• Title/Summary/Keyword: Component of medium

Search Result 493, Processing Time 0.024 seconds

Production of Giant Hyssop Oil by Plant Tissue Culture (식물조직배양에 의한 배초향유의 생산)

  • Shin, Soon-Hee;Kim, Hae-Kyung;Chi, Hyung-Joon
    • Korean Journal of Pharmacognosy
    • /
    • v.22 no.2
    • /
    • pp.91-94
    • /
    • 1991
  • Callus was derived from the seedlings of Agastache rugosa(Labiatae). The growth rate of callus and the production of essential oil were studied with the variation of culturing conditions. 2, 4-D 2ppm in the medium was more effective for the production of essential oil than NAA 2ppm. The growth rate of callus and the production of essential oil were inhibited by the illumination of the light. The essential oils from Agastache rugosa and the callus cultivated on the medium containing 2, 4-D 2 ppm and kinetin 0.2 ppm were analysed by TLC, gas chromatography and mass spectrometry. These two oils showed different compositions. The main component of the plant oil, methyl chavicol was not contained in the callus oil.

  • PDF

Effect of Carbon Source and Carbon to Nitrogen Ratio on Carotenogenesis of Rhodotorula glutinis

  • Nam, Hee-Sop
    • Journal of Microbiology and Biotechnology
    • /
    • v.1 no.1
    • /
    • pp.75-78
    • /
    • 1991
  • The carotenoid biosynthesis of a red oleaginous yeast, Rhodotorula glutinis was significantly changed when the yeast was grown on different carbon substrates. The highest carotenoid production was obtained on culture medium containing glucose when the carbon to nitrogen ratio (C/N ratio) was adjusted to 25.7. Galactose stimulated the biosynthetic rate of torularhodin, a xanthophyll component of the yeast. With decreasing C/N ratio of the medium, significant changes of $\gamma$-carotene and torularhodin were observed such that increase in the torularhodin concentration was nearly equal to the decrease in $\gamma$-carotene. It was speculated that the nature of carbon substrate affected the metabolic rate of the cell, and accompanied by the different pattern of carotenoid accumulation in the cell.

  • PDF

Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance

  • Han, Daesu;Park, Yonggyun;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.246-247
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions, and torque pulsation. The control algorithm having zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive power. Combination of these two control algorithms depending on the operating requirements and depth of grid unbalance presents most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system. The proposed control algorithms are verified through transient response in the simulation.

  • PDF

Performance Analysis, Real Time Simulation and Control of Medium-Scale Commercial Aircraft Turbofan Engine

  • Kong, Chang-Duk;Jayoung Ki;Chung, Suk-Chou
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.776-787
    • /
    • 2001
  • The turbofan engine performance analysis for a medium scale commercial aircraft was carried out and the LQR control scheme for performance optimization was studied. By using scaled component maps from well-known CF6 engine characteristics, the steady-state performance analysis result was compared with BR715-56 engine performance data. The transient performance analysis was performed with four fuel schedules. The linear simulation was done at the maximum take-off condition. The real time linear simulation was performed by interpolation of the system matrices, which used the least square method as the function of LPC rotational speed. By using linear system matrices of design point, the LQR controller which used control variables for the fuel flow and the LPC bleed air was designed.

  • PDF

Examination of Root Induction Ratio for Regeneration of Alfalfa by Medium Component (알팔파 재분화에서 배지조성에 따른 뿌리 유도율 조사)

  • 김기용;강경민;박근제;배은경;이인애;이병현;곽상수;조진기
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.23 no.2
    • /
    • pp.95-100
    • /
    • 2003
  • The alfalfa (Medicago sativa L.) callus was induced from seeds on SH medium contained $3\;mg/{\ell}$ of 2,4-D. Several regenerated alfalfa plants and many shoots were obtained by procedure of Kim et al. (1999); 1) incubation for 28~30 days on SH medium added $5\;mg/{\ell}$ of NAA and $2\;mg/{\ell}$ of Kinetin, 2) incubation for 3~5 days on SH medium added $11\;mg/{\ell}$ of 2,4-D and $1\;mg/{\ell}$ of kinetin. 3) incubation for 21~25 days on SH medium added $1.6\;g/{\ell}$ of ammonium sulfate and $5.75\;g/{\ell}$ of proline. To increase of root induction ratio on plant regeneration process of alfalfa, root induction ratio was examined on 8 kinds of medium, containing different amount of hormone and SH salt. Root induction ratio was higher on SH medium contained IBA than SH basal medium. In case 1.5 mg of IBA was added in SH medium, root induction ratio was the highest to 56.0% in this study. On the other hand, root induction ratio was higher on SH medium diminished SH salt amount to half volume and addition of IBA makes high root induction ratio, too. Thus, we conclude that the medium for root induction of alfalfa may be added $1.5\;mg/{\ell}$ of IBA and diminished SH salt amount to half volume.

A Comparison of Control Algorithms for a Doubly Fed Induction Generator in Medium-voltage Wind Power System under Unbalanced Conditions

  • Go, Yu-Ran;Park, Hyeon-Cheol;Zhu, Yaqiong;Suh, Yong-Sug
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.194-195
    • /
    • 2010
  • This paper investigates control algorithms for a doubly fed induction generator (DFIG) with back-to-back converter in medium-voltage wind power system under unbalanced grid conditions. Operation of DFIG under unbalanced grid conditions causes several problems such as overcurrent, unbalanced currents, active power pulsation and torque pulsation. Three different control algorithms to compensate for the unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, efficiency, harmonic distortions and torque pulsation. The control algorithm having zero amplitude of negative sequence current shows the most cost-effective performance concerning fault ride-through capability and efficiency. The control algorithm for nullifying the oscillating component of the instantaneous active power generates least harmonic distortions. Combination of these two control algorithms depending on the operating requirements presents most optimized performance factors under the generalized unbalanced operating conditions.

  • PDF

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

Assessment of Water Quality using Multivariate Statistical Techniques: A Case Study of the Nakdong River Basin, Korea

  • Park, Seongmook;Kazama, Futaba;Lee, Shunhwa
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.197-203
    • /
    • 2014
  • This study estimated spatial and seasonal variation of water quality to understand characteristics of Nakdong river basin, Korea. All together 11 parameters (discharge, water temperature, dissolved oxygen, 5-day biochemical oxygen demand, chemical oxygen demand, pH, suspended solids, electrical conductivity, total nitrogen, total phosphorus, and total organic carbon) at 22 different sites for the period of 2003-2011 were analyzed using multivariate statistical techniques (cluster analysis, principal component analysis and factor analysis). Hierarchical cluster analysis grouped whole river basin into three zones, i.e., relatively less polluted (LP), medium polluted (MP) and highly polluted (HP) based on similarity of water quality characteristics. The results of factor analysis/principal component analysis explained up to 83.0%, 81.7% and 82.7% of total variance in water quality data of LP, MP, and HP zones, respectively. The rotated components of PCA obtained from factor analysis indicate that the parameters responsible for water quality variations were mainly related to discharge and total pollution loads (non-point pollution source) in LP, MP and HP areas; organic and nutrient pollution in LP and HP zones; and temperature, DO and TN in LP zone. This study demonstrates the usefulness of multivariate statistical techniques for analysis and interpretation of multi-parameter, multi-location and multi-year data sets.

A Medium Access Control Scheme for Reducing Energy Consumption through Avoiding Receipt of Redundant Messages in Wireless Sensor Networks (무선 센서 네트워크에서 중복 메세지 순신 회피를 통한 에너지 소비절감 매체 접근 제어)

  • Han, Jung-An;Lee, Moon-Ho
    • Journal of Information Technology Applications and Management
    • /
    • v.12 no.4
    • /
    • pp.13-24
    • /
    • 2005
  • The sensor network is a key component of the ubiquitous computing system which is expected to be widely utilized in logistics control, environment/disaster control, medical/health-care services, digital home and other applications. Nodes in the sensor network are small-sized and exposed to adverse environments. They are demanded to perform their missions with very limited power supply only. Also the sensor network is composed of much more nodes than the wireless ad hoc networks are. In case that some nodes consume up their power capacity, the network topology should change, and rerouting/retransmission is necessitated. Communication protocols studied for conventional wireless networks or ad hoc networks are not suited for the sensor network resultantly. Schemes should be devised to control the efficient usage of node power in the sensor network. This paper proposes a medium access protocol to enhance the efficiency of energy consumption in the sensor network node. Its performance is analyzed by simulation.

  • PDF

Control Strategy Compensating for Unbalanced Grid Voltage Through Negative Sequence Current Injection in PMSG Wind Turbines

  • Kang, Jayoon;Park, Yonggyun;Suh, Yongsug;Jung, Byoungchang;Oh, Juhwan;Kim, Jeongjoong;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.244-245
    • /
    • 2013
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF