• Title/Summary/Keyword: Compressed method

Search Result 781, Processing Time 0.03 seconds

Surgical Treatment of Varicose Vein - TIPP(Transilluminated Powered Phlebectomy) - (정맥류 환자의 수술적 치료 -광투시 전도형 정맥적출요법-)

  • 이교준;김해균;정은규;강두영
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.144-148
    • /
    • 2002
  • The present study was done to determine the efficacy and safety of varicose vein removal using a minimally invasive, powered vein-extracting device with cutaneous transillumination and tumescent anesthesia techniques and then compared this to a retrospective group of conventional phlebectomy operations. There were 133 limbs in 104 patients(72 women, 32 men) treated with the use of the vein extractor aided by transcutaneous illumination. The hydrodissection was performed with Trivex™ Irrigated illuminator(Smith & Nephe $w^{ R}$) system using normal saline after the 2~3mm sized skin incision. Varicose clusters were extracted by the use of TriveTM esector(Smith & Nephe $w^{ R}$) system under transillumination. After the varisoce vein extraction, the operation area was compressed with surgical pad for bleeding control. The complication rate was 3.84% The mean number of incisions was 3.24 and mean operative time per limb was 65.9 minutes. The mean hospitalization was 1.86 days. The varicose vein extraction using transilluminated powered phlebectomy(TIPP) is a safe, efficacious and cosmetically satisfactory method. The procedure decreases the operating time and the number of incisions required to remove varicose clusters. Further evaluation and long term follow up will be necessary to determine the recurrence rate and long termcomplications.to determine the recurrence rate and long termcomplications.

Multiplexing of UHDTV Based on MPEG-2 TS (MPEG-2 TS 기반의 UHDTV 다중화)

  • Jang, Euy-Doc;Park, Dong-Il;Kim, Jae-Gon;Lee, Eung-Don;Cho, Suk-Hee;Choi, Jin-Soo
    • Journal of Broadcast Engineering
    • /
    • v.15 no.2
    • /
    • pp.205-216
    • /
    • 2010
  • In this paper, a method of MPEG-2 Transport Stream (TS) multiplexing for Ultra HDTV (UHDTV) and its design and implementation as a SW tool is described. In practice, UHD video may be divided into several HD videos and each video is encoded in parallel. Therefore, it is necessary to synchronize and multiplex multiple bitstreams encoding each HD video for transmitting and storing UHD video. In this paper, it is assumed that 4 HD videos partitioning a UHD spatially are encoded as H.264/AVC and two 5.0 channel audios are encoded by AC-3. Therefore, 4 H.264/AVC elementary streams (ESs) and 2 AC-3 ESs is mainly considered in the TS multiplexing of UHD. For the carriage of H.264/AVC and AC-3 over MPEG-2 TS, PES packetization and TS multiplexing are designed and implemented based on the extended specification of the MPEG-2 Systems and ATSC (Digital audio compressed standard), respectively. The implemented UHD TS multiplexing tool emulates real time HW operation in the time unit corresponding to the duration of one TS packet transmission in a given TS rate. In particular, in order to satisfy the timing model, the buffers defined in the TS System Target Decoder (T-STD) are monitored and their statuses are considered in the scheduling of TS multiplexing. For UHD multiplexing, two kinds of multiplexing structures, which are UHD re-multiplexing and UHD program multiplexing, are implemented and their strength and weakness are investigated. The developed UHD TS multiplexing tool is tested and verified in terms of the syntax and semantics conformance and functionalities by using a commercial analyzer and real-time presentation tools.

Adaptive Strip Compression for Panorama Video Streaming (파노라마 동영상 스트리밍을 위한 적응적 스트립 압축 기법)

  • Kim Bo Youn;Jang Kyung Ho;Koo Sang Ok;Jung Soon Ki
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.1_2
    • /
    • pp.137-146
    • /
    • 2006
  • Traditional live video streaming systems support the limited field of view (FOV) of image to the remote users. A server system based on the pan/tilt camera provides a user with wide view by changing the view direction of the camera mechanically. But, when many clients try to access to the server, this system can not offer their own view to every user simultaneously, and moreover it has the delay by camera motion. In order to offer wide views to several users, we propose new streaming system using the panorama image that has wide view. Our system is a kind of implementation of software pan/tilt camera. The server acquires panorama video and sends a part of the video to clients. Then, each client can control their own view. We need the effective way to reduce the average transmission data size and server burden to the compression because generally the full size of panorama video is too big to be served by the real-time streaming. To solve this problem, we propose an strip-based video compression and adaptive transmission of the compressed multiple strip videos. Experimental results show that our system can be adapted quickly to the change of view and the number of clients. Furthermore, proposed method effectively reduce the transmission data.

Characterization of Carbonized MDF by Scanning Electron Microscopy and X-ray diffraction (주사전자현미경 및 X선회절법에 의한 탄화 MDF의 특성)

  • Lee, Seon-Hwa;Park, Sang-Bum;Kwon, Sung-Min;Park, Jong-Young;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.208-215
    • /
    • 2009
  • As a fundamental study to develop absorbing materials on harmful volatile organic compounds (VOC) such as formaldehyde, structural and crystalline characteristics of MDF carbonized at different temperatures were examined by a scanning electron microscope and an X-ray diffraction method. Fibers in surface layer of MDFs showed more compressed morphology than those in middle layer of MDFs, but the porosity of MDFs increased with increasing the carbonized temperature. The wrinkle shape was frequently surfaces of cell walls was more severe than that at the lumina of cells. The shape of pits in the fibers of carbonized MDFs were hardly changed. The cell walls of MDFs carbonized at $400^{\circ}C$ and over showed an amorphous-like structure without cell layering. X-ray diffratograms from the MDFs carbonized at $400^{\circ}C$ showed a trace of crystalline cellulose. On the other hand, an amorphous diffraction pattern from carbons was obtained with the MDFs carbonized at $1,000^{\circ}C$.

Impact of the Exclusive Median Bus Lane System on Air Pollution Concentrations in Seoul, Korea (서울시 중앙버스전용차로 도입의 부가적인 대기오염 영향성 평가)

  • Baik, Yeon-Ju;Kim, Da-Wool;Kwon, Hye-Young;Kim, Youngkook;Kim, Sun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.542-553
    • /
    • 2018
  • Since many previous studies reported the health effect of air pollution and indicated traffic as a major pollution source, significant policy efforts have been made to control traffic to reduce air pollution. However, there have been few studies that evaluated such policy implementation. In Seoul, Korea, the exclusive median bus lane system was implemented in 2004, and the metropolitan government applied air pollution reduction policies such as conversion of diesel buses to compressed natural gas buses and installation of emission control devices. This paper aimed to investigate the impact of the exclusive median bus lane system on air pollution reduction. Using hourly concentrations of particulate matter ($PM_{10}$) and nitrogen dioxide ($NO_2$) measured at 131 regulatory monitoring sites in Seoul and Gyeonggi-do for 2001-2014, we calculated annual and daily average concentrations at each site. We assessed the impact of the policy using differences-in-differences analysis by annual and daily average models after adjusting for geographic and/or meteorological variables. This method divides population into treatment and control groups with and without policy application, and compares the difference between the two time periods before and after the policy implementation in the treatment group with the difference in the control group. We classified all monitoring sites into treatment and control groups using two definitions: 1) Seoul vs. Gyeonggi-do; 2) within vs. outside 300 meters from the median bus lane. Pre- and post-policy periods were defined as 2001-2005 and 2006-2014, and 2004 and 2014 in the annual and daily models, respectively. The decrease in $PM_{10}$ concentrations between the two periods across monitoring sites in the treatment group was larger by $1.73-5.88{\mu}g/m^3$ than in the control group. $NO_2$ also showed the decrease without statistical significance. Our findings suggest that an efficient public transport policy combined with pollution abatement policies can contribute to reduction in air pollution.

Analysis of Hydrodynamic Similarity in Three-Phase Fluidized Bed Processes (삼상유동층 공정에서 수력학적 Similarity 해석)

  • Lim, Ho;Lim, Hyun-Oh;Jin, Hae-Ryoung;Lim, Dae-Ho;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.790-797
    • /
    • 2011
  • Hydrodynamic similarity was analyzed by employing scaling factor in three phase fluidized beds. The scaling factor was defined based on the holdups of gas, liquid and solid particles and effectivity volumetric flux of fluids between the two kinds of fluidized beds with different column diameter. The column diameter of one was 0.102 m and that of the other was 0.152 m. Filtered compressed air, tap water and glass bead of which density was 2,500 kg/$m^3$ were used as gas, liquid and solid phases, respectively. The individual phase holdups in three phase fluidized beds were determined by means of static pressure drop method. Effects of gas and liquid velocities and particle size on the scaling factors based on the holdups of each phase and effective volumetric flux of fluids were examined. The deviation of gas holdup between the two kinds of three phase fluidized beds decreased with increasing gas or liquid velocity but increased with increasing fluidized particle size. The deviation of liquid holdup between the two fluidized beds decreased with increasing gas or liquid velocity or size of fluidized solid particles. The deviation of solid holdup between the two fluidized beds increased with increasing gas velocity or particle size, however, decreased with increasing liquid velocity. The deviation of effective volumetric flux of fluids between the two fluidized beds decreased with increasing gas velocity or particle size, but increased with increasing liquid velocity. The scaling factor, which was defined in this study, could be effectively used to analyze the hydrodynamic similarity in three phase fluidized processes.

Effect of Flow Rates of Feed and Sweep Gas on Oxygen Permeation Properties of Ba0.5Sr0.5Co0.8Fe0.2O3-δ Membrane (공급가스 및 스윕가스 유량에 따른 Ba0.5Sr0.5Co0.8Fe0.2O3-δ 분리막의 산소투과특성)

  • Park, Se Hyung;Sonn, Jong Suk;Lee, Hong Joo;Park, Jung Hoon
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.407-411
    • /
    • 2015
  • Dense ceramic membranes have been prepared using the commercial perovsikite $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$, powders synthesized by the solid state reaction method. The as-synthesized powders were compressed into disks with 1.0 mm of thickness and the disk was sintered at $1,100^{\circ}C$ for 2 hr. The oxygen permeation flux of $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ membrane increased with the increasing temperature and oxygen partial pressure. The activation energy for oxygen permeation was increased with the increasing oxygen partial pressure. Oxygen permeation flux at $950^{\circ}C$ were measured at various flow rates of feed and sweep gas. It has been demonstrated that oxygen permeability increased at elevated flow rates of both gases, but the sweep gas is more influential.

A Blind Watermarking Algorithm using CABAC for H.264/AVC Main Profile (H.264/AVC Main Profile을 위한 CABAC-기반의 블라인드 워터마킹 알고리즘)

  • Seo, Young-Ho;Choi, Hyun-Jun;Lee, Chang-Yeul;Kim, Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2C
    • /
    • pp.181-188
    • /
    • 2007
  • This paper proposed a watermark embedding/extracting method using CABAC(Context-based Adaptive Binary Arithmetic Coding) which is the entropy encoder for the main profile of MPEG-4 Part 10 H.264/AVC. This algorithm selects the blocks and the coefficients in a block on the bases of the contexts extracted from the relationship to the adjacent blocks and coefficients. A watermark bit is embedded without any modification of coefficient or with replacing the LSB(Least Significant Bit) of the coefficient with a watermark bit by considering both the absolute value of the selected coefficient and the watermark bit. Therefore, it makes it hard for an attacker to find out the watermarked locations. By selecting a few coefficients near the DC coefficient according to the contexts, this algorithm satisfies the robustness requirement. From the results from experiments with various kinds and various strengths of attacks the maximum error ratio of the extracted watermark was 5.02% in maximum, which makes certain that the proposed algorithm has very high level of robustness. Because it embeds the watermark during the context modeling and binarization process of CABAC, the additional amount of calculation for locating and selecting the coefficients to embed watermark is very small. Consequently, it is highly expected that it is very useful in the application area that the video must be compressed right after acquisition.

Image Processing of Pseudo-rate-distortion Function Based on MSSSIM and KL-Divergence, Using Multiple Video Processing Filters for Video Compression (MSSSIM 및 쿨백-라이블러 발산 기반 의사 율-왜곡 평가 함수와 복수개의 영상처리 필터를 이용한 동영상 전처리 방법)

  • Seok, Jinwuk;Cho, Seunghyun;Kim, Hui Yong;Choi, Jin Soo
    • Journal of Broadcast Engineering
    • /
    • v.23 no.6
    • /
    • pp.768-779
    • /
    • 2018
  • In this paper, we propose a novel video quality function for video processing based on MSSSIM to select an appropriate video processing filter and to accommodate multiple processing filters to each pixel block in a picture frame by a mathematical selection law so as to maintain video quality and to reduce the bitrate of compressed video. In viewpoint of video compression, since the properties of video quality and bitrate is different for each picture of video frames and for each areas in the same frame, it is difficult for the video filter with single property to satisfy the object of increasing video quality and decreasing bitrate. Consequently, to maintain the subjective video quality in spite of decreasing bitrate, we propose the methodology about the MSSSIM as the measure of subjective video quality, the KL-Divergence as the measure of bitrate, and the combination method of those two measurements. Moreover, using the proposed combinatorial measurement, when we use the multiple image filters with mutually different properties as a pre-processing filter for video, we can verify that it is possible to compress video with maintaining the video quality under decreasing the bitrate, as possible.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.