• Title/Summary/Keyword: Component removal

Search Result 356, Processing Time 0.025 seconds

Video Haze Removal Method in HLS Color Space (HLS 색상 공간에서 동영상의 안개제거 기법)

  • An, Jae Won;Ko, Yun-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.1
    • /
    • pp.32-42
    • /
    • 2017
  • This paper proposes a new haze removal method for moving image sequence. Since the conventional dark channel prior haze removal method adjusts each color component separately in RGB color space, there can be severe color distortion in the haze removed output image. In order to resolve this problem, this paper proposes a new haze removal scheme that adjusts luminance and saturation components in HLS color space while retaining hue component. Also the conventional dark channel prior haze removal method is developed to obtain best haze removal performance for a single image. Therefore, if it is applied to a moving image sequence, the estimated parameter values change rapidly and the haze removed output image sequence shows unnatural glitter defects. To overcome this problem, a new parameter estimation method using Kalman filter is proposed for moving image sequence. Experimental results demonstrate that the haze removal performance of the proposed method is better than that of the conventional dark channel prior method.

Removal Efficiency of Pollutants in Agricultural Wastewater by Constructed Wetlands on Reclaimed Land in the Goheung Bay (고흥만 간척지 내 인공습지에 의한 농경배수 정화효율에 관한 연구)

  • Yu, Hun-Sun;Kang, Dong-Hwan;Kwon, Byung-Hyuk
    • Journal of Wetlands Research
    • /
    • v.11 no.3
    • /
    • pp.37-47
    • /
    • 2009
  • This research was conducted at the constructed wetland in Goheung reclaimed land, and water quality components were measured at the 12 points in 15 March 2008 and 10 January 2009, respectively. Temperature, pH, DO, EC and salinity components were measured at the field, and TOC, Cl-, COD, TSS, T-P and TN components were analyzed laboratory. Concentrations of field measured components at inflow points were higher than in constructed wetland. TOC concentration ratio of inflow water to constructed wetland water was higher in January, and Cl concentration ratio of it was higher in March. And, COD concentration ratio of it were 1.37 for March and 1.49 for January, respectively. T-P and T-N concentration ratios of it at inflow points were higher 3 times than in constructed wetland. Constructed wetland attenuated concentration of contaminated components inflow to it. Removal efficiencies of Cl-, T-P and T-N components in inflow water were high at the constructed wetland. removal efficiencies of Cl component were 83% for 1st monitoring and 76% for 2nd monitoring, this removal efficiency be caused by dilution effect of constructed wetland. removal efficiencies of T-P component were 67% for 1st monitoring and 69% for 2nd monitoring, and they of T-N component were 100% for 1st monitoring and 95% for 2nd monitoring. Abnormal removal efficiency of T-N component is caused that nitrogen in inflow water was a little. Removal efficiency of T-P component was higher in January, and T-N component was higher in March. This is caused by environmental difference between growing season and winter.

  • PDF

Prediction of Dimensional Instability Resulting from Layer Removal of an Internally Stressed Orthotropic Composite Cylinder

  • Shin, Shang-Hyon
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.757-761
    • /
    • 2002
  • When a layer of cylindrical composite component containing an axisymmetric residual stress state is removed from the inner or outer surface, the dimension of the remaining material changes to balance internal forces. Therefore, in order to machine cylindrical composite components within tolerances, it is important to know dimensional changes caused by residual stress redistribution in the body. In this study, analytical solutions for dimensional changes and the redistribution of residual stresses due to the layer removal from a residually stressed cylindrically orthotropic cylinder were developed. The cylinder was assumed to have axisymmetric radial, tangential and axial residual stresses. The result of this study is useful in cases where the initial residual stress distribution in the component has been measured by a non-destructive technique such as neutron diffraction with no information on the effect of layer removal operation on the dimensional changes.

Statistical Analysis of Sewage Plant Operation (하수처리장 운전조건의 통계분석)

  • 이찬형;문경숙
    • Journal of Environmental Science International
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2002
  • In this study, we examined statistical analysis between sewage plant operations parameters and effluent quality We got six components from principle component analysis of the operation parameters and secondary effluent quality. 91.8% of the total variance was explained by the six components. The components were identified in the following order : 1) organic matter removal by aeration basin microbe, 2) settleability on secondary clarifier load, 3) removal of nutrients, 4) microbial number increasement and species diversity, 5) microbial activity in aeration basin, 6) oxidation in aeration basin.

A GNSS Signal Correlation Using Map-based Partial-time Common Intermediate Frequency Removal Method (맵 기반의 부분시간 공통 중간주파수 제거방식을 이용한 GNSS 신호의 상관 기법)

  • Im, Sung-Hyuck;Jee, Gyu-In
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.7
    • /
    • pp.695-701
    • /
    • 2008
  • In this paper, we propose the efficient Doppler removal method using map-based partial-time common intermediate frequency removal technique. In the proposed algorithm, the 2-stage carrier removal process was used. First, the component of common intermediate frequency is removed. Next the component of Doppler was removed with averaging and approximation. For the evaluation of the proposed algorithm, The real-time software GPS L1 C/A-code receiver was implemented. When the proposed algorithms are used, 12 tracking channels with 3 track arm(early, prompt, late) is operated real-time on PC using a Intel Pentium-III 1.0GHz CPU. Also, the requirement of memory was less than 2Mbytes. The real-time software GNSS receiver using the proposed algorithms provides the navigation solution with below 10 meter rms error. Especially, in spited of using the various approximations for implementing the algorithms, the high sensitivity capability (able to track the weak signal with -159dBm) was achieved.

A Study on the Development of Fouling Analysis Technique for Shell-and-Tube Heat Exchangers (다관원통형 열교환기의 파울링 해석기법 개발 연구)

  • Hwang, Kyeong-Mo;Jin, Tae-Eun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.167-173
    • /
    • 2004
  • Fouling of heat exchangers is generated by water-borne deposits, commonly known as foulants including particulate matter from the air, migrated corrosion produces; silt, clays, and sand suspended in water; organic contaminants; and boron based deposits in plants. The fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. This paper describes the fouling analysis technique developed in this study which can analyze the thermal performance for heat exchangers and estimate the future fouling variations. To develop the fouling analysis technique fur heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. For the purpose or verifying the fouling analysis technique, the routing analyses were performed for four heat exchangers in several nuclear power plants; two residual heat removal heat exchangers of the residual heat removal system and two component cooling water heat exchangers of the component cooling water system.

Cutting Force Analysis Under Chatter Condition with a Worn Tool (채터상황에서 마모된 공구가 받는 절삭력 해석)

  • 권원태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.292-301
    • /
    • 1994
  • The resultant cutting force during machining with a worn tool is viewed as a decomposition of the cutting force into a cutting force component related to chip removal from the workpiece and into a component dependent on the contact force between the tool flank's wear land and the workpiece. The shear line method, in which the cutting force is considered proportional to the length of the shear line, is used to calculate the cutting force component for the removal of the chip, while the elastic effect of the workmaterial on the tool is taken into consideration to analyze the effect of tool flank wear. The predicted resultant cutting force, expressed as the sum of both components, is compared to experimental data obtained during wave-on-wave cutting.

A Study on Heavy Metal Removal Characteristics Using Bone Char (골탄(bone char)의 중금속 제거 특성에 관한 연구)

  • Kim, Jae-Young;Kim, Hwan-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.253-258
    • /
    • 2007
  • The adsorption capacity of bone char for lead, cadmium and zinc was studied in both single and binary multiple component systems. Equilibrium experimental studies have been performed to determine the sorption capacity of bone char for each metal ion. These have been analysed using single and multi-component equilibrum models. The results show that the sorption of metal ions for multi-component systems can be predicted reasonably well from the IAS theory with the Langmuir equation, the Freundlich and the Slip equation for metal ions.

The Toxic Effect Of Marine V. Vulnificus Endotoxin OH the Blood Component in Rat (해양 V. vulnificus의 내독소가 rat의 혈액 성분에 미치는 독성 효과)

  • 이봉헌
    • Journal of Environmental Science International
    • /
    • v.6 no.1
    • /
    • pp.69-73
    • /
    • 1997
  • Endotoxin from the cell wall of marine V. vujnificus was .extracted using the hot phenol-water method, injected endotoxin into rat, and tested the toxic effect of endotoxin on the blood component In rat blood. The results showed that blood glucose, blood urea nitrogen, white blood cell, and reticulocyte were Increased and red blood cell was the same as the number of control group(normal blood), but platelet was decreased. Above results suggested that endotoxin induced a malfunction of liver and that the Increase of white blood cell was for the removal of foreign toxic substance.

  • PDF

Removal Rates of VOCs(Volatile Organic Compounds) for Treatment Condition using DAF(Dissolved Air Flotation) in Water Treatment (DAF(Dissolved Air Flotation)를 이용한 정수처리에서 처리조건에 따른 VOCs(Volatile Organic Compounds)의 처리효율에 대한 연구)

  • Kim, Mi-Jeong;Jun, Se-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.91-100
    • /
    • 1999
  • Treatment conditions of DAF(Dissolved Air Flotation) and removal rates of VOCs(Volatile Organic Compounds) in mixed water of H raw water and VOCs were investigated. The used VOCs were benzene, toluene, ethylbenzene, and xylene in aromatic compounds and iso propyl mereaptan, n-butyl mereaptan, dimethyl disulfide, and iso butyl mercaptan in odors. The related parameters include water type, treatment method, clay concentration, pH condition, flocculation time, flotation time, per-cent recycle, water temperature, pressure. The removal rates of VOCs were different on treatment process and water condition. Treatment time was longer, removal rates of VOCs was higher. Water temperature was more important than pressure in DAF parameters. Molecular weight was related with removal rate in several kinds of VOCs were decraesed by competition of each component in II raw water. When algac blooming D water was treated by DAF, TCOD(Total chemical Oxygen Demand) and chorophyll a was removed over 96%.

  • PDF