• Title/Summary/Keyword: Compensation filter

Search Result 648, Processing Time 0.024 seconds

Three-phase Four-wire Series Active Power Filter Control Strategy for The Compensation of Harmonics and Reactive Power Based-on Direct Compensating Voltage Extraction Method (직접 보상전압 추출기법을 이용하여 고조파전류와 무효전력을 보상하는 3상 4선식 직렬 형 능동전력필터의 제어법)

  • 김진선;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.213-221
    • /
    • 2004
  • In recent years, since more and more diode rectifiers with smoothing dc capacitor are used in electronic equipments, household appliances and ac drives, harmonics generated by these loads have become a major issue. In addition, 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. This systems show excessive currents in the neutral. These neutral currents are fundamentally third harmonic, and their presence is tied to wiring failure, elevating of neutral potentials, transformer overheating, etc. In response to the concerns, this paper proposes a series active power filter scheme based on direct compensating voltage extraction method and the advantage of this control algorithm is direct extraction of compensation voltage reference without multiplying gain. Therefore, the calculation of the compensation voltage reference will becom much simpler than other control algorithm. To verify the effectiveness of the proposed algorithm, a prototype active power filter is built and some experiments are carried out.

Sliding Mode Fuzzy Control for Wind Vibration Control of Tall Building (Sliding Mode Fuzzy Control을 사용한 바람에 의한 대형 구조물의 진동제어)

  • 김상범;윤정방
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.79-83
    • /
    • 2000
  • A sliding mode fuzzy control (SMFC) with disturbance estimator is applied to design a controller for the third generation benchmark problem on an wind-excited building. A distinctive feature in vibration control of large civil infrastructure is the existence of large disturbances, such as wind, earthquake, and sea wave forces. Those disturbances govern the behavior of the structure, however, they cannot be precisely measured, especially for the case of wind-induced vibration control. Since the structural accelerations are measured only at a limited number of locations without the measurement of the wind forces, the structure of the conventional control may have the feed-back loop only. General structure of the SMFC is composed of a compensation part and a convergent part. The compensation part prevents the system diverge, and the convergent part makes the system converge to the sliding surface. The compensation part uses not only the structural response measurement but also the disturbance measurement, so the SMFC has a feed-back loop and a feed-forward loop. To realize the virtual feed-forward loop for the wind-induced vibration control, disturbance estimation filter is introduced. the structure of the filter is constructed based on an auto regressive model for the stochastic wind force. This filter estimates the wind force at each time instance based on the measured structural responses and the stochastic information of the wind force. For the verification of the proposed algorithm, a numerical simulation is carried out on the benchmark problem of a wind-excited building. The results indicate that the present control algorithm is very efficient for reducing the wind-induced vibration and that the performance indices improve as the filter for wind force estimation is employed.

  • PDF

A Subband Structured Digital Hearing Aid Design for Compensating Sensorineural Hearing Loss (감음성 난청 보상을 위한 부밴드 구조 디지털 보청기 설계)

  • Park Jo-Dong;Choi Hun;Bae Hveon-Deok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.238-247
    • /
    • 2005
  • In this Paper. we Presents subband design techniques of a compensating filter and adaptive feedback canceller for the digital hearing aid. The sensorineural hearing loss has a hearing threshold that shows a nonlinear characteristic in frequency domain. and its compensation suffers from an echo that produced by an undesired time varying feedback path. Therefore. the digital hearing aid requires the compensator that can adjust gains nonlinearly in frequency bands and eliminate the echo rapidly In the Proposed digital hearing aid. the compensating filter is designed by the adaptive system identification method in subband structure, and the adaptive feedback canceller is designed by the subband affine projection algorithm. The designed compensation filter can control the nonlinear gain in each subband respectively, therefore precise compensation is possible. And the feedback canceller using the subband adaptive filter achieves fast convergence rate. The Performances of the Proposed method are verified by computer simulations as comparing with the behaviors of the previous trials.

Lever Arm Compensation for GPS/INS/Odometer Integrated System

  • Seo Jae-Won;Lee Hyung-Keun;Lee Jang-Gyu;Park Chan-Gook
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.2
    • /
    • pp.247-254
    • /
    • 2006
  • For more accurate navigation, lever arm compensation is considered. The compensation method for GPS and an odometer is introduced and new compensation methods are proposed for an odometer to consider the effect of coordinate transformation errors and the scale factor error. The methods are applied to a GPS/INS/odometer integrated system and the simulation and experimental results show its effectiveness.

New active power filter with low DC voltage for compensation of reactive power and harmonics of high power/voltage load (대용량 고전압 부하의 무효전력 및 고조파 보상을 위한 낮은 DC 전압을 갖는 새로운 능동 파워 필터)

  • 정구호;조규형
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.291-294
    • /
    • 1998
  • This paper presents a new active power filter with low DC voltage for compensating reactive power and harmonics of three-phase high power/voltage harmonic producing load. It has a structure of converter connected in series with power factor correction capacitor. Appropriate size and number of filter capacitor are determined by an equation and applied to simulation of 10kvar 6-pulse SCR rectifier.

  • PDF

Roll Compensation for Homing Seekers with 2-Axis Gimbal (2축 김발 호밍 탐색기에서의 롤운동 보상)

  • Whang, Ick-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.1932-1934
    • /
    • 2001
  • In this paper, a horizontal LOS(line of sight) rate estimator for conventional sea skimming ASM(anti-ship missile) is proposed. A LOS rate dynamics model in 2 axis gimbal system and in homing geometry is derived. And a new LOS rate estimator is proposed by applying a Kalman filter theory to the LOS rate dynamics model. The proposed filter can estimate LOS rates with taking roll motions into account. Simulation results show the proposed filter produces smaller estimation errors than a conventional method.

  • PDF

A Single-Phase Active Power Filter Control with Load Current Estimation Method (부하전류 추정기법에 의한 단상능동전력필터 제어)

  • 곽상신;이무영;최연호;임성운;권우현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.335-342
    • /
    • 2000
  • A new control method for a single-phase active power filter, based on a load current estimation using a DC capacitor voltage of active power filter without sensing nonlinear load current, is proposed in this paper. Because the method proposed can remove the load current sensor in comparison with a conventional method sensing the load current and DC capacitor voltage together, it can make the active power filter easy installation, low cost, small size with no performance detriment. In addition, sample-hold technique and proportional control method is adopted to control the DC capacitor voltage and as no delay element such as LPF or PI control in the conventional method is used, the transient response is fast and good. Operation of a single-phase active power filter which consist of eight mode is explained according to utility voltage, compensation current and switch state, and compensation characteristics of active power filter using proposed method is verified by experiment.

  • PDF

Double-Sharpened Decimation Filter Employing a Pre-droop Compensator for Multistandard Wireless Applications

  • Jeong, Chan-Yong;Min, Young-Jae;Kim, Soo-Won
    • ETRI Journal
    • /
    • v.33 no.2
    • /
    • pp.169-175
    • /
    • 2011
  • This paper presents a double-sharpened decimation filter based on the application of a Kaiser and Hamming sharpening technique for multistandard wireless systems. The proposed double-sharpened decimation filter uses a pre-droop compensator which improves the passband response of a conventional cascaded integrator-comb filter so that it provides an efficient sharpening performance at half-speed with comparison to conventional sharpened filters. In this paper, the passband droop characteristics with compensation provides -1.6 dB for 1.25 MHz, -1.4 dB for 2.5 MHz, -1.3 dB for 5 MHz, and -1.0 dB for 10 MHz bandwidths, respectively. These results demonstrate that the proposed double-sharpened decimation filter is suitable for multistandard wireless applications.