• Title/Summary/Keyword: Complete occlusion

Search Result 268, Processing Time 0.03 seconds

Complete Denture Occlusion (총의치 교합)

  • Paek, Janghyun
    • The Journal of the Korean dental association
    • /
    • v.55 no.1
    • /
    • pp.82-89
    • /
    • 2017
  • Proponents of bilaterally balanced occlusion believe that this occlusal concept is important for denture retention and stability. However, the critical appraisal of the literature reveals no scientific evidence to support the bilaterally balanced occlusion as the ideal occlusal concept for conventional complete dentures. Current evidence suggests that the occlusal concept has little influence on clinical outcomes or patient satisfaction. Additional randomized controlled clinical trials should be developed taking into account the influence of mucosal resiliency, alveolar ridge anatomy, and parafunctional activities on occlusal concept choice. In this paper, various types of complete denture occlusion (bilaterally balanced occlusion, lingualized occlusion, canine-guided occlusion) will be reviewed and compared.

  • PDF

Vertical Dimension in Complete Denture : A Literature Review & Clinical Procedures (총의치 수직고경 설정에 대한 고찰)

  • Chung, Jun-Yong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.185-195
    • /
    • 2002
  • Purpose This article describes the historic and clinical aspects of the determination of the vertical dimension of occlusion and the synoptic procedure of the determination of the vertical dimension of occlusion in complete denture. The determining procedure of the susceptible vertical dimension of occlusion is one of the most important steps in construction of complete denture and prosthodontic treatment. It is considered essential for the improvement and the recovery of facial esthetics and stomatognathic functions. Results Several methods have been suggested for measurement of the vertical dimension of occlusion in the construction of complete denture and the prosthodontic rehabilitation. These range from pre-extraction records to the use of physiologic rest position, swallowing, phonetics, esthetics and facial proportion, etc. But, there is no universally accepted or completely accurate method. There seems to be no significant advantages of one technique other than those of cost, time and equipment requirements, and seems to be in controversial in determining the vertical dimension. Conclusion The vertical dimension of occlusion should be determined and reinspected carefully by dentist for a successful prosthesis with several methods. The more investigations are necessary for more objective and scientific techniques in determining the vertical dimension of occlusion.

Angiographic Follow-up Result of Cerebral Aneurysms Treated with Coils Covered with Polyglycolic-Polylactic Acid Copolymer

  • Kim, In-Cheol;Chun, Young-Il;Park, Cheol-Wan;Park, Chan-Woo;Lee, Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.286-291
    • /
    • 2006
  • Objective : We evaluate the effect of the copolymer-coated coils on immediate occlusion of the aneurysm, preventing rupture, and decreasing compaction or re-growth. Methods : Thirty-five aneurysms treated between September 2003 and December 2004 using Matrix detachable coil were reviewed. Study population consisted of 12 men and 23 women ranging in age from 34 to 75 years[mean, 55.1 years]. Twenty-two aneurysms were ruptured and 23 aneurysms were located in the anterior circulation. Follow-up angiography was obtained in 16 patients after 6 months from the procedure. Results : Initial complete occlusion was achieved in 17 aneurysms[48.6%], and the others remained as a residual neck in 8 aneurysms[22.8%] and residual sac in 10 aneurysms[28.6%]. Among these incompletely occluded aneurysms, 7 aneurysms were performed follow-up angiography. And 6 of them converted into complete occlusion. In the other hands, among 17 aneurysms achieved complete occlusion initially, 9 aneurysms were performed follow-up angiography. Recurrence due to coil compaction occurred in one aneurysm and the others maintained complete occlusion. There was one mortality case due to thromboembolic complication. Conclusion : In spite of difficulty in achieving complete occlusion with Matrix coil system, there is no rupture or re-rupture during follow-up period. Follow-up angiography shows many conversions of residual sac into complete occlusion. Embolization using Matrix coil system is safe and effective, but the effects of PGLA copolymer need further investigation.

Endovascular Approach in Patients with Acute Complete Occlusion Due to Middle Cerebral Artery Dissection

  • Park, Kang-Hoon;Kwak, Hyo Sung;Park, Jung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.6
    • /
    • pp.717-722
    • /
    • 2020
  • Objective : Dissection of the middle cerebral artery (MCA) is less common than dissection of vessels in the vertebrobasilar system or carotid artery. Acute complete occlusion related to MCA dissection is extremely rare. We report an endovascular approach in patients with acute complete occlusion due to MCA dissection. Methods : We reviewed retrospectively the endovascular procedure and clinical results for acute-stroke patients who underwent recanalization from October 2014 through December 2018. Initial imaging findings and the endovascular procedure were analyzed for patients with acute complete occlusion due to MCA dissection. Results : We undertook first-line aspiration thrombectomy using a Penumbra catheter in 294 patients with acute occlusion of the M1 segment. Of these patients, seven were confirmed to have acute complete occlusion due to MCA dissection. All patients had angiographic findings of an intimal flap at the proximal occlusion site of the MCA. One patient complained of severe headache during microcatheter passage through the occluded lesion and died due to massive bleeding caused by rupture of the false lumen. The remaining patients underwent initial contact aspiration thrombectomy without microcatheter passage. After aspiration thrombectomy, six patients had delayed flow through the MCA. One patient underwent stenting of the MCA because of progressive symptoms. Conclusion : An intimal flap at the proximal portion of an occluded MCA can suggest the possibility of MCA dissection. Contrast aspiration thrombectomy without microcatheter passage can reduce the risk of false lumen rupture in cases of MCA dissection.

Removable prosthodontic occlusion (임상가를 위한 특집 2 - 가철성 보철의 교합)

  • Shin, Soo-Yeon
    • The Journal of the Korean dental association
    • /
    • v.51 no.5
    • /
    • pp.250-254
    • /
    • 2013
  • Modern theories and concepts of occlusion for implants and natural teeth have originated in complete denture construction. Bilateral balanced occlusion as the occlusal scheme of choice has a long history in complete denture construction. The reason that occlusion has always been a consideration in the provision of removable prosthetics is because the adoption of good occlusal practice has a significant and immediate impact on the overall success of the treatment, as it affects denture stability. However, clinicians must remember that there are multiple ways, both successful and unsuccessful, to complete the restoration of a patient's occlusion. The goal is to meet the physiologic, functional, and esthetic needs of the individual patient while applying knowledge, accurate diagnosis, experience, clinical judgement, and attention to detail. This paper describes the features of an ideal occlusion in removable prosthodontics, why these features make it ideal for denture stability, and some technique for achieving these aims.

The artificial teeth arrangement and occlusion for Complete denture (총의치를 위한 인공치배열과 교합)

  • Song, Young-Gyun
    • The Journal of the Korean dental association
    • /
    • v.53 no.6
    • /
    • pp.411-417
    • /
    • 2015
  • In an edentulous situation, the oral rehabilitation with complete denture is substantially different from treatment of natural teeth. The artificial teeth arrangement and occlusion are important factor for the stability of the denture. Bilateral balanced occlusion is that stability of the denture is attained when bilateral contacts exist throughout all excursion and static states of the denture during function and, artificial teeth are arrangement in neutral zone where the forces between the tongue and cheeks or lips are equal. This is how dentist make a favorable prognosis. Therefore, dentists are have to be a little more involved in the selection and arrangement of artificial teeth.

Complete denture treatment using lingualized occlusion scheme at the edentulous patient with severely absorbed flat residual ridges: a case report (심한 치조골 흡수로 인해 편평한 치조제를 보이는 완전 무치악 환자에서 설측 교두 교합을 이용한 의치 수복 증례)

  • Choi, Bum-Shik;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.207-215
    • /
    • 2017
  • Many factors should be considered for successful denture treatment at edentulous patients: support, retention, stability, occlusion, esthetics, etc. The patient who has severely absorbed residual ridges, however, treatments are challenging to satisfy those factors. The dentures that use anatomic artificial teeth show good mastication efficiency and esthetics but, can easily lose stability at absorbed ridges. On the contrary, the dentures that use non-anatomic artificial teeth perform better stability but, lower masticatory efficiency and esthetics at absorbed ridges. The lingualized occlusion, using both anatomic and non-anatomic teeth, introduced for compromise those of the pros and cons. At lingualized occlusion, buccal cusps of the teeth do not contact on centric relation. Therefore, direction of the occlusal force towards lingually, then stability of dentures increases. This case report shows the results of the treatment flat residual ridges using complete dentures with ligualized occlusion to increase dentures stability and satisfactory of the patient.

Coil-Protected Technique for Liquid Embolization in Neurovascular Malformations

  • Keun Young Park;Jin Woo Kim;Byung Moon Kim;Dong Joon Kim;Joonho Chung;Chang Ki Jang;Jun-Hwee Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1285-1292
    • /
    • 2019
  • Objective: To evaluate the safety and efficacy of the coil-protected technique for liquid embolization in neurovascular malformations. Materials and Methods: Twenty-two patients who underwent coil-protected liquid embolization for symptomatic cranial (n = 13) and spinal (n = 9) arteriovenous fistula (AVF) or arteriovenous malformations (AVMs) were identified. A total of 36 target feeder vessels were embolized with N-butyl cyanoacrylate and/or Onyx (Medtronic). This technique was used to promote delivery of a sufficient amount of liquid embolic agent into the target shunt or nidus in cases where tortuous feeding arteries preclude a microcatheter wedging techniqu and/or to prevent reflux of the liquid embolic agent in cases with a short safety margin. The procedure was considered technically successful if the target lesion was sufficiently filled with liquid embolic agent without unintentional reflux. Angiographic and clinical outcomes were retrospectively evaluated. Results: Technical success was achieved for all 36 target feeders. Post-embolization angiographies revealed complete occlusion in 16 patients and near-complete and partial occlusion in three patients each. There were no treatment-related complications. Of the six patients who showed near-complete or partial occlusion, five received additional treatments: two received stereotactic radiosurgery for cerebral AVM, two underwent surgical removal of cerebral AVM, and one underwent additional embolization by direct puncture for a mandibular AVM. Finally, all patients showed complete (n = 19) or near-complete (n = 3) occlusion of the target AVF or AVM on follow-up angiographies. The presenting neurological symptoms improved completely in 15 patients (68.2%) and partially in seven patients (31.8%). Conclusion: The coil-protected technique is a safe and effective method for liquid embolization, especially in patients with various neurovascular shunts or malformations who could not be successfully treated with conventional techniques.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES OF COMPLETE DENTURE OCCLUSION (하악 총의치 교합형태에 따른 하부조직에 미치는 교합력 양태의 3차원적 유합요소법 해석)

  • Lee Young-Soo;Yoo Kwang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.286-318
    • /
    • 1992
  • The objective of preventive dentistry is the maintenance of a healthy dentition for the life of a patient. Unfortunately, if an individual has not received the benefit of a comprehensive program of preventive dentistry and has finally reached the edentulous state, as a consequence, he receives a set of complete denture. Dentures are mechanical devices and subject to the principles of mechanics. In some cases, the general health and nutritional status of the patient are felt to be the causative factors. But, the most important thing in residual ridge resorption is felt to be caused by the unequal distribution of functional forces. This study was to analyze mandibular stresses of complete denture occlusion by three dimensional finite element method. The results were as follows ; 1. As deformation and stress distribution of the complete denture of the mandible were concentrated on the upper lingual side of the mandible, alveolar ridge resorption of the mandible occurred from lingual side to labio-buccal side. 2. Analyzing by three dimensional F. E. M., the mandible is a very effective form for tolerating stress and deformation biomechanically. 3. According to the concentration of stress distibution in the upper buccal side of the lower posteriors, buccal shelf area must be a primary stress bearing area in the lower complete denture. 4. Lower complete denture moved horizontally to the balancing side under lateral occlusal force. 5. Bilateral balanced occlusion should be constructed in the complete denture for denture stability, especially in the protrusive movement. 6. Physical property of the denture base material was as important for stress distribution in the denture base as or even more than that in the mandible. 7. Impression technique is very important because of most of stress was concentrated between them due to close contact of the mandible and the denture base.

  • PDF