• Title/Summary/Keyword: Compliance Method

Search Result 893, Processing Time 0.025 seconds

A study on Factors Influencing COVID-19 on depression and anxiety in university students (코로나-19가 대학생의 우울과 불안에 미치는 영향 요인 연구)

  • Chun, Yeol-Eo;Hwang, Hye-Young;Lee, Ha-Neung
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.583-591
    • /
    • 2022
  • In this study, the depression and anxiety of university students in the COVID-19 situation were identified, and the effects on depression and anxiety were indicated. Subjects were chosen randomly, and for the method a step selection multiple regression analysis was used. As a result of checking the factors affecting the subjects' general characteristics, stress level, preventive rule compliance level, and daily vitality level on depression and anxiety, the factors that had significant influence on depression were CPDI(𝛽=.230, p=.000), and K-ANX(𝛽=.472, p=.000). Other factors such as CPDI(𝛽=.276, p=.000), EDAS(𝛽=-.127, p=.019) and K-DEP(𝛽=.482, p=.000) were analyzed to have significant effects on anxiety. Therefore, the results of this study are thought to be meaningful as basic data that can be used to establish educational and counseling activities that help university students adjust to society and academically in the COVID-19 situation.

Development of Real-time Mission Monitoring for the Korea Augmentation Satellite System

  • Daehee, Won;Koontack, Kim;Eunsung, Lee;Jungja, Kim;Youngjae, Song
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.1
    • /
    • pp.23-35
    • /
    • 2023
  • Korea Augmentation Satellite System (KASS) is a satellite-based augmentation system (SBAS) that provides approach procedure with vertical guidance-I (APV-I) level corrections and integrity information to Korea territory. KASS is used to monitor navigation performance in real-time, and this paper introduces the design, implementation, and verification process of mission monitoring (MIMO) in KASS. MIMO was developed in compliance with the Minimum Operational Performance Standards of the Radio Technical Commission for Aeronautics for Global Positioning System (GPS)/SBAS airborne equipment. In this study, the MIMO system was verified by comparing and analyzing the outputs of reference tools. Additionally, the definition and derivation method of accuracy, integrity, continuity, and availability subject to MIMO were examined. The internal and external interfaces and functions were then designed and implemented. The GPS data pre-processing was minimized during the implementation to evaluate the navigation performance experienced by general users. Subsequently, tests and verification methods were used to compare the obtained results based on reference tools. The test was performed using the KASS dataset, which included GPS and SBAS observations. The decoding performance of the developed MIMO was identical to that of the reference tools. Additionally, the navigation performance was verified by confirming the similarity in trends. As MIMO is a component of KASS used for real-time monitoring of the navigation performance of SBAS, the KASS operator can identify whether an abnormality exists in the navigation performance in real-time. Moreover, the preliminary identification of the abnormal point during the post-processing of data can improve operational efficiency.

A Study on the Preparation of Distribution Table for Quantitative Evaluation of Small-Scale Environmental Impact Assessment

  • Dong-Myung CHO;Ju-Yeon LEE;Woo-Taeg KWON
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.6 no.3
    • /
    • pp.13-18
    • /
    • 2023
  • Purpose: The small-scale environmental impact assessment has been in operation since its implementation in August 2000, and is a system that meets the purpose of sustainable development in consideration of the environment in areas requiring conservation. However, when preparing a small environmental impact assessment report, the contents of the reduction measures are too qualitative, or reports are prepared to simply list the compliance stipulated by individual laws, and the contents of consultations prepared by consultative agencies and review agencies are not much different. In addition, the direction of consultation on development projects for similar locations of the same project type is frequently changed by reflecting the subjective judgment of the consultative officer of the Ministry of Environment (Environment Agency). Therefore, this study attempted to improve the establishment of measures to reduce the existing simple listing of qualitative contents and the inconsistent presentation of review opinions by consultative agencies and review agencies. Research design, data and methodology: The research method extracted absolute evaluation items and relative evaluation items among small environmental impact assessment items, analyzed and presented detailed items, and prepared a distribution table for each section according to the details of the relative evaluation items, and presented them as a table. Results: This study was conducted to derive uniform results with objective indicators in the preparation and consultation process of a small-scale environmental impact assessment. Conclusions: Once a quantitative evaluation is established, the consultant can objectively determine and process the environmental impact.

Leak Before Break Evaluation of Surge Line by Considering CPE under Beyond Design Basis Earthquake (설계초과지진시 CPE를 고려한 밀림관 파단전누설 평가)

  • Seung Hyun Kim;Youn Jung Kim;Han-geol Lee;Sun Yeh Kang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2022
  • Nuclear Power Plants (NPP) should be designed to have sufficient safety margins and to ensure seismic safety against earthquake that may occur during the plant life time. After the 9.12 Gyeongju earthquake accident, the structural integrity of nuclear power plants due to the beyond design basis earthquake is one of key safety issues. Accordingly, it is necessary to conduct structural integrity evaluations for domestic NPPs under beyond design basis earthquake. In this study, the Level 3 LBB (Leak Before Break) evaluation was performed by considering the beyond design basis earthquake for the surge line of a OPR1000 plant of which design basis earthquake was set to be 0.2g. The beyond design basis earthquake corresponding to peak ground acceleration 0.4g at the maximum stress point of the surge line was considered. It was confirmed that the moment behaviors of the hot leg and pressurized surge nozzle were lower than the maximum allowable loading in moment-rotation curve. It was also confirmed that the LBB margin could be secured by comparing the LBB margin through the Level 2 method. It was judged that the margin was secured by reducing the load generated through the compliance of the pipe.

Role of Exercise after Subacromial Bursa Injection in Subacromial Subdeltoid Bursitis (견봉하 삼각근하낭염 환자에서 견봉하낭 스테로이드 주사 후 운동의 효과)

  • Kim, Sunwoong;Kim, Sang Jun
    • Clinical Pain
    • /
    • v.16 no.1
    • /
    • pp.20-25
    • /
    • 2017
  • Objective: To find that the patients who conducted home self-exercise in conjunction with intra-articular corticosteroid injection will have better improvement in subacromial subdeltoid (SASD) bursitis symptoms than those who received only an injection. Method: A prospective, nonrandomized, comparison study was conducted in outpatient rehabilitation clinic in a tertiary university hospital. Patients diagnosed with SASD bursitis with physical examination and ultrasound evaluation were included and received ultrasound guided injection (UGI). Patients were divided into two groups according to the compliance of self-exercise: UGI-exercise group and UGI only group. Visual analog scale (VAS) was checked before, at 3 weeks, 3 months, and 6 months after the UGI. A patient's global impression of change (PGIC) survey was made at 3 months after the UGI. Results: A total of 82 patients with SASD bursitis were included. At 3 weeks after the injection, the mean VAS for the UGI-exercise group was 2.6 ± 1.7 and for UGI only group was 1.9 ± 1.3 (p=0.030). At 3 months after the injection, the mean VAS for the UGI-exercise group was 4.0 ± 1.3 and for UGI only group was 5.4 ± 1.4 (p<0.001). Conclusion: We concluded that home-based self-exercise of the shoulder provides an additional benefit for pain alleviation possibly with prolonging the effect of injection in SASD bursitis.

Channel Modeling and RF Performance Verification in mmWave Bands Based on NS-3 (NS-3 기반의 mmWave 대역 채널 모델링 및 RF 성능 검증)

  • Seung-Min Lee;Jun-Seok Seo;Hong-Je Jang;Myung-Ryul Choi
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.650-656
    • /
    • 2023
  • This paper implements a channel model for mmWave bands using an NS-3-based 5G system-level simulator and analyzes the reliability and validity of the implemented model through RF performance verification. The channel model for RF performance verification in the mmWave bands consider parameters such as characteristics defined in 3GPP TR 38.901, beam-forming, antenna configuration, scenarios, among others. Furthermore, the simulation results verify compliance within the ranges permitted by the 3GPP standards and verify reliability in indoor environmental scenarios by exploiting the Radio Environment Map (REM). Therefore, the channel model implemented in this study is applicable to the actual design and establishment of 5G networks, presenting a method to evaluate and validate RF performance by adjusting various parameters.

Development of Guideline for Heuristic Based Usability Evaluation on SaMD (SaMD에 대한 휴리스틱 기반 사용적합성 평가 가이드라인 개발)

  • Jong Yeop Kim;Junghyun Kim;Zero Kim;Myung Jin Chung
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.428-442
    • /
    • 2023
  • In this study, we have a goal to develop usability evaluation guidelines for heuristic-based artificial intelligence-based Software as a Medical Device (SaMD) in the medical field. We conducted a gap analysis between medical hardware (H/W) and non-medical software (S/W) based on ten heuristic principles. Through severity assessments, we identified 69 evaluation domains and 112 evaluation criteria aligned with the ten heuristic principles. Subsequently, we categorized each evaluation domain into five types, including user safety, data integrity, regulatory compliance, patient therapeutic effectiveness, and user convenience. We proposed usability evaluation guidelines that apply the newly derived heuristic-based Software as a Medical Device (SaMD) evaluation factors to the risk management process. In the discussion, we also have proposed the potential applications of the research findings and directions for future research. We have emphasized the importance of the judicious application of AI technology in the medical field and the evaluation of usability evaluation and offered valuable guidelines for various stakeholders, including medical device manufacturers, healthcare professionals, and regulatory authorities.

A Study on Improving Shock Absorption Test of Safety Helmet (안전모의 충격 흡수성 시험 개선에 관한 연구)

  • Sang Woo Shim;Yong Su Sim;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.36-42
    • /
    • 2023
  • In this study, 50 ABE-type hard hats were procured from five certified commercial manufacturers, and shock absorption tests were conducted in accordance with Protective Equipment Safety Certification Notice No. 2020-35. The tests were performed under both high- and low-temperature conditions, adhering to safety helmet testing standards. The highest shock transmission ranges were recorded in the tests, with an average energy range of 2,600-4,108 N at high temperatures and 2,316-3,991 N at low temperatures. All five hard hat models demonstrated a maximum transmitted impact force below 4,450 N, without any loss of cap and attachment functionality, confirming their compliance with performance standards. Furthermore, we evaluated the side impact performance of the safety helmets of each company, with an average range of 4,722-5,267 N. Company A exhibited the lowest measurement at 4,722 N. Comparing these results with international safety standards and the national shock absorption test criteria, it was observed that the maximum transmitted shock value using government-specified impact weight falls within the range of 4,450-5,000 N. However, it was noted that developed countries have established specific standards for the side impact forces on safety helmets, which are legally mandated. Consequently, it is imperative for South Korea to enhance its safety helmet side impact performance test methodology to align with domestic standards in the future.

Hemodialysis Patients Experience in Food Craving (혈액투석 환자의 음식갈망 경험)

  • Jeong Hee Kang;Sinhye Kang
    • Journal of Industrial Convergence
    • /
    • v.22 no.2
    • /
    • pp.127-134
    • /
    • 2024
  • This study was attempted to understand the phenomenon in depth by exploring the food craving of hemodialysis patients experienced during hemodialysis. Participants selected seven adult patients diagnosed with end-stage renal failure and receiving hemodialysis treatment from medical institutions. he collected data were analyzed using a phenomenological analysis method. As a result of the analysis the food craving of hemodialysis patients was derived into two categories included craving experience in the cognitive domain craving experience in the emotional domain and five themes: 'Looking for foods that are water and watery as a result of thirst','Food thoughts come to mind all day as a result of a limited diet', 'Always hungry', 'Faced with appetizing situations every hour', 'experiencing negative emotions due to failure to control meals'. The results of this study which sheds light on food craving from the perspective of hemodialysis patients should improve the understanding of hemodialysis patients appetite control water restrictions and dietary compliance and allow them to understand the food craving attributes of hemodialysis patients and provide customized education optimized for that extent when applying dietary education and nursing interventions suitable for them.

Hazardous Material Process Risk Evaluation Using HAZOP and Bow-tie (HAZOP 및 BOW-TIE를 이용한 위험물질 취급공정의 위험성평가)

  • Min-Seo Nam;Byung-Tae Yoo
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.35-43
    • /
    • 2024
  • With continuous advancements in industry, science, and technology, there is a steady increase in the number and utilization of new chemicals. The growing societal emphasis on chemical safety management is paralleled by an increasing public demand for robust safety measures. While various ministries at the government level oversee the safety management of chemical substances, the occurrence of accidents related to chemical substances remains frequent each year due to problems such as aging facilities and careless handling. Upon analyzing domestic chemical accident cases, incidents occurred predominantly in the sequence of leakage, explosion, fire, and others. The main causes of these accidents were examined, revealing facility defects and non-compliance with safety management as the primary contributing factors. In this study, Hazard and Operability Analysis (HAZOP) was employed to identify hazardous risk factors associated with the handling of hydrofluoric acid in workplaces, and a risk assessment was performed using Bow-Tie method. Based on the results of this study, it is expected to enhance safety management plans aimed at preventing chemical accidents in workplaces dealing with similar facilities. Ultimately, these insights contribute to the development of an advanced chemical safety management system, capable of proactively preventing potential chemical accidents.