• 제목/요약/키워드: Compressive strengths

검색결과 925건 처리시간 0.03초

충격시 CFRP 복합재 판의 거동과 충격후 압축강도에 관한 실험적 연구 (Experimental Investigation on the Behaviour of CFRP Laminated Composites under Impact and Compression After Impact (CAI))

  • Lee, J.;Kong, C.;Soutis, C.
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.129-134
    • /
    • 2003
  • The importance of understanding the response of structural composites to impact and CAI cannot be overstated to develop analytical models for impact damage and CAI strength predictions. This paper presents experimental findings observed from quasi-static lateral load tests, low velocity impact tests, CAI strength and open hole compressive strength tests using 3mm thick composite plates ($[45/-45/0/90]_{3s}$ - IM7/8552). The conclusion is drawn that damage areas for both quasi-static lateral load and impact tests are similar and the curves of several drop weight impacts with varying energy levels (between 5.4 J and 18.7 J) fallow the static curve well. In addition, at a given energy the peak force is in good agreement between the static and impact cases. From the CAI strength and open hole compressive strength tests, it is identified that the failure behaviour of the specimens was very similar to that observed in laminated plates with open holes under compression loading. The residual strengths are in good agreement with the measured open hole compressive strengths, considering the impact damage site as an equivalent hole. The experimental findings suggest that simple analytical models for the prediction of impact damage area and CAI strength can be developed on the basis of the failure mechanism observed from the experimental tests.

  • PDF

Mechanical, durability and microstructure properties of concrete containing natural zeolite

  • Nas, Memduh;Kurbetci, Sirin
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.449-459
    • /
    • 2018
  • Concrete is one of the most widely used construction materials in the world. Producing economical and durable concrete is possible by employing pozzolanic materials. The aim of this study is to underline the possibility of the utilization of natural zeolite in producing concrete and investigate its effects basically on the strength and durability of concrete. In the production of concrete mixes, Portland cement was replaced by the natural zeolite at ratios of 0%, 10%, 15%, and 20% by weight. Concretes were produced with total binder contents of $300kg/m^3$ and $400kg/m^3$, but with a constant water to cement ratio of 0.60. In addition to compressive and flexural strength measurements, freeze-thaw and high temperature resistance measurements, rapid chloride permeability, and capillary water absorption tests were performed on the concrete mixes. Compared to the rest mixes, concrete mixes containing 10% zeolite yielded in with the highest compressive and flexural strengths. The rapid chloride permeability and the capillary measurements were decreased as the natural zeolite replacement was increased. Freeze-thaw resistance also improved significantly as the replacement ratio of zeolite was increased. Under the effect of elevated temperature, natural zeolite incorporated concretes with lower binder content yielded higher compressive strength. However, the compressive strengths of concretes with higher binder content after elevated temperature effect were found to be lower than the reference concrete.

The effects of replacement fly ash with diatomite in geopolymer mortar

  • Sinsiri, Theerawat;Phoo-ngernkham, Tanakorn;Sata, Vanchai;Chindaprasirt, Prinya
    • Computers and Concrete
    • /
    • 제9권6호
    • /
    • pp.427-437
    • /
    • 2012
  • This article presents the effect of replacement fly ash (FA) with diatomite (DE) on the properties of geopolymer mortars. DE was used to partially replace FA at the levels of 0, 60, 80 and 100% by weight of binder. Sodium silicate ($Na_2SiO_3$) and sodium hydroxide (NaOH) solutions were used as the liquid portion in the mixture in order to activate the geopolymerization. The NaOH concentrations of 15M, $Na_2SiO_3$/NaOH ratios of 1.5 by weight, and the alkaline liquid/binder (LB) ratios by weight of 0.40, 0.50, 0.60 and 0.70 were used. The curing at temperature of $75^{\circ}C$ for 24 h was used to accelerate the geopolymerization. The flows of all fresh geopolymer mortars were tested. The compressive strengths and the stress-strain characteristics of the mortar at the age of 7 days, and the unit weights were also tested. The results revealed that the use of DE to replace part of FA as source material in making geopolymer mortars resulted in the increased in the workability, and strain capacity of mortar specimens and in the reductions in the unit weights and compressive strengths. The strain capacity of the mortar increased from 0.0028 to 0.0150 with the increase in the DE replacement levels from 0 to 100%. The mixes with 15M NaOH, $Na_2SiO_3$/NaOH of 1.5, LB ratio of 0.50, and using $75^{\circ}C$ curing temperature showed 7 days compressive strengths 22.0-81.0 MPa which are in the range of normal to high strength mortars.

무시멘트 알칼리 활성 고로슬래그 콘크리트의 배합에 따른 재료 역학적 특성 (Synthesis and Mechanical Properties of Alkali-Activated Slag Concretes)

  • 송진규;이강석;한선애;김용인
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1005-1008
    • /
    • 2008
  • 본 연구에서는 시멘트의 대체재로써 고로슬래그를 사용한 무시멘트 알칼리 활성화 고로슬래그 콘크리트의 배합에 따른 기본적인 역학적 특성에 대해 파악하였다. 압축강도에 영향을 줄 수 있는 변수를 기존의 모르터 연구 및 예비 실험을 통해 설정한 후 배합하여 1, 3, 7, 28, 56, 91일의 압축강도를 측정하였다. 압축강도 실험에서 알칼리 활성 고로슬래그 콘크리트는 OPC(보통 포틀랜드 시멘트) 콘크리트에 비해 초기 강도가 빠르게 발현되었으며, 특히 1, 3일 강도는 OPC 콘크리트보다 약 $1.5{\sim}3$배 정도 높게 나타났다. 응력-변형률 관계에서는 알칼리 활성 고로슬래그 콘크리트는 최대 응력 이후에 변형률이 $0.0020{\sim}0.0025$에서 콘크리트의 파괴가 급격히 발생하였으며, 규산나트륨을 많이 첨가한 경우 고강도 콘크리트처럼 취성적 파괴를 보였다.

  • PDF

폴리머 디스퍼션을 이용한 프리팩트 콘크리트용 주입 모르타르의 배합에 관한 연구 (Mix Design of Polymer Grouting Mortar for Prepacked Concrete Using Polymer Dispersions)

  • 조영국;김완기
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.85-91
    • /
    • 2008
  • Prepacked concrete has recently been used in the special constructions fields such as underwater concrete work, heavy-weight concrete work, underground structure work, partial repair works for damaged reinforced concrete structures. and polymer-modified mortars have been employed as grouting mortars for the prepacked concrete. The purpose of this study is to recommend the optimum mix design of polymer-modified grouting mortars for prepacked concrete. Polymer-modified mortars using SBR and EVA emulsions as admixture of grouting mortars for prepacked concrete are prepared with various mix proportions such as sand-binder ratio, fly ash replacement ratio, polymer-binder ratio. and tested for flowability, viscosity of grouting mortars, bleeding ratio, expansion ratio, flexural and compressive strengths of grouting mortars and compressive and tensile strengths of prepacked concretes. From the test results, it is apparent that polymer-modified mortars can be produced as grouting mortars when proper mix design is chosen. We can design the mix proportions of high strength mortars for prepacked concrete according to the control of mix design factors such as type of polymer, polymer-binder ratio, sand-binder ratio and fly ash replacement ratio. Water-binder ratio of plain mortars for a constant flowability value are in the ranges of 43% to 50%. SBR-modified mortar has a little water-binder ratios compared to those of plain mortar, however, EVA-modified mortar needs a high water-binder ratio due to a high viscosity of polymer dispersion. The expansion and bleeding ratios of grouting mortars are also controlled in the proper value ranges. Polymer-modified grouting mortars have good flexural. compressive and tensile strengths, are not affected with various properties with increasing fly ash replacement to cement and binder-sand ratio. In this study, SBR-modified grouting mortar with a polymer-binder ratio of 10% or less, a fly ash replacement of 10% to cement and a sand-binder ratio of 1.5 is recommended as a grouting mortar for prepacked concrete.

에폭시 수지 모르터의 강도 특성 (Strength Characteristics of Epoxy Resin Mortar)

  • 정규석;강신업
    • 한국농공학회지
    • /
    • 제24권3호
    • /
    • pp.92-99
    • /
    • 1982
  • The objective of this study was to investigate the compressive and bending strength characteristics of epoxy resin mortar, which is still in an early stage of its use and study in Korea. The results obtained are summarized as follows; 1. The compressive strengths of epoxy resin mortar after 1 day, 2 days and 3 days were gained 87%, 91% and 95%, respectively, in view of that of mortar at the age of 7 days. This result showed that the initial compressive strength within 1 day was very high. 2. The highest compressive strength of epoxy resin mortar was 914 kg/cm2 at the point of having the mixing ratio of one to two. It reached up to 3.7 times that of the normal portland cement mortar at the age of 28 days. 3. The bending strengths of epoxy resin mortar after 1 day, 2 days and 3 days came up to 88%, 93% and 97%, respectively, in comparing that of mortar at the age of 7 days. It was expressed to be simielar to the tendency of compressive strength. 4. The highest bending strength of epoxy resin mortar was 384 kg/cm2 at mixing ratio of one to two. It came up to as much as 6.5 times in comparing with that of the normal portland cement mortar at the age of 28 days. Therefore, the epoxy resin mortar would be effective for promoting the bending strength of structural members. 5. The regression equation between compressive and bending strength was obtained as follows; oo~=0.391 oc+27.54 (r=0.99) And the estimated value of bending strength was corresponded to about 44 per cent in comparing with that of the compressive strength.

  • PDF

구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구 (THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS)

  • 박연홍;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF

이층 포설 콘크리트 포장의 국내 적용을 위한 강섬유 보강 콘크리트 기초 물성평가 (Estimation of The Basic Properties of Two-Lift Concrete Pavement to Apply Korea Condition)

  • 원홍상;류성우;홍종용;조윤호
    • 한국도로학회논문집
    • /
    • 제12권1호
    • /
    • pp.47-54
    • /
    • 2010
  • 본 연구에서는 콘크리트 포장의 균열, 스폴링 등의 파손문제를 해결하기 위해 국내 시공사례가 없는 이층 포설 공법의 도입 및 기술 경제적 타당성을 검토하고자 하였다. 본 포장공법중 하나인 강섬유 보강 콘크리트(SFRC, Steel Fiber Reinforced Concrete)의 포장 배합 적용성이 검토되었다. 강섬유 함량과 포장 높이가 산정되었으며, 강섬유 보강 콘크리트의 물성 평가를 위해 압축강도, 휨강도, 휨인성 지수, 인장강도, 피로강도를 측정하였다. 슬럼프와 공기량은 대부분이 시방 기준을 만족하였으며, 28일 강도도 교통개방을 할 수준 정도로 발현되었다. 휨강도 실험 결과, 강섬유 보강 콘크리트가 무보강 콘크리트에 비해 휨인성은 증가하였지만 휨강도는 증가하지 않았다. 에너지 흡수능력, 피로 저항성 및 동결 융해저항성은 강섬유 보강 콘크리트가 무보강 콘크리트에 비해 향상되었다. 향후, 시험시공을 통해 강섬유 보강 콘크리트의 현장 적용성 및 공용성을 평가할 것이다.

고강도 콘크리트의 역학적 특성에 대한 실험 연구 (An Experimental Study of Mechanical Properties of High-strength Concrete)

  • 양인환;황철성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권6호
    • /
    • pp.206-215
    • /
    • 2017
  • 이 연구에서는 고강도 콘크리트의 역학적 특성을 파악하기 위한 실험연구를 수행하였다. 80~120 MPa 범위의 압축강도를 갖는 고강도 콘크리트를 대상으로 실험연구를 수행하였다. 물-결합재비의 압축강도에 대한 영향, 시간에 따른 압축강도의 발현 및 양생조건의 압축강도에 대한 영향을 분석하였다. 또한, 양생조건에 따른 콘크리트의 탄성계수, 쪼갬인장강도 및 파괴계수 특성을 파악하였다. 탄성계수, 쪼갬인장강도 및 파괴계수의 실험결과와 기존설계코드에 의한 예측결과를 비교하였다. 콘크리트구조기준의 탄성계수 제안식은 실험값을 합리적으로 예측한다. 반면에, 콘크리트구조기준은 파괴계수 실험값을 과소평가하고 있다. ACI 363R의 쪼갬인장강도와 파괴계수 예측값과 실험값은 잘 일치하고 있다. 따라서, ACI 363R의 쪼갬인장강도와 파괴계수 예측식은 120 MPa까지의 고강도 콘크리트에 효과적으로 활용될 수 있다.

鋼纖維에 의한 콘크리트의 補强效果 (Effects of Steel Fiber Concrete)

  • 고재군;김문기;이신호
    • 한국농공학회지
    • /
    • 제27권2호
    • /
    • pp.47-56
    • /
    • 1985
  • Wasting fiberous residues from the cutting processes of steel materials at an iron-Works were mixed with concrete. The strength and toughness of steel fiber concrete with different steel contents were tested in a laboratory. The test results showed that the steel fiber residues can be used for the reinforcement of concrete. The potential applications of such product include floor constructions for facilities like dairy barns, grain storages, and machinery shops. The test results are as follows. 1. The compressive strengths of steel fiber concrete with one percent steel content by volume were 20 percent greater than that of plain concrete. The treatments also increased the concrete toughness by 96 percent. 2. When applied to tensile forces, the steel fiber concrete showed the increased strengths by 20 percent, and the toughness by 48 percent. 3. The steel content levels greater than or equal to 1.5 percent by volume resulted in the decreases of the compressive and tensile strengths of steel fiber concrete by 10 percent as compared to plain concrete. The concrete toughness increased with the steel contents. 4. The reinforcement effects of steel fiber depend on the quality of fiber material being used. Good steel fiber for concrete reinforcement appears to be uniform in shape and component, fine and long, and round-shaped.

  • PDF