• Title/Summary/Keyword: Complex concentration

Search Result 1,808, Processing Time 0.032 seconds

Effects of Scutellariae Barbatae Herba·Alli bulbus·Oldenlandiae Herba Complex Herbal Acupuncture on Tumor and Immune Response (반지련(半枝蓮)·대산(大蒜)·백화사설초(白花蛇舌草) 복합약침(複合藥鍼)이 종양(腫瘍) 및 면역반응(免疫反應)에 미치는 영향)

  • Song, Ho-sueb;Hwang, Hyeon-seo;Kim, Kee-hyun
    • Journal of Acupuncture Research
    • /
    • v.19 no.4
    • /
    • pp.56-73
    • /
    • 2002
  • Objective : We need to develop a new treatment method which can curve cancer growth and enhance immunity of patients with various kinds of cancer more safely and effectively, for conventional anticancer treatment has lots of problems to be overcomed, in other words, Its efficacy can be recognizible but it doesn't actually give aid to patients due to its side effects. This study was taken up to evaluate the anticancer and immune-enhancing effect of Scutellariae Barbatae Herba, Alli bulbus, Oldenlandiae Herba(SAO) Herbal acupuncture. Methods : SAO Herbal acupuncture solution was made from Scutellariae Barbatae Herba, Alli bulbus, Oldenlandiae Herba by decoction. Experimental group was divided into normal(N), control(TC, cancer group induced by S 180), high and low concentration SAO complex Herbal acupuncture group. In the high and low concentration SAO complex Herbal acupuncture group, SAO Herbal acupuncture solution was injected, on the left and right Chok-samni(足三里, ST36) of ICR-male S 180 rats alternatively, by 200mg/kg and 100mg/kg respectively. In vitro, S 180 was cultured with $200{\mu}g$ and $500{\mu}g$ of SAO Herbal acupuncture solution. In each experimental group, we examined the effect of SAO complex Herbal acupuncture on body weight, antitumor, organ weight, activity of macrophage, activity of B cell, spleen cell division, IL-2 production and population of lymphocytes. Results : 1. In Body weight, no significant change was shown, but In solid cancer weight, the high concentration SAO complex Herbal acupuncture group showed signigicant(P<0.05) decrease and significant(P<0.05) increase in the weight of kidney, compared with control group. 2. In activity of macrophage, low concentration SAO complex Herbal acupuncture group showed significant(P<0.01) increase, but in vitro, there was no significant increase, compared with control group. 3. In activity of B cell, high and low concentration SAO complex Herbal acupuncture group showed no significant decrease, but in vitro, low concentration SAO complex Herbal acupuncture group showed significant(P<0.01) increase, compared with control group. 4. In spleen cell division, high and low concentration SAO complex Herbal acupuncture group had no significant influence on spleen cell division induced by Co A, meanwhile, it was found that macrophge promote spleen cell division in low concentration SAO complex Herbal acupuncture group(P<0.05), compared with control group. 5. In IL-2 production, high concentration SAO complex Herbal acupuncture group showed significant((P<0.05) increase, compared with control group. 6. In population of lymphocytes, high concentration SAO complex Herbal acupuncture group showed significant increase of CD3+(P<0.05), CD4+(P<0.05), CD3+ and CD4+ T cell(P<0.01) and B cell(P<0.05), while low concentration SAO complex Herbal acupuncture group showed significant increase of CD4+(P<0.05), CD8+ T cell(P<0.05) and B cell(P<0.01), compared with control group. Conclusion : SAO Herbal acupuncture inhibited cancer growth and enhanced immunity.

  • PDF

Odorous Compound Concentration Levels in Bon-San Industrial Area and Its Surrounding Regions (김해시 본산공단 주변지역의 환경대기 중 주요 악취물질의 농도 특성에 관한 연구)

  • Jeong, Seong-Wook;Byeon, Ki-Yeong;Park, Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.21 no.1
    • /
    • pp.49-55
    • /
    • 2012
  • In this study, the characteristic of offensive major odorous compound from the Bon-San industrial complex in Gimhae were determined by analytical methods of Gas Chromatography, High Performance Liquid Chromatography and UV/VIS Spectrophotometer. The kind of major odorous compounds examined acetaldehyde, sulfur compounds, ammonia and styrene. The concentration of all odorous compounds at 3 sampling points of industrial complex were lower than those of regulation standard levels of the industrial complex in Korea. The mean concentration of hydrogen sulfide was 0.0235 ppm at sampling point 2, it was higher than other sampling point. Complex odors was lower than regulation standard levels of the industrial complex in Korea.

The Prediction and Evaluation Air Pollutants Concentration around Industrial Complex by using Atmospheric Dispersion Models -Based on ISCST3, FDM, AERMOD- (대기확산모델을 사용한 공단주변지역의 대기오염물질농도 예측 및 평가 -ISCST3, FDM, AERMOD를 중심으로-)

  • 이화운;원경미;배성정
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.485-490
    • /
    • 1999
  • We will calculate concentration of air pollutants using ISCST3, FDM and AERMOD of models recommended in U. S. EPA which are able to predict concentration of short term for point source, complex like industrial complex, power plant and burn-up institution. Before executing model, as analyzing computational result of many cases according to selecting of input data, we will increasing predictable ability of model in limit range of model. Especially, we analyzed three cases-case of considering various emission rate according to time scale and not, case considering effect of atmospheric pollution materials removed by physical process. In our study, after comparing and analyzing results of three model, we choose the atmospheric dispersion model reflected well the characteristic of the area. And we will investigate how large the complex pollutant sources such as industrial complex contribute to atmospheric environment and air quality of the surrounding the area as predicting and estimating chosen model.

  • PDF

열수화법으로 성장시 성장 온도에 따른 ZnO 나노 구조의 표면 형상 변화

  • Bae, Yeong-Suk;Kim, Dong-Chan;Jo, Hyeong-Gyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.238-238
    • /
    • 2009
  • In this work, we investigated the effect of the Zn complex concentration and growth temperature on the growth of ZnO nanorod by hydrothermal method. The ZnO nanorods were performed at condition of the various Zn complex concentration and growth temperature, 0.02 ~ 0.08 M and 60 ~ 80 $^{\circ}C$, respectably. We found from the SEM results that the diameter and length of ZnO nanorods were with increasing the growth temperature and Zn complex concentration. However, the growth condition in the two parameters wasmore than sensitive compared to Zn complex concentration on increasing the growth rate. From photoluminescence(PL) analysis, the strong band-edge emission for ZnO nanorod grown at 80 $^{\circ}C$ with 0.08 M indicated the fine crystallinity. Therefore, the diameter and length of ZnO nanorods have been able to control through the control of front growth parameters. Also, these ZnO nanorods grown low temperature will be available as building block for transparence flexible device applications.

  • PDF

Kinetic Studies on the Ligand Substitution Reactions of Cyanocobalt(II) Complexes in Micellar Solutions (미셀용액에서 Cyanocobalt(II) 착물의 리간드치환 반응에 대한 속도론적 연구)

  • Ahn, Beom-Shu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.370-378
    • /
    • 2009
  • Kinetic studies on the ligand substitution reactions of cyanocomplexes were performed in several micellar solutions. It showed the observed rate constants was found to be independent of the entering ligand concentration at high concentration of cyanopyridine and pyrazinecarboxylate. We could see also that in nonionic and anionic micellar solutions no influence of changes in the surfactant concentration on the observed rate constants was found. Taking into account the hydrophilic nature of the cobalt complex, the cobalt complex molecule was expected to be located in the aqueous phase of the micellar systems, where the reaction would take place. In cationic micellar solutions, a small increase in the observed rate constant was found when the cationic surfactant concentration increased. After reaching a maximum, the rate constant decreased on increasing surfactant concentration and subsequently it reached a plateau, where the observed rate constant was independent of changes in the surfactant concentration.

The PM2.5 Concentration and Components Characteristics in Miryang (밀양지역의 PM2.5 농도 및 성분특성)

  • Suh, Jeong-Min;Kim, Young-Sik;Jeon, Bo-Kyung;Choi, Kum-Chan;Ryu, Jae-Yong;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.16 no.12
    • /
    • pp.1355-1367
    • /
    • 2007
  • This study summarizes the relations among $PM_{2.5}$ concentration, water-soluble ions concentration, metallic element Components characteristics and SPSS in negative ion and metallic element of $PM_{2.5}$ particle in Miryang.(By the urban area, the industrial complex area and the suburban area according to the season) $PM_{2.5}$ concentration of total 72 samples collected from 3 sites turned out to range from 3.47 to 34.7 ${\mu}g/m^3$, and the average concentration was the suburban area-the kin nup(16.00 ${\mu}g/m^3$) > the urban area-the roof of the old Miryang university(10.32 ${\mu}g/m^3$) > the industrial complex-Sapo industrial complex(10.29 ${\mu}g/m^3$). In particular, the suburban area had $PM_{2.5}$ concentration 1.5 times those of urban area, industrial complex. It was thought although the site was suburban and farm-side without pollutants around, it had a higher concentration value influenced by external factors including the brickyard, small-scale incinerator, driving range construction, construction on the Daegu-Busan express and the widening of the four-lane road between Miryang-Anyang nearby. As for water-soluble ions among $PM_{2.5}$ particle collected in Miryang area, $SO4_{2^-}$ accounted for 60% and $NO_{3^-}$, was 30% in spring and summer. And $NO_{3^-}$ accounted for 50% and $SO4_{2^-}$ was 35% in fall and winter. The AI value of metallic Components among $PM_{2.5}$ particle collected in Miryang area had a high value influenced by the apartment complex construction and the extension work of road. The industrial complex area had Zn concentration 3 times, and Fe concentration 2 times those of urban area and suburb area. When it comes to the relation with metallic elements in urban area, the highest coefficient of correlation was between Cr-Fe with 0.85, and Pb-Cd turned out in the reverse correlation. Among metallic elements, the coefficients of correlation between Zn and Cr, Mn, Fe, NI were high in industrial complex area. The highest coefficient of correlation was between Mn-Zn with 0.88, meanwhile Ni and Cu, Cd turned out in the reverse correlation in the suburb area. These coefficients of correlation are attributed to the difference in pollutant sources, rather than difference in pollutant and non-pollutant.

Spectrophotometric Determination of Ti(IV) by means of Methylthymolblue(MTB) Complex (Methylthymolblue(MTB)에 依한 Ti(IV)의 吸光光度分析)

  • Doo Won Park;Chong Nam Lee
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.4
    • /
    • pp.299-303
    • /
    • 1963
  • A method of the colorimetric determination of titanium has been developed, based on the fact (IV) forms a stable blue complex with methylthymolblue(MTB) which is suitable for spectrophotometric determination of titanium in the concentration range of 0.2 to 22 $\mu$g per ml as $TiO_2$. The determination was carried out in the solution of pH range of 2.6 to 3.6, and the absorbancy of complex was at 600m$\mu$ with Coleman spectrophotometer. Titanium forms a 1:1 complex with MTB, which has a molar absorptivity, $1.1{\times}10^4$ at 600m\mu$. The effects of hydrogen ion concentration, reagent concentration, stability of complex, and hydrolysis were studied. Most of cations do not interfere seriously; however, many of anions such as oxalate, citrate, phosphate, chloride interfere in this determination.

  • PDF

Trends of Volitile Organic Compounds in the Ambient Air of Yeosu Industrial Complex (여수산단 대기 중 휘발성유기화합물질 농도 경향)

  • Jeon, Jun-Min;Hur, Dang;Kim, Dong-Sul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.663-677
    • /
    • 2003
  • The concentrations of volatile organic compounds (VOCs) in the ambient air were measured at three sites (Samil-dong, SRO and EFMC) in Yeosu industrial complex during September 2000 to August 2001. Air samples were collected for 24 hours in Silicocan canister (6l) with constant flow samplers every 6 days and analyzed using a cryogenic preconcentration system and a GC/MS. At each site, we identified 35 species known as on both the carcinogenic and mutagenicity by the EPA US (TO-14 manual). No relationship was found between YOCs concentration at three sampling points. Furthermore, the result shows that there appears to be a variety distribution of the concentration. BTX, vinyl chloride and high concentrations of 1,2-dichloroethane were observed at the sampling sites. Especially, high concentration of toxic VOCs, such as vinyl chloride, chloroform, 1,2-dichloroethane and benzene were shown at environmental facilities management cooperation (EMFC) site. They seem to be emitted from the facility of wastewater treatment in Yeosu industrial complex. It was difficult to tell the seasonal variation of total VOCs concentration. Nevertheless, the concentration in winter was typically higher than in summer The concentrations of toxic VOCs contents in Yeosu industrial complex were generally lower than those in Ulsan complex, although those were similar or less than in Seoul and Daegu. Whereas, toluene and styrene emitted from Yeosu industrial complex were higher than those of Edmonton industrial complex in Canada. Especially, toluene was third times higher than those observed from Texas, USA.

Distribution Characteristics of Dust and Heavy Metals in the Atmosphere Around the Steel Industrial Complex

  • Hye-jin Jo;Jong-Ho Kim;Byung-Hyun Shon
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.2
    • /
    • pp.334-344
    • /
    • 2024
  • In Dangjin, Chungcheongnam-do, there are not only power plants and large steel complexes, but also small and medium-sized air pollutant emission facilities. The dust generated by these facilities has a very small particle size and a large surface area due to condensation and physical and chemical reactions, and is discharged containing various harmful substances. Therefore, this study analyzed the distribution of particulate matter and heavy metal concentrations by particle size in the vicinity of the steel complex, residential area, and reference point using an eight-stage Cascade Impactor. Overall, the direct impact sites with a short distance from the steel complex had the highest concentration, followed by the indirect impact sites, and the non-impact sites had the lowest concentration, indicating that they are directly affected by the steel complex. The atmospheric dust concentration distribution showed a bimodal distribution with a minimum value around the 1.1 to 2.1 ㎛ particle diameter. However, during the yellow dust event, the maximum concentration was biased toward coarse particles. The proportion of PM2.5 in the dust tended to be higher in winter, while the ratio between PM2.5 and PM10 was relatively higher in spring. Regardless of the location of the impact point, heavy metals in the dust were dominated by iron and aluminum, followed by zinc, lead, and manganese.

The Influences of Concentration Distribution and Movement of Air Pollutants by Sea Breeze and Mist around Onsan Industrial Complex (온산공업단지 주변의 박무와 해풍발생이 대기오염물질의 이동 및 농도분포에 미치는 영향)

  • Lee, Hyung-Don;Lee, Gou-Hong;Kim, In-Deuk;Kang, Ji-Soon;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.95-104
    • /
    • 2013
  • Onsan Industrial Complex located in a nearby the Ulsan Petrochemical Complex and in the east of the coast. For this reason, air pollution substances emitted by Onsan Industrial Complex especially tend to have an effect on meteorological factors such as sea breeze. In this study, we assessed the frequency of sea breeze and mist using the meteorological data, and analyzed potential temperature and upper wind condition for assessment of atmospheric pollution concentration influenced by meteorological phenomena in a nearby the Onsan industrial complex. From an analysis results, when mist and sea breeze happened, each higher concentration phenomenon of $PM_{10}$ and $SO_2$ appeared each 57.2%, 71.8% and 46.6%, 57.7% respectively. Hence, we confirmed that meteorological phenomena such as mist and sea breeze had an effect on high concentration of air pollution substances in the research area. Analytical result of meteorological data in upper layer using potential temperature and wind condition, we confirmed that advection of air pollution substances emitted in Ulsan Petrochemical Complex by sea breeze have an effect on high concentration in Onsan Industrial Complex and nearby the residential area. In particular;concentration in Onsan Industrial Complex were higher than the average concentration by a factor of more than over 1.5 times when sea breeze by stable condition in atmospheric layer appeared.