• Title/Summary/Keyword: Compensation movement

Search Result 126, Processing Time 0.025 seconds

한국어 자음약화현상과 인접모음의 고저성

  • Lee Suk-Hyang
    • MALSORI
    • /
    • no.33_34
    • /
    • pp.43-55
    • /
    • 1997
  • This study examined one of the hypotheses on the consonant reduction in Korean inferred from the Articulatory Phonology framework through phonetic experiments: Degree of consonant reduction depends on the height of the neighboring vowels--the lower the height of the neighboring vowel is, the higher the degree of reduction of stop closure period is. The results of this study, in general, turned out to support the hypothesis with some cases requiring other phonetic considerations, e.g., rate of some tongue tip movement in the case of dental lenis stop /t/ or the facts that bilabial lenis stop /p/ share its primary articulators, lips, with the neighboring vowel /u/ and that for bilabial closure, the upper lip lowers more for compensation of little movement of lower lip when its raising gets disturbed for some reasons.

  • PDF

Segmentation of a moving object using binary phase extraction joint transform correlator technology (BPEJTC 기술을 이용한 이동 표적 영역화)

  • 원종권;차진우;이상이;류충상;김은수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.7
    • /
    • pp.88-96
    • /
    • 1997
  • As the need of automatized system has been increased recently together with the development of industrial and military technologies, the adaptive real-time target detection technologies that can be embedded on vehicles, planes, ships, robots and so on, are hgihly demanded. Accordingly, this paper proposes a novel approach to detect and segment the moving targets using the binary phase extraction joint transform correlator (BPEJTC), the advanced image subtraction filter and convex hull processing. The BPEJTC which was used as a target detection unit mainly for target tracking compensating the camera movement. The target region has been detected by processing the successful three frames using the advanced image subtraction filter, and has become more accurate by applying the developed convex hull filter. As shown by some experimental results, it is expected that the proposed approaches for compensation of the camera movement and segmentationof of target region, can be used for th emissile guiddance, aero surveillance, automatic inspectin system as well as the target detection unit of automatic target recognition system that request adaptive real-time processing.

  • PDF

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

A development of accuracy diagnostic system 2-dimensional circular interpolation of machining centers (Machining Center의 2차원 원호보간정밀도 진단 System의 개발)

  • Kim, Jeong-Soon;Namgung, Suk;Tsutusmi, Masacmi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.2
    • /
    • pp.54-65
    • /
    • 1993
  • The paper describes and alternative method based on a new idea to measure the circular movement of machining centers. ISO has employed three testing methods for the acceptance tests of machine tools; the first is a rotating one-dimensional probe method, the second is a two-dimensional probe and a master circular ring, and the third is a kinematic ball bar. The last two methods were proposed and introduced by W. Knapp and J. B. Bryan, respectively. The newly developed method is superior to above two methods; the rotating angle can be detected and the rotating radius is variable. Circular movement errors of machining centers were investigated by the analysis of data measured by R- .THETA. method. Followint observations are obtained 1) The errors which depend on positions, i.e., periodical errors by the pitch of ball screws, errors by compensation of backlash and errors by perpendicularity of X and Y-axis, were analyzed. 2) The errors which depend on NC control system, i.e., errors by the unbalance of position-loop-gaians, errors by velocity-loop-gains and errors by feed speeds, were quantiatively analyzed. 3) The method of extracting error information, which uses moving technique of averaging angle and fourier's analysis data mesured by the R- .THETA. method, was proposed.

  • PDF

Compensation for The Solar Radiation Effect of Radiosonde's Temperature Sensor Using Solar Panel (솔라패널을 이용한 라디오존데 온도센서의 일사보정)

  • Park, Myeong-Seok;Lee, Jin-Wook;Jeung, Se-Jin;Jang, Jea-Won
    • Atmosphere
    • /
    • v.29 no.3
    • /
    • pp.283-294
    • /
    • 2019
  • For the upper air observations, a temperature measurement using radiosonde is a common method, and the compensation of solar radiation effects in the radiosonde temperature sensor is an important factor. In this paper, we present various experiments and compensation methods of the radiosonde temperature sensor to overcome the errors caused by the movement of the radiosonde rotation, etc. The methods and procedures of this study are as follows. First, we used the solar simulator to analyze the temperature variation and solar effect of the temperature sensor in the radiosonde according to the insolation. We also analyzed the temperature variation and solar effect of the temperature sensor according to the incident angle between the solar simulator and radiosonde. Second, we measured and analyzed solar radiation absorbed by solar cells attached to radiosonde. Third, we present combined compensate solution of the first and the second experiment results, to overcome errors caused by insolation effects in the radiosonde temperature sensors. Fourth, we compared that the reference temperature in similar environment with the upper air conditions, to verify the new radiated compensation performance of the radiosonde temperature sensor. Finally, the radiosonde fabricated in this study was raised to the atmosphere, and the laser correction algorithm proposed through experiments was reviewed. As a result of the radiosonde SRS-10 produced in this study, the temperature deviation from Vaisala RS92 was $0.057^{\circ}C$ in nighttime observation, $0.17^{\circ}C$ in daytime observation, It is expected that the GRUAN under WMO will be able to obtain a high test rating of 5.0.

Effect of an Intensive Rehabilitation Program on Physical Activity and Wearing Satisfaction in Traumatic Lower Limb Amputees -A Retrospective Study- (집중재활프로그램이 하지 절단 환자의 신체활동 및 의지 착용감에 미치는 영향 -후향적 연구-)

  • Kim, Jin-Hong;Hong, Ye-Ji;Kim, Yu-Ri;Lee, Gang-Pyo
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.453-463
    • /
    • 2020
  • Purpose: This study aimed to investigate the effect of an intensively rehabilitation program on the gait, balance, functional performance, and wearing satisfaction of patients with traumatic lower extremity amputations caused by industrial accidents. Methods: In this study, the anonymized electronic medical records of individuals who participated in the intensive rehabilitation program (among those who were admitted to the hospital belonging to the Labor Welfare Corporation) due to an industrial accident from August 2018 to September 2019 were collected. As a result, the records of 12 subjects meeting the screening criteria were analyzed. Results: According to the time of application to the intensive rehabilitation program, the 10 Meter Walk Test (10MWT) (p < 0.01), Berg Balance Scale (BBS) (p < 0.01), Timed Up and Go Test (TUG) (p = 0.01), the L Test of Functional Mobility (L-test) (p < 0.01), Prosthetic Limb Users Survey of Mobility (Plus-M) (p < 0.01), and Houghton Score Question (HSQ) (p < 0.01) values significantly improved with time. Conclusion: This study confirmed the positive effect of an intensive rehabilitation program on the gait, balance, functional performance, and wearing satisfaction of patients with traumatic lower extremity amputations caused by industrial accidents. However, this study was limited by the absence of a control group, and, thus, it highlights the need for more extensive research with a large sample.

A comparison study for mask plantar pressure measures to the difference of shoes in 20 female (20대 여성의 신발종류에 따른 족저압 영역별 비교 연구)

  • Kim, Y.J.;Ji, J.G.;Kim, J.T.;Hong, J.H.;Lee, J.S.;Lee, H.S.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.83-98
    • /
    • 2004
  • The purpose of this study was to investigate the test-retest of plantar pressures using the F-Scan system over speeds and plantar regions. 6 healthy female subjects in 20's were recruited for the study. Plantar pressure measurements during locomotor activities can provide information concerning foot function, particularly if the timing and magnitude of the loading profile can be related to the location of specific foot structures such as the metatarsal heads. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right. left shoes - sneakers shoes & dress shoes. It was calibrated by the known weight of the test subject standing on one foot. The Tekscan measurements show the insole pressure distribution as a function of the time. This finding has important implications for the development of plantar pressure test protocols where the function of the forefoot is important. According to the result of analysis it is as follows 1) Center of force trajectory in women's dress shoes display direct movement, compare with center of force trajectory in Sneaker shoes displays a little bit curved slow pronation movement. Sneaker shoes in forefoot part display very quick supination movement, therefore, this shoes effects negative effectiveness for ankle's stability Considering center of force trajectory analyzing the more center of force close straight line, the more movement can be quick movement for locomotion. For foot pressure distribution, center of force trajectory in locomotion is better to curved trajectory with pronation movement. So sneaker shoes style is good shoes considering center of pressure distribution trajectory compare with women's dress shoes. 2) Women's dress shoes increased peak pressure in medial, this is effected by high hill's height. The more increased women's dress shoes's height, the more women's peak pressure will increase, pronation can increase compare with before. Supination movement increase, this focused pressure in lateral, also, supination increased more. If the supination movement increased, foot pressure focused in lateral, therefore, it is appeared force distribution in gait direction. This is bad movement in foot's stability. 3) Women's dress shoes in landing phase displayed a long time, this is when women's dress shoes wear, gait movement is unbalance, so, landing phase displayed a long time. For compensation in gait, swing phase quick movement. 4) Women's dress shoes displayed peak pressure distribution in lateral of rearfoot part, Sneakers shoes displayed peak pressure distribution in medial of forefoot part. Its results has good impact absorption compare with women's dress shoes. In forefoot part, sneakers shoes has good propulsive force compare with women's dress shoes.

Effect of robot arm reach training on upper extremity functional movement in chronic stroke survivors: a preliminary study

  • Cho, Ki Hun;Song, Won-Kyung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.2
    • /
    • pp.93-98
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the effect of robot arm reach training on upper extremity functional movement in chronic stroke survivors. Design: One group pretest-posttest design. Methods: Thirteen chronic stroke survivors participated in this study. Robot arm reach training was performed with a Whole Arm Manipulator (WAM) and a 120-inch projective display to provide visual and auditory feedback. During the robotic arm reach training, WAM provided gravity compensation and assist-as-needed (AAN) force according to the robot control mode. When a participant could not move the arm toward the target for more than 2 seconds, WAM provided AAN force to reach the desired targets. All patients participated in the training for 40 minutes per day, 3 times a week, for 4 weeks. Main outcome measures were the Fugl-Meyer Assessment (FMA), Action Research Arm Test (ARAT) and Box and Block Test (BBT) to assess upper extremity functional movement. Results: After 4 weeks, significant improvement was observed in upper extremity functional movement (FMA: 42.15 to 46.23, BBT: 12.23 to 14.00, p<0.05). In the subscore analysis of the FMA upper extremity motor function domains, significant improvement was observed in upper extremity and coordination/speed units (p<0.05). However, there were no significant differences in the ARAT. Conclusions: This study showed the positive effects of robot arm reach training on upper extremity functional movement in chronic stroke survivors. In particular, we confirmed that robot arm reach training could have a positive influence by leading to improvement of motor recovery of the proximal upper extremity.

Effects of an Intensively Complex Physical Therapy Program on the Pain, Range of Motion, Muscle Strength, Function, Quality of Life, and Depression of Patients with Traumatic Rotator Cuff Injury caused by an Industrial Accident -A Pilot Study- (집중 복합 물리치료 프로그램이 산재 외상성 어깨둘레근 손상 환자의 통증, 관절가동범위, 근력, 기능, 삶의 질과 우울증에 미치는 영향 -예비연구-)

  • Bae, Young-Hyeon;Kim, Sun-Mi;Kim, Min-Ju;Choi, Joon-Kyung;Kim, Kyung-Ae;Ko, Moon-Ju;Kim, Young-Bum
    • PNF and Movement
    • /
    • v.16 no.2
    • /
    • pp.275-286
    • /
    • 2018
  • Purpose: This study aimed to investigate the effect of an intensive rehabilitation program on the pain, range of motion (ROM), muscle strength, function, quality of life (QoL), and depression of patients with traumatic rotator cuff injury caused by an industrial accident. Methods: Seventeen patients with traumatic rotator cuff injury caused by an industrial accident participated in this study. The 12-week treatment included 30 min of manual therapy and 30 min of exercise therapy twice a day, five times a week. The outcomes were measured for evaluating the pain, ROM, muscle strength, function, QoL, and depression before the commencement of the program and after 4, 8, and 12 weeks. Results: According to the time of applying the intensive rehabilitation program, the pain (p<0.01), ROM (p<0.01), muscle strength (p<0.01), function (p<0.01), and depression (p<0.05) significantly improved with time. However, QoL was not statistically significant. Conclusion: This study confirmed the excellent effect of an intensive rehabilitation program on the pain, ROM, muscle strength, function, and depression of patients with traumatic rotator cuff injury caused by an industrial accident. However, this study was limited by the absence of a control group. This pilot study highlights the need for more extensive research with a larger sample.

Study on the Usefulness of respiration compensation PET/CT (호흡보정 PET/CT의 유용성에 관한 연구)

  • Kim, Ki-Jin;Bae, Seok-Hwan;Kim, Ga-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2209-2213
    • /
    • 2011
  • When taking PET/CT, the distortion of the image happens due to the movement of a lesion with respiration. In this study, the experiment was conducted to see if the change in SUV value and distortion of the image could be somewhat corrected by comparing the image which was not compensated with that of the region of lung nodule, compensated with respiration compensation Plumonary Toolkit possessed by this hospital. The records of 17 patients with Lung cancer between May and August 2008. As the result of the experiment, Max SUV value increased by from 4.08% minimum to 43.10% maximum, and the average Max SUV value of lung nodule increased from 6.07 to 7.00(12.16%). In the case of respiration compensation PET/CT, the distortion of the image improved. As there was no significance in the comparison of SCC and Adenocarcinom respectively, though there was a statistically significant level(P<0.05) before and after respiration compensation in SCC-Adenocarcinoma, there was an effect in respiration compensation regardless of Cell types. As the result of the experiment, it was found out that the distortion of standard intake coefficient value and the image was compensated Therefore, the diagnosis of lung cancer and follow up will be able to help.