• Title/Summary/Keyword: Compressor Superheat

Search Result 46, Processing Time 0.027 seconds

Improvement of Compressor-Cooling Efficiency Based on Ribs (리브를 활용한 압축기 냉각 효율 향상에 관한 연구)

  • Hwang, Il Sun;Lee, Young Lim
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.6
    • /
    • pp.70-75
    • /
    • 2021
  • Recently, several efforts have been made to improve the thermal efficiency of a refrigerant compressor. In this study, we attempted to improve energy efficiency ratio (EER) performance by reducing the superheat of the linear compressor. To this end, heat generated inside the compressor must be effectively dissipated. Therefore, heat dissipation was improved by processing ribs in the gap-flow region generated owing to the vibration of the compressor body. The results showed that the convective heat transfer coefficient becomes significantly high when ribs are used, increasing the heat dissipation rate. This helps improve EER by reducing the superheat of the compressor.

An Analytic and Experimental Study on the Performance Characteristic of the Rotary Compressor (로타리 압축기 성능특성에 관한 해석 및 실험)

  • 최득관;김경천;차강욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.497-504
    • /
    • 2001
  • A study to improve the accuracy of a map-based compressor model with experiment was performed. Corrections on the effects of suction gas superheat and heat leakage from a compressor shell are required to apply the compressor amp model based on the empirical performance data(map) of compressor manufacturers to the actual system. So experiments to assess the effects of superheat and hat leakage were performed and the corrected equations were made. Compressors and refrigerant used in the experiment were the high pressure type rotary compressor and R-22, experiments were performed by compressor calorimeter. From the experiment, a volumetric efficiency correction factor$(F_ν)$ showed the value of 0.77, slightly higher than 0.75 proposed by Dabiri and Rice for low pressure type reciprocating compressor, and the heat leakage from the compressor shell turned out to be a factor that influenced the discharged mass flow rate. The relation between heat leakage of compressor shell and the variation of discharged mass flow rate from compressor was considered in compressor map modeling as an empirical function. With this function, the prediction accuracy of compressor model in system conditions was improved.

  • PDF

Superheat Control of an Inverter-driven Heat Pump Using PI Control Algorithm

  • Park, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.106-115
    • /
    • 2002
  • The performance of an inverter-driven water-to-water heat pump with an electronic expansion valve (EEV) was measured as a function of compressor frequency, load conditions, and EEV opening. Based on the test results, a controller using proportional integral (PI) feedback or PI feedforward algorithm was designed and tested to investigate capacity modulation and transient response control of the system. Although the relation between superheat and EEV opening of the heat pump showed nonlinear characteristics, a control gain obtained at the rated frequency was applicable to various operating conditions without causing large deviations. When the simple PI feedback control algorithm was applied, a large overshoot of superheat and wet compression were observed due to time delay effects of compressor frequency. However, applying PI feedforward control scheme yielded better system performance and higher reliability, compared to the PI feedback algorithm.

Experimental Study on Superheat Control of a Variable Speed Heat Pump (가변속 열펌프의 과열도 제어특성에 관한 실험적 연구)

  • 최종민;김용찬;하진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.233-241
    • /
    • 2001
  • In the present study, various experiments were performed to investigate the capacity modulation and transient response control using a variable speed compressor and electronic expansion valve(EEV). Based on the experimental results, the operation control algorithm and real time digital control system were constructed to adjust the superheat at the inlet of the compressor. Superheat control was fulfilled using both the PI feedback controller and PI controller combined with a feedforward concept. As a result, the tracking performance of the latter was better than that of former.

  • PDF

The EEV Control of the Multi-type Air-conditioning System by using a Fuzzy Logic Superheat Temperature Setpoint Reset Algorithm (퍼지로직 과열도 재설정 알고리즘을 사용한 멀티형 냉방시스템의 전자팽창밸브 제어)

  • 한도영;이상원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.382-388
    • /
    • 2003
  • Refrigerant flow rates of the multi-type air-conditioning system can be regulated by electronic expansion valves (EEV). The performance of the multi-type air-conditioning system may be improved by lowering the superheat at the compressor suction side. In this study, a superheat temperature setpoint reset algorithm was developed by using fuzzy logics, and a PI algorithm was applied to control the superheat temperature near setpoints. Experimental results showed energy savings and stable operations at a multi-type air-conditioning system. Therefore, the developed setpoint reset algorithm may be effectively used for the EEV superheat temperature control of the multi-type air-conditioning system.

Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree (전자팽창밸브 개도에 따른 가변속 수냉각기의 용량제어 특성)

  • Beak, Seung-Moon;Moon, Choon-Geun;Kim, Hyun-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.282-288
    • /
    • 2010
  • The paper presents the characteristics of capacity control of variable speed water cooler with the electronic expansion valve open/close degree. It is a preliminary study on the optimum control of the water cooler system using a variable speed compressor controlled by inverter. The electronic expansion valve controlled by the variation of compressor speed maintains the constant degree of superheat at the evaporator outlet, which aims to find the degree of superheat obtaining the optimum refrigeration effect. The investigation indicates that there is a point achieving the maximum cooling capacity by the variation of the electronic expansion valve open/close degree with constant compressor speed.

Transient Performance of a System Heat Pump with the Variation of Compressor Speed and EEV Openings (시스템 히트펌프의 압축기 주파수 및 전자팽창밸브 개도 변화에 따른 과도성능 특성)

  • Lee, Sang-Hyeok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.3
    • /
    • pp.11-18
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system utilizing package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only easy distribution control allowing free combination of indoor units with different models and different capacities, but also wide applications to an intelligent air conditioning. In this study, the transient performance of a system heat pump was analysed with the variation of compressor speed and EEV openings. The superheat was selected as a control parameter of the system, because the variation of it was consistent with each indoor unit capacity.

An Empirical Model for Decoupling Control of a Variable Speed Refrigeration System (가변속 냉동시스템의 비간섭제어를 위한 실험적 모델)

  • Hua, Li;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.81-87
    • /
    • 2006
  • This paper deals with an empirical model for decoupling control to control the refrigeration system effectively. The conventional control schemes of the system are mainly focused on representative two control methods, superheat control and capacity control. The capacity control is basically conducted to respond partial loading conditions on the purpose of energy saving. The superheat control is mainly carried out to maintain maximum coefficient of performance (COP). In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. The capacity and superheat can not be controlled independently because of interfering loop when the compressor speed and opening angle electronic expansion valve is varied. Therefore, we suggest decoupling model to eliminate the interfering loop at first. Next, each transfer function in decoupling control model is obtained from number of experiments.

  • PDF

Dynamic Analysis of Evaporator for Optimum Control in Refrigeration System (냉동사이클의 최적 제어를 위한 증발기 동특성 해석)

  • Jeong, S.K.;Hua, Li;Choi, K.H.;Yoon, J.I.;Kim, E.P.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-88
    • /
    • 2005
  • This paper presents numerical study on dynamic characteristics of evaporator to control evaporator superheat and compressor capacity with optimum condition in refrigeration system. It is very important to reduce energy consumption and to keep room temperature within a very restricted range with minimum oscillation in some special applications of the refrigeration system. Heat exchange is mainly happened in the evaporator. So, making mathematical model of evaporator and analyzing evaporator characteristics are necessary in order to control the superheat and the capacity of the system. A mathematical model based on the one dimensional partial differential equations representing mass and energy conservation and a tube-wall energy is described. A set of ordinary differential equation is formulated by integrating separately over the two regions(two-phase and vapor) generally presented in a heat exchanger.

  • PDF

Control of Compressor and Electronic Expansion Valve for a Tandom-type Air-conditioner (텐덤형 냉방시스템의 압축기와 전자팽창밸브 제어)

  • Jung, Nam-Chul;Han, Do-Young
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.469-473
    • /
    • 2005
  • Capacities of a tandom-type air-conditioner may be modulated by turning on/off multiple compressors and adjusting positions of a electronic expansion valve. In this study. control algorithms for compressors and a electronic expansion valve were developed by using fuzzy’ logics. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature.

  • PDF