• 제목/요약/키워드: Compensation factor

검색결과 599건 처리시간 0.027초

파워 숄더 래글런 슬리브 재킷의 어깨 높이와 너비 변화에 따른 신체 보정 이미지 (Body compensation image on power shoulder raglan sleeve jacket according to the shoulder height and width)

  • 이시백;서미아;어미경
    • 복식문화연구
    • /
    • 제23권1호
    • /
    • pp.117-125
    • /
    • 2015
  • The purpose of this study is to evaluate the differences of body compensation image on variations in the shoulder height and width of power shoulder raglan sleeve jacket. Nine samples were examined: 3 variations of the shoulder height and 3 variations of the shoulder width. The data was evaluated by 123 fashion design majors. The results were as follows; as a result of analyzing the body compensation image according to changes in the shoulder height and width of power shoulder raglan sleeve jacket, five factors were selected; the shoulder compensation factor, the bust compensation factor, the waist compensation factor, the arm compensation factor and the neck compensation factor. Among these factors, the shoulder compensation factor is the most important factor. Examining the major effect of the body compensation image based on changes in the shoulder height and width of power shoulder raglan sleeve jacket, it had an independent influence on factors about waist, neck, shoulder and arm compensation except a factor about bust compensation, had an influence on interacting effect of factors about shoulder, bust, waist, arm compensation, and it had no influence on interacting effect of a factor about neck compensation. This shows that the shoulder height has larger effect on neck compensation image than the shoulder width in power shoulder raglan sleeve jacket.

슬라이닥을 이용하는 전압 제어 방식의 역률보상시스템 개발 (Development of Voltage Controlled Power Factor Compensation System using Slidac)

  • 정상현;이현우;박영균;박철우
    • 전자공학회논문지
    • /
    • 제54권8호
    • /
    • pp.115-122
    • /
    • 2017
  • 본 논문에서는 슬라이닥을 이용하는 새로운 역률보상시스템을 제안한다. 제안하는 역률보상시스템은 슬라이닥의 출력전압을 커패시터에 인가하여 역률을 보상하는 구조이다. 기존의 커패시터 뱅크 방법을 이용하는 역률보상시스템은 선택 가능한 커패시터 용량이 한정되어 있어 부하 상황에 따라 역률 보상 오차가 발생하지만, 제안 시스템은 커패시터 인가 전압을 슬라이닥을 이용하여 세밀하게 변화시킬 수 있어 변화하는 부하를 추종하여 오차 없이 역률을 100%까지 보상할 수 있다. 기존 시스템과 제안 시스템을 비교하여 제시하고, 제안 시스템의 역률 보상 성능이 우수함을 모의실험과 실험을 통해 확인한다. 제안 시스템을 수용가에 설치할 경우 역률 개선을 통한 전기료 감소, 선로손실 감소, 부하 용량 증대 효과가 기대된다. 특히 발전 사업가측에서는 역률 보상 성능의 향상으로 송전 여유 용량 확보와 발전량 절감이 가능하다.

3상 4선식 전력계통에서 전압제어 방식의 역률보상시스템 (Power Factor Compensation System based on Voltage-controlled Method for 3-phase 4-wire Power System)

  • 박철우;이현우;박영균;정상현
    • 전자공학회논문지
    • /
    • 제54권8호
    • /
    • pp.107-114
    • /
    • 2017
  • 본 논문에서는 3상 4선식 전력계통에서 새로운 전압제어 방식의 역률보상시스템을 제안한다. 제안하는 전압제어 방식의 역률보상시스템은 슬라이닥을 이용하여 가변되는 출력전압을 커패시터에 인가하는 것으로 보상에 필요한 무효전력을 생성한다. 기존의 커패시터 뱅크 방법을 이용하는 역률보상시스템은 선택 가능한 커패시터 용량이 한정되어 있어 부하 상황에 따라 역률보상 오차가 발생하지만, 제안 시스템은 변화하는 부하를 추종하여 오차 없이 역률을 100%까지 보상할 수 있다. 본 논문에서는 3상 4선식 전력계통에서 전압제어 방식의 역률보상시스템과 제어 알고리즘을 개발하였고 모의실험과 실험을 통해 성능을 확인한다. 제안 시스템을 수용가에 설치할 경우 역률 개선을 통한 전기료 감소, 선로손실 감소, 부하 용량 증대 효과가 기대된다. 특히 발전 사업가 측에서는 역률 보상 성능의 향상으로 송전 여유 용량 확보와 발전량 절감이 가능하다.

물류 시스템 적용 유도전동기의 전압강하와 역률 보상 관계 (Voltage Drop and Power Factor Compensation Relation of Induction Motor applied to Logistics System)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제67권3호
    • /
    • pp.155-159
    • /
    • 2018
  • Recently, the expansion or establishment of facilities for the logistics system is increasing. Conveyor facilities play a major role in sorting and transporting logistics. Induction motors are widely used for the operation of these conveyor systems. In the logistics system, a large number of induction motors are used. These motors have a considerable distance from the power source side and have a low power factor. The installation position for the power factor compensation of the induction motor is very important. Since the voltage drop depends on the length of the line, it is an important parameter in capacitor capacity determination for power factor compensation. The capacity of the capacitors installed to compensate the power factor of the inductive load should be designed to the extent that self-excitation does not occur. In this study, we analyze the method of compensating the proper power factor considering the voltage drop and the installation position of the induction motor in the logistics system.

배기팬츠 엉덩이둘레 여유분과 밑위길이 여유분 변화에 따른 시각적 이미지 - 20대 여성을 중심으로 - (Image differences based on changes in hip circumference and crotch length in baggy pants - Focused on women in their 20s -)

  • 최은주;서미아;어미경
    • 복식문화연구
    • /
    • 제20권6호
    • /
    • pp.912-922
    • /
    • 2012
  • With a long crotch length and much ease in the hip area, baggy pants are visually expressed in a variety of designs when compared with regular pants. The purpose of this study is to define the image differences of various baggy pants designs according to hip circumference and crotch length ease. To that end, this study deduced the visual image variable of experimental baggy pants and analyzed visual images according to changes in hip circumference and crotch length. Nine baggy pants with different levels of hip circumference and crotch length ease were produced as experimental pants. The image of each pair of experimental baggy pants was evaluated based on pictures taken of the pants worn by a woman in her 20s with a standard body figure. The image assessment team was composed of 105 clothing majors. The research results are as follows. Four visual image factors of experimental baggy pants were extracted: whole body compensation, lower body compensation, hip compensation, and waist compensation. Among the 4 factors, the whole body compensation factor was shown as the most representative factor. The body compensation image was higher with less hip circumference ease in the experimental baggy pants, and more hip circumference ease created the optical illusion of a larger body figure, presenting a significant difference between waist circumference and hip circumference. The lower body compensation factor, hip compensation factor, and waist compensation factor all showed a significant influence on changes in hip circumference ease. This result shows that changes in hip circumference ease exerted more influence on the body compensation image than did changes in crotch length ease. The results of this study provide basic data for predicting visual images according to differences in the level of ease in baggy pants, helping people select clothing suitable to their preferences and body shapes.

공공분야의 지식관리 시스템 도입요인과 보상요인이 성과에 미치는 영향 (Effects of the KMS Adoption Factor and the Compensation Factor on the Business Performance of Public Organization)

  • 구병관;이선규
    • 한국콘텐츠학회논문지
    • /
    • 제12권10호
    • /
    • pp.418-429
    • /
    • 2012
  • 본 연구는 평가와 보상요인이 지식관리 시스템 도입요인(조직특성, 지식정보특성, 이용자특성)과 성과요인 간에 조절적 역할을 하고 있는지를 실증적으로 분석하였다. 분석 결과 조직 유연성, 신뢰, 지식의 적합성, 기능의 제공정도, 인지된 이익 요인은 KMS 활용도에 조절적인 역할을 하고 있는 것으로 분석되었으며, 사용 용이성, 이용자 전문성 요인은 KMS 활용도에 조절적인 역할을 하지 않는 것으로 나타났다. KMS 만족도에는 조직 유연성, 신뢰, 기능의 제공 정도, 이용자 전문성 요인은 KMS 만족도에 조절적인 역할을 하고 있는 것으로 분석되었으며, 지식의 적합성, 사용 용이성, 인지된 이익 요인은 KMS 만족도에 조절적인 역할을 하지 않는 것으로 나타났다.

고압 유도전동기 역률 보상설비의 특성 해석 (A Characteristic Study on the Power Factor Compensation Application of High Voltage Induction Motor)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.225-230
    • /
    • 2008
  • Reactor starting method has the advantage of simplicity and closed transition in spite of lower starting torque per kVA. This method allows a smooth start with almost no observable disturbance on transition and is suitable for applications such as centrifugal pumps or fans. Reactive power doesn't contribute to work but needs to sustain the electromagnetic field required for the induction motor to operate. Starting power factor of induction motor is specially lower than running power factor. Power factor application is needed to compensate for the lower power factor of induction motor. This power factor compensation systems is occasionally being hit by the effects of the starting reactor connection position at the starting, stopping of high-voltage induction motor. This paper describes voltage and current stress affected by the installation position of power factor compensation application at the reactor starting method.

Research on Grid Side Power Factor of Unity Compensation Method for Matrix Converters

  • Xia, Yihui;Zhang, Xiaofeng;Ye, Zhihao;Qiao, Mingzhong
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1380-1392
    • /
    • 2019
  • Input filters are very important to matrix converters (MCs). They are used to improve grid side current waveform quality and to reduce the input voltage distortion supplied to the grid side. Due to the effects of the input filter and the output power, the grid side power factor (PF) is not at unity when the input power factor angle is zero. In this paper, the displacement angle between the grid side phase current and the phase voltage affected by the input filter parameters and output power is analyzed. Based on this, a new grid side PF unity compensation method implemented in the indirect space vector pulse width modulation (ISVPWM) method is presented, which has a larger compensation angle than the traditional compensation method, showing a higher grid side PF at unity in a wide output power range. Simulation and experimental results verify that the analysis of the displacement angle between the grid side phase current and the phase voltage affected by the input filter and output power is right and that the proposed compensation method has a better grid side PF at unity.

입력 전압 범위가 넓은 벅 AC/DC LED 구동기의 역률 개선을 위한 최적 인덕턴스 선택에 관한 연구 (A Study on Optimal Selection of Inductance for Power Factor Improvement of Buck AC/DC LED Driver With Wide Input Voltage Range)

  • 김만고
    • 전력전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.302-305
    • /
    • 2021
  • Selection of the optimal inductance for power factor improvement of a buck AC/DC light-emitting diode (LED) driver with wide input voltage range is described in this study. The power factor change based on the slope compensation is obtained for various normalized output current (NOC) values using discrete-time domain analysis. The possibility of implementing constant slope compensation is described using power factor curves for various NOC values. NOC = 0.5 is chosen for the value of inductance with consideration for the simple implementation and reduction of inductor size. Experimental results of the inductance corresponding to NOC = 0.5 are presented.

불포화 공극 보정 수화도 모델을 이용한 콘크리트의 자기수축 예측 (Prediction of Autogenous Shrinkage on Concrete by Unsaturated Pore Compensation Hydration Model)

  • 이창수;박종혁
    • 대한토목학회논문집
    • /
    • 제26권5A호
    • /
    • pp.909-915
    • /
    • 2006
  • 콘크리트의 자기수축을 예측하기 위해 기존 수화도와 자기수축의 진행 속도 차이를 불포화공극 생성 속도로 가정하고 시멘트 페이스트의 자기수축 실험을 통하여 물-결합재비에 반비례하는 불포화공극 보정계수를 산정할 수 있었다. 이를 자기수축 기여 성분과 미기여 성분이 고려된 변형 Pickket 모델을 이용하여 콘크리트의 자기수축을 예측하였으며, 실험값 및 기존 Tazawa 모델과 일치하는 경향을 나타내어 불포화공극 보정계수에 의한 자기수축 예측이 타당함을 알 수 있었다. 그러나 강도의 함수로 설정된 기존 CEB-FIP 자기수축 예측 모델의 경우 최종 자기수축률과 자기수축 발현 시간함수에 대하여 다소의 수정이 필요할 것으로 판단된다.