• Title/Summary/Keyword: Complete edentulous

Search Result 159, Processing Time 0.022 seconds

3D FINITE ELEMENT ANALYSIS OF OVERDENTURE STABILITY AND STRESS DISTRIBUTION ON MANDIBULAR IMPLANT-RETAINED OVERDENTURE (하악 임플랜트 유지형 피개의치의 안정성과 하악골 응력분포에 대한 3차원 유한요소법적 연구)

  • Hong, Hae-Ryong;Choi, Dae-Gyun;Bak, Jin;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.633-643
    • /
    • 2007
  • Statement of problem: Recently there are on an increasing trend of using implants-especially in edentulous mandible of severly alveolar bone recessed. Purpose: The aim of this study was to analyze the displacement and stress distribution of various mandibular implant-retained overdenture models supported by two implants in interforaminal region under the occlusion scheme load. Material and method: FEA models were made by the 3D scanning of the edentulous mandibular dentiform. The three models were named as Model M1, M2, and M3 accord ing to the position of implants: M1, Lt. incisor area, M2, Canine area, and M3, 1st Premolar area. Inter-implant angulation model was named as M4. Conventional complete denture was named M5 and used as a control group. Ball implant and Gold matrice were used as a retentive anchors. The occlusion type loads were applied horizontally over each tooth. Results: 1. In mandibular implant retained overdenture Canine Protected Occlusion type load resulted in higher levels of stress to the implants and female matrices than other types of loads. 2. The overdenture model M1, with implants in lateral incisor areas resulted in lower stress concentration to the implants and female matrices than other models. 3. In mandibular implant retained overdenture the stresses of the implant and female matrice were lower in mesially inclined implant than these of parallel installed implant. Conclusion: Lateral incisor areas could be the best site for the implants in mandibular implant-retained overdenture. The mandibular implant retained overdenture models mentioned above showed to the lowest stress to the implants and female matrices.

Prosthetic rehabilitation of a fully edentulous patient after maxillectomy: A case report (상악골 절제술을 시행한 완전 무치악 환자에서 폐쇄장치를 이용한 보철 수복 증례)

  • Yoon, Jung-Hoon;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.88-93
    • /
    • 2017
  • Most patients with acquired maxillary surgical defects have difficulties such as functional impairments of mastication, speech, and deglutition as well as various degrees of facial deformity. The purpose of a prosthetic approach is to restore function and appearance with an obturator as normal as possible. This goal can be achieved when there is thoughful preoperative communication between a prosthodontist and a surgeon regarding a rehabilitation. In this case report, prosthetic rehabilitation was planned before the surgery for the patient diagnosed with squamous cell carcinoma in the right maxillary sinus with careful oral examination. Four months after maxillectomy, a definitive obturator was fabricated following the surgical and interim obturation phase. The objective of this case report is to describe the satisfactory results of the patient with improved rehabilitation of mastication, speech, deglutition, and appearance.

Interalveolar ridge crest relation analysis and rehabilitation of edentulous patient using dental CAD software: A case report (치과용 CAD 소프트웨어를 이용한 무치악 환자의 치조제 관계 진단 및 총의치 수복 증례)

  • Hong, Youngsun;Kim, Jong-Eun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.31-36
    • /
    • 2019
  • As the number of elderly population increases, the proportion of edentulous patients is increasing, and the demand for traditional dentures will also increase. Arranging the artificial teeth according to the relationship and shape of the upper and lower alveolar ridge is an important factor increasing the stability of the denture. This case is a 79 year old female patient who wishes to make denture covered by national health insurance for psychological and economical reasons. With the alveolar bone severely atrophic, the dental CAD software was used for accurate diagnosis and the posterior teeth were arranged in a cross bite according to the interalveolar crest line angle by the program. After completion, the denture showed adequate stability and maintenance in periodic examinations and treatment, and the patient also expressed high satisfaction.

Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro study

  • Guo, Ying;Kono, Kentaro;Suzuki, Yasunori;Ohkubo, Chikahiro;Zeng, Jian-Yu;Zhang, Jing
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.55-64
    • /
    • 2021
  • PURPOSE. To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model. MATERIALS AND METHODS. The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm × 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05). RESULTS. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P<.05), while there was no statistical difference between the normal and resorption group (P>.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P<.05). CONCLUSION. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MI-ODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.

Full mouth rehabilitation in edentulous patient with unstable mandibular position using flat table treatment dentures and CAD-CAM technology (치료의치와 CAD-CAM 기술을 이용한 불안정한 하악위를 가진 완전 무치악 환자의 치료 증례)

  • Kim, Yuyeon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Kim, Hyeong-Seob;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.330-338
    • /
    • 2022
  • For edentulous patients with unstable mandibular movements and abnormal facial features due to condylar fractures and morphological abnormalities, it is important to find a stable mandibular position. In this case, the patient's facial improvement, mandibular movement stability, and denture stability were improved by using flat table treatment dentures. In addition, computer-aided design/manufacturing (CAD-CAM) technology was used in denture fabrication to maintain the vertical dimension and lip support of flat table treatment dentures, we report good results in improving the patient's discomfort.

Accuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts

  • Anne Kaline Claudino Ribeiro;Aretha Heitor Verissimo;Rodrigo Falcao Carvalho Porto de Freitas;Rayanna Thayse Florencio Costa;Burak Yilmaz;Sandra Lucia Dantas de Moraes;Adriana da Fonte Porto Carreiro
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.3
    • /
    • pp.139-150
    • /
    • 2024
  • PURPOSE. The purpose of this diagnostic study was to assess the accuracy and time efficiency of a digital method to draw the denture foundation extension outline on preliminary casts compared with the conventional technique. MATERIALS AND METHODS. A total of 28 preliminary edentulous casts with no anatomical landmarks were digitized using a laboratory scanner. The outlining of the entire basal seat of the denture was performed on preliminary casts and digitized. Casts with no extension outline were digitized and outlines were drawn using software (DWOS, Straumann). The accuracy of the extension outlined between both techniques was evaluated in the software (GOM Inspect; GOM GmbH) by file superimposition. Specificity and sensitivity tests were applied to measure accuracy. The paired t-test (95% CI) was used to compare the mean total area and the working time. RESULTS. The accuracy ranged from 0.57 to 0.92. The buccal and labial frenulum showed a lower value in the maxilla (0.57); while the area between the retromolar pad and buccal frenulum (0.64) showed a lower score in the mandible. The maxillary denture foundation and the working time for both arches were significantly longer for the digital method (P < .001). CONCLUSION. The denture foundation extension outline exhibited a sufficiently excellent accuracy for the digital method, except for the maxillary anterior region. However, the digital method required a longer working time.

A Case Report of Maxillary Complete Edentulous Patient with a Class III Jaw Relations (III급 악골 관계를 가진 상악 편악 무치악 환자의 수복)

  • Park, Mi-hee;Hong, Jun-won;Choi, Jee-ha;Lee, Jung-jun;Park, Ju-mi;Song, Kwang-yeob;Ahn, Seung-geun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.431-436
    • /
    • 2009
  • In a case of class III skeletal patients with severe alveolar bone resorption, it must be a complete denture treatment plan provided stable and durable occlusion. Despite a markedly increased tooth mobility and unfavorable crown-to-root ration due to periodontal tissue breakdown, if the inflammatory process is controlled and an adequate oral hygiene performed, fixed splints will be considered. Patient's discomfort will be eliminated by achievement better clinical tooth mobility using fixed splints. So it can be a cost and time effective treatment option. In this case, it used a T-Scan System for confirmation a bilateral balanced occlusion and a occlusal force distribution reflected a patient's functional mandibular movement.

A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE (총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구)

  • Kwon, Kung-Rock;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.389-423
    • /
    • 1998
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography (Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as fellows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely(p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge. the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE (총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구)

  • Kwon, Kung-Rock;Park, Nam-Soo;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.539-573
    • /
    • 1996
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography(Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as follows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely (p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge, the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

A case of digital maxillary complete denture and mandibular implant overdenture fabricated by CAD-CAM technique (완전 무치악 환자에서 CAD-CAM 기법을 이용한 상악 총의치 및 하악 임플란트 피개의치 수복: 증례 보고)

  • Kim, Kun Min;Oh, Kyung Chul;Kim, Sang Hyun;Han, Chol Gwan;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.442-450
    • /
    • 2021
  • The CAD-CAM technique is a rapidly developing field in the dental field and is applied to various fields of prosthetic treatment. Among them, the manufacturing of dentures using the milling technique classified as subtractive manufacturing is one of the commercialized digital full denture manufacturing methods. At the same time, it is possible to more efficiently manufacture a metal framework for implant overdenture by selective laser sintering or melting technique classified as an additive manufacturing method. The purpose of this article is to describe the fabrication of CAD-CAM maxillary complete denture and mandibular implant overdenture as well as its features.