• Title/Summary/Keyword: Composites materials

Search Result 4,784, Processing Time 0.027 seconds

Evaluation of Microhardness of Bulk-base Composite Resins According to the Depth of Cure (Bulk-base 복합 레진의 중합 깊이에 따른 미세경도 평가)

  • No, Yoomi;Shin, Bisol;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.335-340
    • /
    • 2017
  • Composite resin becomes an essential material in pediatric dentistry. However, incremental filling of composite resin to minimize the polymerization shrinkage takes time. To reduce the polymerization shrinkage, clinicians and researchers have focused on bulk-filling materials. Bulk-base composite resin is newly introduced as bulk-filling composite resin. The purpose of this study was to evaluate microhardness profile of bulk-base composite resin according to the depth of cure. A high flow bulk-base material and a low flow bulk-base material were used for experimental group, and a conventional composite resin was used for control group. Each group consist of 20 specimens, $3.5{\times}3.5{\times}5.0mm$ mold was used to make specimen. Specimens were sectioned at the 2 mm and the 3 mm depth with milling machine. Microhardness profile was measured at the surface, 2 mm depth, 3 mm depth, and 4 mm depth. Microhardness of control group showed statistically significant difference (p < 0.05) according to the polymerization depth. In contrast, experimental group showed no statistically significant difference, except between 0 mm and 4 mm at HFB, 0 mm and 2 mm, 0 mm and 3 mm at MFB. At the surface and the 2 mm depth, the control group showed higher microhardness than the experimental groups (p < 0.05). However, at the 4 mm depth, the experimental groups showed significantly higher microhardness (p < 0.05). The results from this study, the bulk-base composite resin showed higher microhardness at the 4 mm and lower microhardness at the surface and the 2 mm depth. Therefore, if bulk-base resin overcomes the mechanical weakness, it could be considered using in pediatric dentistry.

THE EFFECTS OF VARIOUS CURING LIGHT SOURCES ON THE MICROHARDNESS OF LIGHT-ACTIVATED RESTORATIVE MATERIALS (다양한 광원에 의한 광중합형 수복물질의 미세경도에 관한 연구)

  • Choi, Nam-Ki;Yang, Kyu-HO;Kim, Seon-Mi;Choi, Choong-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.634-643
    • /
    • 2005
  • The aim of this study is to evaluate the effects of blue light emitting diode (LED) Light Curing Units (FreeLight 2, L.E.Demetron I, Ultra-Lume 5) on the microhardness of three resin composites (Z250, Point 4, Dyract AP) and to determine their optimal curing time. Samples were made using acrylic molds $(2.0mm{\times}3mm)$ of each composite. All samples were prepared over a Mylar strip placed on a flat glass surface. After composite placement on the molds, the top surface was covered with another Mylar strip and a glass slab was gently pressed over it. The times of irradiation were as follows: Elipar TriLight, 40 s; Elipar FreeLight 2. L.E.Demetron I, and Ultra-Lume 5, 10s, 20s, 40s, respectively. Mean hardness values were calculated at the top and bottom for each group. ANOVA and Sheffe's test were used to evaluate the statistical significance of the results. Results showed that FreeLight 2, Ultra-Lume 5, and L.E.Demetron I were able to polymerize point 4 in 20 seconds to a degree equal to that of the halogen control at 40 seconds. FreeLight 2 and L.E.Demetron I were able to polymerize Z250 in 10 seconds to a degree equal to that of the halogen control at 20 seconds. FreeLight 2 and L.E.Demetron I were able to polymerize Dyract AP in 10 seconds to a degree equal to that of the halogen control at 40 seconds. The commercially available LED curing lights used in this study showed an adequate microhardness with less than half of the exposure time of a halogen curing unit.

  • PDF

Effect of cavity shape, bond quality and volume on dentin bond strength (와동의 형태, 접착층의 성숙도, 및 와동의 부피가 상아질 접착력에 미치는 영향)

  • Lee, Hyo-Jin;Kim, Jong-Soon;Lee, Shin-Jae;Lim, Bum-Soon;Baek, Seung-Ho;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.450-460
    • /
    • 2005
  • The aim of this study was to evaluate the effect of cavity shape, bond quality of bonding agent and volume of resin composite on shrinkage stress developed at the cavity floor. This was done by measuring the shear bond strength with respect to iris materials (cavity shape , adhesive-coated dentin as a high C-factor and Teflon-coated metal as a low C-factor), bonding agents (bond quality: $Scotchbond^{TM}$ Multi-purpose and Xeno III) and iris hole diameters (volume; 1mm or 3mm in $diameter{\times}1.5mm$ in thickness). Ninety-six molars were randomly divided into 8 groups ($2{\times}2{\times}2$ experimental setup). In order to simulate a Class I cavity, shear bond strength was measured on the flat occlusal dentin surface with irises. The iris hole was filled with Z250 restorative resin composite in a bulk-filling manner. The data was analyzed using three-way ANOVA and the Tukey test. Fracture mode analysis was also done When the cavity had high C-factor, good bond quality and large volume, the bond strength decreased significantly The volume of resin composite restricted within the well-bonded cavity walls is also be suggested to be included in the concept of C-factor, as well as the cavity shape and bond quality. Since the bond quality and volume can exaggerate the effect of cavity shape on the shrinkage stress developed at the resin-dentin bond, resin composites must be filled in a method, which minimizes the volume that can increase the C-factor.

Effect of polishing methods on color change by water absorption in several composite resins (여러 복합레진에서 수분 흡수에 의한 색변화에 연마가 미치는 영향)

  • Kim, Hye Jin;Kim, Mi-yeon;Song, Byung-chul;Kim, Sun-ho;Kim, Jeong-hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the influence of polishing methods on the color stability of composite resins. Materials and Methods: Two bulk-fill and four conventional resin composites were filled in cylindrical molds (6 mm diameter, 4 mm height) and light-cured. The specimens were stored in $34^{\circ}C$ distilled water for 24 h. Spectrophotometer was used to determine the color value according to the CIE $L^*a^*b^*$ color space. Each group was divided into three groups according to polishing methods (n = 5). Group 1 was control group (Mylar strip group), group 2 was polished with PoGo, and group 3 was polished with Sof-Lex Spiral wheels. Color evaluation was performed weekly for 4 weeks after immersion in $34^{\circ}C$ distilled water. The results were analyzed by generalized least squares method (P < 0.05). Results: Generalized least squares analysis revealed that Sof-Lex Spiral wheels group showed the significantly lower ${\Delta}E$ values compared to PoGo and control group (P < 0.05). The ${\Delta}E$ values of polished group showed the significantly lower than the ${\Delta}E$ values of unpolished group (P < 0.05). Regarding color changes of composite resins, there was no significant difference between the ${\Delta}E$ values of Filtek Z250 and Filtek Z350 XT Universal restorative in all time intervals (P < 0.05). Tetric N-Ceram Bulk Fill showed the significantly lower ${\Delta}E$ values compared to other composite resins in 1, 2, 3 weeks (P < 0.05). Conclusion: Within the limitations of this study, polishing methods influence the color stabilities of composite resins. The group polished with Sof-Lex Spiral Wheels showed more resistance to discoloration than group polished with PoGo.