• Title/Summary/Keyword: Complex power

Search Result 2,171, Processing Time 0.026 seconds

Bridge-edges Mining in Complex Power Optical Cable Network based on Minimum Connected Chain Attenuation Topological Potential

  • Jiang, Wanchang;Liu, Yanhui;Wang, Shengda;Guo, Jian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.3
    • /
    • pp.1030-1050
    • /
    • 2021
  • The edges with "bridge characteristic" play the role of connecting the communication between regions in power optical cable network. To solve the problem of mining edges with "bridge characteristic" in provincial power optical cable network, the complex power optical cable network model is constructed. Firstly, to measure the generated potential energy of all nodes in n-level neighborhood local structure for one edge, the n-level neighborhood local structure topological potential is designed. And the minimum connected chain attenuation is designed to measure the attenuation degree caused by substituted edges. On the basis of that, the minimum connected chain attenuation topological potential based measurement is designed. By using the designed measurement, a bridge-edges mining algorithm is proposed to mine edges with "bridge characteristic". The experiments are conducted on the physical topology of the power optical cable network in Jilin Province. Compared with that of other three typical methods, the network efficiency and connectivity of the proposed method are decreased by 3.58% and 28.79% on average respectively. And the proposed method can not only mine optical cable connection with typical "bridge characteristic" but also can mine optical cables without obvious characteristics of city or voltage, but it have "bridge characteristic" in the topology structure.

Complex Vector Modeling and Series Decoupling Current Control Strategy of High-Power L/LCL Type Grid-Connected Converter Under Low Switching Frequency

  • Wang, Yingjie;Jiao, Lanyi;Yang, Bo;Wang, Wenchao;Liu, Haiyuan
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1879-1888
    • /
    • 2018
  • With power level of grid-connected converters rising, the switching frequency of the switching devices is commonly greatly reduced to improve its power capacity. However, this results in serious couplings of the dq current components, which leads to degradation of the static and dynamic performances of grid-connected converters and fluctuations of the reactive power in dynamic processes. In this paper, complex vector models under low switching frequency are established for an L/LCL grid-connected converter, and the relationship between the switching frequency and the coupling degree is analyzed. In addition, a series decoupling current control strategy is put forward. It is shown that the proposed control strategy can eliminate the couplings, improve the performances and have good robustness to parameter variations through static and dynamic characteristics analyses and a sensitivity analysis. Experimental and simulation results also verify the correctness of the theoretical analyses and the superiority of the proposed control strategy.

Power demands and effencient power supply method in kaesung industrial complex (개성공단 전력수요 전망과 효율적 공급방안에 관한 연구)

  • Lee, Hong-Gi;Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.73-78
    • /
    • 2008
  • This paper predicts the future power demands of Gaesung industrial complex. Power flow and voltage dynamics are shown and an efficient method for supplying the electric power to Gaesung industrial complex is proposed.

  • PDF

A Study on Correlation between Improvement in Efficiency of PV and Green roof of Public Building (공공건물 옥상녹화와 설치태양광(PV)의 효율향상 상관관계 연구)

  • Lee, Eung Jik
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.111-118
    • /
    • 2013
  • This study aims to investigate advantages of complex installation of green roof and PV system in a public building, to analyze the impact of green roof on the efficiency of PV power generation, and to consider the correlation between green roof and PV power generation. When the temperature and power generation of the modules installed in the green roof and non-green roof of the public building were measured for 3 days, the average temperature of the green roof was 23.6 degrees, and it was 36.1 degrees in the non-green roof which increased by nearly 53%. Overall, the module temperature in the green roof was lower. On the other hand, in relation to the PV generation depending on temperature reduction during the same period, the mono-crystalline module and the poly-crystalline module in the green roof showed an increase in generation at nearly 222.2W and 341.6W, and the efficiency rose by 5.5% and 6.2%, respectively, compared to the modules in the non-green roof. Therefore, it is analyzed that green roof has a positive influence on PV power generation. Finally shows the efficiency of the installed on the Green Roof PV system (complex Installation) higher than on the concrete roof PV system. Thus, the complex PV systems as well as the usual benefits of green roofs will provide greater synergies.

Population Dynamics Pattern of Green Peach Aphid (Homoptera: Aphididae) and Its Predator Complex in a Potato System

  • Ro, Tae-Ho;Garrell E. Long
    • Animal cells and systems
    • /
    • v.2 no.2
    • /
    • pp.217-222
    • /
    • 1998
  • Green peach aphid, Myzus persicae(Sulzer) (Homoptera: Aphididae), interacts with many predatory insects in potato fields during the summer. The concept of the predator complex associated with green peach aphids was applied to explain the interactions between the aphid and its predators. The predator power of the predator complex was determined by two factors: the number of predators and the relative feeding capacity. The dynamics of the green peach aphid population was expressed by the number of individuals while the predator power was used to characterize the predator complex. Cumulative degree-days for green peach aphids were used as a time scale to analyze phonology and dynamics patterns of the aphid and its predator complex. The patterns of population changes in aphids were similar during the period of study(1993-1995) although the highest density of aphids fluctuated significantly from year to year. However, the predator power appeared more stable than the green peach aphid population over the three year period. The results indicated that the predator complex plays an important role to suppress the aphid populations during the latter part of the season and that the applications of control measures for green peach aphids in between the initiation and the peak timing of aphid populations are critical to minimize the damage on potatoes.

  • PDF

Equivalent Admittance and Complex Powers in a Coupling through a Narrow Slit in a Parallel-Plate Waveguide (평행평판도파관의 좁은 슬릿을 통한 결합에 있어서 등가어드미턴스 및 복소전력)

  • Lee, Jong-Ig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.10
    • /
    • pp.2059-2065
    • /
    • 2009
  • In this study, it has been considered that the TEM wave is incident on the transverse slit in the upper plate of a short-ended parallel-plate waveguide (PPW). An equivalent slit admittance and complex power for the case of narrow slit are obtained. The conditions for the slit voltage and the complex power in case of the maximum coupling through the slit with a nearby scatterer exterior the PPW are checked.

Multiple Decoupling Current Control Strategies for LCL Type Grid-Connected Converters Based on Complex Vectors under Low Switching Frequencies

  • Liu, Haiyuan;Shi, Yang;Guo, Yinan;Wang, Yingjie;Wang, Wenchao
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1034-1044
    • /
    • 2019
  • In medium-voltage and high-voltage high-power converters, the switching devices need to operate at a low switching frequency to reduce power loss and increase the power capacity. This increases the delay of the signal sampling and PWM. It also makes the cross-couplings of the d-q current components more severe. In addition, the LCL filter has three cross-coupling loops and is prone to resonance. In order to solve these problems, this paper establishes a complex vector model of an LCL type grid-connected converter. Based on this model, two multiple decoupling current control strategies with passive damping / notch damping are proposed for the LCL type grid-connected converter. The proposed strategies can effectively eliminate the cross-couplings of the converter, achieve independent control of the d-q current components, expand the stable region and suppress the resonance of the LCL filter. Simulation and experimental results verify the correctness of the theoretical analysis and the feasibility of the proposed strategies.

Non-Gaussian wind features over complex terrain under atmospheric turbulent boundary layers: A case study

  • Hongtao, Shen;Weicheng, Hu;Qingshan, Yang;Fucheng, Yang;Kunpeng, Guo;Tong, Zhou;Guowei, Qian;Qinggen, Xu;Ziting, Yuan
    • Wind and Structures
    • /
    • v.35 no.6
    • /
    • pp.419-430
    • /
    • 2022
  • In wind-resistant designs, wind velocity is assumed to be a Gaussian process; however, local complex topography may result in strong non-Gaussian wind features. This study investigates the non-Gaussian wind features over complex terrain under atmospheric turbulent boundary layers by the large eddy simulation (LES) model, and the turbulent inlet of LES is generated by the consistent discretizing random flow generation (CDRFG) method. The performance of LES is validated by two different complex terrains in Changsha and Mianyang, China, and the results are compared with wind tunnel tests and onsite measurements, respectively. Furthermore, the non-Gaussian parameters, such as skewness, kurtosis, probability curves, and gust factors, are analyzed in-depth. The results show that the LES method is in good agreement with both mean and turbulent wind fields from wind tunnel tests and onsite measurements. Wind fields in complex terrain mostly exhibit a left-skewed Gaussian process, and it changes from a softening Gaussian process to a hardening Gaussian process as the height increases. A reduction in the gust factors of about 2.0%-15.0% can be found by taking into account the non-Gaussian features, except for a 4.4% increase near the ground in steep terrain. This study can provide a reference for the assessment of extreme wind loads on structures in complex terrain.

Test of Homogeneity Baseon Complex Survey Data : Discussion Based on Power of Test

  • Heo, Sun-Yeong;Yi, Su-Cheol
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.3
    • /
    • pp.609-620
    • /
    • 2005
  • In the secondary data analysis for categorical data, situations often arise in which the estimated cell variances are available, but not the full matrix of variances. In this case researchers are often inclined to use Pearson-type test statistics for homogeneity. However, for a complex sample observed cell proportions are not distributed as multinomial and Pearson-type test statistic generally is not distributed asymptotically as chi-square distribution. This paper evaluates powers for Wald test and Pearson-type test and the first order corrected test of Pearson-type test for homogeneity. The resulting power curves indicate that as the misspecification effect increases, the amount of inflation of significance level and the loss of power Pearson-type test are getting more severe.

  • PDF

Fundamental Frequency Estimation in Power Systems Using Complex Prony Analysis

  • Nam, Soon-Ryul;Lee, Dong-Gyu;Kang, Sang-Hee;Ahn, Seon-Ju;Choi, Joon-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.154-160
    • /
    • 2011
  • A new algorithm for estimating the fundamental frequency of power system signals is presented. The proposed algorithm consists of two stages: orthogonal decomposition and a complex Prony analysis. First, the input signal is decomposed into two orthogonal components using cosine and sine filters, and a variable window is adapted to enhance the performance of eliminating harmonics. Then a complex Prony analysis that is proposed in this paper is used to estimate the fundamental frequency by approximating the cosine-filtered and sine-filtered signals simultaneously. To evaluate the performance of the algorithm, amplitude modulation and harmonic tests were performed using simulated test signals. The performance of the algorithm was also assessed for dynamic conditions on a single-machine power system. The Electromagnetic Transients Program was used to generate voltage signals for a load increase and single phase-to-ground faults. The performance evaluation showed that the proposed algorithm accurately estimated the fundamental frequency of power system signals in the presence of amplitude modulation and harmonics.