• 제목/요약/키워드: Compliance Chamber

검색결과 24건 처리시간 0.026초

바이오매스를 에너지원으로 하는 유기냉매 사이클 스크롤 팽창기 발전 장치 설계 (Design of Scroll Expander for Electric Power Generation System using Organic Rankine Cycle with Biomass Energy Source)

  • 문제현;유제승;김현진;조남진
    • 동력기계공학회지
    • /
    • 제16권4호
    • /
    • pp.30-36
    • /
    • 2012
  • A scroll expander has been designed to produce a shaft power from a R134a Rankine cycle for electricity generation. Heat was supplied to the Rankine cycle through a heat exchanger, which received heat from another cycle of water. In the water cycle, water was heated up in a boiler using biogenic solid fuel. The designed scroll expander was a horizontal type, and a trochoidal oil pump was employed for oil supply to bearings and Oldham-ring keys. For axial compliance, a back pressure chamber was created on the backside of the orbiting scroll base plate. Numerical study has been carried out to estimate the performance of the designed scroll expander. The expander was estimated to produce the shaft power of about 2.9 kW from a heat supply of 36 kW, when the temperature of R134a was $80^{\circ}C$ and $35^{\circ}C$ at the evaporator and condenser of the Rankine cycle, respectively. The expander efficiency was about 70.5%. When the amount of heat supply varied in the ranges of 7.5~55 kW, the expander efficiency changed in the range of 45.6~70.5%, showing a peak efficiency of 70.5% at the design shaft speed.

추력 30톤급 액체산소/케로신 로켓엔진 연소장치 개발(II)-가스발생기 (Development of 30-Tonf LOx/Kerosene Rocket Engine Combustion Devices(II) - Gas Generator)

  • 최환석;서성현;김영목;조광래
    • 한국항공우주학회지
    • /
    • 제37권10호
    • /
    • pp.1038-1047
    • /
    • 2009
  • 추력 30톤급 펌프공급방식 액체로켓엔진을 위한 가스발생기 개발 과정에 관하여 기술하였다. 액체산소와 케로신을 추진제로 연료 과농 조건에서 작동하는 가스발생기의 개발을 위해 분사기 개발에서부터 시작하여 축소형, 실물형 개발시제를 거쳐 가스발생기 단품 개발을 성공적으로 완료하였다. 가스발생기 설계 과정에서 다양한 해석적 방법을 적용하였으며 점화 시험, 연소성능 및 연소안정성 평가시험, 내구성 평가시험 등을 통해 가스발생기의 성능요구사항을 시험적으로 검증하였다. 개발된 가스발생기는 연소압 및 혼합비 운용 영역 내에서 안정적으로 작동하며 성능 및 수명 요구조건을 만족시킴을 확인하였다.

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.

국제표준은행관행(ISBP745)의 변경내용과 실무적용에 관한 연구 (A Study on the Revision of the ISBP745 and Practical Adaptation in the field)

  • 임재욱
    • 통상정보연구
    • /
    • 제16권5호
    • /
    • pp.87-114
    • /
    • 2014
  • ISBP는 2002년 화환신용장통일규칙(UCP 500) 하에서 ISBP645가 처음 발간된 이래, 2007년 화환신용장통일규칙이 UCP600으로 개정되자 이에 맞춰 ISBP681로 개정되었고, 다시 2013년 ISBP745가 발간된 것이다. 따라서 ISBP745는 ISBP의 세 번째 버전이자, 두 번째 개정이 되는 셈이다. ISBP의 두 번째 버전인 ISBP681은 UCP의 개정에 따른 것이나, ISBP745는 기존의 ISBP681이 시간 제약에 따라 개정보다는 업데이트 수준에 머물러 국제표준은행관행을 제대로 반영하지 못한다는 지적과 UCP600이 시행된 이후 상당한 기간이 경과되어 새로운 관행을 반영하여야 한다는 등의 개정필요성이 제기됨에 따라 UCP600하에서 다시 개정된 것이라 할 것이다. 신용장 거래에서 요구하는 서류는 매우 다양하며 ISBP745는 이와 같은 현실을 반영하여 ISBP681에서 규정한 원산지 증명서와 선적전검사증명서, 분석증명서, 검사증명서 이외에 추가적인 서류에 대하여 언급하고 이에 대한 판단근거를 제시하는 등의 추가적인 개정이 이루어졌다. 본 연구는 이러한 상황의 변화에 따라 ISBP745의 주요 개정 내용을 살펴보고, 특히 수익자증명서, 포장명세서, 중량증명서, 분석증명서, 훈증증명서 등 ISBP745에서 새롭게 추가된 서류의 심사기준과 실무적 적용에 관한 시사점을 얻고자 하였다. 또한 ISBP745에는 포함되지 않았으나 신용장 조건에서 빈번하게 요구되는 각종 증명서와 통지서 등에 대한 고찰을 통하여 신용장의 서류조건 일치에 대한 분석과 이에 따른 시사점을 도출하고자 하였다. 실무업계에서는 신용장의 문구를 세밀하게 살펴보고 신용장 조항에 나타난 다양한 선적서류들에 대한 지시사항과 ISBP 규정을 숙지하여 신용장 거래에 있어 서류불일치로 인하여 발생하는 시간과 비용의 문제들을 해결하여야 할 것이다.

  • PDF