• Title/Summary/Keyword: Compressive force

Search Result 614, Processing Time 0.027 seconds

Preload effects on behaviour of FRP confined concrete: Experiment, mechanism and modified model

  • Cao, Vui Van
    • Advances in concrete construction
    • /
    • v.9 no.6
    • /
    • pp.597-610
    • /
    • 2020
  • Stress-strain models of fibre reinforced polymer (FRP) confined concrete have been widely investigated; however, the existing load which is always supported by structures during the retrofitting phase, namely 'preload', has been neglected. Thus, preload effects should be clarified, providing insightful information for FRP retrofitting of structures with preload conditions. Towards this aim, experiments were performed for 27 cylinder concrete specimens with the diameter 150 mm and the height 300 mm. Three specimens were used to test the compressive strength of concrete to compute the preloads 20%, 30% and 40% of the average strength of these specimens. Other 24 specimens were divided into 2 groups; each group included 4 subgroups. Four subgroups were subjected to the above preloads and no preload, and were then wrapped by 2 FRP layers. Similar designation is applied to group 2, but wrapped by 3 FRP layers. All specimens were tested under axial compression to failure. Explosive failure is found to be the characteristic of specimens wrapped by FRP. Experimental results indicated that the preload decreases 12-13% the elastic and second stiffness of concrete specimens wrapped by 2 FRP layers. The stiffness reduction can be mitigated by the increase of FRP layers. Preload negligibly reduces the ultimate force and unclearly affects the ultimate displacement probably due to complicated cracks developed in concrete. A mechanism of preload effects is presented in the paper. Finally, to take into account preload effects, a modification of the widely used model of un-preload FRP confined concrete is proposed and the modified model demonstrated with a reasonable accuracy.

Structural behavior of inverted V-braced frames reinforced with non-welded buckling restrained braces

  • Kim, Sun-Hee;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.19 no.6
    • /
    • pp.1581-1598
    • /
    • 2015
  • A concentric braced steel frame is a very efficient structural system because it requires relatively smaller amount of materials to resist lateral forces. However, primarily developed as a structural system to resist wind loads based on an assumption that the structure behaves elastically, a concentric braced frame possibly experiences the deterioration in energy dissipation after brace buckling and the brittle failure of braces and connections when earthquake loads cause inelastic behavior. Consequently, plastic deformation is concentrated in the floor where brace buckling occurs first, which can lead to the rupture of the structure. This study suggests reinforcing H-shaped braces with non-welded cold-formed stiffeners to restrain flexure and buckling and resist tensile force and compressive force equally. Weak-axis reinforcing members (2 pieces) developed from those suggested in previous studies (4 pieces) were used to reinforce the H-shaped braces in an inverted V-type braced frame. Monotonic loading tests, finite element analysis and cyclic loading tests were carried out to evaluate the structural performance of the reinforced braces and frames. The reinforced braces satisfied the AISC requirement. The reinforcement suggested in this study is expected to prevent the rupture of beams caused by the unbalanced resistance of the braces.

A FINITE ELEMENT ANALYSIS ON THE EFFECT OF THE REVERSE HEADGEAR TO THE MAXILLARY COMPLEX (REVERSE HEADGEAR가 상악골체에 미치는 영향에 관한 유한요소법적 분석)

  • Kim, Joo-Young;Sohn, Byung-Hwa
    • The korean journal of orthodontics
    • /
    • v.15 no.1
    • /
    • pp.7-22
    • /
    • 1985
  • The purpose of this study was to analyze the stress distribution and the displacement in the maxillary complex after the application of the reverse headgear. The direction of force was parallel to the occlusal plane. Orthopedic force,300gm, was applied to the maxilla of the dry human skull in a forward direction. The stress distribution and the displacement within the maxillary Complex was analyzed by a 3-dimensional finite element method. The results were as follows: 1. The stress distribution at the molar region was greater than that at the anterior. 2. The stress distribution at the lateral side of the premaxilla was greater than that at the middle aide, especially high stress was noted at the canine eminence. 9. Compressive stress was noted only at the frontozygomatic suture of the zygomatic arch. 4. A forward, upward, and sideward displacement was noted at the entire nodal points of the zygomaticomaxillary suture portion. A displacement with a slight rotation was observed on the transverse palatine suture. 5. The maximum stress was observed at the lateral side of the maxillary tuberosity area, and generally the forward and downward displacement was noted at all this area.

  • PDF

An Electromyographic Analysis of Back muscle Activity when Subjects are Lifting Static Loads in One Hand (정적 부하의 비대칭적 적용에 따른 등 근육의 근전도 분석)

  • Kim, Tae-Young;Park, Eun-Young;Lee, Eung-Sang
    • Physical Therapy Korea
    • /
    • v.4 no.1
    • /
    • pp.78-86
    • /
    • 1997
  • Back muscles play an important role in protecting the spine. Epidemiological studies have shown that loads imposed on the human spine during daily living play a significant role in the onset of low back pain. No previous study has attempted to correlate the response of the trunk musculature with the type of external load. The purpose of this study was to use surface electromyography (EMG) to quantify the relative demands placed on the back muscles while lifting loads in one hand. Forty asymptomatic, twenty year-old subjects stood while lifting loads of 10% of body weight(BW) unilaterally. All EMG data were normalized to a percentage of the EMG voltage produced during no-load standing(%EMG). Our major analysis involved a paired t-test for repeated measures. Of particular note was the fact that the ipsilateral 10% of BW condition produced statistically less % EMG change than did the contralateral 10% of the condition.

  • PDF

Analysis of PSC Box Girder Anchorage Zone using FEM and 2D SUB-3D STM Approach (유한요소법 및 유사 3 차원 스트릿-타이 모델 방법을 이용한 PSC 박스거더 정착부의 해석)

  • Yun, Young-Mook;Kim, Seung-Eock;Oh, Jin-Woo;Park, Jung-Woong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.2
    • /
    • pp.113-129
    • /
    • 2000
  • This study evaluates the behavior and strength of an anchorage zone of the prestressed concrete box girder bridge on the Kyungboo highway railroad using the 2D SUB-3D STM approach and a linear elastic finite element analysis. The 2D SUB-3D STM approach utilizes several two-dimensional sub strut-tie models that represent the compressive and tensile stress flows of each projected plane of the three-dimensional structural concrete in the selection of a three dimensional strut-tie model, evaluation of the effective strengths of the concrete struts, and verification of the geometric compatibility condition and bearing capacity of the critical nodal zones in the selected three-dimensional strut-tie model. The finite element analysis uses an 8-node brick element and the longitudinal prestressing force is considered as the equivalent nodal force. Analysis results show that the 2D SUB-3D STM approach and linear elastic finite element method can be effectively applied to the analysis and design of three-dimensional structural concrete including a prestressed concrete box girder anchorage zone.

  • PDF

Examination of Stress Changes Depending on the Size of the Repaired Part of a Partially Repaired RC Beam (부분보수한 RC보의 보수부 크기에 따른 응력 변화 검토)

  • Kwon, Hyeong-Soon;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.47-48
    • /
    • 2023
  • Reinforced concrete structures are an integrated structure in which reinforcing bars are placed on the tensile side of the beam to compensate for concrete that is strong in compression but weak in tension, so that the concrete receives compressive force and the reinforcing bars receive tensile force. It is durable, fire-resistant, economical, and adapts to the shape and dimensions of the structure. It has been widely used for a long time because it can be made freely without restrictions. However, reinforced concrete structures have the disadvantage that cracks occur easily, so they are repaired using a cross-sectional construction method. During this process, problems such as the repair part falling off occurred, so in order to solve the problem, stress changes due to changes in the size of the repair part were examined. As a result, based on the elastic modulus ratio of 1.0, the stress tended to increase as the size of the repair part decreased when it was less than 1.0, and the opposite tendency was seen when it was more than 1.0. This is believed to be due to an increase in the area of the part with a large elastic modulus.

  • PDF

The Effect of Moisture Content on the Compressive Properties of Korean Corn Kernel (함수율(含水率)이 옥수수립(粒)의 압축특성(壓縮特性)에 미치는 영향(影響))

  • Lee, Han Man;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.1
    • /
    • pp.113-122
    • /
    • 1986
  • In order to promote mechanization of corn harvesting in Korea, this study was conducted to find out the effect of moisture content on compressive properties such as force, deformation, energy and modulus of stiffness to the bioyield and the rupture point for Korean corn kernel. In this study, the loading positions of corn were flat, edge, longitude and the moisture contents were about 13, 17, 21, 25% in wet basis. The compression test was carreied out with flat plate by use of dynamic straingage for three varieties of Korean corn under quasi-static force when the loading rate was 1.125mm/min. The results of this study are summarized as follows; 1. When the moisture content of corn ranged from 12.5 to 24.5 percent, at flat position, the bioyied force was in the range of 13.63-26.73 kg and the maximum compressive strength was in the range of 21.55-47.65kg. Their values were reached minimum at about 17% and maximum at about 21% moisture content. The bioyield force was in the range of 13.58-6.70kg at edge position and the maximum compressive strength which was 16.42 to 7.82kg at edge position was lower than that which was 18.55-9.05kg at longitudinal position. 2. Deformation of corn varied from 0.43 to 1.37 mm at bioyield point and from 0.70 to 2.66mm at rupture point between 12.5 to 24.5% moisture content. As the moisture content increased, deformation was increased. 3. The moduli of resilience and toughness of corn ranged from 2.60 to 8.57kg. mm and from 6.41 to 34.36kg. mm when the moisture content ranged from 12.5 to 24.5 percent, respectively. As the moisture content increased, the modulus of toughness was increased at edge position and decreased at longitudinal position. And their values were equal each other at 22-23% moisture content. 4. The modulus of stiffness was decreased with increase in the moisture content. Its values ranged from 32.07 to 5.86 kg/mm at edge position and from 42.12 to 18.68kg/mm at flat position, respectively. Also, the values of Suweon 19 were higher than those of Buyeo. 5. It was considered that the compressive properties of corn at flat position were more important on the design data for corn harvesting and processing machinery than those of edge or longitudinal position. Also, grinding energy would be minimized when a corn was processed between about 12.5 to 17% moisture content and corn damage would be reduced when a corn was handled between about 19 to 24% moisture content in wet basis.

  • PDF

Method for measuring 3-axis cutting force of a pick cutter using the single-axis load cell array (1축 로드셀 배열을 사용한 픽 커터의 3축 절삭력 측정방법)

  • Kang, Hoon;Jang, Jin-Seok;Park, Jin-Young;Cho, Jung-Woo;Jung, Myeong-Sik;Lee, Jae-Wook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.749-755
    • /
    • 2016
  • A new method for measuring the 3-axis cutting forces of a pick cutter by substituting costly 3-D load cells is proposed in this paper. The proposed cutting force measurement method is capable of estimating the 3-axis cutting forces through mechanical constraints using four single-axis compressive load cells and shoulder bolts. The feasibility of the proposed method was verified by finite element analysis, and the accuracy of the force measurement of the developed force measurement device was investigated by conducting linear rock cutting tests. The tests showed that the new cutting force measurement method is able to measure 3-axis cutting forces with a relative error of approximately 6%. These results imply that the new method could be a suitable alternative to conventional 3-D load cells. In addition, it will allow a significant reduction of approximately 20-30% in the costs required for measuring the cutting force when compared to conventional 3-D load cells.

Influence of Spring Constant at Fixed End on Stability of Beck's Column with Tip Mass (固定端 의 스프링 상수 가 末端質量을 가진 Beck′s Column 의 安定性 에 미치는 영향)

  • 윤한익;김광식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.606-612
    • /
    • 1985
  • On the stability of the Beck's column with a tip mass, the influence of the characteristics of the springs at the fixed end of the column are studied. The equations of motion and boundary conditions of this system are established by using the Hamiton's principle. On the evaluation of the stability of the column, t he effect of the shear deformation and rotatory inertial is considered in calculation. For the maintenance of the stability of the column, it is proved that the constant of the translational spring at the fixed end must be very large while th magnitude of the constant of the rotational spring at the fixed end has no effect. When the constants of the springs at the fixed end are small, it is also proved that the influence of the moment of inertial of the tip mass on the stability of the column are decreased and for the translational spring the degree of the decrease is more and more. Therefore it is found that the characteristics of the springs at the fixed end are very effective elements for the stability of the column when the columns subjected to a compressive follower force are designed.

Analysis of the Uncertainty of Compressive Forces Acting on the Patella by Using Multi-Body Modeling and Muscle Mechanics (다물체 모델링과 근의 특성을 이용한 무릎뼈에 가해지는 압력의 불확실성 추정 연구)

  • NamGoong, Hong;Yoo, Hong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.785-790
    • /
    • 2011
  • The goal of this study is to estimate the force acting on the knee joint in the human body by using the Hilltype muscle model based on a musculoskeletal model of the human lower extremity in the sagittal plane. For estimating the force applied, the human leg is modeled using multi-body modeling. This leg model comprises biarticular muscles acting on two joints of the upper and lower limbs, and the muscles include some of the major muscles such as the hamstring. In order to analyze the uncertainty of the applied forces acting on the knee joint, statistical distributions of human body, leg part, parameters are required and to obtain the parameter's statistical characteristic of the part sample survey method is employed. Finally, by using the sensitivity information of the parameters, the force acting on the knee joint can be estimated.