• 제목/요약/키워드: Composite Sensor

검색결과 535건 처리시간 0.026초

섬유방향 변화에 따른 직물구조 CFRP 적층판의 균열진전 및 AE평가 (Crack Propagation and Acoustic Emission Evaluation of Plain Woven CFRP Laminate Composites for Fiber Orientation)

  • 윤유성;권오헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.364-369
    • /
    • 2003
  • Crack propagation and AE characteristics of CFRP plain woven laminate composites are examined with acoustic sensor by AEDSP 32/16 board in PC system. AE signals are measured during the fracture behavior tests. The purpose of study is the estimation of the crack extension behavior effected between three kinds of fiber orientation for plain woven CFRP laminate composite and the relationship between AE characteristics and load-displacement curves and crack extension length.

  • PDF

"Dice와 fill" 방식을 이용한 1-3 압전복합재의 제조와 횡방향 단위 크기에 따른 압전특성 평가 (Fabrication of 1-3 Piezo-composites with a "Dice & Fill" Method and Characterization of Their Piezoelectric Properties as a Function of Lateral Spatial Scale)

  • 김영덕;김광일;정우철;김흥락;김동수
    • 비파괴검사학회지
    • /
    • 제22권4호
    • /
    • pp.354-360
    • /
    • 2002
  • NDT나 의료용 영장장치에 응용되는 압전복합재는 일반적인 세라믹이나 고분자 압전재료에 비하여 많은 장점을 가진다. 이들 응용분야에서는 전기기계결합계수가 높아야 하고 음향임피던스가 낮아야 한다. 그러나, 압전복합재의 횡방향 단위 크기가 조밀하지 못할 경우 횡방향으로 진행하는 판파에 의한 불필요한 진통이 표면에 발생하게 된다. 횡방향 단위 크기와 세라믹 체적비에 따른 압전 특성을 조사하기 위하여 PMN-PZT 세라믹과 Epofix 에폭시로 에폭시의 폭의 달리하면서 1-3형 압전복합채를 제작하였다. 제작된 1-3형 압전복합재의 두께방향 진동모드의 전기기계결합계 수, 음향임피던스는 각각 $0.36{\sim}0.64,\;9.8{\sim}22.7MRayl$ MRayl로 나타났으며, 횡방향 단위크기가 줄어들수록 횡방향 모드 공진 주파수가 증가하였다.

Free-standing Three Dimensional Graphene Incorporated with Gold Nanoparticles as Novel Binder-free Electrochemical Sensor for Enhanced Glucose Detection

  • Bui, Quoc Bao;Nguyen, Dang Mao;Nguyen, Thi Mai Loan;Lee, Ku Kwac;Kim, Hong Gun;Ko, Sang Cheol;Jeong, Hun
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권3호
    • /
    • pp.229-237
    • /
    • 2018
  • The electrochemical sensing performance of metal-graphene hybrid based sensor may be significantly decreased due to the dissolution and aggregation of metal catalyst during operation. For the first time, we developed a novel large-area high quality three dimensional graphene foam-incorporated gold nanoparticles (3D-GF@Au) via chemical vapor deposition method and employed as free-standing electrocatalysis for non-enzymatic electrochemical glucose detection. 3D-GF@Au based sensor is capable to detect glucose with a wide linear detection range of $2.5{\mu}M$ to 11.6 mM, remarkable low detection limit of $1{\mu}M$, high selectivity, and good stability. This was resulted from enhanced electrochemical active sites and charge transfer possibility due to the stable and uniform distribution of Au NPs along with the enhanced interactions between Au and GF. The obtained results indicated that 3D-GF@Au hybrid can be expected as a high quality candidate for non-enzymatic glucose sensor application.

고분자 압전센서 신호를 이용한 스마트 복합적층판의 충격 손상 규명 (Identification of Impact Damage in Smart Composite Laminates Using PVDF Sensor Signals)

  • 이홍영;김인걸;박찬익
    • 한국항공우주학회지
    • /
    • 제32권7호
    • /
    • pp.51-59
    • /
    • 2004
  • 저속충격에 의한 복합재의 파손 모드를 규명하기 위하여 PVDF 센서를 이용한 신호취득 방법과 측정된 PVDF 센서 신호를 시간-주파수 분석법 (time-frequency analysis)인 국소 퓨 리에 변환 및 웨이블렛 변환을 적용하여 분석할 수 있는 실험적 전차에 대하여 고찰하였다. 고분자 암전센서를 이용하여 저속충격시 발생할 수 있는 여러 충격손상 형태 모재균열, 층간분리, 섬유파단에 의한 응력파 측정 가능성을 고찰하기 위하여 일련의 저속충격 시험을 수행하였다. 충격 시험 후, 저속 충격을 받은 적층판에 대하여 C-scan 과 단면 검사를 통하여 센서 신호, 손상 모드 및 크기에 대한 상관관계를 고찰하였다. 센서신호의 취득과 신호분석을 통하여 저속충격의 발생/진행과정을 알 수 있는 많은 중요한 정보가 PVDF 센서신호에도 내재되어 있음을 알 수 있으며 PVDF 센서 신호를 주의 깊게 분석함으로써 저속 충격에 의한 복합재료의 손상 모드 규명이 가능하며 저속충격 위협에 대한 복합재 구조물의 건전성 모니터링에 활용할 수 있는 가능성을 제시하였다.

Electroanalytical Applications Based on Carbon Nanotube/Prussian Blue Screen-printable Composite

  • Shim, Jun-Ho;Lee, Jae-Seon;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권6호
    • /
    • pp.1583-1588
    • /
    • 2010
  • A single step fabrication process of carbon nanotube/Prussian Blue (CNT/PB) paste electrodes based on screen printing technology has been studied as an amperometric sensor for the determination of hydrogen peroxide and free chlorine. Compared to the classical carbon paste (CP) electrode, the CNT paste electrode greatly enhanced the response in the presence of hydrogen peroxide due to the electrocatalytic activity of the CNT. Based on the CNT/binder paste, PB was also incorporated into a network of CNT paste and characterized. The best electroanalytical properties of PB-mixed sensors to hydrogen peroxide were obtained with PB ratio of 10 wt % composition, which showed fast response time ($t_{90}{\leq}5$ s; 0.2 - 0.3 mM), low detection limit of 1.0 ${\mu}M$, good linear response in the range from $5.0{\times}10^{-5}$ - $1.0{\times}10^{-3}$ mol $L^{-1}$ ($r^2$ = 0.9998), and high sensitivity of -8.21 ${\mu}AmM^{-1}$. In order to confirm the enhanced electrochemical properties of CNT/PB electrode, the sensor was further applied for the determination of chlorine in water, which exhibited a linear response behavior in the range of 50 - 2000 ppb for chlorine with a slope of 1.10 ${\mu}Appm^{-1}$ ($r^2$ = 9971).

Imprinted Graphene-Starch Nanocomposite Matrix-Anchored EQCM Platform for Highly Selective Sensing of Epinephrine

  • Srivastava, Juhi;Kushwaha, Archana;Singh, Meenakshi
    • Nano
    • /
    • 제13권11호
    • /
    • pp.1850131.1-1850131.19
    • /
    • 2018
  • In this paper, an electrochemical sensor for epinephrine (EP), a neurotransmitter was developed by anchoring molecularly imprinted polymeric matrix (MIP) on the surface of gold-coated quartz crystal electrode of electrochemical quartz crystal microbalance (EQCM) using starch nanoparticles (Starch NP) - reduced graphene oxide (RGO) nanocomposite as polymeric format for the first time. Use of EP in therapeutic treatment requires proper dose and route of administration. Proper follow-up of neurological disorders and timely diagnosis of them has been found to depend on EP level. The MIP sensor was developed by electrodeposition of starch NP-RGO composite on EQCM electrode in presence of template EP. As the imprinted sites are located on the surface, high specific surface area enables good accessibility and high binding affinity to template molecule. Differential pulse voltammetry (DPV) and piezoelectrogravimmetry were used for monitoring binding/release, rebinding of template to imprinted cavities. MIP-coated EQCM electrode were characterized by contact angle measurements, AFM images, piezoelectric responses including viscoelasticity of imprinted films, and other voltammetric measurements including direct (DPV) and indirect (using a redox probe) measurements. Selectivity was assessed by imprinting factor (IF) as high as 3.26 (DPV) and 3.88 (EQCM). Sensor was rigorously checked for selectivity in presence of other structurally close analogues, real matrix (blood plasma), reproducibility, repeatability, etc. Under optimized conditions, the EQCM-MIP sensor showed linear dynamic ranges ($1-10{\mu}M$). The limit of detection 40 ppb (DPV) and 290 ppb (EQCM) was achieved without any cross reactivity and matrix effect indicating high sensitivity and selectivity for EP. Hence, an eco-friendly MIP-sensor with high sensitivity and good selectivity was fabricated which could be applied in "real" matrices in a facile manner.

복합재 패널에서 유도 탄성파를 이용한 이미지 기반 손상탐지 기법 개발 Part I. 손상위치 탐지 알고리즘 (Image Based Damage Detection Method for Composite Panel With Guided Elastic Wave Technique Part I. Damage Localization Algorithm)

  • 김창식;전용운;박정선;조진연
    • 한국항공우주학회지
    • /
    • 제49권1호
    • /
    • pp.1-12
    • /
    • 2021
  • 본 논문은 복합재 패널에서 압전 작동기를 사용하여 탄성파를 생성하고, 손상에서의 반사된 신호를 압전 감지기에서 탐지하여 손상위치를 추정할 수 있는 알고리즘을 개발하였다. 손상이 없는 신호와 손상이 있는 신호를 비교하여 손상신호를 추정하는 진단적 접근방법을 사용하였다. 신호 상관관계를 이용하여 탄성파의 군속도를 계산하고 압전기 위치정보를 이용하여 손상정보를 추출하였다. 하지만 탄성파의 비선형 특성으로 인해, 손상정보는 다양한 신호의 조합으로 구성되기 때문에, 손상위치를 명확히 구별하기 어렵다. 이에 본 논문에서는 손상에서 반사된 신호정보를 신호 도달거리의 면적으로 변환해서 손상의 중심위치를 찾는 누적함수 특성벡터 알고리즘(CSFV, cumulative summation feature vector)을 새롭게 제안하고, 특성벡터를 손상지수와의 곱으로 표현하는 가시화 기법을 적용하였다. 또한 복합재 패널에서 실험검증을 수행하고, 기존의 알고리즘과의 비교를 통해 제안된 알고리즘이 정확도 높게 손상위치를 검출할 수 있음을 보였다.

MODIS 식생지수에 미치는 센서 geometry의 영향과 센서 간 자료 호환성 검토 (Compatibility of MODIS Vegetation Indices and Their Sensitivity to Sensor Geometry)

  • 박선엽
    • 대한지리학회지
    • /
    • 제49권1호
    • /
    • pp.45-56
    • /
    • 2014
  • 지표의 식생활력도를 간접적으로 반영하는 위성 기반의 식생지수 자료를 연속적으로 확보하기 위해 자료합성법이 통상적으로 적용된다. 이는 자료합성을 통해 누락 자료나 신호 오류의 영향을 최소화함으로써 장기적인 식생지수 자료 구축이 가능해지기 때문이다. 또, 합성주기에 따라 두 개 이상의 위성 센서로부터 같은 시점에 생성된 식생지수 자료를 상호교호적으로 사용할 경우, 식생지수 자료 축적의 연속성과 안정성을 보다 더 강화할 수 있다. 본 연구는 식물생장 연구에 있어 위성시스템 간 자료 호환 가능성뿐만 아니라 MODIS 자료 취득 조건, 즉 태양과 센서의 천정각이 미치는 영향을 센서 geometry 측면에서 파악하여 장기적인 식생모니터링을 위한 자료 구축 개선에 기여하고자 한다. 연구 기간 중 센서천정각의 변화는 일정한 패턴을 보이지 않았고, 연도별로 불규칙한 등락을 나타냈다. 또, 동일 계절별로 분석한 결과에서도 계절에 따른 특징적 경년변화 패턴은 나타나지 않았다. 두 가지 분석 대상 자료인 NDVI와 EVI를 비교했을 때, EVI가 NDVI에 비해 더 안정된 결과를 보여주었고, 전반적으로 중위도 지역 식물생장의 계절적 특성을 전형적으로 보여주었다. 식생피복에 따른 NDVI-EVI 간 상관관계는 모두 유효한 결과를 얻었으나, 식생피복별로 상관도 차이를 보였고 상호간에 선형 관계가 아닌 상단부에서 수렴되는 곡선 관계를 보여주었다. Terra와 Aqua 위성에 의해 오전과 오후에 각각 관측된 식생지수를 비교한 결과, 상관계수 범위는 NDVI의 경우 0.641-0.880로, EVI의 경우 0.747-0.963으로 나타나, NDVI자료에 비해 EVI자료의 호환성이 높은 것으로 조사되었다. 두 센서 기반의 식생지수간 호환성 개선을 위해서는 두 자료 간의 회귀선으로부터 벗어나 있는 예외치에 대한 정밀한 분석이 과제로 남는다.

  • PDF

압전복합센서용 PZT 세라믹스의 미세구조 및 압전특성에 미치는 $Cr_2O_3$$Nb_2O_5$ 첨가효과 (Effect of $Cr_2O_3$ and $Nb_2O_5$ Additives on the Microstructure and Piezoelectric Properties of PZT Ceramics for Piezoelectric Composite Sensor)

  • 백종후;엄형근;임은경;김창일;이미재;최병현;김세기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.27-28
    • /
    • 2005
  • 본 연구에서는$Cr_2O_3$$Nb_2O_5$ 를 첨가한 $Pb(Zr_{0.54}Ti_{0.48})O_3$ 세라믹스에서 $Nb_2O_5$ 첨가량에 따른 소결 및 압전, 유전특성을 조사하였다. $Pb(Zr_{0.54}Ti_{0.48})O_3$ + 0.2 wt% $Cr_2O_3$ + wt% $Nb_2O_5$ ($0.{\sim}2wt.%$)의 첨가량에 따른 압전, 유전특성 및 미세구조에 관해 연구하였다. 본조성에서 $Nb_2O_5$ 첨가량이 증가함에 따라 입경의 크기는 증가하였으며, 0.5 wt% $Nb_2O_5$ 첨가조성에서 $4\sim5\mu m$의 최대 평균입경을 보이다가 그 이상의 첨가 조성에서 급격히 감소하였다. 유전상수와 kp 는 $Nb_2O_5$ 첨가량이 1.0 wt% 조성까지 증가하였다가 그 이상 조성에서 감소하였다. $Nb_2O_5$ 첨가량이 증가함에 따라 삼방정(rhombohedral)구조에서 정방정(tetragonal)구조로 상전이 일어났으며, 본 조성의 상경계 영역인 0.5 wt% 조성에서 $\varepsilon_r$ = 730, $k_p$ = 0.72, $d_{33}$ = 450, $g_{33}$ = 70의 우수한 압전 특성을 나타내었다. 이러한 조성은 접촉센서용 복합압전소재의 실용가능성을 제시하였다.

  • PDF

정상 웨이블릿 변환을 이용한 항공기 FBG 센서의 변형률 탐지 정확도 향상 (Improvement of Strain Detection Accuracy of Aircraft FBG Sensors Using Stationary Wavelet Transform)

  • 손영준;신현성;홍교영
    • 한국항행학회논문지
    • /
    • 제23권4호
    • /
    • pp.273-280
    • /
    • 2019
  • 구조 건전성 모니터링 기술을 이용하여 항공기의 유지 보수 비용을 줄이고 항공기의 가동률을 높이고자 하는 많은 연구가 진행되고 있다. 이에 FBG 센서에 대한 많은 연구가 함께 진행되고 있다. 하지만 복합재 내부에 FBG 센서를 설치할 경우, 복합재 층 사이에 보이드(void)가 발생하게 되고 이로 인해 신호 갈라짐 (split problem)이 발생하게 된다. 또한, FBG 센서는 전자기파에 영향을 받지 않지만, 후속처리 과정에서 사용되는 전자장비에 의한 전자기파 잡음이 발생하게 된다. 본 논문에서는 이러한 잡음으로 인한 오차를 줄이기 위해 이동 불변의 특성을 지니고 비선형적인 신호분석에 효율적인 정상 웨이블릿 변환 기법을 제시하였다. 그리고 위의 상황에서 웨이블릿 패킷 변환과 비교하였을 경우 정상 웨이블릿 변환의 잡음 제거 성능이 더 우수한 것을 확인하였다.