• Title/Summary/Keyword: Composite grid

Search Result 135, Processing Time 0.032 seconds

Static behavior of bolt connected steel-concrete composite beam without post-cast zone

  • Xing, Ying;Zhao, Yun;Guo, Qi;Jiao, Jin-feng;Chen, Qing-wei;Fu, Ben-zhao
    • Steel and Composite Structures
    • /
    • v.38 no.4
    • /
    • pp.365-380
    • /
    • 2021
  • Although traditional steel-concrete composite beams have excellent structural characteristics, it cannot meet the requirement of quick assembly and repair in the engineering. This paper presents a study on static behavior of bolt connected steel-concrete composite beam without post-cast zone. A three-dimensional finite element model was developed with its accuracy and reliability validated by available experimental results. The analysis results show that in the normal service stage, the bolt is basically in the state of unidirectional stress with the loss of pretightening can be ignored. Parametric studies are presented to quantify the effects of the post-cast zone, size and position of splicing gap on the behavior of the beam. Based on the studies, suggested size of gap and installation order were proposed. It is also confirmed that optimized concrete slab in mid-span can reduce the requirement of construction accuracy.

Web based Online Real-time Reliability Integrated Information System in Composite Power System Considering Wind Turbine Generators (풍력발전기를 고려한 복합전력계통의 웹기반 온라인 실시간 신뢰도 정보 시스템의 개발)

  • Cho, Kyeong-Hee;Choi, Jae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1305-1313
    • /
    • 2011
  • Web based online real-time reliability integrated information system is asked rapidly for more efficiency and demand response in recent. As the utilization of renewable resources has been receiving considerable attention in recent years, the information system requirement is increased. Specially, the reliability information system is more important for implementing the smart grid. This paper describes architecture of the WORRIS(Web based Online Real-time Reliability Integrated Information System) Version 7.0 system that simulates the reliability indices in composite power system considering wind turbine generators(WTG) developed successfully in this paper. And we had simulated the case study using Jeju island power system data.

A Study on the Radiation Forces Acting on a Submerged-Plate (몰수평판에 작용하는 Radiation 유체력에 관한 연구)

  • Lee, Sang-Min;Kong, Gil-Young;Kim, Chol-Seong
    • Journal of Navigation and Port Research
    • /
    • v.28 no.3
    • /
    • pp.199-205
    • /
    • 2004
  • We have developed a composite grid method for the solution of the radiation problem We divide the domain into two different grids; one is a moving grid system and the other is a fixed grid system. This numerical method is applied to calculation of the radiation forces generated by the submerged plate oscillating near a free surface. The experimental data are compared with the numerical ones obtained by the present method and a linear potential theory. As a result, we can confirm the accuracy of the present method. Finally, Lie have evaluated the effect of nonlinear and viscous damping on the hydrodynamic forces acting on the submerged plate.

Strengthening of Continuous Composite Grid-girder Bridges by Using the Post-tensioning (후긴장을 이용한 연속 합성 격자형교의 보강 방법에 관한 연구)

  • Back, Dong Hoon;Lee, Woo Hyun;Kim, Ki Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.441-455
    • /
    • 1997
  • The need for rehabilitation of the existing bridges is a growing concern in many countries and has been emphasized in various research reports and publications. Many bridges constructed between 1960s and 1970s in Korea were designed for relatively light traffic volumes, speeds and the weight, thus they are inadequate for the present traffic conditions. This together with some design deficiencies, has resulted in deficiencies of various degrees of many bridges. One strengthening method which has significant advantages is the application of external post-tensioning tendons. This paper presents an example of three span continuous composite bridge strenghtened by application of external post-tensioning.

  • PDF

A Study on Radiation Shielding for Grid-stiffened Multi-Functional Composite Structures (격자-강화된 다기능 복합재 구조체의 방사차폐에 관한 연구)

  • Jang, Tae Seong;Rhee, Juhun;Seo, Hyun-Suk;Hyun, Bum-Seok;Kim, Taig Young;Seo, Jung Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.629-639
    • /
    • 2014
  • This paper deals with an alternative multi-functional structures by using grid-stiffened composite structure with excellent bending stiffness and lightweight characteristics which is capable of easy embedding of electrical/electronic circuitry into structure. The enhancement of thermal conduction capability is made by the application of pitch-based carbon fiber. The lightweight radiation spot shielding technique is also proposed for multi-functional structures without conventional housing and the effectiveness of selective radiation shielding is validated through the proton irradiation test.

Carbon Black Containing Micro-Grid Patterned Piezocapacitive Pressure Sensor (탄소분말이 함유된 마이크로 그리드패턴 전기용량형 압력센서)

  • Ma, Sung-Young;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.32 no.5
    • /
    • pp.237-242
    • /
    • 2019
  • In this research, a capacitive pressure sensor (Piezocapacitive Sensor) was fabricated using carbon black powder containing poly-dimethylsiloxane (PDMS) with micro-grid patterned surface. To investigate the effect of carbon black powder and micro-grid pattern on the sensor's performance, various sensors were fabricated with different carbon black powder concentration and grid pattern density. The performances of the developed sensors were compared in terms of operating range and sensitivity.

Estimation of Live Load Moment for Concrete Unfilled Steel Grid Deck Using Main Bearing Bar Distribution Factor (하중분배 계수를 적용한 비충전 강합성 바닥판 활하중 모멘트 산정)

  • Park, Young hoon;Kim, Sung Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1667-1676
    • /
    • 2014
  • Because of the different flexural rigidity between longitudinal and transverse direction, orthotropic plate theory may be suitable for describing the behavior of composite deck. The ratio of flexural rigidity between longitudinal and transverse direction affects the live load moment. Because of the ratio of flexural rigidity of concrete unfilled steel grid deck has a direct relationship with main bearing bar spacing, it is concluded that the study for the distribution factor which is effected by main bearing bar spacing and aspect ratio is needed. In this study, evaluate the live load moment of concrete unfilled steel grid deck using the AASHTO LRFD Bridge Design Specification and presents the distribution coefficient equation for concrete unfilled steel grid deck.

Enhanced Controller Topology for Photovoltaic Sourced Grid Connected Inverters under Unbalanced Nonlinear Loading

  • Sivakumar, P.;Arutchelvi, Meenakshi Sundaram
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.369-382
    • /
    • 2014
  • A growing dynamic electrical demand has created an increasing interest in utilizing nonconventional energy sources like Photovoltaic (PV), wind power, etc. In this context, this paper focuses on the design and development of a composite power controller (CPC) in the decoupled double synchronous reference frame (DDSRF) combining the advantages of direct power control (DPC) and voltage oriented control (VOC) for a PV sourced grid connected inverter. In addition, a controller with the inherent active filter configuration is tested with nonlinear and unbalanced loads at the point of common coupling in both grid connected and autonomous modes of operation. Furthermore, the loss and reactive power compensation due to a non-fundamental component is also incorporated in the design, and the developed DDSRF model subsequently allows independent active and reactive power control. The proposed developed model of the controller is also implemented using MATLAB-Simulink-ISE and a Xilinx system generator which evaluate both the simulated and experimental setups. The simulation and experimental results confirm the validity of the developed model. Further, simulation results for the DPC are also presented and compared with the proposed CPC to further bring out the salient features of the proposed work.

Development of Integrated Composite Suspension wire with Optical Fiber (일체형 광섬유복합조가선(OPSW) 개발 구축)

  • Sone, Young-Cher;Choi, Hyun-Beom;Kim, Byung-Jik;Kim, Young-Tak;Yun, Kyoung-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1122-1127
    • /
    • 2011
  • The thesis here by shows that the extant suspension wire, which is stretched between electric poles to support a variety of communication wires, can be replaced by specially-redesigned cables called OPSW(Composite Suspension Wire with Optical Fiber) which have been devised for the first time in the world so that the functions of both communication and support can be united into one cable which is sure to be successfully installed on site, hence leading to outstanding effects that it can sharply reduce the load applied to electric poles as well as the cost of forthcoming constructions and that it can accordingly make a great contribution to the building of Smart Grid network.

On Evaluation of Stacking Fault in CERP Composite Plates of Using Ultrasonic Images (초음파 이미지를 이용한 CFRP 복합적층판의 적층결함 평가)

  • 임광희;나승우;심재기;양인영
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.121-124
    • /
    • 2003
  • This paper shows shear wave behavior of CFRP(carton fiber reinforced plastics) composite laminates as a polar grid form to evaluate vibration pattern of ultrasonic transducers, which gives measured modelling fundamental contents of nondestructive evaluation. This modelling decomposes the transmission of a linearly polarized wave into orthogonal components through each ply of a laminate. It is found that a high probability shows between the model and measurement system in characterizing lay up of CFRP composite laminates. Also evaluating quantitatively the defects in CFRP laminates who found to be possible of normalized frequency obtained from 2D-FFT technique based on C-scan method. Thus, the technique is proven to be one of the useful means to evaluate any internal defect in CFRP composite laminates.

  • PDF