removed above $10{\mu}m$ size of the particles in biogas. The coalescing filter(Micofine Borosilicate Glass Fibers Filter treated phenol acid) also removes moisture and oil of above $0.3{\mu}m$ to be involved in high pressure biogas up to 90%~98%.

  • PDF

A Study on the Swash Plate Behavior of Variable Displacement Compressor for Automotive Air Conditioning System (차량용 가변용량 압축기의 사판 거동에 관한 연구)

  • Lee, Tae-Jin;Lee, Geon-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1335-1340
    • /
    • 2004
  • Due to the distinct advantages of comfort, drive ability and fuel economy standard, the variable displacement swash plate type compressor which can control the compressor displacement by increasing or reducing the swash plate angle has been developed for automotive air-conditioning system. That can be obtained constant temperature of car room on the variation cooling capacities or engine speeds. This paper was carried out the analysis of swash plate behavior to obtain the forces and moments applied to the swash plate and to get the variable controlability on the variation of compressor speeds and swash plate chamber pressures. The results of simuation agree very well with the experimental data.

  • PDF