• Title/Summary/Keyword: Compression Force

Search Result 653, Processing Time 0.025 seconds

BIOMECHANICAL EVALUATION ON BONE REGENERATION IN MANDIBULAR DISTRACTION OSTEOGENESIS COMBINED WITH COMPRESSION STIMULATION (하악골 신장술에서 압축자극을 통한 골 재생방식에 대한 생체 역학적 평가)

  • Heo, June;Kim, Uk-Kyu;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Chung, In-Kyo;Kim, Cheol-Hun;Yun, Seok-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.470-478
    • /
    • 2007
  • The purpose of this study was to investigate the clinical, biomechanical, and histologic changes in new distraction osteogenesis(DO) technique combined with a compression stimulation in accordance to different compression-distraction force ratio. 23 adult male rabbits underwent open-osteotomy at the mandibular body area and a external distraction device was applied. In the control group of 8 rabbits, only a 8 mm of distraction was performed by conventional DO technique. In an experimental group of 15 rabbits, a distraction followed by a compression force was performed according to the ratio of compression-distraction suggested by authors. The rate of experimental group I was set up as a 2 mm compression versus 10 mm distraction and the rate of experimental group II was set up as a 3 mm compression versus 11 mm distraction. All the rabbits were sacrificed for a gross finding, biomechanical, histomorphometric and histologic findings at the time of 55 days from the operation day. The results were as follows: 1. On the gross findings, because all rabbits had a sufficient healing time, every distracted new bone had good bone quality and we could not find any difference among all three groups. 2. In the histologic findings, rapid bone maturation(wide lamellar bone formation in the cancellous and cortical bone areas) was observed in two experimental groups compared to the control group. 3. On the bone density tests, the experimental group II showed higher bone density than the other experimental group and control group(control group-$0,2906g/cm^2$, experimental group I-$0.2961g/cm^2$, experimental group II-$0.3328g/cm^2$). 4. On the biomechanical tests, the experimental group II had significantly higher bone microhardness than the other experimental group and control group(control group-252.7 MPa, experimental group I-263.5 MPa, experimental group II-426.0 MPa). 5. On the microhardness tests, when we compared the hardness ratio of distracted bone versus normal bone, we could find experimental group II had significantly higher hardness ratio than the other experimental group and control group(control group-0.47, experimental group I-0.575, experimental group II-0.80). From this study, we could deduce that the modified distraction osteogenesis method with a compression stimulation might improve the quality of bone regeneration and shorten the consolidation period in comparison with conventional distraction osteogenesis techniques.

Texture characteristics of Angdo Pyun as affected by ingredients (재료배합비에 따른 앵도편의 Texture 특성)

  • 류재영;이효지
    • Korean journal of food and cookery science
    • /
    • v.2 no.1
    • /
    • pp.45-53
    • /
    • 1986
  • This study was conducted to investigate the effects of the properties of sugar (20%, 30%) and starch (l5%, 20%, 25%) to Angdo on Angdo Pyun's preference, texture and color_ Textural characteristics were examined through sensory evaluation, Rheometer. Color test by Color and color difference meter. The properties through sensory evaluation were appearance, color, flavor, hardness, thickness and acceptability. With Rheometer, compression force, work ratio, adhesive work and gumminess were measured. With Color and Color difference meter, L, a ana b were measured. The results were as follows: 1. Sensory evaluation indicated that with the increase of starch addition, the Angdo Pyun maintained a worse apperance and got hardened and thickened. As the amount of suger increased, the Angdo fyun maintained better in color and flavor as well as its acceptability. 2. Rheometer measurement indicated that a compression force, work ratio, adhesive work and gumminess tended to increase, as the starch proportion increased. As the amount of sugar increased, the Angdo Pyun maintained a greater adhesive work, work ratio and gumminess. 3. Color and Color difference meter indicated that figure L ana a tended to increase and b, ΔE and ΔC decrease, as the starch proportion increased. 4. In the analysis of correlation between hardness and compression force, it was found that they are highly related. In view of the above results, it came to the conclusion that Angdo Pyun with the addition of 30% sugar and 15% starch could give the best result among the groups studied.

  • PDF

Study on Shear Strength Characteristic of Steel Particle-sand Mixture Influenced by Magnetic Force (자기력이 적용된 철가루 혼합 사질토의 전단강도특성 연구)

  • Cho, Joong-Ki;Chang, Pyeong-Wook;Kim, Seong-Pil;Heo, Jun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.6
    • /
    • pp.87-92
    • /
    • 2007
  • Strain-stress behavior of soil is of importance in dealing with geo-techniques which relate to bearing capacity, slope stability, earth pressure and many geo-technical problems. So understanding mechanism of the behavior and reinforcing soil to the required state has been an issue for many years. This paper presents the possibility of magnetic force in enhancing shear strength. To analyze the reinforcing effect, triaxial compression tests were performed on two sets of steel-sand mixtures, one of which is influenced by permanent magnet, NdFeB. With magnetic force under 50 kPa confining pressure, maximum shear strengths increased according to steel percentages but under 100 kPa, no significant changes in maximum shear strengths occurred. Therefore the analysis by Mohr's circles indicates that magnetic force converts the shearing characteristics of sand into those of clay.

ANALYSIS OF STRESS DEVELOPED WITHIN THE SUPPORTING TISSUE OF ABUTMENT TOOTH WITH INDIRECT RETAINER ACCORDING TO VARIOUS DESIGNS OF DIRECT RETAINER AND DECREE OF BONE RESORPTION (편측성 후방연장 국소의치에서 직접유지장치의 설계와 지대치 골흡수에 따른 간접유지장치 지대치 주위조직에 발생하는 응력분석)

  • Lee, Suk-Hyun;Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.150-165
    • /
    • 1998
  • For the purpose of evaluating the effect of both direct retainer design and bony absorption degree around abutment of indirect retainer on the supporting tissue of abutment of indirect retainer, dislodging force was transmitted to unilateral distal extension RPD bases. Analysis of stress distributed within the supporting tissue around abutment of indirect retainer was carried out. Using three-dimensional photoelastic stress analysis method and the conclusion is a follows. 1. According to the extent of force which the direct retainer of the most distal abutment tooth, the amount of force transmitted to the abutment tooth of indirect retainer was small. 2. Of all the cases, Mandibular first premolar which was used abutment tooth of indirect retainer, buccal, mesial and distal sides represented compression stress and lingual side represented tensile stress. 3. The more bone resorption of abutment tooth of indirect retainer, the more distortion of buccal and distal side of abutment tooth was existed and the extent of compression stress which was existed and distal side to abutment tooth was large. 4. When the alveolar bone around the abutment with indircet retainer is normal. The amount of force transmitted on abutment with indirect retainer was small in the order of Akers clasp, RPA clasp, RPI clasp. 5. When the alveolar bone around the abutment with indirect retainer has been absorbed 20% and 30%, the amount of force transmitted on abutment with indirect retainer was small in the order of RPA calsp, RPI clasp, Akers clasp. 6. When denture is displaced, shape of the direct retainer reciprocating abutment affect much the function of indirect retainer.

  • PDF

Material Characteristics of Dental Implant System with In-Vitro Mastication Loading

  • Jeong, Tae-Gon;Jeong, Yong-Hun;Lee, Su-Won;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Gang, Gwan-Su
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.72-72
    • /
    • 2018
  • A dynamic fatigue characteristic of dental implant system has been evaluated with applying single axial compressive shear loading based on the ISO 14801 standard. For the advanced dynamic fatigue test, multi-directional force and motion needed to be accompanied for more information of mechanical properties as based on mastication in oral environment. In this study, we have prepared loading and motion protocol for the multi-directional fatigue test of dental implant system with single (Apical/Occlusal; AO), and additional mastication motion (Lingual/Facial; LF, Mesial/Distal; MD). As following the prepared protocol (with modification of ISO 14801), fatigue test was conducted to verify the worst case results for the development of highly stabilized dental implant system. Mechanical testing was performed using an universal testing machine (MTS Bionix 858, MN, USA) for static compression and single directional loading fatigue, while the multi-directional loading was performed with joint simulator (ADL-Force 5, MA, USA) under load control. Basically, all mechanical test was performed according to the ISO 14801:2016 standard. Static compression test was performed to identify the maximum fracture force with loading speed of 1.0 mm/min. A dynamic fatigue test was performed with 40 % value of maximum fracture force and 5 Hz loading frequency. A single directional fatigue test was performed with only apical/occlusal (AO) force application, while multi directional fatigue tests were applied $2^{\circ}$ of facial/lingual (FL) or mesial/distal (MD) movement. Fatigue failure cycles were entirely different between applying single-directional loading and multi-directional loading. As a comparison of these loading factor, the failure cycle was around 5 times lower than single-directional loading while applied multi-directional loading. Also, the displacement change with accumulated multi-directional fatigue cycles was higher than that of single directional cycles.

  • PDF

The Effect of External Pelvic Compression on Shoulder and Lumbopelvic Muscle sEMG and Strength of Trunk Extensor During Push Up Plus and Deadlift Exercise (푸쉬업플러스와 데드리프트 운동 시 골반압박이 견관절과 요골반부 주위근의 근활성도와 체간 신전근 근력에 미치는 영향)

  • Huang, Tian-zong;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.25 no.3
    • /
    • pp.1-11
    • /
    • 2018
  • Background: Lumbopelvic stability is highly important for exercise therapy for patients with low back pain and shoulder dysfunction. It can be attained using a pelvic compression belt. Previous studies showed that external pelvic compression (EPC) enhances form closure by reducing sacroiliac joint laxity and selectively strengthens force closure and motor control by reducing the compensatory activity of the stabilizer. In addition, when the pelvic compression belt was placed directly on the anterior superior iliac spine, the laxity of the sacroiliac cephalic joint could be significantly reduced. Objects: This study aimed to compare the effects of EPC on lumbopelvic and shoulder muscle surface electromyography (EMG) activities during push-up plus (PUP) and deadlift (DL) exercise, trunk extensor strength during DL exercise. Methods: Thirty-eight subjects (21 men and 17 women) volunteered to participate in this study. The subjects were instructed to perform PUP and DL with and without the EPC. EMG data were collect from serratus anterior (SA), pectoralis major (PM), erector spinae (ES), and multifidus (MF). Trunk extensor strength were tested in DL exercise. The data were collected during 3 repetitions of all exercise and the mean of root mean square was used for analysis. Results: The EMG activities of the SA and PM were significantly increased in PUP with pelvic compression as compared with PUP without pelvic compression (p<.05). In DL exercise, a significant improvement in trunk extensor strength was observed during DL exercise with pelvic compression (p<.05). Conclusion: The results of this study indicate that lumbopelvic stabilization reinforced with external pelvic compression may be propitious to strengthen PUP in more-active SA and PM muscles. Applying EPC can improve the trunk extensor strength during DL exercise. Our study shows that EPC was beneficial to improve the PUP and DL exercise efficiency.

Development of a Measurement System of the Transferred Pressure from Intermittent Pneumatic Compression Device (간헐적공기압박장치의 전달압력 측정시스템 개발)

  • Lee, Wonhee;Seo, Jong Hyun;Kim, Jun;Kang, Seung Ho;Kim, Gook Han;Chung, Seung Hyun;Kim, Kwang Gi;Kang, Hyun Guy
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.39-45
    • /
    • 2016
  • A pressure measurement system was developed to verify magnitude and position of transferred pressure on the body surface during the intermittent pneumatic compression (IPC) which is one of the most well-known methods for the prevention of deep vein thrombosis (DVT). Eighty force sensing resistors (FSR) were arranged on a mannequin leg and a hardware controller sensed, digitized, and transferred pressure data every second while IPC was being applied. Finally, sensed pressure data were color coded and visualized on the 3D model with lab-developed software. The pressure data were also saved to files for further analysis. Using this measurement system, the changing pattern of pressure was measured on the mannequin leg by changing both chamber pressure and cuff tightness. As a result, net pressure transferred onto the body surface is dependent on chamber pressure and cuff tightness. Under the same chamber pressure, the tighter a cuff was worn, the wider compressed area was and the shorter compression cycle was. Also transferred pressure was proportional to both chamber pressure and cuff tightness.

Effects of Bonding Conditions on Mechanical Strength of Sn-58Bi Lead-Free Solder Joint using Thermo-compression Bonding Method (열압착 접합 조건에 따른 경·연성 인쇄회로기판 간 Sn-58Bi 무연솔더 접합부의 기계적 특성)

  • Choi, Ji-Na;Ko, Min-Kwan;Lee, Sang-Min;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.2
    • /
    • pp.17-22
    • /
    • 2013
  • We investigated the optimum bonding conditions for thermo-compression bonding of electrodes between flexible printed circuit board(FPCB) and rigid printed circuit board(RPCB) with Sn-58Bi solder as interlayer. In order to figure out the optimum bonding conditions, peel test of FPCB/RPCB joint was conducted. The peel strength was affected by the bonding conditions, such as temperature and time. The fracture energies were calculated through F-x (Force-displacement) curve during peel test and the relationships between bonding conditions and fracture behaviors were investigated. The optimum condition for the thermo-compression bonding with Sn-58Bi solder was found to be temperature of $195^{\circ}C$ and time of 7 s.

Prediction of the Spinal Load during Static Loading Conditions using EMG model and Three Optimization models (정적 부하 작업에서 EMG 모델과 세가지 최적화 모델을 이용한 척추 부하 평가)

  • Song, Young Woong;Chung, Min Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.61-70
    • /
    • 2005
  • This study investigated the spinal loads(L5/S1 disc compression and shear forces) predicted from four biomechanical models: one EMG model and three optimization models. Three objective functions used in the optimization models were to miminize 1) the cubed muscle forces : MF3, 2) the cubed muscle stress : MS3, 3) maximum muscle intensity : MI. Twelve healthy male subjects participated in the isometric voluntary exertion tests to six directions : flexion/extension, left/right lateral bending, clockwise/ counterclockwise twist. EMG signals were measured from ten trunk muscles and spinal loads were assessed at 10, 20, 30, 40, 50, 60, 70, 80, 90%MVE(maximum voluntary exertion) in each direction. Three optimization models predicted lower L5/S1 disc compression forces than the EMG model, on average, by 31%(MF3), 27%(MS3), 8%(MI). Especially, in twist and extension, the differences were relatively large. Anterior-posterior shear forces predicted from optimization models were lower, on average, by 27%(MF3), 21%(MS3), 9%(MI) than by the EMG model, especially in flexion(MF3 : 45%, MS3 : 40%, MI : 35%). Lateral shear forces were predicted far less than anterior-posterior shear forces(total average = 124 N), and the optimization models predicted larger values than the EMG model on average. These results indicated that the optimization models could underestimate compression forces during twisting and extension, and anterior-posterior shear forces during flexion. Thus, future research should address the antagonistic coactivation, one major reason of the difference between optimization models and the EMG model, in the optimization models.

Effects of 3D Compression Pants and Kinesio Taping on Isokinetic Muscular Function of Leg During Knee Joint Flexion Motion (3D 밀착형 팬츠와 키네시오 테이핑이 무릎관절의 등속성 굴곡 운동 시 하지의 근기능에 미치는 영향)

  • Choi, Jiyoung;Park, Heegeun;Lee, Wanglok;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.2
    • /
    • pp.240-257
    • /
    • 2016
  • This study determines the effect of 3D compression pants and Kinesio taping on muscular function of the leg during knee joint flexion and extension. Eight males participated in the experiment, wearing basic pants (BP), Kinesio taping on bare skin (KT), 3D compression pants with (KTP) and without Kinesio taping (CP). The test protocol for isokinetic muscular function was composed of four sets at three angular velocities (60, 180, $240^{\circ}/sec$) using Cybex 660. Peak torque and work per repetition of the lower limbs of eight males were analyzed from the result of Cybex. Agility and power of the subjects were examined from side step and sergeant jump. Peak torque, average power, work per repetition, force decay time of subjects wearing CP and KTP were significantly better than BP or KT, especially at low angular velocity of $60^{\circ}/sec$. The time to generate peak torque of subjects wearing BP was the longest, while the force-decay time of BP was the shortest. The application of Kinesio tape on skin did not increase muscle peak torque, work and power, but did shorten the time to generate peak torque.