• Title/Summary/Keyword: Compressor Characteristics

Search Result 653, Processing Time 0.026 seconds

An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions (부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구)

  • Choi, Sungkyung;Lee, Sang Hun;Kim, Sunjae;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.

A Numerical Analysis on a Dependence of Hydrogen Diaphragm Compressor Performance on Hydraulic Oil Conditions (오일부 운전조건 변화에 따른 수소용 다이어프램 압축기의 성능예측에 대한 수치해석)

  • Park, Hyun-Woo;Shin, Young-Il;Lee, Young-Jun;Song, Ju-Hun;Chang, Young-June;Jeon, Chung-Hwan
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.6
    • /
    • pp.471-478
    • /
    • 2009
  • The specific some types of compressors are appropriate for a use in hydrogen gas station. Metal diaphragm type of hydrogen compressor is one of them, which can satisfy the critical requirements of maintaining gas purity and producing high pressure over 850 bar. The objective of this study is to investigate an characteristics of compression through two-way Fluid-Structure-Interaction (FSI) analysis as bulk modulus and initial volume of oil independently varies. Deflection of diaphragm, oil density, gas and oil pressure were analyzed during a certain period of compression process. According to the analysis results, bulk modulus and initial volume remarkably affected deflection of diaphragm, oil density, gas and oil pressure. The highest gas pressure were attained with the highest bulk modulus of $7e^9\;N/m^2$ and the lowest initial oil volume of 80 cc.

Investigation of Transient Performance of An Auxiliary Power Unit Microturbine Engine (보조동력용 마이크로터빈 엔진에 대한 과도성능 해석)

  • Son, Ho-Jae;Kim, Soo-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.3
    • /
    • pp.20-28
    • /
    • 2007
  • The easiest way to see the phenomena of compressor surge is to show the static and dynamic operation characteristic on the map. Its operation zone will be restricted by the surge limit and, static and transient process must have some margin for it. Effect of rotor moment of inertia, air/gas volumes and heat transfer are factors to cause the transition from the static line. In case a large volume such as heat exchanger exists in the system it will exert a substantial influence to dynamic characteristics. In the present paper, influence of air volume bled from the compressor exit on transient process is investigated with an example of an auxiliary power unit micro-turbine engine. Turbine mass, pressure ratio, rotation speed, power and moment are calculated based on mass and work conservation. Result from the present study can give guidance to design the control system. A computer program is developed to calculate the dynamic process using the MathCAD commercial software.

Performance Evaluation of Nano-Lubricants at Thrust Slide-Bearing of Scroll Compressor (나노 윤활유를 이용한 스크롤 압축기 스러스트 베어링의 윤활특성 평가)

  • Cho, Han-Jong;Cho, Yong-Il;Cho, Sang-Won;Lee, Jae-Keun;Park, Min-Chan;Kim, Dae-Jin;Lee, Kwang-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.1
    • /
    • pp.121-125
    • /
    • 2012
  • This paper presents the friction and anti-wear characteristics of nano-oil with a mixture of a refrigerant oil and carbon nano-particles in the thrust slide-bearing of scroll compressors. Frictional loss in the thrust slide-bearing occupies a large part of total mechanical loss in scroll compressors. The characteristics of friction and anti-wear using nano-oil is evaluated using the thrust bearing experimental apparatus for measuring friction surface temperature and the coefficient of friction at the thrust slide-bearing as a function of normal loads up to 4,000 N and rotating speed up to 3,200 rpm. It is found that the coefficient of friction increases with decreasing rotating speed and normal force. The friction coefficient of carbon nano-oil is 0.023, while that of pure oil is 0.03 under the conditions of refrigerant gas R-22 at the pressure of 5 bars. It is believed that carbon nano-particles can be coated on the friction surfaces and the interaction of nano-particles between surfaces can be improved the lubrication in the friction surfaces. Carbon nano-oil enhances the characteristics of the anti-wear and friction at the thrust slide-bearing of scroll compressors.

A Study on the Performance Characteristics of Water Heat Source Heat Pump System using CO2 Refrigerant (이산화탄소를 사용한 수열원 히트펌프 시스템의 성능 특성에 관한 실험적 연구)

  • Chang, Keun-Sun;Kang, Hee-Jeong;Kim, Young-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3366-3373
    • /
    • 2011
  • In this study, performance characteristics of a water source heat pump system using $CO_2$ as a refrigerant are investigated experimentally. Cooling and heating capacities and COP of the system are analyzed for various system performance variables such as refrigerant charge, expansion valve opening, compressor frequency and internal heat exchanger. Results show that optimum amount of refrigerant charge and expansion valve opening exists at maximum point of COP curve, and cooling capacity increases but COP decreases with the increase of compressor frequency. When the internal heat exchanger is installed, cooling capacity increases about 4.0% whereas heating capacity decreases about 0.89% compared to the case without internal heat exchanger.

Study on the Modal Test for a Turbocharger Wheel Using Vibro-acoustic Responses (진동 방사음을 이용한 터보차져 휠 동특성 시험에 대한 고찰)

  • Lee, Hyeong-Ill;Lee, Dug-Young;Park, Ho-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.29-37
    • /
    • 2011
  • The modal characteristics of a compressor wheel of an automotive turbocharger have been investigated using an experimental method based on an acoustic frequency response function, p/f(${\omega}$), where p is sound pressure radiated from a structure, and f is impact force. First, a well-defined annular disc with narrow radial slots was examined to check whether the vibro-acoustic test could precisely determine natural quencies and vibration modes of structures showing that the vibro-acoustic test proposed in this paper was comparable to the conventional modal test with an accelerometer and the numerical analysis. The conventional method has been found to be inappropriate for compressor wheel because of additional mass due to the accelerometer and additional damping from the accelerometer cable alter the dynamic responses of the wheel blades. odal characteristics of the wheel have been defined using vibro-acoustic test and verified with the results from another conventional method using a laser vibrometer. Natural quencies and mode shapes of a turbocharger wheel, which can't be precisely obtained with onventional method, could be defined accurately without the additional effects from sensor and cable. Proposed method can be applied to small structures where conventional sensors and cables could generate troubles.

Performance Evaluation of Nano-Lubricants at Journal Bearing of Scroll Compressors (나노 윤활유를 이용한 스크롤 압축기 저널 베어링의 윤활특성 평가)

  • Kim, Kyong-Min;Hwang, Yu-Jin;Lee, Kwang-Ho;Sung, Chi-Un;Lee, Jae-Keun;Jung, Won-Hyun;Kim, Sung-Choon;Jin, Hong-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.189-193
    • /
    • 2008
  • Performance of refrigerant oil at the thrust-bearing and at the journal-bearing of a scroll compressor is a significant factor. This paper presents the friction and anti-wear characteristics of nano oil with a mixture of a refrigerant oil and carbon nano particles in the journal bearing of scroll compressors. The characteristics of friction and anti-wear using nano-oil is evaluated using the disk on disk tester and the journal bearing tester for measuring friction surface temperature and the coefficient of friction at the journal bearing tester. In journal bearing test, the average friction coefficient of high concentration nano-oil was decreased down to 18% compared to raw oil under 4,500 N and 3,600 rpm. It is believed that nano particles can be coated on the wear surfaces and the interaction of nano particles between surfaces can be improved the lubrication in the friction surfaces. Worn surfaces of frictional specimen were measured with straightness. carbon nano oil enhances the characteristics of the anti-wear and friction at the joural bearing of scroll compressors.

  • PDF

Tribological Characteristics of DLC-Coated Part in Compressor (컴프레서 부품의 DLC코팅 적용에 따른 트라이볼로지적 특성 연구)

  • Yoon, Joo-Yong;Seo, Kuk-Jin;Han, Jae-Ho;Chun, Jihwan;Song, Jiyoung;Koh, Youngdeog;Nam, Jahyun;Kim, Seonkyo;Kim, Dae-Eun
    • Tribology and Lubricants
    • /
    • v.38 no.1
    • /
    • pp.8-14
    • /
    • 2022
  • Amorphous carbon (a-C) has excellent wear resistance and, therefore is used as a coating to protect numerous mechanical components to prolong their lifetimes. Among the a-C coatings, diamond-like carbon (DLC) and DLC-containing silicon (Si-DLC) receive extensive attention owing to their enhanced wear resistance and low frictional characteristics. In this study, the friction and wear characteristics of DLC and Si-DLC coatings are analyzed. For comparative analysis, DLC-coated and Si-DLC-coated vanes are utilized with the counterpart of a roller for the friction tests. Since the lubricated mechanical components are generally vulnerable to wear when a lubricant film does not form properly, friction tests are conducted under boundary lubrication conditions to promote wear. A cylinder-on-cylinder type tribometer is used to perform the friction tests with various normal load conditions. After the friction test, a 3D laser confocal microscope is used for quantifying the wear volume to calculate the wear rate of each specimen. Consequently, the DLC-coated specimen shows a lower coefficient of friction (COF) and wear rate than the specimen without the coating, while the Si-DLC coating shows a higher COF than the bare specimen. The results of this study are expected to contribute to improving the efficiency and reliability of compressors.

Separation characteristics of separation devices using inlet water mixed with exhalation gases without a compressor (날숨이 혼합된 물을 사용한 압축기없는 용존기체 분리기의 분리 특성)

  • Heo, Pil Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.842-846
    • /
    • 2016
  • It's possible for a human to breathe under water, but the amount of dissolved oxygen in the water is small and a large amount of water is necessary to obtain sufficient dissolved oxygen from water. So, large separation system with large water pumps, having large surface areas, and large battery sources are needed. Exhalation gases are used to solve this problem. Theses gases contain some oxygen, nitrogen, and carbon dioxide; they contain less oxygen and more carbon dioxide compared to air. Therefore, reduction of the amount of carbon dioxide is necessary. If exhalation gases are employed appropriately, the separation device can be made more compact. Inlet water mixed with exhalation gases is supplied into the separation device, and dissolved gases are separated from the mixed water as it passes through the device. The inlet part of a typical separation system with a water delivery pump before the membrane module has more than one atmosphere. Hence, a compressor is used to mix the exhalation gases. In this study, the pressure at the inlet due to the use of a suction pump after the membrane module was less than one atmosphere; hence, compressors were not required. Separation characteristics were studied using a separation device without a compressor. The use of exhalation gases led to an increase in the amount of dissolved gases being separated. As the amount of inlet exhalation gases was increased, the separation of dissolved gases was increased as well.

Comparison of the Characteristics of 16 Commercial Nebulizer/Compressor Combinations Used in Korea (국내 시판되는 16가지 연무기/압축기의 성능 평가)

  • Kim, Hyun Jung;Lee, Cho Ae;Hwang, Eun Kyung;Han, Man Young;Ann, Uk Sung;Cho, Young Min
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1235-1241
    • /
    • 2003
  • Purpose : We assessed the dynamic characteristics of 16 nebulizer/compressor combinations currently available in Korea. Methods : The 16 nebulizer/compressor combinations(Pariboy Type 38/Long life, Pariboy Type N/Long life, Pariboy Type N/Salter 8900, Pariboy Type N/LC, Devilbiss pulmoaid-LT/Hudson, Devilbiss pulmoaid/Hudson, Mesmed neb-300/Own, San-up 3040/Hudson, Midas(Basic)/Own, AirJolie 2/Hudson, Thomas 1127/Salter 8900, Noel NE-2000/Salter 8900, Omron CX3/Hudson, Chang Woo CWN-100/Salter 8900, Voyage/Mefar, Chang Woo ASI-Pro/Medel jet pulse) were evaluated in terms of particle size and mass output. In addition, we determined the effects of nebulizer fill volume on mass output. Results : Pariboy Type N/Long life has the highest respirable mass of 0.184 mg/min and Mesmed Neb-300/Own has the lowest 0.019 mg/min. Pariboy Type N/Long life has the highest mass output of 0.68 mg/min and the shortest mass median aerodynamic diameter(MMAD) of $3.76{\mu}m$. All combinations other than Pariboy Type N/Long life produced a MMAD of over $5{\mu}m$. MMAD over a 5 min nebulization ranged 3.76 to $9.83{\mu}m$. There were no significant effects of fill volume on mass output. Conclusion : We concluded that there is a wide variation in performance of nebulizer/compressor combinations. The characteristics of nebulizer/compressor combinations should be considered in selecting products.