• Title/Summary/Keyword: Compressive stiffness

Search Result 403, Processing Time 0.024 seconds

Flexural Behavior of Ultra High Performance Fiber Reinforced Concrete Segmental Box Girder (초고강도 섬유보강 콘크리트 분절형 박스 거더의 휨거동)

  • Guo, Qingyong;Han, Sang-Mook
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.109-116
    • /
    • 2014
  • The flexural behavior test of UHPC segmental box girder which has 160 MPa compressive strength and 15.4 m length was carried out. The effect of steel fibers in combination with reinforcing bars on improving the ductile performance of UHPC box girder was evaluated by comparing the flexural behavior of the UHPC segmental box girders made by the two kinds of mixing portion. The test variables are volume fraction of steel fibers and the arrangement of reinforcing bars. The behavior of UHPC box girder BF2 composed of 1% volume fraction of steel fibers and longitudinal reinforcing bars in web and upper flange with stirrup showed the similar ductile behavior with the girder BF1 composed of 2% volume fraction without stirrup in elastic stress region. But BF1 had the better stiffness and showed the more ductile behavior in inelastic stress region. Segmental interfaces of UHPC box girder have not any crack and slide until the final flexural collapse load.

Design of Composite Laminates Using Enumeration Method (나열법을 이용한 복합재 적층판 설계)

  • Joung, Chanwoo;Bae, Il-Joon;Park, Young-Bin
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.288-295
    • /
    • 2020
  • Fiber-reinforced composite laminates have high specific stiffness and strength and are expected to be useful for weight reduction in weight-sensitive industries, such as automotive and aerospace. However, designing composite laminates is often dependent on designer's experience and intuition because of difficulties in determining the number of plies and stacking sequence, which tends to lead to over-design. In this study, optimal design of composite laminates was performed to minimize weight, while withstanding the given load. Based on the enumeration method, all combinations of stacking sequence satisfying the design guideline for composite laminates were considered. Composite laminates were discretized into panels. Optimal number of plies and stacking sequence for each panel were determined considering local load on each panel and contiguity across adjacent panels. Failure index from Tsai-Wu criteria was optimized for strength and buckling analysis was performed for compressive load. Stacking angles of 0, ±45 and 90° were used.

An Experimental Study on the Hybrid Composite Carbody Structure (하이브리드 복합재 철도차량 차체에 대한 시험적 연구)

  • Kim Jung-Seok;Jeong Jong-Cheol;Lee Sang-Jin
    • Composites Research
    • /
    • v.18 no.6
    • /
    • pp.19-25
    • /
    • 2005
  • This paper has performed an experimental study on the hybrid composite carbody of Korean tilting railway vehicle. The hybrid composite carbody has the length of 23m and is comprised of a 40mm-thick aluminium honeycomb core and 2mm-thick woven fabric carbon/epoxy face sheet. In order to evaluate the structural behavior and safety of the hybrid composite carbody, the static load tests such as vertical load, end compressive load, torsional load and 3-point support load tests have been conducted. The test was performed under Japanese Industrial Standard (JIS) 17105 standard. from the tests, the maximum deflection was 12.3mm and the equivalent bending stiffness of the carbody was $0.81\times10^{14}\;kgf{\cdot}mm^2$. The maximum strain of the composite body was below $20\%$ of failure strain of the carbon/epoxy face sheet.

An Experimental Study on the Material Properties of the EG/AD Model Ice Used for Ice Model Basins (빙해수조용 EG/AD 모형빙의 재료특성 실험)

  • Kim, Jung-Hyun;Choi, Kyung-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • The EG/AD/S model ice, originally developed by Timco (1986), was selected as the primary model ice material for the newly built MOERI Ice Model Basin in Korea. However, the existence of a sugar component in the EG/AD/S mixture may cause a serious maintenance problem, as described in certain references. This study focuses on the tests of the mechanical properties of the EG/AD/S and the EG/AD model ice. In order to understand the influence of sugar in the original EG/AD/S model ice and to find a possible substitute for sugar, a series of tests with the EG/AD model ice were performed, and the results were compared to those of the EG/AD/S model ice. The relatively large size of the MOERI Ice Model Basin made it difficult to control the initial strength of model ice, so it took a much longer time to achieve the target strength. In order to obtain a lower strength and stiffness for the model ice, the amount of chemical additives may be varied to achieve the desired strength level. This paper is a preliminary study aimed at seeking a possible substitute for the original EG/AD/S model ice for utilization in a large-scale ice tank. To understand the influence of sugar in the original EG/AD/S model ice, the mechanical properties of the EG/AD/S and EG/AD model ice, such as flexural strength, compressive strength, and elastic modulus, were tested in the laboratory condition and compared to each other. The warm-up procedure seems to be an important factor to reduce ice strength in the tests, so it is discussed in detail.

Evaluation of Local Buckling Strength of Stiffened Plates under Uni-axial Compression due to Closed-section Rib Stiffness (폐단면리브 강성에 따른 일축압축을 받는 보강판의 국부좌굴강도 평가)

  • Choi, Byung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.949-954
    • /
    • 2013
  • Generally, structural plates under axial compression should be stiffened by longitudinal stiffeners in order to enhance the buckling strength. Though U-shaped ribs would be more efficient for the stiffened plate system, there is in the absence of a proper design guides or relevant research results. Thus this study is aimed to examine the local buckling behavior of stiffened plates with U-section ribs. 3-dimensional analysis models which include 3 types of U-shaped longitudinal stiffeners were simulated by using the finite element code ABAQUS. The bifurcation analysis were conducted and then the buckling analysis results are compared with the theoretical equation values. It is found that the rotational constraint effect provided by the U-ribs should increase the local buckling strength. Some features drawn from a series of parametric study results are summarized.

Structural Behavior of Flexurally Reinforced FRP-Concrete Composite Compression Member with FRP (FRP로 휨보강된 FRP-콘크리트 합성압축재의 구조적 거동)

  • Park, Joon-Seok;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.3
    • /
    • pp.10-16
    • /
    • 2010
  • In construction industries, new construction materials are needed to overcome some problems associated with the use of conventional construction materials due to the change of environmental and social requirements. Accordingly, the requirements to be satisfied in the design of civil engineering structures are diversified. As a new construction material in the civil engineering industries, fiber reinforced polymeric plastic (FRP) has a superior corrosion resistance, high specific strength/stiffness, etc. Therefore, such properties can be used to mitigate the problems associated with the use of conventional construction materials. Nowadays, new types of bridge piers and marine piles are being studied for new construction. They are usually made of concrete filled fiber reinforced polymeric plastic tubes (CFFT). In this paper, a new type of FRP-concrete composite pile which is composed of reinforced concrete filled FRP tube (RCFFT) is proposed to improve compressive strength as well as flexural strength. The load carrying capacity of proposed RCFFT compression member is discussed based on the result of experimental and analytical investigations.

  • PDF

Experimental Study for Ultimate Behavior of Steel Cable Stayed Bridge Under Construction (실험을 통한 시공 중 강사장교의 극한거동 연구)

  • Lee, Kee Sei;Kim, Seung Jun;Choi, Jun Ho;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.683-692
    • /
    • 2012
  • The girders of cable stayed bridge are subjected to not only the bending moments but also additional compressive axial forces due to the horizontal components of cable forces. Because of these axial forces, the stiffness of girder can be decreased, and this problem should be considered especially for under-construction model rather than the full model. Korean domestic design specification suggests the linear elastic eigen value analysis for the stability problem of cable stayed bridges. However, this method cannot be applied to the under construction model because various geometric nonlinear characteristics cannot be considered. Therefore, in this study, 3 models which are assumed to be constructed by balanced cantilever will be considered experimentally and analytically to analyze the behavior of steel cable stayed bridges.

Determination of Damage Thresholds and Acoustic Emission Characteristics of Pocheon Granite under Uniaxial Compression

  • Jang, Hyun-Sic;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.349-365
    • /
    • 2018
  • The strain and acoustic emission (AE) signals of Pocheon granite were measured during uniaxial compression tests to investigate microcrack formation and damage. Crack closure, initiation, and damage stresses of each sample were determined through an analysis of the crack volumetric strain and stiffness. The samples experienced four damage stages according to stress levels: stage 1 = crack closure stage; stage 2 = elastic stage; stage 3 = crack initiation stage; stage 4 = crack damage stage. At least 75% of all AE signals occurred in stages 3 and 4, and different AE parameters were detected in the four stress stages. Rise time, count, energy, and duration clearly showed a tendency to gradually increase with the damage stress stage. In particular, the rise time, energy, and duration increased by at least 95% in stage 4 as compared with stage 1. However, the maximum amplitude showed a smaller increase, and the average frequency decreased slightly at higher stages. These results indicate that as the degree of rock damage increases, the crack size grows larger. The crack types corresponding to the AE signals were determined using the relationship between RA (Rise time / Amplitude) values and average frequencies. Tension cracking was dominant in all stress stages. Shear cracking was rare in stages 1 and 2, but increased in stages 3 and 4. These results are consistent with previous studies that reported cracking begins after samples have already been damaged. Our study shows that the state of rock damage can be investigated solely through an analysis of AE parameters when rocks are under compressive stress. As such, this methodology is suitable for understanding and monitoring the stress state of bedrock.

Development of the Hybrid CFFT Pile (FRP-콘크리트 합성말뚝의 개발)

  • Choi, Jin-Woo;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.2
    • /
    • pp.20-28
    • /
    • 2010
  • In this paper, new type CFFT (Concrete Filled FRP Tube) was suggested in order to improve the flexural stiffness. Since the existing CFFT was produced by filament winding process, re-bar for concrete may be necessary in order to ensure structural safety under flexure re-bar. In comparison with existing type CFFT, new type CFFT was reinforced by circular shaped pultrusion FRP without re-bar. Filament winding FRP was attached to the outer layer of pultrusion FRP. Structural behavior of new type CFFT filled with concrete (HCFFT) was investigated by the mechanical property test for the component element and the FE analysis. Furthermore, compressive strength of the HCFFT member based on the equation suggested in previous studies.

  • PDF

Design and Analysis on Composite Structure for Aircraft Certification (항공기 인증을 위한 복합재 구조물 설계/해석)

  • Kim, Sung-Joon;Choi, Ik-Hyeon;Ahn, Seok-Min;Yeom, Chan-Hong
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.42-48
    • /
    • 2009
  • There are a number of factors affecting the continued airworthiness of composite structure. Unlike metal structure, damages made in manufacturing processes or maintenance repair procedures need to be considered. The different levels of degradation and damage, which may occur, must be considered for structural substantiation of static strength, stiffness, flutter, and damage tolerance. This can start with an evaluation of environmental effects for the particular composite material. Matrix-dominated composite properties, such as compressive strength, are most sensitive to moisture absorption and temperatures. Static strength substantiation includes the smaller damages that will not be detected in production or maintenance inspection while damage tolerance addresses larger damages that need to be repaired once discovered. In this paper, we intend to list the airworthiness regulations and advisory circular that are deemed closely related to the certification of composite airplanes.

  • PDF