Design of Optimal Capacity Coefficients of Flow Control Valves in the Hoist Hydraulic System Using the Complex Method (콤플렉스법에 의한 호이스트 유압회로 유량제어밸브의 최적유량계수 설계)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, two pilot operated check valves, two flow control valves. The capacity coefficients of flow control valves should be adjusted for the hoist to operate at moderate speed and minimize the hydraulic energy loss. However, it is difficult to adjust the four capacity coefficients of flow control valves by trial and error for optimal operation. The steady state model of the hoist hydraulic system is derived and the optimal capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

Design of an Intelligent Streetlight System in USN

  • Oh, Sun Jin
    • International Journal of Advanced Culture Technology
    • /
    • v.2 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, we propose an intelligent streetlight system that has a complex sensor module of temperature, humidity, luminance and motion detection and controlled by the fuzzy logic based central monitoring system in order to get flexible and precise manipulation of the streetlight system in USN environment. The proposed streetlight system provides low power consumption and high efficiency by using sensed data from the complex sensor module, which were collected, processed, and analyzed by the fuzzy logic based central monitoring system. The performance of the proposed streetlight system is to be evaluated by a simulation study in terms of power savings and safety at the fields constructed as a test-bed under several suggested scenarios. Finally, we know that the proposed intelligent streetlight system can maximize the energy savings efficiently with the fuzzy logic based central monitoring system and selective remote dimming control by connecting it to the wireless ubiquitous sensor network (USN) using a Zigbee module.

A Union Model of Human Being and Machine from the Point of Information Processing on the Complex System (복잡계에 대한 정보 처리 관점에서의리 인간과 기계의 결합 모질)

  • 고성범;임기영
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.193-198
    • /
    • 2001
  • In the large scale B2B transaction like buying Express-Train or selling Daewoo Motor, a tremendous amount of variables and factors of chaos functionate in it directly or indirectly. To get effective information processing on the so called complex system like this, it should be possible to unite the global insight power of the human being and the local computing power of the machine. In this paper, we suggested a union model of human being and machine using Hugent concept. Hugent is defined as an agent model which allows us to chemically unite the human's component and the machine's component in terms of information processing. In this paper, we showed that some typical problems contained in the complex system can be treated more easily through the suggested Hugent concept.

  • PDF

Analysis of the $CO_2$ emission amount and characteristics of combined heat and power plants in industrial complex by using the fuel analysis method (연료분석 방법을 적용한 산업단지 열병합발전소 이산화탄소 배출량 및 배출특성분석)

  • Kang, Seok-Hun;Chung, Dae-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1243-1248
    • /
    • 2008
  • $CO_2$ emission amount and characteristics of combined heat and power (CHP) plant in industrial complex of Korea is evaluated by using the fuel analysis method. Fuel analysis methods of several foreign countries and developed one which is developed considering the operation characteristics of the surveyed CHP plants are used. The operation data is surveyed for all of the CHP plants in industrial complex and is composed of fuel consumption amount, generation, sale and efficiency of heat and electricity, condensed steam enthalpy, and etc of the each CHP.

  • PDF

Torsional Vibration Analysis of Shaft System Using Transfer Dynamic Stiffness Coefficient (동강성계수의 전달을 이용한 축계의 비틀림진동 해석)

  • Moon, D.H.;Choi, M.S.;Sim, J.M.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.91-97
    • /
    • 1997
  • Recently, it is increased by degrees to construct complex and large structures. In general, in order to solve the dynamic problem of these structures they have used finite element method(FEM). In this method, however, it is necessary to prove whether its results are correct or not. Therefore it requires much effort, time and many expenses for dynamic analysis of complex and large structures. Authors have developed the transfer dynamic stiffness coefficient method(TDSCM) which is the new vibration analysis method for complex and large structures on personal computer, and confirmed that the results of this method are good for these structures on personal computer. In this paper, TDSCM is applied to the torsional vibration analysis for the shaft system which consist of concentrated disks and shafts of continuous body. First, we formulate algorithms for torsional free and forced vibration analysis, and compare the results of TDSCM and FEM.

  • PDF

New Concept of Apparent Power with Non-Sinusoidal Waveforms (고조파를 함유한 계통에서의 새로운 겉보기전력 개념에 관한 연구)

  • Kim Joo Rak;Shin Chang Ki;Kim Jung Hoon;Lee Byung Ha
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.220-223
    • /
    • 2004
  • This paper presents the new concept in ac power theory with non-sinusoidal waveform. It will be shown that there is discrepancy in the definition of active and complex power in the time and frequency domains when the conventional power theory is considered It will also be shown that the new power theory consistently defines the power quantifies in the time domains.

  • PDF

The power distribution of the open delta connected transformers due to unbalance of the impedances (변압기(變壓器) V결선(結線)에서의 Impedance 불평형(不平衡)으로 의한 전력분배(電力分配))

  • O, Cheol-Su
    • Proceedings of the KIEE Conference
    • /
    • 1985.07a
    • /
    • pp.26-28
    • /
    • 1985
  • The open delta circuit of the power transformer is still often applied, in spite of its reduced utilization of the power. In this paper, a new approach to the calculation of the power and its distribution in each transformer component is presented. For the power evaluation, the method of the complex power analysis is applied.

  • PDF

A study on wind source interpolation based on shape of complex topography (복잡지형 형상에 따른 풍력자원 보정에 관한 연구)

  • Cheang, Eui-Heang;Moon, Chae-Joo;Kim, Eui-Sun;Chang, Young-Hak
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.62-68
    • /
    • 2009
  • There has been a continuous increase in the utilization and utility value of renewable energy such as wind power generation in modem society. Wind condition is the absolute variable to the energy volume in the case of a wind power generation system. For this reason, wind power generators have already been installed in areas where wind velocity is high and the possibility of danger is very low. In other words, instability is likely if the wind velocity in an area is high and where a wind power generation system can be built. On the contrary, low wind velocity is possible in an area with high stability. Therefore, the design and manufacture of a wind power generation system should be carried out in a more complicated topography in order to secure a bigger market. This study examines and suggest how topography affects wind shear by analyzing the measured data in order to predict wind power generation more reliably.

Active Distribution Network Expansion Planning Considering Distributed Generation Integration and Network Reconfiguration

  • Xing, Haijun;Hong, Shaoyun;Sun, Xin
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.540-549
    • /
    • 2018
  • This paper proposes the method of active distribution network expansion planning considering distributed generation integration and distribution network reconfiguration. The distribution network reconfiguration is taken as the expansion planning alternative with zero investment cost of the branches. During the process of the reconfiguration in expansion planning, all the branches are taken as the alternative branches. The objective is to minimize the total costs of the distribution network in the planning period. The expansion alternatives such as active management, new lines, new substations, substation expansion and Distributed Generation (DG) installation are considered. Distribution network reconfiguration is a complex mixed-integer nonlinear programming problem, with integration of DGs and active managements, the active distribution network expansion planning considering distribution network reconfiguration becomes much more complex. This paper converts the dual-level expansion model to Second-Order Cone Programming (SOCP) model, which can be solved with commercial solver GUROBI. The proposed model and method are tested on the modified IEEE 33-bus system and Portugal 54-bus system.

A Study on Power Trading Methods for in a Hydrogen Residential Model (수소주거모델의 전력 거래 참여 방안 고찰)

  • KISEOK JEONG;TAEYOUNG JYUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.91-99
    • /
    • 2023
  • Participation in power trading using surplus power is considered a business model active in the domestic energy trade market, but it is limited only if the legal requirements according to the type, capacity, and use of the facilities to be applied for are satisfied. The hydrogen residential demonstration model presented in this paper includes solar power, energy storage system (ESS), fuel cell, and water electrolysis facilities in electrical facilities for private use with low-voltage power receiving system. The concept of operations strategy for this model focuses on securing the energy self-sufficiency ratio of the entire system, securing economic feasibility through the optimal operation module installed in the energy management system (EMS), and securing the stability of the internal power balancing issue during the stand-alone mode. An electric facility configuration method of a hydrogen residential complex demonstrated to achieve this operational goal has a structure in which individual energy sources are electrically connected to the main bus, and ESS is also directly connected to the main bus instead of a renewable connection type to perform charging/discharging operation for energy balancing management in the complex. If surplus power exists after scheduling, participation in power trading through reverse transmission parallel operation can be considered to solve the energy balancing problem and ensure profitability. Consequentially, this paper reviews the legal regulations on participation in electric power trading using surplus power from hydrogen residential models that can produce and consume power, gas, and thermal energy including hybrid distributed power sources, and suggests action plans.